Honeywell 8DLLYNXPLUS2 Wireless Control / Communicator User Manual 800 13012 A VE3 Supplement

Honeywell International Inc. Wireless Control / Communicator 800 13012 A VE3 Supplement

English Supplement

Download: Honeywell 8DLLYNXPLUS2 Wireless Control / Communicator User Manual 800 13012 A VE3 Supplement
Mirror Download [FCC.gov]Honeywell 8DLLYNXPLUS2 Wireless Control / Communicator User Manual 800 13012 A VE3 Supplement
Document ID2014868
Application IDdYrTH6EMgvdMPPSXXJhdbw==
Document DescriptionEnglish Supplement
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeYes
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize19.44kB (243050 bits)
Date Submitted2013-07-12 00:00:00
Date Available2014-01-08 00:00:00
Creation Date2013-06-19 11:03:26
Producing SoftwareAcrobat Distiller 10.1.4 (Windows)
Document Lastmod2013-06-19 11:03:26
Document TitleMicrosoft Word - 800-13012-A_VE3 Supplement.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: e652388

Important Information
The LYNX Plus Series control is equipped with a redesigned circuit board featuring relocated battery and
communication port connections and redesigned antennas. Please refer to the figure below and to the Summary
of Connections when making wiring connections and routing cables.
WIRE
ROUTING
TUNNELS
TIE-WRAP
POINT
TIE WRAP
TIE WRAP
MOUNT
MOUNTING
HOOKS
TERMINAL
STRIP
NOTE
ENSURE ALL WIRING
IS ROUTED THROUGH
WIRE STRAIN
RELIEF CLIP
TELEPHONE
CONNECTION
WIRE STRAIN
RELIEF CLIP
LOCAL
SOUNDER
DISABLE
SWITCH
BATTERY CABLE
POWERLINE CARRIER
DEVICE CONNECTOR
GSMVLP4G AUDIO
CABLE CONNECTOR
1000-300-006-V5
LYNX Plus Wiring and Connection Overview
EXTERNAL SOUNDERS AND POWERLINE CARRIER DEVICES HAVE NOT BEEN EVALUATED BY UL.
POWER SHUTDOWN NOTE: AT 6.0VDC THE SYSTEM WILL NOT OPERATE.
UL INSTALLATIONS
THE MINIMUM WIRE
SIZE USED FOR
TELEPHONE
INSTALLATIONS
MUST BE #26 GAGE
HARD
WIRED
ZONE
WARNING
TO PREVENT RISK OF
SHOCK, DISCONNECT
TELEPHONE LINE
AT TELECOM JACK
BEFORE SERVICING
THIS UNIT
INCOMING
TELEPHONE
LINE
POS
JACK
INCOMING
PHONE
LINE
K10145WH/K10145X10
OR K10145CN PLUG-IN
TRANSFORMER
9VAC, 25VA
BELL
PREMISES
TELEPHONE
TIP
RING
T SET R
EARTH
GROUND
TO 24HR 110VAC
UNSWITCHED
OUTLET
6-14VDC
120mA max.
2k
OHMS
EOLR
EARTH
GROUND
NOTE
USE ONLY THE
K10145WH/K10145X10
OR K10145CN CLASS 2
TRANSFORMERS
PROVIDED
TIP
GSMVLP4G
COMMUNICATIONS PORT
RING
HAND
PHONE
HWZ
ZONE
SOUND
OUT
AC
AC
STANDARD/HIGH-CAPACITY
BATTERY CONNECTOR
10
11
SUPER HIGH-CAPACITY
BATTERY CONNECTOR
SOUNDERS
AC
POWERLINE CARRIER
DEVICE CONNECTOR
ON
85dB
SIREN
DISABLE
SWITCH
GSMVLP4G AUDIO
CABLE CONNECTOR
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE
WITH THE NATIONAL FIRE PROTECTION ASSOCIATION
STANDARDS ANSI/NFPA 70 NATONAL ELECTRIC CODE AND
NFPA 72 NATIONAL FIRE ALARM CODE, CHAPTER 2
(NATIONAL FIRE PROTECTION ASSOC., BATTERY MARCH
PARK, QUINCY, MA 02169). PRINTED INFORMATION
DESCRIBING PROPER INSTALLATION, EVACUATION
PLANNING AND REPAIR SERVICE IS TO BE PROVIDED WITH
THIS EQUIPMENT.
FCC ID: CFS8DLLYNXPLUS2
(LYNX PLUS SERIES)
COMPLIES WITH FCC RULES,
PART 68 FCC REGISTRATION
No. 5GBUSA-25623-AL-E
RINGER EQUIVALENCE: 0.0043B
THE LYNX PLUS SERIES CONTROLS ARE
COMPATIBLE WITH THE FOLLOWING
INTEGRAL RECHARGEABLE BATTERY PACKS:
P/N LYNXRCHKIT-SC
P/N LYNXRCHKIT-HC
P/N LYNXRCHKIT-SHA
REPLACE EVERY FOUR YEARS
WARNING
THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.
OPERATION IS SUBJECT TO THE FOLLOWING TWO
CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL
INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY
INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.
WEEKLY TESTING IS
REQUIRED TO ENSURE
PROPER OPERATION
OF THIS SYSTEM
LYNX PLUS SERIES ALSO COMPLIES WITH THE FOLLOWING:
CANADIAN STANDARDS ASSOCIATION (CSA) C22.1,
CANADIAN ELECTRICAL CODE, PART 1, SAFETY STANDARD
FOR ELECTRICAL INSTALLATIONS AND CAN/ULC-S540
INSTALLATION OF RESIDENTIAL FIRE WARNING SYSTEMS.
THIS UNIT MAY BE PROGRAMMED TO INCLUDE AN ALARM
VERIFICATION FEATURE THAT WILL RESULT IN A DELAY OF THE
SYSTEM ALARM SIGNAL FROM THE INDICATED FIRE CIRCUITS.
THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS)
SHALL NOT EXCEED 60 SECONDS. NO OTHER INITIATING
DEVICES SHALL BE CONNECTED TO THESE CIRCUITS UNLESS
APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION.
CIRCUIT
(ZONE)
CONTROL UNIT
DELAY-SEC
02 - 25
ZT16
30 seconds
SMOKE DETECTOR
MODEL
DELAY-SEC
5806
10 seconds
LYNX PLUS SERIES SUMMARY OF CONNECTIONS
1000-300-SOC-V5
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2012 Honeywell International Inc.
www.honeywell.com/security
Ê800-13012MŠ
800-13012 9/12 Rev. A

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : e652388
Create Date                     : 2013:06:19 11:03:26-04:00
Modify Date                     : 2013:06:19 11:03:26-04:00
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Title                           : Microsoft Word - 800-13012-A_VE3 Supplement.doc
Creator                         : e652388
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 10.1.4 (Windows)
Document ID                     : uuid:abe0b0ad-b429-4e02-814a-cbe3a1d0b09d
Instance ID                     : uuid:0ae756d6-d3b2-48ef-bb52-afad6e3ce66d
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CFS8DLLYNXPLUS2

Navigation menu