Honeywell Oven Pw 6000 Users Manual Install Guide
PW-6000 to the manual 6db9a64e-d7b4-43f5-9677-feff26641ceb
2015-01-23
: Honeywell Honeywell-Honeywell-Oven-Pw-6000-Users-Manual-261683 honeywell-honeywell-oven-pw-6000-users-manual-261683 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 36
Download | |
Open PDF In Browser | View PDF |
PW-6000 Intelligent Controller Installation and Configuration Guide Part Number: PW6K1IC July 2007 © 2007 Honeywell. All rights reserved. 800-00005 Copyright© 2007 Honeywell. All rights reserved. All product and brand names are the service marks, trademarks, registered trademarks, or registered service marks of their respective owners. Printed in the United States of America. Honeywell reserves the right to change any information in this document at any time without prior notice. Microsoft and Windows are registered trademarks of Microsoft Corporation. Windows Server is a trademark of Microsoft Corporation. Ordering Information Please contact your local Honeywell representative or visit us on the web at www.honeywellaccess.com for information about ordering. Feedback Honeywell appreciates your comments about this manual. Please visit us on the web at www.honeywellintegrated.com to post your comments. CONTENTS Notices................................................................................................................... 1 Warnings and Cautions .................................................................................. 1 Damage During Shipment .............................................................................. 2 Electro Static Discharge ................................................................................. 2 Disclaimer – Product Liability; Mutual Indemnification .............................. 3 Unpacking Procedure .................................................................................... 3 Shipping Instructions ..................................................................................... 3 Limited Warranty .......................................................................................... 4 Confidentiality ............................................................................................... 4 Product Overview.................................................................................................. 5 PW-6000 and PW-5000.................................................................................. 5 Port Settings.................................................................................................... 5 Other ............................................................................................................... 6 Setting Up the PW-6000 Hardware....................................................................... 8 Setting the Jumpers......................................................................................... 8 Setting the DIP Switches ................................................................................ 9 Technical Specifications............................................................................... 11 Status LEDs ................................................................................................. 12 Supplying Power to the PW-6000 Interface ................................................. 13 Communications Wiring............................................................................... 14 Cabinet Tamper and Power Failure Input Wiring ........................................ 14 Memory and Real Time Clock Backup Battery ........................................... 14 System Configuration via Web Interface ............................................................ 15 Connecting to ACDSM for the First Time ................................................... 15 Login Page .................................................................................................... 15 Home Page.................................................................................................... 16 Network Settings .......................................................................................... 17 Host Port ....................................................................................................... 18 Device Information....................................................................................... 22 User Configuration ....................................................................................... 23 Restore Default Screen ................................................................................. 24 Apply Setting Screen .................................................................................... 25 Log Out......................................................................................................... 25 Appendix A ......................................................................................................... 