Honeywell HE365B User Manual HUMIDIFIER Manuals And Guides L1002583
HONEYWELL Humidifier Manual L1002583 HONEYWELL Humidifier Owner's Manual, HONEYWELL Humidifier installation guides
User Manual: Honeywell HE365B HE365B HONEYWELL HUMIDIFIER - Manuals and Guides View the owners manual for your HONEYWELL HUMIDIFIER #HE365B. Home:Heating & Cooling Parts:Honeywell Parts:Honeywell HUMIDIFIER Manual
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Honeywell ra E,. nvi HE365A,B PoweredFlow-ThroughHumidifier TRADELINE ® READAND SAVE THESE INSTRUCTIONS APPLICATION H The Enviracaire Elite TM HE365A, B Powered Flow-Through Humidifier works with the warm air furnace blower to provide humidification for the whole house. The HE365A, B works with virtually any Honeywell humidity control, and can be integrated to the temperature control in the home when controlled by the Honeywell Perfect Climate Comfort Center TM control. M12813 Fig. 4. Position securing clips. INSTALLATION 7. Position the humidifier housing in the hole (be sure it is level), so the locking tabs are in place on the upper and lower sheet metal edge of the hole. 8. Push in securing clips until completely seated. 9. Drill holes and install the three sheet metal screws at the top of the humidifier housing. Secure the housing with the three remaining screws. 10. Reinstall the humidifier pad assembly in the humidifier housing. When Installingthis Product... 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as //_provided M12808 Fig. 1. Typical humidifier installation locations. in these instructions. ([ CAUTION m -o Hazardous Voltage. Improper drilling can cause equipment damage or personal injury. Do not cut or drill into any air conditioning or electrical r- )> m 11. Hook the top of the cover to the housing and secure with the thumbscrew located at the bottom of the cover. /\ / Freezing Water, Flooding or Static Pressure Hazard. Can cause water damage or permanent equipment damage. • Locate the humidifier where the ambient temperature is between 32°F (0°C) and 160°F (71°C) or property damage can occur. • Do not install humidifier where freezing temperatures could occur. • Be sure supply plenum static pressure is no greater than 0.4 in. wc and water pressure is no greater than 125 psi. \ \ \ WARNING \ I I MI2812 Fig. 2. HE360 Humidifier location in relation to air conditioning cooling coils. Voltage Hazard. Moving parts can cause electrical shock and injury. • Disconnect power supply before installation or servicing. • This device contains a moving fan blade; do not operate the humidifier without the cover securely attached. All wiring must comply with applicable local codes, ordinances and regulations. FEED TUBE WATER DISTRIBUTION For H808 Humidistat, H8908 or H908 Convertible Humidity Control Wiring Connections: HUMIDIFIER PAD IMPORTANT • Mount the humidifier at least 3 in. (76 mm) above the furnace jacket to allow adequate space for the drain line. Check that there is adequate space above the humidifier to remove and install the humidifier cover. Do not install on a fumace jacket. IMPORTANT • Select models of fan centers include humidifer taps so the current sensing relay or sail switch is not needed. • If not using a current sensing relay or sail switch, the 120V humidifier plug must be energized during blower motor cycles for proper operation. 1. Determine the best location for the humidifier and draw a level line on the plenum. See Fig. 1 and 2. IMPORTANT To assure optimal product performance, is level before marking. --I \ / / CAUTION ,< ILl I-- WIRING /\ / accessory. ILl I-n / Z_ IMPORTANT For proper operation, be sure the mark on the end of the humidifier pad is facing up. Check that the water feed tube is placed in the guide slots of the humidifier housing. be sure the template HUMIDIFIER HOUSING "_"_COVER 1. Wire the current sensing relay or sail switch. 2. Connect only the two yellow wires to the humidistat (red wire connections are not used for mechanical humidistats). See the typical wiring diagrams in Fig. 5 through 7. ASSEMBLY 2. Tape this piece of paper in position as your template and trace around the template. 3. Remove the template and carefully cut the rectangular opening. 4. Loosen the thumbscrew on the bottom of the humidifier and remove the cover. 5. Remove the humidifier pad assembly by grasping the top of the tray and pulling the assembly out of the housing. See Fig. 3. 