Honeywell OWNER'SGUIDE F50Fand F300E Electronic Air Cleaners ® U.S. Registered Trademark Copyright © 2004 Honeywell All Rights Reserved 69-0756-4 F50F AND F3OOE ELECTRONIC AIR CLEANERS CONTENTS Operating Getting Your the Most from Maintaining How Electronic Electronic Before Air Cleaner Your Electronic Prefilter(s), Air Cleaning 3 Air Cleaner Cell(s) and Postfilter(s) Works 10-Year Limited Five-year Product Registration 2 UltraClean Warranty 4 6 11 You Call for Service Honeywell 69-0756-4 Electronic 14 Coil Guarantee TM 15 16 17 F50F AND F3OOE ELECTRONIC AIR CLEANERS OPERATINGYOUR ELECTRONICAIR CLEANER Turn the On-Off NOTE: M3584 switch on the power box to On. Set the switch to 1 for On and set the switch to O for Off. The air cleaner now conditioning system benefit and cleaner switch turned on at operates whenever your furnace/air fan operates. For maximum air cleaning air conditioner coils, leave the air cleaner all times and the thermostat fan switch set to On. Of course, continuous fan operation adds to your electric bill each month. Check your equipment for the amount of electricity needed to run your System fan. M3586 M6032 When the fan and air cleaner come on, the neon indicator lights. You may hear a snapping (electrical arcing) sound occasionally as the air cleaner operates. This is usually caused by a larger dust particle that causes a high voltage discharge.The snapping sound means that your air cleaner is working as it should.To hear the snapping sound, momentarily press the test button near the botton of the door. Use the test button any time you want to prove air cleaner operation. The switch remains in the On position to keep the air cleaner running. M3585A When the fan and air cleaner stops, the neon light goes off.The air cleaner is off until the heating or air conditioning and fan start again. If you do not want the air cleaner to run, set the On-Off switch Off to turn off the air cleaner. Your furnace and air conditioner continue to operate normally, but without air cleaning. Normally, this switch should times. to the added benefit of be turn to On at all M3583 3 69-0756-4 F50F AND F3OOE ELECTRONIC AIR CLEANERS GETTINGTHE MOST FROMYOUR ELECTRONICAIR CLEANER Run the electronic air cleaner as much as possible For greatest efficiency, the air do this, set the Fan switch on sure the air cleaner is turned even when the furnace or air NOTE: cleaner should run all the time. To your thermostat to On, and make on. The fan and air cleaner run conditioner is off. A manual fan switch may be built into the furnace furnace fan controller. or The air cleaner uses less power than a 40 watt light bulb (twocell model--33 watts; single cell model--22 watts). Many believe that the added cost is more than offset by the added benefits of full-time air cleaning and full-time air circulation. And you may feel that the room temperature stays more even when the fan is always on. Even if your thermostat does not have a Fan On position, you can obtain maximum available air cleaning benefit by making sure the air cleaner is always turn to On so it operates whenever the furnace or air conditioner is on. Keep the cell(s) and prefilter(s) clean Replace postprefilter regularly 69-0756-4 Although the air cleaner is designed to be efficient over a wide range of cell dirt loading conditions, regular cleaning is your best assurance of consistent performance. Also, a very dirty prefilter and cell reduces air flow and, in turn, this reduces the efficiency of the furnace or air conditioner. The cell wash reminder schedule or the optional W8600 Air Cleaner Indicator should be used to maintain a regular wash schedule. A high-efficiency postfilter is sometimes installed in the air cleaner. This filter increases the efficiency of the air cleaner should be changed every six months of usage. 4 and F50F AND F3OOE ELECTRONIC If you have a humidifier All Honeywell whole house humidifiers with the Honeywell Electronic filters or system modification. AIR CLEANERS can be used in a system Air Cleaner without any additional If your system includes an atomizing humidifier, you may want to install a standard furnace filter between the humidifier and the air cleaner.This filter would keep the humidifier spray mineral deposits from collecting on the air cleaner.This filter should be checked regularly and changed when it shows signs of mineral or dirt buildup. If you do not install a filter, you will probably need to wash the cell(s) and prefilter(s) more often to remove the mineral buildup. If an ultrasonic room humidifier is used often, especially if filled with tap (undistilled) water, the cell(s) and prefilter(s) require more frequent washing. A white residue accumulates on the cell(s) from the minerals in the water. This residue may also contribute to "white dust." See About lint or "white dust" section for more information. 