Honeywell HE365B1004 User Manual HUMIDIFIER Manuals And Guides L0612226
HONEYWELL Humidifier Manual L0612226 HONEYWELL Humidifier Owner's Manual, HONEYWELL Humidifier installation guides
User Manual: Honeywell HE365B1004 HE365B1004 HONEYWELL HUMIDIFIER - Manuals and Guides View the owners manual for your HONEYWELL HUMIDIFIER #HE365B1004. Home:Heating & Cooling Parts:Honeywell Parts:Honeywell HUMIDIFIER Manual
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Honeywell envi ra E,. HE365A,B PoweredFlow-ThroughHumidifier TRADELINE ® READ AND SAVETHESEINSTRUCTIONS APPLICATION IvH The Enviracaire Elite TM HE365A, B Powered Flow-Through Humidifier works with the warm air furnace blower to provide humidification for the whole house. The HE365A,B works with virtually any Honeywell humidity control, and can be integrated to the temperature control in the home when controlled by the Honeywell Perfect Climate Comfort Center TM control. MI2813 Fig. 4. Position INSTALLATION 7. Position the humidifier housing in the hole (be sure it is level), so the locking tabs are in place on the upper and lower sheet metal edge of the hole. 8. Push in securing clips until completely seated. 9. Drill holes and install the three sheet metal screws at the top of the humidifier housing. Secure the housing with the three remaining screws. 10. Reinstall the humidifier pad assembly in the humidifier housing. When Installingthis Product... 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as //_provided CAUTION "O Hazardous Voltage. Improper drilling can cause equipment damage or personal injury. Do not cut or drill into any air conditioning or electrical accessory. I-- -I 131 /k Fig. 1. Typical humidifier installation locations. in these instructions. "4 Ill securing clips. IMPORTANT For proper operation, be sure the mark on the end of the humidifier pad is facing up. Check that the water feed tube is placed in the guide slots of the humidifier housing. LLI 11. Hook the top of the cover to the housing and secure with the thumbscrew located at the bottom of the cover. rt ILl / // WIRING x \x / // CAUTION ( Freezing Water, Flooding or Static Pressure Hazard. Can cause water damage or permanent equipment damage. • Locate the humidifier where the ambient temperature is between 32°F (0°C) and 160°F (71 °C) or property damage can occur. • Do not install humidifier where freezing temperatures could occur. • Be sure supply plenum static pressure is no greater than 0.4 in. wc and water pressure is no greater than 125 psi. --I \ WARNING x\ h MI28/2 Fig. 2. HE360 Humidifier location in relation to air conditioning cooling coils. Voltage Hazard. Moving parts can cause electrical shock and injury. • Disconnect power supply before installation or servicing. • This device contains a moving fan blade; do not operate the humidifier without the cover securely attached. All wiring must comply with applicable local codes, ordinances and regulations. FEED TUBE NOZZLE WATER For H808 Humidistat, H8908 or H908 Convertible Humidity Control Wiring Connections: HUMiDIFiER IMPORTANT • Mount the humidifier at least 3 jacket to allow adequate space there is adequate space above instafi the humidifier covet: Do IMPORTANT • Select models of fan centers include humidifer taps so the current sensing relay or sail switch is not needed. • If not using a current sensing relay or sail switch, the 120V humidifier plug must be energized during blower motor cycles for proper operation. in. (76 mm) above the furnace for the drain line. Check that the humidifier to remove and not instafi on a furnace jacket. 1. Determine the best location for the humidifier and draw a level line on the plenum. See Fig. 1 and 2. IMPORTANT To assure optimal product is level before marking. performance, be sure the template HUMIDIFIER HOUSING THUMB 2. Tape this piece of paper in position as your template and trace around the template. 3. Remove the template and carefully cut the rectangular opening. 4. Loosen the thumbscrew on the bottom of the humidifier and remove the cover. 5. Remove the humidifier pad assembly by grasping the top of the tray and pulling the assembly out of the housing. See Fig. 3. 6. Position the securing clips as shown in Fig. 4. ® U.S. Registered Trademark Copyright © 2000 Honeywell SOREW-x . 1. Wire the current sensing relay or sail switch. 