Honeywell 8DLLMD500 Lyric Smart Peripheral - Motion Detector User Manual Installation Manual

Honeywell International Inc. Lyric Smart Peripheral - Motion Detector Installation Manual

Installation Manual

This wireless passive infrared motion sensor is intended for use with Honeywell controls that support SiX™ series devices. Mounting Location •The optimal range isobtained at a mountingheight of 7’ 6” (2.3 m).•Allow a clear line-of-sightto all areas to protect.•Do not directly facewindows.•Avoid close proximity tomoving machinery,fluorescent lights, andheating/cooling sources.•For use in applicationswith pets up to 80pounds (36 kilograms).Mounting Options The RF6PIR can be mounted on the wall or in corners: •[A] = Wall mountingholes. •[B] = Corner mountingholes.•The rear tamper plateMUST be mounted to astud, solid wood, or witha robust wall anchor.•UL requirements:  TBDNote: before mounting the RF6PIR permanently, conduct Go/No Go tests (see control’s instructions) to verify adequate signal strength and adjust the device location and orientation as necessary. PRELIMINARY DRAFT IIs – 01/12/15 PLEASE GO TO THE BOTTOM OF THE LAST PAGE FOR FCC/IC AGENCY STATEMENTS
  Enroll the RF6PIR  The RF6PIR can be enrolled and programmed before or after installation.  • Press down on the top latch and separate the front and back covers. • Set the Lyric Smart Controller in Programming Mode. • Remove the RF6PIR battery tab to activate and begin the enrollment process. • The green LED beneath the battery flashes during enrollment (about 8 seconds) and the control beeps (TBD).  • The device sends the device MAC ID address and Services information to the control.  The control registers the device and displays the transmitter data on screen. • Enrollment is confirmed when the RF6PIR LED is ON for 3 seconds [and the control beeps TBD].  • If the sensor is not successfully enrolled during the enrollment period, the LED turns off and the device powers down.  Activate a tamper to restart the enrollment process.  Note: Once enrolled in a system, the sensor cannot be used with another control panel until it is removed from the current control panel. See the Control’s instructions for details on removing devices.  Programming RF6PIR Services Fault device features to “Learn” device “Services” in the control:  - Cover and Wall tamper switches - Selectable Pet Immunity –     Off or up to 80 lbs (36 kg) - Temperature sensor; accuracy ±3°F    Consult the Lyric Smart Controller’s instructions for programming the device in the system.                       Walk Test the RF6PIR After power up and enrollment, activate the Test Mode with the control (see control’s instructions) or use the Flashlight Feature. Test period. Note: the system must be in disarmed mode for the 10 minute Test mode to begin. Walk through the detection area and observe the LED. Test Mode is active for 10 minutes, then automatically exits test mode, disables the LED and enters normal operation mode. To restart the 10 minute Test Mode, use the flashlight feature (see the following section).
  Flashlight Feature The flashlight feature is initially only available for the first 24 hours after the first power up, or until the system is first armed.  This feature is no longer available after the first system arming. Each time the flashlight features is used, and the system is disarmed, the walk test timer restarts for 10 minutes. 1. Use a flashlight with a bright light beam, and stand within 4’ (1.2 m) of the sensor. 2. Swing the light beam past the sensor Lens 3-5 times, holding the beam on the window for 0.5 second each pass.        Detection Patterns  Battery Replacement  • Remove the front cover.  • Replace the battery. Recommended replacement batteries:  Panasonic CR123A Honeywell 466 Duracell DL123 or DL123A • Replace the front cover.  BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212° F (100° C) or incinerate. Dispose of used batteries promptly. Keep away from children.  Specifications Power - Battery: One 3V, Lithium; Panasonic CR123A, Duracell DL 123 or DL 123A, Honywell 466 Battery Life, years (typical): 4 years  Range: 40’ x 56’ / 12 m x 17 m   Wall Mounting Height: 7’ – 9’ (2.1 m – 2.7 m); Optimal 7’6” (2.3 m) Tampers: Cover and Wall; (reported separately to the panel) Operating Temperature: 32° to 122° F / 0° to 50° C Relative Humidity: 5 to 95%; non-condensing Temperature Compensation: Advanced Dual Slope Dimensions: 4.13” H x 2.38” W x 1.61” D / 105 mm H x 60.4 mm W x 41 mm D Weight: x oz / xx g (net weight) Approval Listings FCC / IC   SIA-PIR-01 ETL UL 639    ULC S306-03 RoHS    The product must be tested at least once each year. Zones  A 18  Lower B 46  Intermediate C 36  Long    Note: the flashlight feature only initiates or restarts the Test Mode and does not change any other sensor settings.
  FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. FCC / IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS-210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une reception indésirable. RF Exposure Warning – The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm) from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures. Mise en Garde Exposition aux Frequences Radio: L'antenne (s) utilisée pour cet émetteur doit être installée à une distance de séparation d'au moins 7,8 pouces (20 cm) de toutes les personnes. Support and Warranty REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM. For the latest U.S. warranty information, please go to www.honeywell.com/security/hsc/resources/wa or Please contact your local authorized Honeywell representative for product warranty information.                                                    2014 Honeywell International Inc.  Honeywell and is a registered trademark of Honeywell International Inc.   All other trademarks are the properties of their respective owners.  All rights reserved.             DOC CODE 128B BAR CODE HERE  P/N 800-19202PIR  01/15  Rev BETA      2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747 www.honeywell.com/security

Navigation menu