5 69-0756-4 F50F AND F3OOE ELECTRONIC AIR CLEANERS CLEANING PREFILTER(S), CELL(S) AND POSTFILTER(S) CAUTION Sharp edges. Can cause personal injury. Carefully handle cell(s) or wear protective avoid cuts from sharp metal edges. Setting a regular cleaning schedule gloves to To ensure optimum performance from the air cleaner, the prefilter(s) and cell(s) must be cleaned regularly--the prefilter(s) should be cleaned every one to six months and the cell(s) every six to twelve months. Washing frequency varies, depending on the number of family members, pets, activities (such as cooking or woodshop) and smoking habits. Use the wash reminder schedule below to help establish and maintain a regular cleaning schedule. Mount the wash reminder schedule in a convenient location. ELECTRONICA IR CLEANER WASH RE MINDER J A SCHEDULE tNSTALLZtT_ON OATE YEAR NOTE: 69-0756-4 J F M A M J S O N You may let the heating or air conditioning system operate normally while the cell(s) are being washed. Simply turn off the air cleaner switch. 6 D F50F AND F3OOE ELECTRONIC Cleaning the prefilter(s) Vacuum the prefilter with a brush attachment, hose, or soak it in a tub. Do notwash dishwasher or car wash. AIR CLEANERS rinse it with a the prefilter(s) in the CAUTION Burn Hazard. Can cause personal injury. Allow cell(s) to cool completely in dishwasher tend of wash cycle or wear protective gloves. Washing the cell(s) in your automatic dishwasher Hot water plates.Tip can accumulate in the tubes supporting the cell(s) so these tubes can drain. and at the collector IMPORTANT • Checkyour dishwasher Owner's manual. Some manufacturers do not recommend washing electronic ceil(s) in their dishwashers. • If the dishwasher has upper and lower arms, position the cell(s) carefully to allow good water circulation. Be careful to avoid damaging the ceil(s) when placing them in the dishwasher. Broken ionizer wires or bent • collector plates are not covered under the Warranty. Very dirty cell(s), especially from tobacco or cooking smoke, can discolor the plastic parts and the lining of some dishwashers. This discoloration is not harmful. • Step t To minimize it, wash the cell(s) more frequently or try a different brand of detergent. Do NOT allow the dishwasher to run through the dry cycle. This bakes on any contaminants not removed during the wash cycle and reduces air cleaner efficiency. Put the cell(s) on the lower rack of the dishwasher with the airflow arrow pointing up. It may be necessary to remove the upper rack. Do not block water flow to the upper arm. HINT: Lay a few large water glasses between the spikes on the lower rack, and rest the cell(s) on them so the spikes do not damage the aluminum collector blades. 7 69-0756-4 F50F AND F3OOE ELECTRONIC Step 2 Using AIR CLEANERS your regular dishwashing detergent, allow the dishwasher to run through the complete wash and rinse cycle. Do not use the dry cycle. To avoid burns, let the cell(s) cool completely before removing, or wear protective gloves when removing the cell(s). Remember that water may be trapped inside the cell(s) Step 3 Step 4 plates. Tip the cell(s) so these tubes Wipe the ionizer wires and contact board on the end of the cell using your thumb and forefinger with a small, damp cloth. inspect the dishwasher. You may want to rerun the wash and/or rinse cycle with the dishwasher empty if you see dirt or residue from washing the cell(s). If dirt or residue seems excessive, wash the cell(s) more often or try a different detergent. \ CAUTION Hazardous Chemical. Can cause personal injury. Do not splash detergent solution Washing the cell(s) in a tub • • Wear rubber gloves to avoid with your skin. Keep detergent and solution of children. NOTE: Step t Step 2 69-0756-4 can drain. prolonged in eyes. detergent contact out of reach Always wash the cell(s) first, then the prefilter(s), to keep heavy prefilter lint from getting caught in the cell(s). Use a large enough container, such as a laundry container, to hold one or both cell(s). tub or trash NOTE: Sharp corners a bathtub. the surface Dissolve detergent detergent water, try about three-fourth per cell in enough does not dissolve another brand, or 8 on the cell(s) can scratch of cup of automatic dishwasher hot water to cover the cell(s). If the readily, or forms a scum on the use softened water. F50F AND F3OOE ELECTRONIC Step 3 AIR CLEANERS After the detergent has completely dissolved, place the cell(s) the container and allow to soak for 15 to 20 minutes or until in water cools. Agitate them up and down a few times and remove. Repeat steps 2 and 3, if necessary, for very dirty cells. Step 4 Step 5 Step 6 Step 7 Maintainingthe postfilter Next, wash the prefilter(s) wash container. the same way. Empty and rinse the Rinse the cell(s) with a hard spray of very hot water; rinse the tub clean, then fill the tub with clean hot water and soak for 5 to 15 minutes. Rinse until the water draining from the cell(s) and prefilter(s) no longer feels slippery. Soak cell(s) in a final clear water rinse for ten minutes. Wipe the ionizer wires and contact board on the end of the cell using your thumb and forefinger with a small, damp cloth. The optional postfilter cannot be cleaned replaced every six months of usage. 9 but should be 69-0756-4 F50F AND F3OOE ELECTRONIC AIR CLEANERS Replacing electronic air cleaner components Step t Step 2 Step 3 Step 4 Step 5 inspect the cell(s) plates. Repair, Slide the prefilter(s) ionizer wires or call your into the upstream and bent collector contractor prefilter Firmly close the access for service. guides. Slide the air cleaner cell(s) in so the air flow arrow downstream and the handle(s) face outward. points door. Turn on the air cleaner, if the cell(s) and prefilter(s) are wet, the neon light may not come on and you may hear arcing. If the arcing is annoying, simply turn the air cleaner off for two to three hours or until the cell(s) are dry. \\ \ 69-0756-4 for broken as necessary, 10 F50F AND F3OOE ELECTRONIC AIR CLEANERS HOW ELECTRONICAIR CLEANINGWORKS A word about particle size The particles removed by the electronic air cleaner tend to be very small--less than ten microns. But what is a ten-micron particle? The eye of an average size sewing needle is about 750 microns across, and the dot in the i in the word micron is about 400 microns. Generally, particles smaller than ten microns can be seen only with a microscope, except in very large concentrations, such as a puff of smoke. Your electronic air cleaner can remove even smaller particles that can be seen only with an electron microscope. Although particles one micron and smaller make up only about 20 percent of the total weight of particles in unfiltered air, they account for over 99 percent of the numbers of particles. Because they are so tiny, these particles tend to remain suspended in the air unless they collide with a solid surface. Then they attach by molecular adhesion and stick like glue, staining walls and furniture and coating your air conditioning coils. And of course, some of these particles can cause allergic reactions or simply make the environment less pleasant. _,--749 M6031 How the electronic air cleaner works First, large particles (lint, hair) are caught by the prefilter(s). Then, as the dirty air passes through the intense high voltage electric field surrounding the ionizer wires, all particles, even the smallest particles down to 0.3 micron are given an electric charge.The air then passes into the collector where the alternate parallel plates are charged positive and negative, creating a uniform electrostatic field. Since opposites attract, the charged particles stick to the collector plates, having an 11 69-0756-4 F50F AND F3OOE ELECTRONIC AIR CLEANERS opposite electric charge.The precharged postfilter continues remove small particles from the air. The air leaving the air cleaner contains very few particles. to /POSTFILTER i._> -------> DIRTY AIR --------_CLEANER AIR OUT a IONIZER WIRES (CHARGING SECTION) COLLECTOR (COLLECTOR PLATES SECTION) M6030A Each time the air circulates through the heating/air conditioning system and air cleaner, more particles are removed. These particles are generated by normal household activities and also enter the house from outside. That is the reason we Electronic air cleaner vs standard furnace filter 69-0756-4 recommend that you use the air cleaner as much as possible. The regular furnace large, filter collects mainly visible particles that reach the filter. Its main purpose is to protect