2. Connect only the two yellow wires to the humidistat (red wire connections are not used for mechanical humidistats). See the typical wiring diagrams in Fig. 5 through 7. For additional mounting and wiring information, installation instructions. refer to the humidistat Fig. 3. Humidifier components. IIIII IIIIIIIIIII 69-1428 • All Rights Reserved TEMPLATE A HUMID I MECHANICAL IGNITION BOX IMPORTANT YELLOW WIRES POWER SUPPLY• PROVIDE DISCONNECT OVERLOAD PROTECTION AS REQUIRED A24V MOTOR HUMIDIFIER _-A For H1008 Automatic Humidity Control wiring connections: TO BLOWER A MEANS • Current sensing relay or sail switch Automatic Humidity Control. • Use 18-22 recommend AND WIRING• gauge insulated wire for proper stranded - tinned wire. M/2686 For additional mounting and wiring information, Control installation instructions. _ wiring. with the refer to the Humidity 120VAC For Perfect Climate Comfort Center TM Control connections: 1. Connect only the two yellow wires to the W8900 (red wire connections are not used). See the typical wiring diagram in Fig. 9. YEL For additional mounting and wiring information, refer to the Perfect Climate Comfort Center TM installation instructions. ED. BLOWER _. MOTOR J A PlumbingSaddleValve 24V WIRING V M/2684 Fig. 6. Typical wiring diagram of current sensing relay with humidifier. _ 12BVAC WIRING• c. CHECKOUT 1. Open the saddle NOTE: The furnace blower must be on for the humidifier to operate. B PC8900 The saddle valve is not designed to regulate water flow, the valve is either open or closed. To prevent debris from clogging the solenoid in-line filter, be sure to install the saddle valve handle pointing toward the ceiling. NOTE: valve. 2. Set the thermostat setpoint 10°F (6°C) above the room temperature. 3. Set the convertible humidity control to a high humidity setting, or place the H1008AAutomatic Humidity Control in the test position. 4. Observe the water running out of the drain line to be sure the humidifier is working correctly. 5. Check for leaks. 6. Reset the thermostat to a comfortable setting or the Automatic Humidity Control to the desired frost factor setting. IMPORTANT Fig. 7. Typical wiring diagram of sail switch with humidifier. Slope hose downward for correct drainage. 3. Connect a 1/2 in. hose to the humidifier drain fitting and run it to a suitable drain. Chemical Hazard. Can cause personal injury or equipment damage. Do not use any line connected to an air conditioner. MI2685 Do not over-tighten the compression nut. Moderate tightness prevents leaking. Insert the tubing into the solenoid valve fitting and support the valve while tightening the compression nut. NOTE: CAUTION YELLOW W,RES APOWERSUPPLY PROV, DE O,SOONNEOT s% A%O/ERLOAD PROTECT,ON A24V can be used in the 1. Use the self-piercing saddle valve included) to tap into the water supply line at an appropriate location. A sv%H Hot or cold water, either hard or softened humidifier. NOTE: We 1. Connect 24 Vac power to the 24 Vac HOT and COM terminals on the H1008A. 2. Connect the humidifier to the two HUM terminals on the H1008A as shown in Fig. 8. Fig. 5. Typical wiring diagram for humidifier using fan control to cycle blower motor fan and humidifier simultaneously. l c, Is'C#lA is not needed 2. Use 1/4 in. O.D. copper tubing and connect the saddle valve to the inlet side of the solenoid valve. a. Place the brass compression nut over the copper tubing. b. Slide the brass ferrule over the tubing. ® W8900B ,_$1 CO2 L@ ® ® A OPTIONAL OUTDOOR AIR SENSOR _OUT _LED ® __O/B a® RH® ' -_Y2 f3,Yt/W 120"_I°'P'E_ __ HUM ® Lightly clean the copper tubing ends with fine sandpaper before making any connections. ROOM THERMOSTAT ® r_L A t __AUX __W2 VNT@ VNT®. ® @ APOWER SUPPLY• PROVIDE DISCONNECT PROTECTION AS REQUIRED. A ARED OPTIMAL CONTROL WIRES ACHIEVED ARE NOT USED WHEN MEANS AND OVERLOAD USING OUTDOOR IN THIS APPLICATION. Fig. 9. Typical wiring diagram for humidifier AIR SENSOR• MI2819A using PC8900/W8900. 120 VAC A FURNACE TRANSFORMER L1 (HOT) AUTOMATIC CONNEDTO_ HUMIDITY POWER SUPPLY AND OVERLOAD A24V FROST FACTOR SETPOINT DIAL SOLENOID A A CONTROL PROVIDE DISCONNECT MEANS PROTECTION AS REQUIRED. HEAT ONLY APPUDATIOIN SHOWN SIMILAR WIRING REQUIRED IN HEAT AND COOL SYSTEM OR TWO TRANSFORMERS WITH ONE MI2820B WIRING. Fig. 8. Typical wiring diagram for humidifier using H1008AAutomatic Humidity Control. Honeywell Home and Building Control Honeywell 69-1428 and Building Honeywell 1985 Douglas Golden Home Drive Valley, G.H. North 35 Dynamic MN 55422 Scarborough, M1V 429 8-00 Control Limited-Honeywell Limitde Drive Ontario _rt Printed in U.S.A on recycled paper containing at least 10% post-consumer paper fibers• www.honeywell.com/yourhome/
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 2 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Fri Apr 20 15:54:35 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools