Description

This programmable thermostat can be connected to an electric heating system such as an electric baseboard, a radiant ceiling, a floor heating system,
an electric convector, etc. It is not compatible with a central heating system.

p

The configuration switches are on the back of the thermostat. Default (factory)
settings are inside the gray cells.
#

Time and day
Appears during the
setpoint display

On/Off
switch

Preset temperature
icons

Heating
indicator

To set the day

Periods

To set the time

*

Not used
Disable

Enable

SW3

Early Start a
Time format

12-hour

24-hour

SW4

Temperature format b

°F

°C

,

and

) will return to their default settings.
4.

Power-up

Upon power-up, the thermostat is in manual mode ( ) and displays the actual
temperature.

To select the
operating mode

n
o

Set the switch to Off to cut power to the heater. This will not affect the time and temperature settings.

o

2.

Connection

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN POWER
PANEL TO AVOID ELECTRICAL SHOCK.

Press the Hour and Min buttons to set the thermostat’s clock.
Press the Day button to set the day.

r

Setpoint
The thermostat normally displays the actual temperature. To view the setpoint, press the
or
button briefly. The setpoint will appear for the next 5
seconds.

The installation must be carried out by an electrician.

•

All cables and connections must conform to the local electrical code.

•

Special CO/ALR solderless connectors must be used when connecting
with aluminum conductors.

Using a preset temperature

•

Install the thermostat onto an electrical box.

•

Install the thermostat about 5 feet high, on an inside wall facing the
heater.





•

Avoid locations where there are air drafts (such as the top of a staircase
or an air outlet), dead air spots (such as behind a door), or direct sunlight.

•

Do not install the thermostat on a wall that conceals chimney or stove
pipes.

n

Connect the thermostat wires to the
power and to the load using solderless
connectors for copper wires.

To change the setpoint, press the
or button until the desired temperature
is displayed. To scroll faster, hold the button.
The thermostat has 3 preset temperatures:
Comfort temperature
Economy temperature
Vacation temperature

Icon

Black
Power

5.

Temperature Setting

•

Load

Intended use

Default setting

Comfort (when at home)

70 °F (21 °C)

Economy (when asleep or away from home)

62 °F (16 °C)

Vacation (during prolonged absence)

50 °F (10 °C)

•

To use the Comfort or Economy temperature, press the
respectively. The corresponding icon will be displayed.
To use the Vacation temperature, press both
neously. The
icon will be displayed.

Red

o

Push the excess wire back into the
electrical box to prevent interference
with the thermostat.

•

p

Secure the thermostat using two 6-32
screws.

To store the Comfort or Economy temperature:

q

Return power to heating system.

and

or

button

buttons simulta-

Storing a preset temperature
Set the desired temperature using the

or

button. Press and hold

the appropriate button ( or ) for approximately 3 seconds until the
corresponding icon is displayed.

NOTE: Always keep the thermostat's vents
clean and unobstructed.

To store the Vacation temperature:
Load

08161 / TH110-DP-P / TL8230
Programmable Thermostat - Installation and User Guide

DN

SW2

q

To skip a period

Temperature
adjustment

UP

SW1

(

To program the schedule
Temperature
preset buttons

Configurations

a. Early Start can be used in Automatic mode only. When this function is
enabled, the thermostat calculates the optimal time to start heating in
order to obtain the desired temperature by the set time. The thermostat
re-assesses the start time daily based on the previous day’s performance.
b. If you change the temperature display format, the preset temperatures

Temperature
Operating
mode icons

3.

Configuration

Set the desired temperature using the
both
the

or

button. Press and hold

and buttons simultaneously for approximately 3 seconds until
icon is displayed. Press the Mode button.
69-2023

1/11/06

1/2

400-110-007-A_69-2023 (TH110A-DP-240 Cadet TL8230) ENG.fm Page 2 Wednesday, November 1, 2006 8:48 AM

s

6.

Operating Modes

Automatic - The temperature is set according to the energy-saving

schedule. To place the thermostat in this mode, press Mode until
is displayed. The icons of the current period and preset temperature are also displayed.
Temporary Bypass: If you modify the setpoint (by pressing the

,

,

or button) when the thermostat is in automatic mode, the new setpoint will be used until the end of the current period. When the next
period starts, the temperature set for that period becomes the new setpoint.

Manual - The energy-saving schedule is not used. The temperature must
Press Mode until

is displayed.

Set the temperature using the

,

,

or

t

buttons simultaneously to place the thermostat in Vacation mode.
7.

Energy-saving Schedule

The schedule consists of 4 periods per day which represents a typical week
day. You can program the thermostat to skip the periods that do not apply to
your situation. For example, you can skip periods 2 and 3 for the weekend.
Period

Description

Associated preset temperature

Wake-up
Away from home
Return home
Sleep
The Comfort (

) temperature is used in periods 1 and 3 and the Economy

( ) temperature is used in periods 2 and 4. For example, when the period
changes from 1 to 2, the setpoint automatically changes from Comfort setting
(

) to Economy setting ( ).

