Honeywell He225A Users Manual 68 0244 HE225A,B And HE265A,B|Bypass Flow Through|Humidifier
HE225A to the manual b61272cb-5980-48f2-8044-56d053015fbf
2015-01-23
: Honeywell Honeywell-He225A-Users-Manual-261609 honeywell-he225a-users-manual-261609 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 12
Download | |
Open PDF In Browser | View PDF |
HE225A,B and HE265A,B Bypass Flow-Through Humidifier whole-house air quality system PRODUCT DATA FEATURES/BENEFITS • Antimicrobial coating on pad prevents the surface growth and migration of bacteria, mold, fungus and algae on the humidifier pad. • Bold new look with blue and white styling. • Proven technology used for high performance humidification and enhanced comfort. • Preassembled for quicker installation. • Small footprint, light weight and reversible components allow easy mounting on either warm air supply or return air duct of any forced air furnace. • Interior components designed for quick maintenance and service. • Includes easy-to-use humidity control that mounts on the wall or duct for more flexible installation. • Continuous flushing reduces the frequency of maintenance in a hard water installation. APPLICATION The Enviacaire Elite HE225A,B and HE265A,B Bypass Flowthrough Humidifiers use the warm air furnace blower to provide humidification for the whole house. ® U.S. Registered Trademark Copyright © 2000 Honeywell • All Rights Reserved • AIRWATCH™ Indicator can be installed to remind homeowner to change humidifier pad. • Five-year warranty. 68-0244 HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER SPECIFICATIONS Humidifier Pad Dimensions: See Table 2. Capacity: At 120°F (49°C) plenum temperature and 0.20 static pressure drop across supply and return: HE225A,B: 12 gallons per day (gpd) or 46 liters per day (lpd). HE265A,B: 17 gallons per day (gpd) or 65 liters per day (lpd). Plenum Opening Dimensions (Height x Width): See Table 3. Summer Shut-off Damper Dimensions (Height x Width): See Table 4. Bypass Duct Opening (Diameter): 6 in. (152 mm). Electrical Ratings: 24 Vac, 60 Hz, 0.5A. Drain Connection: 1/2 in. (13 mm) I.D. plastic hose connected directly to drain fitting on unit. Humidified Area: See Table 1. Dimensions: Refer to Fig. 1 and 2. Table 1. Size Of Area That Can Be Humidified. House Description Air Changes Per Hour Loose Two HE265 Area (Up To) Sq ft Sq ft 750 Sq m 70 1,000 Sq m 93 Average One 1,500 140 2,000 186 Tight One-half 3,000 280 4,000 372 Table 4. Dimensions Of Summer Shut-off Damper In In. (mm). Table 2. Dimensions Of Humidifier Pads In In. (mm). Model Height Width Depth HE225 9-13/16 (249) 9-1/2 (241) 1-1/2 (38) HE265 HE225 Area (Up To) 13 (330) 10 (254) 1-1/2 (38) Model Height Width HE225 9-3/16 (234) 8-7/8 (226) HE265 12-3/8 (314) 9-5/16 (236) Table 3. Dimensions Of Plenum Opening In In. (mm). Model Height Width HE225 9-7/16 (241) 9-5/16 (238) HE265 12-5/8 (321) 9-3/4 (248) ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Home and Building Control Sales Office (check white pages of your phone directory). 2. Home and Building Control Customer Relations Honeywell, 1985 Douglas Drive North, MN10-1461 Golden Valley, Minnesota 55422-4386 1-800-468-1502 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarbouorgh, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 68-0244 2 HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER /8 9-1 Standard: Air Conditioning and Refrigeration Institute Tested: Standard 610. ) 32 (2 12 11 (30 -7/ 16 (29 0) Models: HE225A TRADELINE® and HE265A TRADELINE® Bypass Flow-through Humidifier package includes humidifier pad, mounting template, self-piercing saddle valve, 24 Vac transformer, H8908B Convertible Humidity Control. HE225B TRADELINE® and HE265B TRADELINE® Bypass Flow-through Humidifier package includes humidifier pad, mounting template, self-piercing saddle valve, 24 Vac transformer, H1008A Automatic Humidity Control with HumidiCalc™ Software. 5) 12 -7 (3 /16 16 ) 16 -9/ 13 45) (3 Accessories: Current Sensor Relay, part no. 32001754-001. C7089H Outdoor Temperature Sensor. H8908B Convertible Humidity Control. H1008A Automatic Humidity Control with HumidiCalc+™ Software (software calculates dewpoint to prevent moisture condensation). HC22E Antimicrobial Humidifier Pad (HE225A,B only). HC26E Antimicrobial Humidifier Pad (HE265 A,B only). HumidiCalc+™ Humidifier Sizing Software (software calculates required humidifier capacity for application). PC8900 Control. S688 Sail Switch. 