Honeywell F300E1001 User Manual AIR CLEANER Manuals And Guides L0607141

HONEYWELL Air Cleaner Manual L0607141 HONEYWELL Air Cleaner Owner's Manual, HONEYWELL Air Cleaner installation guides

User Manual: Honeywell F300E1001 F300E1001 HONEYWELL AIR CLEANER - Manuals and Guides View the owners manual for your HONEYWELL AIR CLEANER #F300E1001. Home:Heating & Cooling Parts:Honeywell Parts:Honeywell AIR CLEANER Manual

Open the PDF directly: View PDF PDF.
Page Count: 20

DownloadHoneywell F300E1001 User Manual  AIR CLEANER - Manuals And Guides L0607141
Open PDF In BrowserView PDF
Honeywell

OWNER'SGUIDE

F50Fand F300E
Electronic
Air Cleaners

® U.S. Registered Trademark
Copyright © 2004 Honeywell
All Rights Reserved

69-0756-4

F50F AND

F3OOE ELECTRONIC

AIR CLEANERS

CONTENTS

Operating
Getting

Your

the Most from

Maintaining
How

Electronic

Electronic

Before

Air Cleaner

Your Electronic
Prefilter(s),

Air Cleaning

3
Air Cleaner

Cell(s)

and Postfilter(s)

Works

10-Year

Limited

Five-year

Product

Registration

2

UltraClean
Warranty

4
6
11

You Call for Service

Honeywell

69-0756-4

Electronic

14
Coil Guarantee

TM

15
16
17

F50F AND F3OOE ELECTRONIC

AIR

CLEANERS

OPERATINGYOUR ELECTRONICAIR CLEANER
Turn the On-Off

NOTE:

M3584

switch

on the power

box to On.

Set the switch to 1 for On and set the switch to O for
Off.

The air cleaner now
conditioning
system
benefit and cleaner
switch turned on at

operates whenever
your furnace/air
fan operates.
For maximum
air cleaning
air conditioner
coils, leave the air cleaner
all times and the thermostat
fan switch set

to On. Of course, continuous
fan operation
adds to your electric
bill each month. Check your equipment
for the amount of
electricity
needed to run your System fan.
M3586

M6032

When the fan and air cleaner

come

on, the neon

indicator

lights.

You may hear a snapping
(electrical
arcing) sound occasionally
as the air cleaner operates.
This is usually caused by a larger
dust particle that causes a high voltage discharge.The
snapping
sound means that your air cleaner is working as it should.To
hear the snapping
sound, momentarily
press the test button
near the botton of the door. Use the test button any time you
want to prove air cleaner operation.

The switch remains in the On position to keep the air cleaner
running.

M3585A

When the fan and air cleaner stops, the neon light goes off.The
air cleaner is off until the heating or air conditioning
and fan start
again.
If you do not want the air cleaner to run, set the On-Off switch
Off to turn off the air cleaner. Your furnace and air conditioner
continue to operate normally,
but without
air cleaning.
Normally, this switch should
times.

to

the added benefit of
be turn to On at all

M3583

3

69-0756-4

F50F AND

F3OOE ELECTRONIC

AIR CLEANERS

GETTINGTHE MOST FROMYOUR ELECTRONICAIR
CLEANER
Run the
electronic air
cleaner as
much as
possible

For greatest efficiency, the air
do this, set the Fan switch on
sure the air cleaner is turned
even when the furnace or air
NOTE:

cleaner should run all the time. To
your thermostat
to On, and make
on. The fan and air cleaner run
conditioner
is off.

A manual fan switch may be built into the furnace
furnace fan controller.

or

The air cleaner uses less power than a 40 watt light bulb (twocell model--33
watts; single cell model--22
watts). Many
believe that the added cost is more than offset by the added
benefits of full-time air cleaning and full-time air circulation.
And
you may feel that the room temperature
stays more even when
the fan is always on.
Even if your thermostat
does not have a Fan On position, you
can obtain maximum
available air cleaning benefit by making
sure the air cleaner is always turn to On so it operates
whenever
the furnace or air conditioner
is on.