the furnace and air conditioner blower. The electronic air cleaner collects these large particles particles. Its purpose to protect the blower, 12 plus many of the smaller, mostly invisible is to reduce indoor air pollution as well as air conditioning coils and heat exchanger. F50F AND F3OOE ELECTRONIC Ozone and the electronic air cleaner Electronic air cleaners generate person CLEANERS a very small amount about 0.005 to 0.010 parts per million highest when the air cleaner is new. The average AIR (ppm). of ozone, The amount can detect the odor of ozone is in concentrations as low as 0.003 to 0.010 ppm. The U.S. Food and Drug Administration, and Health and Welfare Canada recommend that indoor ozone concentration should not exceed 0.050 ppm. As a comparison, the outdoor ozone cities is sometimes higher than 0.100 ppm. If desired, the ozone generated by the air cleaner reduced by asking your dealer to: • Install an activated carbon filter downstream • cleaner, or Adjust the air cleaner power supply to reduce level in major can be of the air ozone production.This adjustment reduces ozone production 20-25 percent, but also reduces air cleaning efficiency seven to ten percent. About lint or "white dust" about about White dust is made up of particles that settle out of the air before they get to the return air duct. You can help prevent this white dust from settling by running your fan constantly and: • Be sure the return registers are not blocked with furniture. • Be sure the discharge ducts are clean (best done before installing the air cleaner). • Be sure your clothes dryer is vented to the outside and is not plugged. • If you have new rugs or drapes or new woolen blankets, be aware that the lint from these items will reduce with age. • In new or remodeled homes, plaster dust or paint pigment may contribute to white dust, but will reduce with time. • Use of a humidifier may contribute to white dust, especially if filled with undistilled water. 13 69-0756-4 F50F AND F3OOE ELECTRONIC AIR CLEANERS BEFOREYOU CALL FOR SERVICE If... Then... Electronic air cleaner doesn't 1. seem 2. to be working Arcing (snapping) seems too frequent You smell ozone and find it blower If the electronic cell(s) are wet from washing, cleaner off for two to three hours. 2. Check the cell(s) for broken Repair if necessary. Wash cell(s) and prefilter(s) 1. 2. 3. 4. Make sure the furnace Make sure the access Make sure the On-Off On models without the if the electronic cell(s) three hours. Call your heating objectionable 69-0756-4 or air conditioner is running. Make sure the access door is firmly closed and latched. door is not closed properly, an interlock keeps the air cleaner off. 1. 3. Neon light on air cleaner does not come on Make sure the furnace 14 ionizer wires turn the air or bent plates. if dirty. or air conditioner fan is running. door is firmly closed. switch is in the On position. Solid State Performance indicator, are wet, check again in two to and air conditioning dealer. If F50F AND F3OOE ELECTRONIC AIR CLEANERS HONEYWELL t 0 YEAR UltraClean COil GUARANTEETM Guarantee Send to: Honeywell UltraClean 10 Year Co8 Guarantee Customer Care, MN10-1461 1885 Douglas Drive North Golden Valley, MN 55422 If you properly maintain your new Honeywell Electronic Air Cleaner (EAC), Honeywell guarantees that if your indoor coil requires cleaning within the next 10 years, Honeywell will pay to have it professionally cleaned by a qualified contractor: -- 75% of the cost (up to $150) when installed with a Honeywell Coil Irradiation Ultraviolet Air Treatment System or -- 50% of the cost (up to $100) if a Honeywell EAC is installed without a Honeywell Coil Irradiation Ultraviolet Air Treatment System). • The UltraClean Coil Guarantee TM applies to any Honeywell Electronic Air Cleaner properly installed with a heat pump, air conditioner or high efficiency furnace that is: brand new, less than one year old; or more than one year old with the indoor coil professionally cleaned by a qualified contractor prior to installation. Proper maintenance on the EAC means: keep the power switch in the On position, periodically verify power operation, and wash electronic cells periodically as specified in this Owner's Guide. • • How to register your guarantee Proper maintenance on the Electronic Air Cleaner means: periodically clean the lamp glass and replace UV lamps as specified in the Owner's Guide. The UltraClean Coil Guarantee TM begins the day