S6065A1003/2001 LIQUID FLOW SWITCHES SPECIFICATION DATA & MOUNTING INSTRUCTIONS FEATURES • • • Cost-effective flow switches for HVAC applications. High-capacity, fully-encapsulated NC/NO micro-switch. A single type suitable for pipes with a diameter of 1 to 8". COMMON SPECIFICATIONS Switching capacity Lifetime Working temperature Electrical connection Protection class Protection standard Housing material Accessories S6065A2001 15 (8) A, 24...250 Vac 50000 cycles at nominal load -40...+85 °C at 90% rel. humidity, non-condensing Screw terminal, wire up to 1.5 mm2 cable ∅ 6...9 mm I according to EN60730 IP65 according to EN60529 ABS and corrosion-protected steel PA2 Paddle set MOUNTING S6065A1003 GENERAL The S6065A1003 and S6065A2001 Liquid Flow Switches are designed for monitoring flow rates in pipes employed in HVAC applications. They are suitable for monitoring flow in water, oil, cooling circuits, and lubrication systems. The S6065A2001 is designed for monitoring aggressive liquids. See Table 1 for the reset and switch points for water. Data for other media must be determined empirically. The S6065A1003 and S6065A2001 Liquid Flow Switches can be mounted in any desired position far from elbows, valves, and filters. NOTE: The arrow on the housing must point downstream. When using multiple paddles, the paddles must be arranged in order of decreasing length downstream, i.e. with the longest paddle facing the oncoming liquid. In the case of vertical pipes, reset the range to balance the paddle weight. To prevent malfunction caused by impurities in the medium, do not mount the device with the housing pointing downwards. MODELS Specification Flow medium Mounting Maximum pipe temperature Pressure Paddle material Lever Sensor body Housing dimensions Weight Approvals S6065A1003 non-aggressive liquid Rp 1" (ISO7/1) 120 °C 11 bar 1.4401 yellow brass yellow brass 113 x 70 x 65 mm 850 g TÜV-approved ® U.S. Registered Trademark Copyright © 2008 Honeywell Inc. • All rights reserved S6065A2001 aggressive liquid Rp 1" (ISO7/1) 120 °C 30 bar 1.4401 1.4404 1.4404 108 x 70 x 72 mm 850 g TÜV-approved EN0B-0314GE51 R01008 S6065A1003/2001 LIQUID FLOW SWITCHES 65 mm 54 mm PG11 R1” 29 mm Fig. 2. S6065A1003 dimensions 135 mm 113 mm 70 mm 132 mm FIELD WIRING COMMON PG11 54 mm RED 72 mm reset / switch point min. flow max. flow 3 3 (m /h) (m /h) 1" 1" 3.6 0.6 / 1.0 2.0 / 2.1 1" 1-1/4" 6.0 0.8 / 1.3 2.8 / 3.0 1" 1-1/2" 9.0 1.1 / 1.7 3.7 / 4.0 1"+2" 2" 15.0 2.2 / 3.1 5.7 / 6.1 1"+2" 2-1/2" 24.0 2.7 / 4.0 6.5 / 7.0 1"+2"+3" 3" 36.0 4.3 / 6.2 10.7 / 11.4 1"+2"+3" 4" 60.0 11.4 / 14.7 27.7 / 29.0 1"+2"+3"+Z* 4" Z 60.0 6.1 / 8.0 17.3 / 18.4 1"+2"+3" 5" 94.0 22.9 / 28.4 53.3 / 55.6 1"+2"+3"+Z* 5" Z 94.0 9.3 / 12.9 25.2 / 26.8 1"+2"+3" 6" 120.0 35.9 / 43.1 81.7 / 85.1 1"+2"+3"+Z* 6" Z 120.0 12.3 / 16.8 30.6 / 32.7 1"+2"+3 8" 240.0 72.6 / 85.1 165.7 / 172.5 1"+2"+3"+Z* 8" Z 240.0 38.6 / 46.5 90.8 / 94.2 *For models with the suffix “Z,” the longest paddle must be used to obtain the values indicated in this table. The Z = 8” paddle must be cut to the proper length to fit into the pipe without touching the inside. 126 mm rec. Qmax (m3/h) pipe Ø 135 mm 113 mm 70 mm 3” paddles (L) DIMENSIONS L Table 1. Reset and switch points for water 1” The flow switch is factory-set to the min. flow rate. To adjust the device to other levels, turn the adjustment screw clockwise. Table 1 lists the reset points and switch points for water. Data for other media must be determined empirically. NOTE: If the flow switch is used as a min. flow controller, another device must be installed downstream for alarm condition activation. 2” SWITCH-POINT ADJUSTMENT NORMALLY OPEN BLUE diameter 4.5 mm 1” NORMALLY CLOSED R1” 3” 2” WHITE L ADJUSTMENT SCREW FOR FLOW RATE Fig. 1. Field wiring Connect the red and the white contacts. The contact redwhite opens when the flow drops below the switch point. When the flow is absent, the contact red-blue closes and can be used as a signal or alarm contact. 29 mm 52 mm 90 mm Fig. 3. S6065A2001 dimensions Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Rolle, Z.A. La Pièce 16, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Strasse 17 71101 Schönaich Germany Phone: (49) 7031 63701 Fax: (49) 7031 637493 http://ecc.emea.honeywell.com Subject to change without notice. Printed in Germany EN0B-0314GE51 R1008
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 2 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:3d225b6b-ddba-41f4-be4f-e210e192f810 Producer : Acrobat Distiller 6.0.1 (Windows) Create Date : 2008:10:14 08:29:19+02:00 Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2008:10:14 08:29:19+02:00 Document ID : uuid:1fdc07d8-aa0c-4511-b73f-c2fc1a183ab9 Format : application/pdf Creator : e671781 Title : Microsoft Word - en0b0314-ge51r1008.doc Author : e671781EXIF Metadata provided by EXIF.tools