6 (152) DIAMETER M14818 Fig. 1. Dimensions of HE225A,B in in. (mm). 5) 23 4( / 9-1 12 INSTALLATION (30 5) WARNING 13 -9/ 16 (34 Hazardous Voltage. Can cause personal injury or equipment damage. Do not cut or drill into any air conditioning line or electrical accessory. 5) CAUTION 15 Freezing Water, Flooding or Static Pressure Hazard. Can cause water damage to home or permanent equipment damage. • The humidifier must be located where the ambient temperature is above 32°F and below 160°F (0°C and 71°C). • Be sure supply plenum static pressure is no greater than 0.3 in. w.c. and water pressure is no greater than 125 psi. -5 (3 /16 90 ) 4 -3/ 16 5) (42 6 (152) DIAMETER IMPORTANT To assure optimal product performance, be sure the template is level before marking location. M14819 Fig. 2. Dimensions of HE265A,B in in. (mm). 1. Determine the best location for the humidifier and draw a level line on the plenum. See Fig. 3. Approvals: Underwriters Laboratories Inc. Listing: 56 BL. Canadian Underwriters Laboratories Inc. Listing: 56 BL. 3 68-0244 HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER 11. Reinstall the humidifier pad assembly in the humidifier housing. NOTE: Be sure the water feed tube is not pinched or kinked. L TA ON RIZ HO 12. Hinge the cover in place and secure with the thumbscrew located at the bottom of the cover. WATER FEED NOZZLE OY HB HIG WN DO O FL HUMIDIFIER PAD ASSEMBLY OY WB LO FRAME M12248C COVER SIDEWALL Fig. 3. Typical humidifier installation locations. IMPORTANT Mount the humidifier at least 3 in. (76 mm) above the furnace jacket to allow adequate space for the solenoid valve and drain line. Check that there is adequate space above the humidifier to remove and install the humidifier cover. 2. Tape the template in position and trace around the template. 3. Remove the template and carefully cut the rectangular opening. 4. Disassemble the humidifier; remove the cover and take out the humidifier pad assembly. See Fig. 4. HUMIDIFIER HOUSING BY-PASS SIDEWALL M14672 Fig. 4. Humidifier components. NOTE: Sidewalls are interchangeable for either left or right by-pass installation. To change direction, remove the screws holding each sidewall, switch sidewall locations and reinstall the screws. WIRING THE HUMIDIFIER CAUTION 5. Position the humidifier housing in the opening (be sure it is level), so the locking tabs are in place on the lower sheet metal edge of the opening. 6. Secure the humidifier housing to the opening at the top and bottom using sheet metal screws. 7. Locate the other plenum and cut an opening for a 6 in. (152 mm) collar. 8. Install the 6 in. (152 mm) collar. Hazardous Voltage. Can cause personal injury or equipment damage. • Disconnect the power supply before installing or servicing. • On multispeed blower applications, do not wire the high voltage side of the transformer to the same power source that services the furnace blower. Premature transformer burnout may occur. NOTE: Be sure to install a duct damper for summer shutoff on systems with air conditioning. All wiring must comply with applicable local codes, ordinances and regulations. 9. Install a 6 in. (152 mm) diameter duct from the collar to the humidifier. 1. Mount the transformer in a convenient location. 2. Connect wires to the 120V side of the transformer. 3. Wire the humidifier solenoid valve, current sensing relay, or sail switch, humidity control and transformer. Refer to the humidity control installation instructions for mounting and wiring information. NOTE: Some installations require a 90° elbow attachment to the collar. 10. Seal the duct connections with duct tape. NOTE: Select models of fan centers include humidifier taps so the current sensing relay or sail switch is not needed. NOTE: To avoid sagging and stress on the humidifier, add support when ducting is longer than 4 ft (120 cm). 68-0244 WATER FEED TUBE 4 HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER PLUMBING THE SADDLE VALVE OPERATING THE HUMIDIFIER Hot or cold water, either hard or softened, can be used in the humidifier. The HE225A and HE265A Humidifiers are controlled by the Convertible Humidity Control that is installed either on an interior wall in the living area or on the return air duct. Choose the humidity control setting using the combination relative humidity/outdoor temperature setting scale on the H8908A humidity control dial. Match the dial setting to the outdoor temperature for optimizing the humidity level while reducing the moisture condensation on inside windows. Table 5 can also be used to adjust the humidity control to the recommended setting. OUTDOOR Humidity Control Régulateur d'humidité 1. Use the self-piercing saddle valve (included) to tap into the water supply line at an appropriate location. IMPORTANT • The saddle valve is not designed to regulate water flow. The valve is either open or closed. • To prevent debris from clogging the solenoid inline filter, be sure to install the saddle valve handle pointing toward the ceiling. 2. Use 1/4 in. O.D. copper tubing and connect the saddle valve to the inlet side of the solenoid valve. NOTE: As the outside temperature drops, the recommended setting is lowered to accommodate the effects of dewpoint. These settings should reduce the accumulation of moisture and ice on the windows and in other areas of the house. CAUTION Hazardous Voltage. Can cause personal injury or equipment damage. Do not use any line connected to an air conditioner. Some indoor activities such as cooking, showering and clothes drying can cause excessive levels of humidity and start the accumulation of moisture on the windows. Place the brass compression nut over the copper tubing. NOTE: If this condition persists for more than a few hours, set the humidity control to the lowest setting to turn off the humidifier. If the condition does not improve, ventilate your home to remove the moisture. NOTE: Do not over tighten the compression nut. Moderate tightness prevents leaking. b. c. HUMIDITY SETTING 15% 20% 25% 30% 35% 40% M14694 NOTE: Lightly clean the copper tubing ends with fine sandpaper before making any connections. a. TEMPERATURE -30 °C -20 °F -25 °C -10 °F -20 °C 0 °F -10 °C +10 °F -5 °C +20 °F Over 0 °C Over 20 °F Slide the brass ferrule over the tubing. Insert the tubing into the solenoid valve fitting and support the valve while tightening the compression nut. The Enviracaire Elite HE225B and HE265B Humidifiers are controlled by the Honeywell H1008A Automatic Humidity Control with HumidiCalc+ Software. The automatic humidity control is mounted in the return air duct where it can be exposed to the air stream of the return air. The HumidiCalc+ Software M12817 H1008A inside the automatic humidity control is designed to automatically adjust the humidity level based on indoor temperature and humidity, inferred or measured outdoor temperature, and the setting of the frost factor dial. The frost factor allows for variations in furnace size, window insulation and average daily climate temperature. 3. Connect a 1/2 in. (13 mm) drain tube to the humidifier drain fitting and run to a suitable drain. NOTE: Slope the drain tube downward for correct drainage. CHECKING THE INSTALLATION Use the following procedure to check out the humidifier installation: 1. Open the saddle valve. 2. Set the thermostat setpoint to 10°F (6°C) above the room temperature. The Automatic Humidity Control with HumidiCalc+ Software requires an initial adjustment period. Set the frost factor dial on 5 and use Table 6 to adjust the frost factor—only one setting at a time—increasing the dial setting for more humidity, or reducing the setting if moisture develops on inside windows. For more precise humidity adjustment, set the frost factor between dial settings. Allow two days for the humidity level to subside before making further adjustments. Once the proper setting has been found, no further adjustment is needed. HumidiCalc+ Software takes over and makes any future adjustments caused by varying outdoor temperatures, thus reducing moisture build-up on windows while maintaining the optimal humidity level. NOTE: The furnace blower must be on for the humidifier to operate. 3. Set the Convertible Humidity Control to a high setting, or place the H1008A Automatic Humidity Control in the Test position. 4. Observe the water running out of the drain line to be sure the humidifier is working. 5. Check for leaks. 6. Reset the thermostat and Convertible Humidity Control to a comfortable setting, or the Automatic Humidity Control to the desired frost factor setting, for automatic operation. 5 68-0244 HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER Table 5. Recommended Convertible Humidity Control Settings. At Outside Temperature Recommended Setting At Outside Temperature Recommended Setting -20°F (-29°C) 15 +10°F (-12°C) 30 -10°F (-23°C) 20 +20°F (-7°C) 35 0°F (-18°C) 25 Above 20°F (-7°C) 40 Table 6. Recommended Frost Factor Settings. Humidity Level Recommended Adjustment Insufficient humidity Increase the frost factor dial by one setting. Condensation on windows Decrease the frost factor dial by one setting. OPERATION Every 1 to 3 Months (Depending on Water Quality) The HE225A,B and HE265A,B Humidifiers use the principle that vapor (evaporated water) is created when warm air blows over a water soaked area. As the vapor circulates, the relative humidity rises. Use the following procedure to clean the humidifier: 1. Disconnect the power and turn off the humidifier water supply. 2. Remove the humidifier cover. See Fig. 5. The humidity control monitors the relative humidity and activates the humidifier accordingly. The humidifier has a water supply that disburses water over an antimicrobial humidifier pad. The warm dry air from the furnace passes over the humidifier pad and collects moisture and them circulates it through the house. WATER FEED NOZZLE Humidified air feels warmer and more comfortable so the homeowner may be able to lower the thermostat heating setpoint and save money on heating fuel bills. The end result is that the humidifier gives the homeowner a comfortable environment that is also energy efficient. HUMIDIFIER PAD ASSEMBLY FRAME COVER SIDEWALL MAINTENANCE A regular maintenance program prolongs the life of the humidifier and provides a more comfortable environment. Either hard or soft water can be used in the humidifier. Frequency of cleaning depends on the condition of the water. CAUTION Voltage Hazard. Can cause electrical shock and equipment damage. Disconnect power supply before installing or servicing. HUMIDIFIER HOUSING BY-PASS SIDEWALL WATER FEED TUBE M14672 Fig. 5. Location of humidifier parts. IMPORTANT Never oil any part of the humidifier. 3. Remove the humidifier pad assembly from the humidifier by grasping the tray and pulling it toward you. 4. Pull one side of the humidifier pad assembly frame toward you and remove the tray from the frame. 5. Gently pinch the water nozzle catches inward until the water nozzle can be lifted off the tray. 6. Slide the antimicrobial humidifier pad out of the frame. 7. Carefully scrape any mineral deposits from the tray and frame. Be sure the frame drain hole has nothing blocking it. 68-0244 6 HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER 8. Check the humidifier pad and if excessive mineral deposits are present, replace with a new antimicrobial pad. 9. Disconnect the tube from the drain fitting on the bottom of the humidifier housing. 10. Clean the drain fitting, if necessary. 11. Bend the drain tube to loosen any mineral deposits. 12. Flush the drain tube with pressurized water (a running tap) to clean the tube. 13. Reattach the drain tube to the drain fitting. 14. Slide the humidifier pad back into the frame. IMPORTANT Be sure the humidifier power is off. Beginning of Humidification Season Refer to the Checkout Procedure section to complete the humidifier startup. Vacation When leaving on vacation, turn off the humidifier water supply and the humidity control. When returning from vacation, turn on the humidifier water supply and reset the humidity control to restart the humidifier. IMPORTANT To maintain the antimicrobial properties of the humidifier, use only a Honeywell HC22E or HC26E Antimicrobial Pad. See Table 8 List of Replacement Parts for appropriate pad. Be sure the marked side of the antimicrobial humidifier pad is facing up for proper performance. CHECKOUT PROCEDURE After winter startup or servicing, use the following procedure to check the humidifier operation: 1. Turn on the humidifier power and water supply. 2. Turn the Convertible Humidity Control to the highest setting, or place the H1008A Automatic Humidity Control in the Test position and set the thermostat to 10°F (6°C) above the room temperature. 3. Observe that water is flowing out of the drain hose. 15. Snap the water nozzle back on the tray. 16. Reattach the tray to the frame. 17. Place the humidifier pad assembly in the humidifier housing and press until the assembly is completely seated. Be careful not to pinch or kink the water feed tube. 18. Replace the humidifier cover. 19. Verify the humidifier operation by following the steps in the Checkout Procedure section. NOTE: The furnace blower must be on for the humidifier to operate. 4. Reset the thermostat and Convertible Humidity Control to a comfortable setting, or the H1008A Automatic Humidity Control to the desired frost factor setting, for automatic operation. End of Humidification Season At the end of the heating season, follow steps 1 through 18 from the Every 1 To 3 Months section to clean the humidifier and shut if off. TROUBLESHOOTING Refer to Table 7 for troubleshooting procedures. Table 7. Troubleshooting Procedures. Problem Low humidity High humidity What To Look For What To Do Furnace blower not operating • • • • • Reset circuit breaker or check for blown fuse. Check that the furnace power is on. Check all external wiring connections. Check the humidity control setting. Call a professional heating contractor. Rapid air changes. Drafts (cold air is dry and is an added load to the humidifier). • • • • Keep doors and windows closed. Close fireplace damper when not in use. Keep exhaust fan running time to a minimum. Seal around doors and windows. Condensation on walls. • Turn humidity control and water off until condensation is completely evaporated. Heavy condensation on windows. • Turn humidity control down low enough to eliminate condensation caused by moisture from bathing, mopping, cooking, etc. If moisture persists, more ventilation is needed. 7 68-0244 HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER REPLACEMENT PARTS Refer to Fig. 6 and Table 8 when ordering replacement parts. 10 4 9 8 30 40 20 50 10 11 OF F 5 60 ON 6 12 3 13 7 8 1 2 Fig. 6. Exploded view of humidifier parts. 68-0244 8 8 M14820 HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER Table 8. List Of Replacement Parts For HE220A,B, HE260A,B Humidifiers. Exploded View Number Description HE225 Part Number HE265 Part Number 1 Side wall 32001612-002 32001626-002 2 Bypass side wall 32001613-002 32001627-002 3 Cover Assembly 32001611-003 32001611-004 4 PerfectFlo™ water distribution tray 32001619-001 32001630-001 5 Antimicrobial humidifier pad HC22E1003 HC26E1004 6 Frame 32001621-001 32001632-001 7 Drain fitting 32001615-001 32001615-001 8 Solenoid valve assembly (includes water feed tube and nozzle) 32001639-002 32001639-002 9 Saddle valve assembly 32001616-001 32001616-001 10 Transformer (10 VA) 32001652-001 32001652-001 11 Convertible Humidity Control H8908B1002 H8908B1002 12 Automatic Humidity control with HumidiCalc™+ Software H1008A1008 H1008A1008 13 Base insert assembly, includes no. 8 above 32001625-003 32001625-004 — Hardware Kit for Solenoid Assembly (same as Solenoid valve assembly without the solenoid valve) 32001752-001 32001752-001 — Current Sensing Relay 32001754-001 32001754-001 9 68-0244 HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER 68-0244 10 HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER 11 68-0244 HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER IMPROVE YOUR INDOOR AIR WITH A COMPLETE whole-house air quality system ULTRAVIOLET AIR TREATMENT SYSTEM • ZAP airborne germs. • Kill most germs before they recycle through your home. • Prevent mold spores from growing on your system cooling coils. F300E ELECTRONIC AIR CLEANER • TRAP airborne particles. • Up to 99% efficient at capturing airborne particles. • Effectively REDUCES fungi, bacteria, mold antigen, cat antigen and ragweed pollen antigen that pass through system. ENVIRACAIRE ELITE HUMIDIFIERS • Moisturize parched air. • Help maintain proper humidity to minimize adverse health effects. • Features special antimicrobial agent to prevent surface growth and migration of bacteria, mold, fungus and algae on the humidifier pad. Honeywell offers one of the broadest families of home solutions in the industry - ranging from thermostats, zoning, ventilation, air cleaning, humidification to internet-enabled home control and wireless WebPAD™ devices for web surfing and more!! Check out our offerings on-line at www.honeywell.com/yourhome/ ... only from Honeywell. M14757 Home and Building Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 68-0244 G.H. 11-00 68-0244 Home and Building Control Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled paper containing at least 10% post-consumer 12paper fibers. www.honeywell.com/yourhome/
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Fill forms, Extract, Assemble, Print high-res Create Date : 2000:11:07 14:09:50Z Subject : Product Data Modify Date : 2002:05:31 07:57:23-04:00 Page Count : 12 Creation Date : 2000:11:07 14:09:50Z Producer : Acrobat Distiller 4.0 for Macintosh Keywords : Author : H&BC Mod Date : 2002:05:31 07:57:23-04:00 Metadata Date : 2002:05:31 07:57:23-04:00 Description : Product Data Title : 68-0244 - HE225A,B and HE265A,B|Bypass Flow-Through|Humidifier Creator : H&BCEXIF Metadata provided by EXIF.tools