Keep the
cell(s) and
prefilter(s)
clean

Replace postprefilter
regularly

69-0756-4

Although the air cleaner is designed
to be efficient over a wide
range of cell dirt loading conditions,
regular cleaning is your
best assurance
of consistent
performance.
Also, a very dirty
prefilter and cell reduces air flow and, in turn, this reduces the
efficiency of the furnace or air conditioner.
The cell wash
reminder schedule or the optional W8600 Air Cleaner Indicator
should be used to maintain
a regular wash schedule.

A high-efficiency
postfilter
is sometimes
installed in the air
cleaner. This filter increases the efficiency of the air cleaner
should be changed every six months of usage.

4

and

F50F AND F3OOE ELECTRONIC

If you have a
humidifier

All Honeywell

whole

house humidifiers

with the Honeywell
Electronic
filters or system modification.

AIR

CLEANERS

can be used in a system

Air Cleaner

without

any additional

If your system includes an atomizing
humidifier,
you may want
to install a standard furnace filter between the humidifier
and
the air cleaner.This
filter would keep the humidifier
spray
mineral deposits from collecting
on the air cleaner.This
filter
should be checked regularly and changed when it shows signs
of mineral or dirt buildup. If you do not install a filter, you will
probably need to wash the cell(s) and prefilter(s)
more often to
remove the mineral buildup.
If an ultrasonic
room humidifier
is used often, especially
if filled
with tap (undistilled)
water, the cell(s) and prefilter(s)
require
more frequent washing. A white residue accumulates
on the
cell(s) from the minerals in the water. This residue may also
contribute
to "white dust." See About lint or "white dust" section
for more

information.

5

69-0756-4

F50F AND

F3OOE ELECTRONIC

AIR CLEANERS

CLEANING PREFILTER(S), CELL(S) AND
POSTFILTER(S)

CAUTION
Sharp edges.
Can cause personal
injury.
Carefully handle cell(s) or wear protective
avoid cuts from sharp metal edges.

Setting a
regular
cleaning
schedule

gloves

to

To ensure optimum performance
from the air cleaner, the
prefilter(s)
and cell(s) must be cleaned regularly--the
prefilter(s)
should be cleaned every one to six months and the
cell(s) every six to twelve months. Washing
frequency
varies,
depending
on the number of family members,
pets, activities
(such as cooking or woodshop)
and smoking habits. Use the
wash reminder schedule below to help establish and maintain a
regular cleaning schedule.
Mount the wash reminder schedule
in a convenient
location.

ELECTRONICA

IR

CLEANER

WASH

RE

MINDER

J

A

SCHEDULE

tNSTALLZtT_ON
OATE
YEAR

NOTE:

69-0756-4

J

F

M

A

M

J

S

O

N

You may let the heating or air conditioning
system
operate normally while the cell(s) are being washed.
Simply turn off the air cleaner switch.

6

D

F50F AND F3OOE ELECTRONIC

Cleaning the
prefilter(s)

Vacuum

the prefilter

with a brush

attachment,

hose, or soak it in a tub. Do notwash
dishwasher
or car wash.

AIR

CLEANERS

rinse it with a

the prefilter(s)

in the

CAUTION
Burn

Hazard.

Can cause personal
injury.
Allow cell(s) to cool completely
in dishwasher
tend of wash cycle or wear protective
gloves.

Washing the
cell(s) in your
automatic
dishwasher

Hot water
plates.Tip

can accumulate
in the tubes supporting
the cell(s) so these tubes can drain.

and at

the collector

IMPORTANT
•

Checkyour
dishwasher
Owner's manual. Some manufacturers do not recommend
washing electronic
ceil(s)
in their dishwashers.

•

If the dishwasher
has upper and lower arms, position
the cell(s) carefully to allow good water circulation.
Be careful to avoid damaging
the ceil(s) when placing
them in the dishwasher.
Broken ionizer wires or bent

•

collector plates are not covered under the Warranty.
Very dirty cell(s), especially
from tobacco or cooking
smoke, can discolor the plastic parts and the lining of
some dishwashers.
This discoloration
is not harmful.

•

Step t

To minimize it, wash the cell(s) more frequently
or try a
different brand of detergent.
Do NOT allow the dishwasher
to run through
the
dry cycle. This bakes on any contaminants
not
removed during the wash cycle and reduces air
cleaner efficiency.