you move into your new home, or the day the Air Cleaner is installed. To register your guarantee, complete the Registration Card in the back of this Owner's Guide and enclose: • • • • Proof of purchase of a Honeywell duct-mounted Electronic Air Cleaner and Coil Irradiation Ultraviolet Air Treatment System. Proof of purchase of a new heating/cooing system within the last year, or... Proof of professional coil cleaning services on existing equipment. If your home is new and invoices are not available, simply complete the form. 15 69-0756-4 F50F AND F3OOE ELECTRONIC AIR CLEANERS LIMITED FIVE-YEARWARRANTY Honeywell warrants this product to be free from defects in the workmanship or materiaIs, under normat use and service, for a period of five (5) years from the date of purchase by the consumer If, at any time during the warranty period, the product is defective or maIfunctions, Honeywell shaII repair or replace it (at HoneywelI's option) within a reasonable period of time. If the product(s) a b is defective, please contact: dealer where you purchased it, or local Honeywell Authorized Repair Station. If you do not have a dealer, locate one in your area at www honeywelI.com/ yourhome/ This warranty does not cover removal or reinstaIlation costs This warranty shaII not apply if it is shown by Honeywell that the defect or malfunction was caused by damage that occurred while the product was in the possession of a consumer HoneywelI's sole responsibility shall be repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not aIIow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you THE WARRANTIES SET FORTH HEREIN ARE EXCLUSIVE, AND HONEYWELL EXPRESSLY DiSCLAiMS ALL OTHER WARRANTIES, WHETHER WRITTEN, ORAL, IMPLIED OR STATUTORY, INCLUDING BUT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY, WORKMANSHIP, FITNESS FOR A PARTICULAR PURPOSE NOT OR This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write to Honeywell Customer Care, 1985 Doagias Dr N, MN 10-1461, Golden Valley, MN 55422. in Canada, write to Honeywell Limited/Honeywell Limitee, 36 Dynamic Drive, Scarborough, Ontario, M1V 4Z9 Warranty Registration Register your warranty on-line at www honeywell.com/yourhome/under Registration or send the following form to: Honeywell Customer Care MN10-1461 1885 Dougtas Dr N Golden Valley, MN 55422 69-0756-4 16 Product F50F AND F3OOE ELECTRONIC AIR CLEANERS Product Registration (Register 1. Mr Mrs First Name: online Ms @ www.honeywell.com/yourhome) Miss initial: Last Name: Address (Number and Street): Zip or Postal Code City:. email Address: 2. Phone Apt:. State/Province: Number: 3. Date of Purchase Purchase Price: $. (month/day/year) ex: January/18/98: (excluding tax) 4. Where did you purchase this Honeywell product: Heating/cooling contractor Utility company Builder/came with new home Other 5. Model Number 6. How many other Honeywell products do you own: None One Two Three Four or more 7. Your date of birth (month/day/year) 8. Education: High School Some College Technical School Completed College Graduate School Other 9. For your primary Own Rent residence, 10. Including yourself, what living in your household? 11. Your marital status: ex. January/18/69: do you: is the total number of people (Ex. 01, 02, 03 ... xx): Married Single 12. Which bestdescribes yourfamilyincome? Under$15,000515,O00-$24,999 $25,000535,000550,000575,000 $100,000$149,999Over$150,000 17 69-0756-4 F50F AND 69-0756-4 F3OOE ELECTRONIC AIR CLEANERS 18 F50F AND F3OOE ELECTRONIC 19 AIR CLEANERS 69-0756-4 F50F AND F3OOE ELECTRONIC AIR CLEANERS Honeywell t0 Year UltraClean Coil Guarantee TM Your Name Street Add tess City. Phone: email State Evening. Day. Date you moved in (for new home). Please check UItraClean Coil Guarantee details for explanation): C3 UltraClean Coil Guarantee TM. C3 Clean Coil Guarantee TM. Your heating/cooling Street Address: contractor City. Phone: Attn State Mailroom: Zip Code Please direct TM or Clean Coil Guarantee TM (see program or builder Zip Code to Customer Care, MN10-1461. Honeywell Automation and Control Solutions Honeywell Honeywell Limited-Honeywell 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 69-0756-4 G H Rev. 09-04 Limitee Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers, www honeywell comtyourhome
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 20 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Thu Apr 05 20:39:08 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools