Honeywell HAQ Indoor Air Quality Monitor User Manual

Honeywell International Inc Indoor Air Quality Monitor Users Manual

Contents

Users Manual

Download: Honeywell HAQ Indoor Air Quality Monitor User Manual
Mirror Download [FCC.gov]Honeywell HAQ Indoor Air Quality Monitor User Manual
Document ID4114410
Application IDdMtOpDm6HorxOgz7kWxtag==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize62.9kB (786269 bits)
Date Submitted2018-12-23 00:00:00
Date Available2018-12-23 00:00:00
Creation Date2018-12-06 15:00:25
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2018-12-13 14:32:35
Document TitleUsers Manual
Document CreatorPScript5.dll Version 5.2.2
Document Author: Administrator

User Man
Sensing & Internet of Things
www.sensing.honeywell.com
About the Product
The IQ%
Time
Product Code PM Formaldehyde TV CO Temp Humidity IQ% Alarm App
OC
2.5
impact of air environment elements on cognitive ability.
HAQSPA_R
Range and Precision
Product Measurement: 80 x 80 x 22(mm)
Description
100 ~ 999ug/m3
±15%
±15ug/m3
HCHO
(Formaldehyde)
0 ~2ppm
0.01ppm(resolution)
TVOC
CO
Temperature
0.12 ~ 0.99ppm
400 ~ 2,000ppm
-10 ~ 40
0.01ppm(resolution)
1ppm(resolution)
±1
Humidity
0% ~ 100%
±5%
IQ%
0 ~ 100%
1%(resolution)
PM2.5
USB Port: Micro USB
Materials: Aluminum alloy casing Screen:
Detection Range Precision/Resolution
<100ug/m3
Weight: 156g
OLED Touch screen
Input Voltage: 5V
Input Current: 1A
Battery: 18,650 lithium-ion battery Battery
Wireless connection: Wi-Fi IEEE 802.11 b/g/n 2.4GHz
Capacity: 2,600mAh
Equipment requirements: Supports mobile phones with Android 4.42 or iOS
8.0 or better
Note: Supports only iPhone5 and later versions
App Download
Scan the
Network Connection
or search Honeywell IAQ in Apple
Store and Android Market
App Icon and Instructions on Colors
PM2.5
HCHO
0 ~ 79ug/m3
< 0.08ppm
80 ~ 199ug/m
> 200ug/m
TVOC
< 0.38ppm
IQ%
CO 2
< 1,000ppm
—
—
—
>0.08ppm
>0.38ppm
>1,000ppm
About App Functions
Self-de GJned alarmT value: Default alarm value is factory
•
setting. For threshold please see explanation above for
App icon. The user can def i ne alarm value according
to
own needs. The equipment’s indicator light
and App on the user’s mobile phone will display in
accordance
>60%
—
<60%
•
Alarm clock: 3 alarms can be set for each device while
it is connected to the network. If the alarm rings
simply touch the screen or press the Home button
Note: Air quality of PM2.5 and IQ% are showed through the change of font
The
color accordingly .
activity.
Mode and Setting
Sleep mode: The screen and indicator light will extinguish
during set time durations and the frequency of data collection
will reduce to once per hour. Switch the mode using the App
network.
if the device is connected to
CO2 manual calibration:
•
Carry the device outdoors, switch to the CO2 icon, and
then press and hold the center of the screen for 3
seconds until the phrase “being calibrated” appears on
the screen and the device enters calibration mode.
Energy-saving mode: The frequency of data collection for
the device will reduce to once per hour. Switch the mode
using the App if the device is connected to
network.
•
Place the device outdoors for 20 minutes continuously
until the phrase “being calibrated” disappears, which
means the device will automatically exit the calibration
mode upon completing calibration.
CO2 automatic calibration:
Enable: The device will automatically calibrate and exit
•
energy savings mode after continuous operation for 60
days. This calibration will be completed in 28 hours.
nterface Instructions
•
•
•
•
Enter the main interface after activating the device.
Press the icon light to switch to main screen; it will
show real-time air
value.
Flashing icon indicates excess values.
92
92
Device indicator light and color: The device’s indicator light
shows the current air quality indicator for the detection item
Detection
Item
Green
Orange
Red
PM2.5
0 ~ 79ug/m3 80 ~ 199ug/m3 ≥200ug/m3
Formaldehyde
< 0.08ppm
—
TVOC
< 0.38ppm
—
> 0.38ppm
CO 2
< 1,000ppm
—
> 1,000ppm
—
—
~ 40
> 0.08ppm
Temperature
-10
Humidity
0% ~ 100%
—
—
IQ%
> 60%
—
< 60%
Packing List
Attention
Indoor
•
; Product Manual x 1; USB
cable x 1
92
•
Indoor Air Quality (IAQ)
Product Manual
•
To better reflect the true air environment, we recommend
continuously monitoring the average values on the app. It
is recommended that the device be charged for 24 hours
continuously the first time you use it, so that it can be
initialized.
As a protective measure, the powered off device will
continue to provide a weak current to the sensor. Even if
fully charged, the device will drain the power if it is not used .
for a long period of time and must be recharged before
being used again.
When charged, the device will have a slightly higher
temperature even at a low power level. The temperature of
the fully charged device will not be affected even if it
remains connected to its power supply.
Warranty
•
Note when detecting formaldehyde/TVOC: Due to its
packaging, the device will display a higher reading when in
use for the first time, which is normal. The device may be
placed in a well-ventilated area until the reading drops
down to 0.08 ppm before use. The formaldehyde/TVOC
sensor is an electrochemical sensor. Due to the effects from
its electrochemical properties, detection of formaldehyde/TVOC by the electrochemical sensor will be affected by any
substance that contains toluene, benzene, alcohol, acetic
acid, hydrogen sulfide, carbon monoxide. Please keep the
device away from substances such as wine, perfume,
cosmetics, pesticides, etc. when in use.
•
The date and time settings of the device can only be
updated when connected to the internet. Please keep the