You can have a different program for each day of the week; i.e., each period
can start at different time for each day of the week. The thermostat has been
programmed with the following schedule.
Period

Setting

MO

TU

WE

TH

FR

SA

SU

6:00
AM

6:00
AM

6:00
AM

6:00
AM

6:00
AM

6:00
AM

6:00
AM

8:00
AM

8:00
AM

8:00
AM

8:00
AM

8:00
AM

--:--

--:--

6:00
PM

6:00
PM

6:00
PM

6:00
PM

6:00
PM

--:--

--:--

10:00
PM

10:00
PM

10:00
PM

10:00
PM

10:00
PM

10:00
PM

10:00
PM

To modify the schedule:

n
o

Press Pgm to access the programming mode. Period 1 is selected.

p

Press Hour and Min to set the start time of the selected period, or press
Clear if you want to skip the period (--:-- is displayed).

q

Press Pgm to select another period, or press Day to select another day.
Then repeat step 3.

r

Press Mode to exit the programming mode.

Press Day to select the day to program (hold for 3 seconds to select the
entire week).

NOTE: If no button is pressed for 60 seconds, the thermostat will automatically exit the programming mode.

08161 / TH110-DP-P / TL8230
Programmable Thermostat - Installation and User Guide

Solutions
The thermostat’s switch is set to Off.

LO is displayed.

The measured temperature is below the
display range. Heating is activated.

HI is displayed.

The measured temperature is above the
display range.

The wrong time is displayed.

The thermostat was without power for
more than 2 hours.

The measured temperature is wrong.

The thermostat is located in a spot
exposed to an air draft.

The heater is always On.

Check the thermostat wiring.

Check that the thermostat is in Automatic
The temperature does not change accordmode. Check also the energy-saving
ing to the energy-saving schedule
schedule and clock settings.

button.

Vacation - The thermostat is set to the Vacation temperature. Press both
and

Problems
The thermostat’s screen is blank.

The thermostat indicates that heating is On
Check the thermostat wiring.
but the heater is not On.

be set manually. To place the thermostat in this mode:

n
o

u

8.

Troubleshooting

v

Technical Specifications

;

Warranty

9.

Power: 208/240 Vac, 60 Hz
Maximum load: 16 A maximum (resistive only)
3328 watts @ 208 Vac
3840 watts @ 240 Vac
Display range: 32 °F to 140 °F (0 °C to 60 °C)
Display resolution: 0.1 °F (0.1 °C)
Setpoint range: 40 °F to 86 °F (5 °C to 30 °C)
Setpoint interval: 1 °F (1 °C)
Storage: -4 °F to 120 °F (-20 °C to 50 °C)
Certifications: CSA/UL
Data backup: In the event of a power outage, most settings are saved. Only the
time must be re-adjusted if the power outage lasts more than 2 hours. The thermostat will return to the mode that was active prior to the power outage.
10.

Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the
date of purchase by the consumer. If at any time during the warranty period the product is
determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell's option).
If the product is defective,
(i)
return it, with a bill of sale or other dated proof of purchase, to the place from which
you purchased it, or
(ii) call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the
determination whether the product should be returned to the following address:
Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr N, Golden Valley,
MN 55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not
apply if it is shown by Honeywell that the defect or malfunction was caused by damage
which occurred while the product was in the possession of a consumer.
Honeywell's sole responsibility shall be to repair or replace the product within the terms
stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY,
EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states
do not allow the exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON
THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE-YEAR DURATION OF THIS WARRANTY.
Some states do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary
from state to state.
If you have any questions concerning this warranty, please write Honeywell Customer
Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502. In Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic
Drive, Scarborough, Ontario M1V4Z9.



11.

Customer Assistance

If you have any questions about the operation of your thermostat, please go to
http://yourhome.honeywell.com, or call Honeywell Customer Care toll-free at 1800-468-1502.
®
As an ENERGY STAR partner, Honeywell has
determined that this product meets the ENERGY STAR
guidelines for energy efficiency.

69-2023

1/11/06

2/2



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2006:11:01 09:16:14-05:00
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2007:10:19 14:14:05-05:00
Metadata Date                   : 2007:10:19 14:14:05-05:00
Format                          : application/pdf
Creator                         : Honeywell ECC Technical Communications
Title                           : 08161, TH110-DP-P, TL8230 Programmable Thermostat
Description                     : Installation and User Guide
Document ID                     : uuid:deba64fe-33e5-4296-9b77-6984b984093a
Instance ID                     : uuid:00bf9d5a-0d26-4d4e-bc42-d7bfa347cda4
Page Count                      : 2
Subject                         : Installation and User Guide
Author                          : Honeywell ECC Technical Communications
EXIF Metadata provided by EXIF.tools

Navigation menu