Honeywell HAQ Indoor Air Quality Monitor User Manual

Honeywell International Inc Indoor Air Quality Monitor

Contents

User Manual

Honeywell Indoor Air Quality (IAQ)
User Manual Sensing and Productivity
Solutions Honeywell
www.honeywell.com.cn
About the Product
Basic Specications Range and Precision
App Download
Product Measurement: 80x80x22(mm)
Weight: HAQSPF 150g / HAQSPA 156g
USB Port: Micro USB
Materials: Aluminum alloy casing
Screen: OLED Touch screen
Input Voltage: 5V
Input Current: 1A
Battery: 18650 lithium-ion battery
Battery Capacity: 2600mAh
Description Detection Range Precision/Resolution
PM2.5 100—999ug/m3±15%
<100ug/m3±15ug/m3
HCHO
(Formaldehyde) 0 — 2ppm 0.01ppm(resolution)
Temperature -10— 40 ±1
Humidity 0% — 100% ±5%
IQ% 0 — 100% 1%(resolution)
Wireless connection: Wi-Fi IEEE 802.11 b/g/n 2.4GHz
Equipment requirements: Supports mobile phones with Android 4.42 or iOS
8.0 or better
Note: Supports only iPhone5 and later versions
Scan the barcode or search Honeywell IAQ in Apple Store
and Android Market
iOS Android
Network Connection
1. Press and hold Start button on the top of the equipment
for 5 seconds
2. Press and hold Wi-Fi button and wait for a “tick” sound
from the equipment. The Wi-Fi icon will ash, indicating
that the equipment can now be connected to the
network
3. Download the App, add new device, connect by
following App’s instruction interface
IQ%: The data reect the impact of the air environment on
an individual’s cognitive ability, as the latter differs according
to the air environment. Higher IQ% means better effect of the
air environment on cognitive ability.
Cognitive ability mainly includes the following: basic mobility,
utilization of mobility, level of focus on assigned task,
information collection, information processing, breadth of
thought, strategy, task orientation and response to crisis.
Note: Cognitive ability differs from individual to individual. IQ% only reects the
impact of air environment elements on cognitive ability.
An excellent air environment is capable of effectively raising cognitive ability,
thus improving efciency of various activities.
About App Functions
Self-dened alarm value: Default alarm value is factory
setting. For threshold please see explanation above for
App icon. The user can dene alarm value according to
its own needs. The equipment’s indicator light and App
on the user’s mobile phone will display in accordance
with the user’s denitions.
Alarm clock: 3 alarm clocks can be set for each device
while it is connected to the network. If the alarm clock
rings simply touch the screen or press the Home button
to switch it off. The alarm clock will stop after 10 minutes
if there is no operation.
PM2.5 HCHO TVOC IQ%
0 — 79ug/m3< 0.08ppm < 0.38ppm < 1000ppm >60%
80 — 199ug/m3 — —
> 200ug/m3>0.08ppm >0.38ppm >1000ppm <60%
App Icon and Instructions on Colors
Note: Air quality of PM2.5 and IQ% are showed through the change of font
color accordingly .
HAQSPF
HAQSPA
Temp Humidity
Formaldehyde IQ% App
PM
2.5
TV
OC
Time
Alarm
Honeywell Indoor Air Quality (IAQ) is a multi-functional Indoor
Air Quality (IAQ) capable of generating at real time, numerous
air quality data. Used in conjunction with mobile phone App,
it allows users to monitor at all times and anywhere, indoor
air quality and take appropriate measures.
Product Code
TVOC 0.12— 0.99ppm
400 — 2000ppm
0.01ppm(resolution)
1ppm(resolution)
CO2
CO2
CO2
- -
Mode and Setting Interface Instructions
Enter the main interface after activating the device.
Press the icon light to switch to main screen; it will show
real-time air value.
Flashing icon indicates excess values.
The device will automatically switch to standby interface
if no operation is being carried out after 3 minutes;
standby mode will also be indicated at App side.Lightly
touch the screen to switch back to the main interface.
Sleep mode: The screen and indicator light will extinguish
during set time durations and the frequency of data collection
will reduce to once per hour. Switch the mode using the App
if the device is connected to network.
Energy-saving mode: The frequency of data collection for
the device will reduce to once per hour. Switch the mode
using the App if the device is connected to network.
Standby interfaceMain interface
92
92
Attention
Warranty
FCC Statements
IC Statements
RF Exposure
Device indicator light and color: The device’s indicator light
shows the current air quality indicator for the detection item
Detection
Item Green Orange Red
PM2.5 0 — 79ug/m380 — 199ug/m3≥200ug/m3
Formaldehyde < 0.08ppm > 0.08ppm
TVOC < 0.38ppm > 0.38ppm
< 1000ppm > 1000ppm
Temperature -10— 40
Humidity 0% — 100%
IQ% > 60% < 60%
Matters to note when detection formaldehyde: The Indoor
Air Quality (IAQ)’s formaldehyde sensor is electrochemical
sensor. As such it is normal for the sensor to give higher