device connected to the internet.
Do not charge when the temperature falls below zero.
The device collects data from incoming air through the
built-in fan. It is normal for the device to make low levels of
sound.
When in use, keep the device away from any strong magnet
field which may interfere with the built-in sensor (such as
PM2.5 sensor).
If the device fails to connect to the internet, the mDNS and
DHCP of the router may experience issues. Please check that
these two router functions are enabled or reboot the router
to reconnect.
We recommend that the router’s default IP address range be
192.168.X.X. with the gateway as 192.168.1.1.
•
•
•
•
•
Under circumstances where the product is in normal use
and maintenance, Honeywell provides users with the
warranty that this product will have no defects in processing
or materials within one (1) year following the date of
purchase. Where Honeywell verifies such product
experiences any defect or malfunction in any form within
the specif i ed warranty period, Honeywell will repair or
replace any defective product upon verif i cation. In case of
defective products, users may return such product to the
distributor where they made the original purchase.
•
This warranty does not cover any defects and malfunction of
the product arising from any unauthorized dismantling or
reinstallation. This warranty also does not cover any defect
or malfunction that results from human factors during the
warranty period. Honeywell’s sole responsibility is to repair
or replace the product based on the aforesaid provisions.
•
Honeywell shall not be responsible for any loss or damage of
any form, including any accidental or necessary direct or
indirect loss as a result of breach of any warranty or any
other acts that damage the product.
•
This warranty represents the only explicit guarantee as
undertaken by Honeywell with respect to such products.
Any implied guarantee, including implied guarantees with
respect to product marketability and applicability of specific
usage, shall not apply.
•
This warranty only applies to the main unit of the product,
and does not cover the package, manuals, consumables, or
other components susceptible to damage or consumption.
FCC Statements
Note: This product has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This product
generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this product does cause harmful interference to radio
or television reception, which can be determined by turning the
equipment o and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit di erent from
that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for
help.
Please take attention that changes or modification not expressly
approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
—Reorient or relocate the receiving antenna.
IC Statements
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions:
1. this device may not cause interference, and
2. this device must accept any interference, including interference
that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada
applicables aux appareils radioexempts de licence. L'exploitation
est autorisée aux deux conditions suivantes :
1. l'appareil ne doit pas produire de brouillage, et
2. l'utilisateur de l'appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d'en
compromettre le fonctionnement.
Under Industry Canada regulations, this radio transmitter may
only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type and its
gain should be so chosen that the equivalent isotropically radiated
power (e.i.r.p.) is not more than that necessary for successful
communication.
Conformément à la réglementation d'Industrie Canada, le présent
émetteur radio peut
fonctionner avec une antenne d'un type et d'un gain maximal (ou
inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le
but de réduire les risques de brouillage radioélectrique à l'intention
des autres utilisateurs, il faut choisir le type d'antenne et son gain
RF Exposure
de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.)
ne dépasse pas l'intensité nécessaire à l'établissement d'une
communication satisfaisante.
After the laboratory measurement, the SAR value (0.0085W/kg for
Europe, 0.029W/kg for North American) satisfies the RF exposure
requirement
To satisfy RF exposure compliance the user should operate the
device as the User Manual introduced and the antenna(s) used for
this transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.
Caution
HAQSPA_R are in
Risk of explosion if battery is replaced by an incorrect type. Dispose
of used batteries according to the instructions
Honeywell International Inc. a
r. H
erve
e ri
iy
o e an
wit
II w t
HII i
ot r
ter
ntione
are t
eir re ective co
e Inc.
al
owne
nt any co
ca
it
nt
HII.
o i le or any tec
rovi
nti
ical
aterial. HII i
ot
er
etary i
t. All
not allow
oco y
ion conta
rv
or written co ent
. it
article i
rotect
HII
y or tran ation into ot
Rev: V 3
HAQSPA_R| Dec 2018
© 2018 Honeywell International Inc.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Format                          : application/pdf
Title                           : 
Creator                         : Administrator
Create Date                     : 2018:12:06 15:00:25+08:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2018:12:13 14:32:35+08:00
Metadata Date                   : 2018:12:13 14:32:35+08:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:24f522bb-25a3-480b-85ec-f41613e64fda
Instance ID                     : uuid:419ba819-b1c9-8441-be2f-c74abc620612
Page Count                      : 2
Author                          : Administrator
EXIF Metadata provided by EXIF.tools
FCC ID Filing: HD5-HAQ

Navigation menu