Put the cell(s) on the lower rack of the dishwasher
with the
airflow arrow pointing up. It may be necessary
to remove the
upper rack. Do not block water flow to the upper arm.
HINT: Lay a few large water glasses between the spikes on the
lower rack, and rest the cell(s) on them so the spikes do not
damage the aluminum
collector blades.

7

69-0756-4

F50F AND

F3OOE ELECTRONIC

Step 2

Using

AIR CLEANERS

your regular

dishwashing

detergent,

allow

the

dishwasher
to run through the complete
wash and rinse cycle.
Do not use the dry cycle. To avoid burns, let the cell(s) cool
completely
before removing,
or wear protective
gloves when
removing the cell(s). Remember
that water may be trapped
inside the cell(s)

Step 3
Step 4

plates.

Tip the cell(s)

so these tubes

Wipe the ionizer wires and contact board on the end of the cell
using your thumb and forefinger
with a small, damp cloth.

inspect the dishwasher.
You may want to rerun the wash and/or
rinse cycle with the dishwasher
empty if you see dirt or residue
from washing the cell(s). If dirt or residue seems excessive,
wash the cell(s) more often or try a different detergent.

\

CAUTION
Hazardous

Chemical.

Can cause personal
injury.
Do not splash detergent
solution

Washing the
cell(s) in a tub

•
•

Wear rubber gloves to avoid
with your skin.
Keep detergent
and solution
of children.

NOTE:

Step t

Step 2

69-0756-4

can drain.

prolonged

in eyes.

detergent

contact

out of reach

Always wash the cell(s) first, then the prefilter(s),
to
keep heavy prefilter lint from getting caught in the
cell(s).

Use a large enough container, such as a laundry
container, to hold one or both cell(s).

tub or trash

NOTE:

Sharp corners
a bathtub.

the surface

Dissolve
detergent
detergent
water, try

about three-fourth
per cell in enough
does not dissolve
another brand, or

8

on the cell(s)

can scratch

of

cup of automatic
dishwasher
hot water to cover the cell(s). If the
readily, or forms a scum on the
use softened water.

F50F AND F3OOE ELECTRONIC

Step 3

AIR

CLEANERS

After the detergent has completely
dissolved,
place the cell(s)
the container and allow to soak for 15 to 20 minutes or until

in

water cools. Agitate them up and down a few times and
remove. Repeat steps 2 and 3, if necessary,
for very dirty cells.

Step 4
Step 5

Step 6
Step 7
Maintainingthe
postfilter

Next, wash the prefilter(s)
wash container.

the same way. Empty

and rinse the

Rinse the cell(s) with a hard spray of very hot water; rinse the
tub clean, then fill the tub with clean hot water and soak for 5 to
15 minutes.
Rinse until the water draining from the cell(s) and
prefilter(s)
no longer feels slippery.

Soak

cell(s)

in a final clear water

rinse for ten minutes.

Wipe the ionizer wires and contact board on the end of the cell
using your thumb and forefinger
with a small, damp cloth.

The optional postfilter cannot be cleaned
replaced every six months of usage.

9

but should

be

69-0756-4

F50F AND

F3OOE ELECTRONIC

AIR CLEANERS

Replacing
electronic air
cleaner
components

Step t
Step 2
Step 3
Step 4
Step 5

inspect

the cell(s)

plates.

Repair,

Slide the prefilter(s)

ionizer

wires

or call your

into the upstream

and bent collector
contractor

prefilter

Firmly

close the access

for service.

guides.

Slide the air cleaner cell(s) in so the air flow arrow
downstream
and the handle(s) face outward.

points

door.

Turn on the air cleaner, if the cell(s) and prefilter(s)
are wet, the
neon light may not come on and you may hear arcing. If the
arcing is annoying,
simply turn the air cleaner off for two to
three hours or until the cell(s) are dry.