6. Position the securing clips as shown in Fig. 4. ® U.S. Registered Trademark Copyright © 2000 Honeywell For additional mounting and wiring information, installation instructions. refer to the humidistat Fig. 3. Humidifier components. IIII IIIII IIIIIII II 69-1428 • All Rights Reserved TEMPLATE TO BLOWER MOTOR IGNITION BOX For H1008 Automatic Humidity Control wiring connections: p 120vAo IMPORTANT • Current sensing relay or sail switch is not needed with the Automatic Humidity Control. • Use 18-22 gauge insulated wire forproper wiring. We recommend stranded - tinned wire. A ' A ',1 IMECHANtCALI HUM,DISTAT |_ HUMIDIF,ER "4__ YELLOW WIRES Z_POWER SUPPLY. PROVIDE DISCONNECT OVERLOAD PROTECTION AS REQUIRED. Z_24V MEANS AND 2. NOTE: c. WIRING. 1. Connect 24 Vac power to the 24 Vac HOT and COM terminals on the H 1008A. 2. Connect the humidifier to the two HUM terminals on the H1008A as shown in Fig. 8. M12686 Fig. 5. Typical wiring diagram for humidifier using fan control to cycle blower motor fan and humidifier simultaneously. HU MIIDtSTAT For additional mounting and wiring information, Control installation instructions. A | refer to the Humidity /2_ HUMIDIFIER _ YELLOW /_ //_ For Perfect Climate Comfort Center TM Control connections: Z_ 120 VAC p 1. Connect only the two yellow wires to the W8900 (red wire connections are not used). See the typical wiring diagram in Fig. 9. WIRES For additional mounting and wiring information, refer to the Perfect Climate Comfort Center installation instructions. POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. TM PlumbingSaddleValve 24V WIRING. Mt2684 Fig. 6. Typical wiring diagram of current sensing relay with humidifier. I MECHANICAL_ Hot or cold water, either hard or softened, can be used in the humidifier. 1. Use the self-piercing saddle valve (included) to tap into the water supply line at an appropriate location. /k H UMIDtS_L_ _::::::_ 120 VAC A POWER SUPPLY PROV,DE DISCONNECT s A2ES ,. O/ERLOAD PROTECT,ON Z_24V Fig. 7. Typical wiring WIRING. diagram M12685 of sail switch with humidifier. Slope hose downward for correct drainage. Connect a 1/2 in. hose to the humidifier drain fitting and run it to a suitable drain. CHECKOUT 1. Open the saddle valve. NOTE: The furnace blower must be on for the humidifier to operate. 2. Set the thermostat setpoint 10°F (6°C) above the room temperature. 3. Set the convertible humidity control to a high humidity setting, or place the H1008AAutomatic Humidity Control in the test position. 4. Observe the water running out of the drain line to be sure the humidifier is working correctly. 5. Check for leaks. 6. Reset the thermostat to a comfortable setting or the Automatic Humidity Control to the desired frost factor setting. CAUTION _) PC8900 Chemical Hazard. Can cause personal injury or equipment damage. Do not use any line connected to an air conditioner. E,,OWW, ES 1 LN..za Do not over-tighten the compression nut. Moderate tightness prevents leaking. Insert the tubing into the solenoid valve fitting and support the valve while tightening the compression nut. NOTE: 3. I MECHANICAL_ Use 1/4 in. O.D. copper tubing and connect the saddle valve to the inlet side of the solenoid valve. a. Place the brass compression nut over the copper tubing. b. Slide the brass ferrule over the tubing. Lightly clean the copper tubing ends with fine sandpaper before making any connections. ® A OPTIONAL OUTDOOR AIR SENSOR ® ® 1@ IMPORTANT • The saddle valve is not designed to regulate water flow, the valve is either open or closed. • To prevent debris from clogging the solenoid in-line filter, be sure to install the saddle valve handle pointing toward the ceiling. NOTE: W8900B CO2 $ _OUT ® _HE36O I ®1 LED ® O/B @G RH___ 120 /3\ >L $ ux _w2 ®1 ROOM THERMOSTAT A Z_ POWER SUPPLY. PROVIDE DISCONNECT PROTECTION AS REQUIRED. Z_ OPTIMAL Z_RED CONTROL WIRES ACHIEVED ARE NOT USED WHEN MEANS AND OVERLOAD USING OUTDOOR tN THIS APPLICATION. AIR SENSOR. MI2819A Fig. 9. Typical wiring diagram for humidifier using PC8900/W8900. 120 VAC A FURNACE TRANSFORMER L1 (HOT) AUTOMATIC CONNECTO_ HUMIDITY CONTROL FROST FACTOR SETPOINT DIAL SOLENOID Z_ Z_ POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. Z_ 24v WIRING HEAT ONLY APPLICATIOtN SHOWN. SIMILAR WIRING REQUIRED tN HEAT AND COOL SYSTEM WITH ONE OR TWO TRANSFORMERS. M12820B Fig. 8. Typical wiring diagram for humidifier using H1008A Automatic Humidity Control. Honeywell Home and Building Control Honeywell and Building Honeywell 1985 Douglas Golden Home Drive Valley, North MN 55422 35 Dynamic Scarborough, MIV 429 Control Limited-Honeywell Limitde Drive Ontario _rt Printed 69-1428 G.H. 8-00 in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. www.honeywell.com/yourhome/
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 2 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 4, 0, 0, 13 Create Date : Sun Mar 07 04:12:09 2010 Author : Title : Subject :EXIF Metadata provided by EXIF.tools