reading when the device is activated. Place the device in a
well-ventilated position after it is activated and carry on further
detection after the formaldehyde reading is less than 0.03;
detection data over 12 hours in an enclosed room will be
more accurate. As the device’s electrochemical sensor can
also be affected by toluene, benzene, alcohol, acetic acid,
hydrogen sulde and carbon monoxide which can found in
alcohol, perfume, cosmetics and pesticides, please make
sure that such items are not near to the device when carrying
out formaldehyde detection.
The device needs to be connected to network in order for
Under circumstances where the product is in normal use and
maintenance, Honeywell provides users with the warranty that
this product will have no defects in processing or materials
within one (1) year following the date of purchase. Where
Honeywell veries such product experiences any defect or
malfunction in any form within the specied warranty period,
Honeywell will repair or replace any defect product upon
verication. In case of defect products, users may return such
product to the distributor when you make the initial purchase
with the receipt or other purchase voucher that can prove the
date of purchase.
This warranty does not cover any defects and malfunction
of the product arising from any unauthorized dismantling or
reinstallation. This warranty also does not cover any defect
or malfunction that results from human factors during the
Note: This product has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This product
generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this product does cause harmful interference to radio
or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for
help.
Please take attention that changes or modication not expressly
approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions:
1. this device may not cause interference, and
2. this device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radioexempts de licence. L'exploitation
est autorisée aux deux conditions suivantes :
1. l'appareil ne doit pas produire de brouillage, et
2. l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
Under Industry Canada regulations, this radio transmitter may
only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type and its
gain should be so chosen that the equivalent isotropically radiated
power (e.i.r.p.) is not more than that necessary for successful
communication.
Conformément à la réglementation d'Industrie Canada, le présent
émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou
inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le
but de réduire les risques de brouillage radioélectrique à l'intention
des autres utilisateurs, il faut choisir le type d'antenne et son gain
de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.)
ne dépasse pas l'intensité nécessaire à l'établissement d'une
communication satisfaisante.
After the laboratory measurement, the SAR value (0.0085W/kg for
Europe, 0.029W/kg for North American) satises the RF exposure
requirement
To satisfy RF exposure compliance the user should operate the
device as the User Manual introduced and the antenna(s) used for
this transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.
Indoor Air Quality (IAQ) x 1; Product Manual x 1; USB cable
x 1; Warranty card x 1
Indoor Air Quality (IAQ)
Data line
Product Manual
Warranty card
data to be updated. Please therefore ensure that it is always
connected to network.
Charging is prohibited if the temperature is below zero
degrees.
The device collects data using the fan intake. As such it is
normal for the device to emit soft noises.
Please keep the device far away from strong magnetic
environment. This will interfere with its built-in sensor (e.g.
PM2.5 sensor).
If the device is unable to connect to the network it could
be because of improper mDNS and DHCP functions in the
router. Please check whether these functions in the router are
operating normally or restart the router before trying to link to
the network.
warranty period. Honeywell’s sole responsibility is to repair or
replace the product based on the aforesaid provisions.
Honeywell shall not be responsible for any loss or damage
of any form, including any accidental or necessary direct or
indirect loss as a result of breach of any warranty or any other
acts that damage the product.
This warranty represents the only explicit guarantee as
undertaken by Honeywell with respect to such products. Any
implied guarantee, including implied guarantees with respect
to product marketability and applicability of specic usage,
shall not apply.
This warranty only applies to the main unit of the product,
and does not cover the package, manuals, consumables, or
other components susceptible to damage or consumption.
CO2
92
Rev: V 1

Navigation menu