\\

\

69-0756-4

for broken

as necessary,

10

F50F AND F3OOE ELECTRONIC

AIR

CLEANERS

HOW ELECTRONICAIR CLEANINGWORKS
A word about
particle size

The particles removed by the electronic
air cleaner tend to be
very small--less
than ten microns. But what is a ten-micron
particle? The eye of an average size sewing needle is about
750 microns across, and the dot in the i in the word micron is
about 400 microns. Generally,
particles smaller than ten
microns can be seen only with a microscope,
except in very
large concentrations,
such as a puff of smoke. Your electronic
air cleaner can remove even smaller particles that can be seen
only with an electron microscope.
Although particles one micron and smaller make up only about
20 percent of the total weight of particles in unfiltered
air, they
account

for over 99 percent

of the numbers

of particles.

Because they are so tiny, these particles tend to remain
suspended
in the air unless they collide with a solid surface.
Then they attach by molecular
adhesion
and stick like glue,
staining walls and furniture and coating your air conditioning
coils. And of course, some of these particles can cause allergic
reactions
or simply make the environment
less pleasant.

_,--749

M6031

How the
electronic air
cleaner works

First, large particles (lint, hair) are caught by the prefilter(s).
Then, as the dirty air passes through the intense high voltage
electric field surrounding
the ionizer wires, all particles, even the
smallest particles down to 0.3 micron are given an electric
charge.The
air then passes into the collector where the
alternate parallel plates are charged positive and negative,
creating a uniform electrostatic
field. Since opposites
attract,
the charged particles stick to the collector plates, having an

11

69-0756-4

F50F AND

F3OOE ELECTRONIC

AIR CLEANERS

opposite electric charge.The
precharged
postfilter
continues
remove small particles from the air. The air leaving the air
cleaner contains very few particles.

to

/POSTFILTER
i._>
------->

DIRTY
AIR

--------_CLEANER
AIR
OUT

a

IONIZER WIRES
(CHARGING
SECTION)

COLLECTOR
(COLLECTOR

PLATES
SECTION)
M6030A

Each time the air circulates through the heating/air
conditioning
system and air cleaner, more particles are removed.
These
particles are generated
by normal household
activities and also
enter the house from outside. That is the reason we

Electronic air
cleaner vs
standard
furnace filter

69-0756-4

recommend

that you use the air cleaner

as much as possible.

The regular

furnace

large,

filter collects

mainly

visible

particles

that reach the filter. Its main purpose is to protect the furnace
and air conditioner
blower. The electronic
air cleaner collects
these large particles
particles.
Its purpose
to protect

the blower,

12

plus many of the smaller, mostly invisible
is to reduce indoor air pollution as well as
air conditioning

coils and heat exchanger.

F50F AND F3OOE ELECTRONIC

Ozone and the
electronic air
cleaner

Electronic

air cleaners

generate

person

CLEANERS

a very small amount

about 0.005 to 0.010 parts per million
highest when the air cleaner is new.
The average

AIR

(ppm).

of ozone,

The amount

can detect the odor of ozone

is

in

concentrations
as low as 0.003 to 0.010 ppm. The U.S. Food
and Drug Administration,
and Health and Welfare Canada
recommend
that indoor ozone concentration
should not exceed
0.050 ppm. As a comparison,
the outdoor ozone
cities is sometimes
higher than 0.100 ppm.
If desired,

the ozone

generated

by the air cleaner

reduced by asking your dealer to:
• Install an activated
carbon filter downstream
•

cleaner, or
Adjust the air cleaner

power

supply

to reduce

level in major

can be
of the air
ozone

production.This
adjustment
reduces ozone production
20-25 percent, but also reduces air cleaning efficiency
seven to ten percent.

About lint or
"white dust"

about
about

White dust is made up of particles that settle out of the air
before they get to the return air duct. You can help prevent this
white dust from settling by running your fan constantly
and:
• Be sure the return registers are not blocked with furniture.
• Be sure the discharge
ducts are clean (best done before
installing the air cleaner).
• Be sure your clothes dryer is vented to the outside and is not
plugged.
• If you have new rugs or drapes or new woolen blankets,
be
aware that the lint from these items will reduce with age.
• In new or remodeled
homes, plaster dust or paint pigment
may contribute
to white dust, but will reduce with time.
• Use of a humidifier
may contribute
to white dust, especially if
filled with undistilled
water.

13

69-0756-4

F50F AND

F3OOE ELECTRONIC

AIR CLEANERS

BEFOREYOU CALL FOR SERVICE
If...

Then...

Electronic
air
cleaner
doesn't

1.

seem

2.

to be working

Arcing (snapping)
seems too frequent

You smell ozone
and find it

blower

If the electronic
cell(s) are wet from washing,
cleaner off for two to three hours.

2.

Check the cell(s) for broken
Repair if necessary.
Wash cell(s) and prefilter(s)

1.
2.
3.
4.

Make sure the furnace
Make sure the access
Make sure the On-Off
On models without the
if the electronic
cell(s)
three hours.

Call your heating

objectionable

69-0756-4

or air conditioner

is

running.
Make sure the access door is firmly closed and latched.
door is not closed properly, an interlock keeps the air
cleaner off.

1.

3.

Neon light on air
cleaner does not
come on

Make sure the furnace

14

ionizer

wires

turn the air

or bent plates.

if dirty.

or air conditioner
fan is running.
door is firmly closed.
switch is in the On position.
Solid State Performance
indicator,
are wet, check again in two to

and air conditioning

dealer.

If

F50F AND F3OOE ELECTRONIC

AIR

CLEANERS

HONEYWELL t 0 YEAR UltraClean COil GUARANTEETM
Guarantee
Send to:
Honeywell
UltraClean

10 Year
Co8 Guarantee

Customer
Care, MN10-1461
1885 Douglas
Drive North
Golden

Valley,

MN 55422

If you properly maintain
your new Honeywell
Electronic Air
Cleaner (EAC), Honeywell
guarantees
that if your indoor coil
requires cleaning within the next 10 years, Honeywell
will pay to
have it professionally
cleaned by a qualified contractor:
-- 75% of the cost (up to $150) when installed with a
Honeywell
Coil Irradiation
Ultraviolet Air Treatment
System
or
--

50% of the cost (up to $100) if a Honeywell
EAC is installed
without a Honeywell
Coil Irradiation
Ultraviolet Air Treatment
System).

•

The UltraClean
Coil Guarantee TM applies to any Honeywell
Electronic
Air Cleaner properly installed with a heat pump,
air conditioner
or high efficiency furnace that is: brand new,
less than one year old; or more than one year old with the
indoor coil professionally
cleaned by a qualified contractor
prior to installation.
Proper maintenance
on the EAC means: keep the power
switch in the On position, periodically
verify power operation,
and wash electronic
cells periodically
as specified in this
Owner's
Guide.

•

•

How to register
your guarantee

Proper maintenance
on the Electronic Air Cleaner means:
periodically
clean the lamp glass and replace UV lamps as
specified in the Owner's
Guide.

The UltraClean
Coil Guarantee TM begins the day you move into
your new home, or the day the Air Cleaner is installed. To
register your guarantee,
complete the Registration
Card in the
back of this Owner's
Guide and enclose:
•

•
•
•

Proof of purchase of a Honeywell
duct-mounted
Electronic
Air Cleaner and Coil Irradiation
Ultraviolet Air Treatment
System.
Proof of purchase
of a new heating/cooing
system within the
last year, or...
Proof of professional
coil cleaning services on existing
equipment.
If your home is new and invoices are not available,
simply
complete the form.

15

69-0756-4

F50F AND

F3OOE ELECTRONIC

AIR CLEANERS

LIMITED FIVE-YEARWARRANTY
Honeywell warrants this product to be free from defects in the workmanship or
materiaIs, under normat use and service, for a period of five (5) years from the
date of purchase by the consumer If, at any time during the warranty period, the
product is defective or maIfunctions, Honeywell shaII repair or replace it (at
HoneywelI's option) within a reasonable period of time.
If the product(s)
a
b

is defective,

please contact:

dealer where you purchased it, or
local Honeywell Authorized Repair Station.

If you do not have a dealer, locate one in your area at www honeywelI.com/
yourhome/
This warranty does not cover removal or reinstaIlation costs This warranty shaII
not apply if it is shown by Honeywell that the defect or malfunction was caused by
damage that occurred while the product was in the possession of a consumer
HoneywelI's sole responsibility shall be repair or replace the product within the
terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR
DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF
ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS
PRODUCT. Some states do not aIIow the exclusion or limitation of incidental or
consequential damages, so this limitation may not apply to you
THE WARRANTIES
SET FORTH
HEREIN
ARE EXCLUSIVE,
AND
HONEYWELL
EXPRESSLY
DiSCLAiMS
ALL OTHER
WARRANTIES,
WHETHER
WRITTEN,
ORAL,
IMPLIED
OR STATUTORY,
INCLUDING
BUT
LIMITED
TO ANY WARRANTIES
OF MERCHANTABILITY,
WORKMANSHIP,
FITNESS
FOR A PARTICULAR
PURPOSE

NOT
OR

This warranty gives you specific legal rights, and you may have other rights which
vary from state to state.
If you have any questions concerning this warranty, please write to Honeywell
Customer Care, 1985 Doagias Dr N, MN 10-1461, Golden Valley, MN 55422. in
Canada, write to Honeywell Limited/Honeywell
Limitee, 36 Dynamic Drive,
Scarborough, Ontario, M1V 4Z9

Warranty Registration
Register your warranty on-line at www honeywell.com/yourhome/under
Registration or send the following form to:
Honeywell Customer Care
MN10-1461
1885 Dougtas Dr N
Golden Valley, MN 55422

69-0756-4

16

Product

F50F AND F3OOE ELECTRONIC

AIR

CLEANERS

Product Registration
(Register
1. Mr
Mrs
First Name:

online

Ms

@ www.honeywell.com/yourhome)

Miss
initial:

Last Name:

Address (Number
and Street):
Zip or Postal Code
City:.
email Address:
2.

Phone

Apt:.
State/Province:

Number:

3.
Date of Purchase
Purchase
Price: $.

(month/day/year)

ex: January/18/98:
(excluding

tax)

4.
Where did you purchase this Honeywell
product:
Heating/cooling
contractor
Utility company
Builder/came
with new home
Other
5.

Model

Number

6. How many other Honeywell products do you own:
None
One
Two
Three
Four or more
7.

Your date

of birth (month/day/year)

8.

Education:
High School
Some College
Technical School
Completed
College
Graduate
School
Other

9.
For your primary
Own
Rent

residence,

10.

Including yourself, what
living in your household?

11.

Your marital

status:

ex. January/18/69:

do you:

is the total number of people
(Ex. 01, 02, 03 ... xx):

Married

Single

12.
Which bestdescribes
yourfamilyincome?
Under$15,000515,O00-$24,999
$25,000535,000550,000575,000
$100,000$149,999Over$150,000

17

69-0756-4

F50F AND

69-0756-4

F3OOE ELECTRONIC

AIR CLEANERS

18

F50F AND F3OOE ELECTRONIC

19

AIR

CLEANERS

69-0756-4

F50F AND

F3OOE ELECTRONIC

AIR CLEANERS

Honeywell t0 Year UltraClean Coil Guarantee

TM

Your Name
Street Add tess
City.
Phone:
email

State
Evening.

Day.

Date you moved

in (for new home).

Please check UItraClean
Coil Guarantee
details for explanation):
C3 UltraClean
Coil Guarantee TM.
C3 Clean Coil Guarantee TM.

Your heating/cooling
Street Address:

contractor

City.
Phone:
Attn

State

Mailroom:

Zip Code

Please

direct

TM

or Clean

Coil Guarantee

TM

(see program

or builder
Zip Code

to Customer

Care,

MN10-1461.

Honeywell
Automation
and Control Solutions
Honeywell
Honeywell Limited-Honeywell
1985 Douglas Drive North
35 Dynamic Drive
Golden Valley, MN 55422
Scarborough, Ontario
M1V 4Z9

69-0756-4

G H Rev. 09-04

Limitee

Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer
paper fibers,

www honeywell comtyourhome



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 20
Page Layout                     : SinglePage
Page Mode                       : UseNone
Producer                        : Goby Monitor Application version 3, 2, 1, 4
Create Date                     : Thu Apr 05 20:39:08 2007
Author                          : 
Title                           : 
Subject                         : 
EXIF Metadata provided by EXIF.tools