Honeywell HX2 Quick Start Guide User Manual To The 49256973 69bd 4892 B95c 3162480794b2
User Manual: Honeywell HX2 to the manual
Open the PDF directly: View PDF .
Page Count: 16
Download | ![]() |
Open PDF In Browser | View PDF |
HX2 Wearable Computer With Microsoft Windows® CE 5.0 Operating System Quick Start Guide HX2-QS Rev A 4/12 HX2 Rugged Wearable Computer Components - Front Components - Back Armband Assembly Assemble Armband and Secure On Arm Attach Battery Cable to HX2 Trigger Rotation Attach Ring to Finger Attach Ring Cable to HX2 Attach HX2 to Armband Final Assembly Removing HX2 from Armband Proper Scanning Technique Connecting Battery and Audio Cable Attaching Headset to HX2 Hip Flip Desktop Cradle Battery Multi-Charger Remove Ring Strap Module Replace Ring Strap Module Remove Trigger Module Replace Trigger Module Setting up the HX2 Please have the following Information available before setting up your HX2: l Network ID (SSID) of the Access Point l WEP key or LEAP authentication credentials 1. Connect a fully charged battery to the HX2. 2. Press the Power button. 3. Accept the EULA. 4. Calibrate the touch screen. 5. Set the date and time. 6. Edit the radio parameters. 7. Edit the RFTerm Terminal Emulation parameters (optional). 8. Perform a reboot. Rebooting the HX2 Using the Start menu, select Start > Run and type warmboot in the text box. Press Enter. When the HX2 is booting, there may be small delays while the wireless client connects, applications launch, remote management completes and Bluetooth devices connect. Bluetooth and HX2 Please refer to the HX2 Reference Guide for information when using the HX2 with Bluetooth. ActiveSync Installing ActiveSync on Desktop/Laptop ActiveSync (version 4.5 or higher for Windows XP desktop/laptop computers) must be resident on the host (desktop/laptop) computer. Windows Mobile Device Center is required for a Windows Vista/Windows 7 desktop/laptop computer. ActiveSync and Windows Mobile Device Center for the PC are available from the Microsoft website. Follow Microsoft's instructions to locate, download and install ActiveSync or Windows Mobile Device Center on your desktop/laptop. ActiveSync using USB-Client Connection The only connection type is USB Client. 1. Connect the HX2 end of the cable to the connector on the bottom of the HX2. 2. Connect the USB type A connector on the I/O cable to a USB port on a PC or laptop. ActiveSync starts automatically when the USB cable is connected. When the HX2 loses connection (e.g., enters Suspend Mode), the connection to ActiveSync is lost. When the HX2 resumes, disconnect the PC end of the cable and reconnect. Please refer to the HX2 Reference Guide for ActiveSync information. Setting Up the Radio If the access point uses an authentication protocol (WEP, LEAP, etc.), your radio must use the same authentication. Please contact your IT department for WEP keys or LEAP credentials. Please refer to the HX2 Reference Guide for information on using WPA. 1. Tap Start > Programs > Summit > SCU OR tap the Summit Client Utility icon on the desktop. 2. Tap the Admin Login button and enter the password (default = SUMMIT). 3. Tap the Profile tab and make sure the Default profile is selected. 4. Select SSID and enter your SSID value. 5. If the access point is using WEP, select WEP from the Encryption pull down list. 6. Tap the WEP keys/PSKs button and enter the WEP Key(s) and tap OK. Skip to step 12. 7. If the access point is using LEAP, select LEAP from the EAP Type pull down list. 8. Select WEP EAP from the Encryption pull down list. 9. If the Cisco/CCS certified AP is configured for open authentication, set the Auth Type radio parameter to Open. 10. If the AP is configured for network EAP only, set the Auth Type radio parameter to LEAP. 11. Tap the Credentials button and enter the User Name and Password. 12. Tap the Commit button to save the radio configuration. 13. Tap the Main tab. Wait for a radio connected message. 14. Tap the Admin Logout button when finished. 15. Reboot the HX2. Please refer to the Radio Mode parameter in the HX2 Reference Guide. It is important that this parameter setting corresponds to the Access Point to which the HX2 connects. Setting Up AppLock HX2 devices are shipped to boot in Administration mode. In this mode, the user has full access to the device and no password is needed. After the administrator completes the process below, the HX2 switches to end-user mode and restricts access to only the specified application(s). 1. Tap Start > Settings > Control Panel > Administration icon. 2. Assign application(s) on the Application tab screen. 3. Assign a password on the Security tab screen. 4. Select a view level on the Status tab screen, if desired. 5. Tap OK. 6. Press the hotkey (Ctrl + Shift + A) sequence to launch AppLock and lock the configured application(s). 7. The device is now in end-user mode. Connecting Using RFTerm Before you make a host connection, you will, at a minimum, need to know: l the alias name or IP address (Host Address) and l the port number (Telnet Port) of the host system to properly set up your host session. 1. Make sure the mobile client network settings are properly configured. If you are connecting via WLAN (802.11x), make sure your HX2 is connected to the network. 2. Launch RFTerm by tapping the RFTerm icon on the desktop. 3. Select Session > Configure from the application menu and select the host type. This is dependent on the host system to which you are connecting; i.e., 3270 mainframe, AS/400 5250 server or VT host. 4. Enter the Host Address of the system. This may either be a DNS name or an IP address of the host system. 5. Update the telnet port number if your host application is configured to listen on a specific port. If not, use the default telnet port. 6. Select OK. 7. Select Session > Connect from the application menu or tap the Connect button on the Tool Bar. 8. Upon a successful connection, the host application screen is displayed. To change options (e.g., Display, Colors, Cursor, Barcode), please refer to the RFTerm Reference Guide for descriptions of these and other features. Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII. HII shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This document contains proprietary information that is protected by copyright. All rights are reserved. © 2007-2012 Honeywell International Inc. All rights reserved. Other product names or marks mentioned in this document may be trademarks or registered trademarks of other companies and are the property of their respective owners. Web Address: www.honeywellaidc.com Patents For patent information, please refer to www.honeywellaidc.com/patents. Technical Assistance Contact information for technical support, product service, and repair can be found at www.honeywellaidc.com. Limited Warranty Refer to www.honeywellaidc.com/warranty_information for your product’s warranty information. User Documentation To download the HX2 user documentation go to www.honeywellaidc.com.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Creator : Honeywell Description : Title : HX2 Quick Start Guide Create Date : 2012:05:25 13:51:53-04:00 Modify Date : 2012:05:25 14:12:41-04:00 Metadata Date : 2012:05:25 14:12:41-04:00 Keywords : Producer : MadCap Flare V6 Document ID : uuid:3deaa183-a4c1-4838-995a-40c038927670 Instance ID : uuid:71db6f25-3009-44db-ada5-da9cdcc99e9f Page Mode : UseNone Page Count : 16 Author : Honeywell Subject :EXIF Metadata provided by EXIF.tools