27 PW-6000 Installation and Configuration Guide, Document 800-00005, Revision A iii LIST OF FIGURES Figure 1: PW-6000 Connections, LEDs, and DIP Switches .............................. 7 Figure 2: PW-6000 Power Terminals ............................................................... 13 Figure 3: PW-6000 Port Wiring ....................................................................... 14 Figure 4: PW-6000 TMP and FLT Terminals .................................................. 14 Figure 5: PW-6000 Web Server Login Screen ................................................. 15 Figure 6: PW-6000 Web Server Home Page .................................................... 16 Figure 7: PW-6000 Web Server Network Settings Screen .............................. 17 Figure 8: PW-6000 Host Port Configuration Screen with IP Server Connection ...................................................................................................... 18 Figure 9: PW-6000 Host Port Configuration Screen with IP Client Connection ..................................................................................................... 20 Figure 10: PW-6000 Host Port Configuration with Serial RS-232 Connection 21 Figure 11: PW-6000 Web Server Device HW Info Screen ................................ 22 Figure 12: PW-6000 Web Server User Info Screen ........................................... 23 Figure 13: PW-6000 Web Server Restore Default Screen ................................. 24 Figure 14: PW-6000 Web Server Apply Setting Screen .................................... 25 PW-6000 Installation and Configuration Guide, Document 800-00005, Revision A v LIST OF TABLES Table 1 Table 2 Table 3 Table 4 Table 5 PW-6000 Jumper Settings .................................................................. 8 PW-6000 DIP Switch Settings ............................................................ 9 PW-6000 Technical Specifications ................................................... 11 PW-6000 Status LED Combinations During Initialization .............. 12 PW-6000 Status LED Combinations During Run Time ................... 13 PW-6000 Installation and Configuration Guide, Document 800-00005, Revision A vii viii www.honeywell.com PW-6000 Installation 1 Notices 1.1 Warnings and Cautions Before Installation Warning: Before installation, TURN OFF the external circuit breaker which supplies power to the system. Before connecting the device to the power supply, verify that the output voltage is within specifications of the power supply (see 'Technical Specifications' on page 11). Do not apply power to the system until after the installation has been completed. Personal injury or death can occur, and the equipment can be damaged beyond repair, if this precaution is not observed. Fire Safety and Liability Notice Warning: Never connect card readers to any critical entry, exit door, barrier, elevator or gate without providing an alternative exit in accordance with all the fire and life safety codes pertinent to the installation. These fire and safety codes vary from city to city and you must get approval from local fire officials whenever using an electronic product to control a door or other barrier. Use of egress buttons, for example, may be illegal in some cities. In most applications, single action exit without prior knowledge of what to do is a life safety requirement. Always make certain that any required approvals are obtained in writing. DO NOT ACCEPT VERBAL APPROVALS SINCE THEY ARE NOT VALID. Honeywell Integrated Security never recommends using the PW-6000 or related products for use as a primary warning or monitoring system. Primary warning or monitoring systems should always meet the local fire and safety code requirements. The installer must also test the system on a regular basis by instructing the end user in appropriate daily testing procedures. Failure to test a system regularly could make the installer liable for damages to the end user if a problem occurs. PW-6000 Installation Guide, Document 800-00005, Revision A 1 PW-6000 Installation Notices Earth Grounding Warning: EARTH ground all enclosures for proper installation. Use Suppressors Warning: Use suppressors on all door strikes. Use S-4 suppressors for installation. Honeywell Integrated Security, Inc. recommends only DC strikes. 1.2 Damage During Shipment Caution: IF ANY DAMAGE TO THE SHIPMENT IS NOTICED, A CLAIM MUST BE FILED WITH THE COMMERCIAL CARRIER RESPONSIBLE FOR THE DAMAGE. 1.3 Electro Static Discharge Caution: Electro-static discharge (ESD) can damage CMOS integrated circuits and modules. To prevent damage always follow these procedures: • Use static shield packaging and containers to transport all electronic components, including completed reader assemblies. • Handle all ESD sensitive components at an approved static-controlled workstation. These workstations consist of a desk mat, floor mat and an ESD wrist strap. Workstations are available from various vendors. Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the installation and user guides, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This document and the data in it shall not be duplicated, used or disclosed to others for procurement or manufacturing, except as authorized by and with the written permission of Honeywell Integrated Security, Inc.The information contained in this document or in the product itself is the exclusive property and trade secrets of Honeywell Integrated Security, Inc. Copyright laws of the United States protect all information in this document or in the software product itself. Note: Note: Any use of this product is subject to the terms and acceptance of the Honeywell Integrated Security, Inc. Software Agreement. Please request a copy from Honeywell Integrated Security, Inc. (http://www.honeywellintegrated.com/index.html), and review the agreement carefully. 2 www.honeywell.com PW-6000 Installation Notices 1.4 Disclaimer – Product Liability; Mutual Indemnification If a Customer receives a claim that a Product or any component thereof has caused personal injury or damage to the property of others, Customer shall immediately notify Honeywell Integrated Security in writing of all such claims. Honeywell Integrated Security shall defend or settle such claims and shall indemnify and hold Customer harmless for any costs or damages including reasonable attorneys’ fees which Customer may be required to pay as a result of the defective Product or the negligence of Honeywell Integrated Security, its agents, or its employees. Customer shall hold harmless and indemnify Honeywell Integrated Security from and against all claims, demands, losses and liability arising out of damage to property or injury to persons occasioned by or in connection with the acts or omissions of Customer and its agents and employees, and from and against all claims, demands, losses and liability for costs of fees, including reasonable attorneys’ fees, in connection therewith. 1.5 Unpacking Procedure Caution: If any damage to the shipment is noticed before unpacking, a claim must be filed with the commercial carrier. All containers should be opened and unpacked carefully in order to prevent damage to the contents. Follow these steps to unpack equipment in preparation for installation: 1. Open the container and remove the unit(s) and all packing material. Retain the container and all the packing materials. They may be used again for reshipment of the equipment, if needed. 2. Inspect the contents to see if anything is missing. If you notice any missing items, contact the order entry department at 1-800-323-4576 Option-1. 3. Visually check the contents. If you see any damage, do the following: a. If shipping has caused damage to the unit, a claim must be filed with the commercial carrier. b. If any other defect is apparent, call for a return authorization. 1.6 Shipping Instructions To ship equipment back to Honeywell Integrated Security, contact the customer service department at 1-800-323-4576 before returning the equipment. When you call, please have available: • A description of the problem or the reason you are returning the equipment. • Your original purchase order number, invoice number and if the unit is still under warranty. • A new purchase order number if the unit is not under warranty From the customer service department, obtain the Return Authorization Number (RMA). PW-6000 Installation Guide, Document 800-00005, Revision A 3 PW-6000 Installation Notices Show the RMA number on all packages shipped. Packages, which are not marked with an RMA number will be refused at the factory and returned to you COD. Carefully pack the equipment for shipment. Use the original packing material whenever possible 1.7 Limited Warranty All Products sold or licensed by Honeywell Integrated Security include a warranty registration card which must be completed and returned to Honeywell Integrated Security by or on behalf of the end user for Honeywell Integrated Security to provide warranty service, repair, credit or exchange. All warranty work shall be handled through Customer which shall notify Honeywell Integrated Security and apply for a Return Merchandise Authorization (RMA) number prior to returning any Product for service, repair, credit or exchange. Honeywell Integrated Security warrants that its Products shall be free from defects in materials and workmanship for a period of two years from the date of shipment of the Product to Customer. The warranty on Terminals, Printers, Communications Products and Upgrade kits is 90 days from the date of shipment. Satisfaction of this warranty shall be limited to repair or replacement of Products which are defective or defective under normal use. Honeywell Integrated Security’s warranty shall not extend to any Product which, upon examination, is determined to be defective as a result of misuse, improper storage, incorrect installation, operation or maintenance, alteration, modification, accident or unusual deterioration of the Product due to physical environments in excess of the limits set forth in Product manuals. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THIS PROVISION. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. NO REPRESENTATION OR WARRANTY OF THE DISTRIBUTOR SHALL EXTEND THE LIABILITY OR RESPONSIBILITY OF THE MANUFACTURER BEYOND THE TERMS OF THIS PROVISION. IN NO EVENT SHALL HONEYWELL INTEGRATED SECURITY BE LIABLE FOR ANY RE-PROCUREMENT COSTS, LOSS OF PROFITS, LOSS OF USE, INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES TO ANY PERSON RESULTING FROM THE USE OF HONEYWELL INTEGRATED SECURITY’S PRODUCTS. 1.8 Confidentiality All software, drawings, diagrams, specifications, catalogs, literature, manuals and other materials furnished by Honeywell Integrated Security relating to the design, use and service of the Products shall remain confidential and shall constitute the proprietary rights of Honeywell Integrated Security and Customer agrees to treat such information as confidential. Customer shall acquire no rights in the design of the Products or the related materials except to use such information solely for the purpose of and only during the time it sells the Products. 4 www.honeywell.com PW-6000 Installation Product Overview Customer shall not copy the design of any of the Products or use or cause to be used any Product design or related materials for its own benefit or for the benefit of any other party. The covenants contained in this section shall remain effective throughout the term of this Agreement and thereafter unless specifically waived by Honeywell Integrated Security in writing. 2 Product Overview The Intelligent Controller is the heart of the PW-6000 and provides the real time processing for the connected I/O interfaces. The PW-6000 is designed to operate without the need for a PC. It can be connected to a Pro-Watch host computer using direct serial communication, dial-up modem, or TCP/IP network connection. The PW-6000 holds the database for the subsystem configuration and card holders, and the event log buffer, which is in battery-backed memory. Note: Please refer to the Pro-Watch Software Suite Guide for details on using the Pro-Watch interface. 2.1 PW-6000 and PW-5000 • The PW-6000 controller configuration and operation is similar to the PW-5000 controller; both use the Pro-Watch at the front end. • You can use the PW-5000 controller interface to configure the PW-6000 hardware settings. 2.2 Port Settings • Port 0 provides the host-embedded Ethernet interface. • Port 1 is for RS-232 or RS-485 2-wire serial interface connections. An optional Lantronix CoBox-Micro interface daughter board (10Base-T/100Base-TX) is also supported on Port 1. • Ports 2 and 3 are for RS-485 2-wire downstream support for connecting 32 I/O devices. Note that the I/O communications must be mapped differently in Pro-Watch, according to the following table: PW-6000 Port Pro-Watch Port 2 4 3 6 See Table 1 'PW-6000 Jumper Settings' on page 8 for more information on how to configure the port settings. PW-6000 Installation Guide, Document 800-00005, Revision A 5 PW-6000 Installation Product Overview 2.3 Other • An on-board real time clock maintains the date and time, taking into account leap year and accounting for global time zones and daylight savings time changes. • The database for the system configuration and card holders are stored in FLASH memory. • The event log buffer is stored in battery-backed memory. • Configuration data and event/status reports are communicated to the host via on-board 10-BaseT/100Base-TX Ethernet port or Port 1. • Transactions are stored in 1 MB of battery-backed SRAM. The maximum number of transactions stored while the host is offline is 50,000. • Cards are stored in Flash memory and read into DRAM when the board is powered up. The amount of storage available for cards and biometric records is 15 MB. The maximum number of cards depends on the card record database configuration, but the number is approximately 300,000. This maximum is dependent on how the card is configured with more space per card used with longer card number, more clearance codes, and so on. 6 www.honeywell.com PW-6000 Installation Product Overview Figure 1: PW-6000 Connections, LEDs, and DIP Switches PW-6000 Installation Guide, Document 800-00005, Revision A 7 PW-6000 Installation Setting Up the PW-6000 Hardware 3 Setting Up the PW-6000 Hardware The PW-6000 processor is configured with 12 jumpers and a set of 4 DIP switches. These jumpers/switches set up the port interface, end of line termination, and operating mode configuration. Refer to the tables below to set the jumpers as required. 3.1 Setting the Jumpers Table 1 PW-6000 Jumper Settings Jumpers Set At Description J1 N/A 10Base-T/100Base-TX Ethernet Connection (Port 0) J2 N/A Factory Use Only J3 OFF Port 2 RS-485 EOL Terminator is OFF ON Port 2 RS-485 EOL Terminator is ON OFF Port 3 RS-485 EOL Terminator is OFF ON Port 3 RS-485 EOL Terminator is ON OFF Port 1 RS-485 EOL Terminator is OFF ON Port 1 RS-485 EOL Terminator is ON J6 N/A Factory Use Only J7 N/A COBOX-MICRO Ethernet Module Connection (Port 1) J8, J9, J10 232 Port 1 is RS-232 485 Port 1 is RS-485 J11 N/A Factory Use Only J12 N/A Factory Use Only J4 J5 8 www.honeywell.com PW-6000 Installation Setting Up the PW-6000 Hardware 3.2 Setting the DIP Switches Dual In-line Package (DIP) switches are read when the system powers up, except where noted otherwise. The following table shows the setting options. Table 2 PW-6000 DIP Switch Settings S1 S2 S3 S4 Selection OFF OFF OFF OFF Normal Operating Mode. ON OFF OFF OFF When DIP switch 1 is ON, Port 0 communicates with the web browser. Port 1 is used for RS-232/485 communications. After the panel initialization, enable the default user name (admin) and password (password). The user name and password are read dynamically; you do not need to reboot the panel. OFF ON OFF OFF Use the factory default communication parameters. ON ON OFF OFF Unless the network administrator reserves an IP address for the panel (based on the controller board’s Media Access Control (MAC) address), the PW-6000 uses Dynamic Host Configuration Protocol (DHCP) to obtain an IP address from the network DHCP server. When power is applied with the switches in this position, there is a ten second window (when LEDs 1and 2 flash alternately with LEDs 3 and 4), during which memory is cleared if switch 1 or switch 2 is changed to OFF. When switch 1 or 2 is changed to OFF, only LED 2 flashes and memory begins to be cleared. This period of clearing lasts several minutes. When the memory has been cleared, the LED pattern changes to the flashing of LEDs 1 and 4. The panel then reboots by itself. All data in memory is erased except the serial number, MAC address, hardware revision, and OEM code. PW-6000 Installation Guide, Document 800-00005, Revision A 9 PW-6000 Installation Setting Up the PW-6000 Hardware The PW-6000 DIP switches need to be set twice: 1. Configure the S4-S3-S2-S1 DIP switches to off-off-on-off to set the default TCP/IP address to 192.168.0.251. 2. Apply power to the panel to set the IP address. 3. Change the S4-S3-S2-S1 combination to off-off-off-on.(DIP switch 1 is “read on the fly”). This sets the login to the default user ID (“admin”) and password (“password”) for Ethernet communications. 4. Create users. See 'User Configuration' on page 23 for instructions. 5. Set the S4-S3-S2-S1 combination to off-off-off-off. 6. Configure the host port for TCP/IP and/or Serial communications. See 'Host Port' on page 18 for instructions. This will enable both TCP/IP and serial hardware networking when you log in again. 10 www.honeywell.com PW-6000 Installation Setting Up the PW-6000 Hardware 3.3 Technical Specifications Table 3 PW-6000 Technical Specifications Category Description WARNING: PW-6000 is manufactured for use in low-voltage, Class 2 circuits only. Primary Power 12Vdc ± 10%, 300mA maximum. 12Vdc @ 240mA (325mA with CoBox-Micro) nominal. Memory and Clock Backup 3Volts Lithium, type BR2325, BR2330, CR2330. Ports Port 0 10Base-T/100Base-TX Ethernet. Port 1 RS-232 or 2-wire RS-485: 9,600 to 115,200 bps, async. An optional Lantronix CoBox-Micro interface daughter board is supported (10Base-T/100Base-TX). Port 2 & 3 2-wire RS-485: 2,400 to 38,400 bps, async. Inputs 2 non-supervised, dedicated for cabinet tamper and power fault monitoring. Cable requirements Power: 1 twisted pair, 18 AWG. RS-485: 24AWG, 4,000ft (1,200m) maximum, twisted pair with shield. 120 ohm. RS-232: 24AWG, 25ft (7.6m) maximum. Ethernet: Cat 5. Alarm input: 1 twisted pair, 30 ohms maximum. Temperature: 0 to 50°C, operating Environmental -55 to +85°C, storage Mechanical Humidity: 0 to 95% RHNC Dimensions: 5.5 in. (137.7mm) W x 9 in. (228.6.4mm) L x .75 in. (19.05mm) H Lantronix NIC support Weight: 7.1 oz. (201 gm) nominal Standoff size Diameter 0.125 inch x 0.4375 inch long Richco Plastics part number LMSP-7-01, 3 pieces (not supplied) Specifications subject to change without notice. PW-6000 Installation Guide, Document 800-00005, Revision A 11 PW-6000 Installation Setting Up the PW-6000 Hardware Caution: Locate the power source as close to this board as possible. Connect power with minimum of 18AWG wires. POLARITY for 12 VDC power is important. Make sure the +12 VDC is connected to the terminal labeled +12V and the return is connected to the terminal labeled GND. Note: 3.4 Status LEDs The PW-6000 uses six on-board LEDs to provide status information during its initialization sequence and normal run-time operation. Initialization Table 4 PW-6000 Status LED Combinations During Initialization 12 LED 1 LED 2 LED 3 LED 4 LED 5 LED 6 Description ON OFF OFF OFF OFF OFF Basic processor initialization ON ON OFF OFF OFF OFF Internal SRAM test ON OFF ON OFF OFF OFF External SDRAM, First Chip ON ON ON OFF OFF OFF External FLASH Test ON OFF OFF ON OFF OFF External SDRAM, Second ON ON OFF ON OFF OFF External SRAM Test ON OFF ON ON OFF OFF External EEPROM Test ON ON ON ON OFF OFF External RTC Test ON OFF OFF OFF ON OFF Backup Battery and Reset ON ON OFF OFF ON OFF UART Test ON OFF ON OFF ON OFF Ethernet Interface, MII OFF ON X X X X Final processor Initialization www.honeywell.com PW-6000 Installation Setting Up the PW-6000 Hardware Run TimeSupplying Power to the PW-6000 Interface Table 5 PW-6000 Status LED Combinations During Run Time LED Description 1 Off-Line / On-Line and Battery Status Off-Line = 20% On, ON-Line = 80% On Double Flash means the Battery is Low 2 Primary Host Communication Activity (Ethernet or Port 1) 3 Port 2 Communication Activity 4 Port 3 Communication Activity 5 ON = Writing to Flash Memory. Do NOT cut off power when this LED is ON. 6 TBD SPD On-Board Ethernet Speed. OFF = 10MBS. ON = 100MBS. ACT OFF = No On-Board Ethernet Activity. ON = On-Board Ethernet Activity (YELLOW LED). LNK OFF = ON Link. ON = Good Link (GREEN LED). 3.5 Supplying Power to the PW-6000 Interface The processor accepts 12Vdc for power. Locate power source as close to the unit as possible and connect it with minimum of 18AWG wires. Caution: Observe Figure 2: POLARITY on 12 VDC. PW-6000 Power Terminals TB1 TR+ TR- PORT 3 GND +12V GND + 12Vdc ±10% - PW-6000 Installation Guide, Document 800-00005, Revision A 13 PW-6000 Installation Setting Up the PW-6000 Hardware 3.6 Communications Wiring The PW-6000 processor communicates to the host via on-board Ethernet 10Base-T/100Base-TX port or on port 1. Port 1 may be configured as RS-232, two-wire RS-485 or optional Lantronix Ethernet 10Base-T/ 100Base-TX CoBox-Micro interface. The RS-232 interface is for direct one to one connection to a host computer, or a modem. Ports 2 and 3 use the two-wire RS-485 interface only. The interface allows multi-drop communication on a single bus of up to 4,000 feet (1,200 meters). Use shielded twisted pair (minimum 24 AWG) with 120-ohm impedance. Install termination jumpers only at the end-of-line unit. Figure 3: PW-6000 Port Wiring TB3 TB2 TB3 TB1 TXD/TR+ RXD/TR- TXD/TR+ RXD/TR- TR+ TR- TR+ TR- RTS CTS GND RTS CTS GND GND GND +12V GND PORT 1 CONFIGURED as RS-232 PORT 1 CONFIGURED as 2-WIRE RS-485 PORT 2 2-WIRE RS-485 PORT 3 2-WIRE RS-485 3.7 Cabinet Tamper and Power Failure Input Wiring Figure 4: PW-6000 TMP and FLT Terminals Inputs TMP and FLT are used for monitoring cabinet tamper and power failure with normally closed contacts. These two inputs are for contact closure monitoring only; do not use end-of-line (EOL) resistor(s). If these inputs are not used, install a short piece of wire at the input to indicate a safe condition. 3.8 Memory and Real Time Clock Backup Battery The event log buffer and the real time clock are backed up by a 3V lithium battery. This BR2325, BR2330, or CR2330 battery should be replaced annually. 14 www.honeywell.com PW-6000 Installation System Configuration via Web Interface 4 System Configuration via Web Interface The PW-6000 comes with Access Control Device Server Manager (ACDSM). The ACDSM is a built-in web server, through which you can configure network and other system settings. Notes: • If you are using Internet Explorer Enhanced Security Configuration, you cannot access the ACDSM web server. All pages will display “Bad Request!” You must uninstall the Enhanced Security option before you can access the ACDSM. • The default factory-set TCP/IP address for the built-in system configuration web server is 192.168.0.251 4.1 Connecting to ACDSM for the First Time 1. Use the factory default controller IP address 192.168.0.251. 2. Set the DIP switches to S4=OFF, S3=OFF, S2=ON, S1=OFF. S1 must be set to OFF for the factory default. After the panel powers up, change S1 to ON to enable the use of the default user name and password. Note: 3. Connect the computer to host the web server via Ethernet Port 0. Connection should be via crossover Ethernet cable or by the regular Ethernet cables connected via the hub. 4. Set the host computer to the static IP address 192.168.0.250 to be able to connect to the factory-default PW-6000 controller at address 192.168.0.251. 5. Power up the PW-6000 controller. 4.2 Login Page 1. Click the “Click Here to Login” link to display the User Name and Password fields. Figure 5: PW-6000 Web Server Login Screen 2. Enter your User Name and Password. Note: Default User ID is admin and the default Password is password. PW-6000 Installation Guide, Document 800-00005, Revision A 15 PW-6000 Installation System Configuration via Web Interface 4.3 Home Page The first screen after the login is the home page which displays all the available configuration links on the left navigation bar: Figure 6: 16 www.honeywell.com PW-6000 Web Server Home Page PW-6000 Installation System Configuration via Web Interface 4.4 Network Settings Click the Network link on the navigation bar to display the Network Settings screen where you can select the appropriate option button for dynamic or static IP address configuration: Figure 7: PW-6000 Web Server Network Settings Screen Notes: • The Host Name of This Device field contains the Media Access Control (MAC) address of the PW-6000 controller board. • The IP address configuration is same as using the Lantronix Ethernet board on a PW-5000. The users can select the Dynamic IP option button and reserve an IP address for the MAC address, or they can select the other option button and assign a Static IP address as well. Dynamic IP Configuration Method 1. Click the Dynamic IP option button to select the Dynamic Host Configuration Protocol (DHCP) method to obtain IP address automatically. 2. Click OK. The Pro-Watch communicates with the PW-6000 panel using an IP address. If you must use the Dynamic IP option because of your network policies or configuration, you must reserve an IP address at the DHCP server for the MAC (Media Access Control) address in the PW-6000 panel. The MAC address is a unique identifier attached to network adapters. Each time the PW-6000 panel requests an IP address, the DHCP server will assign the address that was reserved for it. Note: PW-6000 Installation Guide, Document 800-00005, Revision A 17 PW-6000 Installation System Configuration via Web Interface Static IP Configuration Method 1. Click the Static IP option button to assign a static IP address, and enter the following information in the appropriate fields: • IP Address • Subnet Mask • Default Gateway 2. Click OK. 4.5 Host Port Click the Host Port link on the navigation bar to display the Host Connection Configuration screen where you can select the appropriate settings for the Primary Host Port and Alternate Host Port: Note: Some of the fields change dynamically depending on the Connection Type selected. IP Server Connection Type Figure 8: 18 www.honeywell.com PW-6000 Host Port Configuration Screen with IP Server Connection PW-6000 Installation System Configuration via Web Interface 1. From PW6000 Communication Address drop-down list, select one of the eight (0 to 7) available communication addresses for the PW-6000 board. Note: In the previous panels, this selection was made manually by setting the DIP switches. 2. For the Primary Host Port, make the following selections: a. Connection Type. Select IP Server (the standard connection type), so that the Pro-Watch Host will poll the PW-6000 panel. The panel does not currently support the IP Client option, which would cause the PW-6000 panel to poll the Pro-Watch Host and the Host to reply to the panel. a. Data Security. Select one of the following: – None – Password/AES from the drop-down list. If you select Password/AES, communications between the Pro-Watch Host and the PW-6000 panel are encrypted. Note that encryption must be enabled in Pro-Watch for the appropriate Pro-Watch channel. See Chapter 7, “Hardware Configuration,” in the Pro-Watch Guide for channel encryption instructions. b. Port Number. Enter the port number through which the host computer can communicate with the PW-6000 board. c. Select either Allow All or the Authorized IP Address Required option button. – Allow All, as the label suggests, allows all IP addresses to communicate with the PW-6000. Select this option for web page browser access. – If you select the Authorized IP Address Required option, also enter in the Authorized IP Addresses fields all the IP addresses that would be allowed to communicate with the PW-6000. Use this option only for Host communication. 3. For the Alternate Host Port, make the following selections: a. Connection Type. Select one of the following values from the drop-down list: IP Server, Serial-RS232, Serial-RS485, Serial-Modem, Serial-CoBox. Note that the IPClient option is listed, but it is not supported by the panel and should not be selected. b. Data Security. Select one of the following values from the drop-down list: None, Password/no AES, Password/AES. c. Select a Baud Rate from the drop-down list. d. Select a Flow Control from the drop-down list. 4. Click OK. PW-6000 Installation Guide, Document 800-00005, Revision A 19 PW-6000 Installation System Configuration via Web Interface IP Client Connection Type Figure 9: Note: 20 PW-6000 Host Port Configuration Screen with IP Client Connection The PW-6000 panel does not currently support an IP Client connection. www.honeywell.com PW-6000 Installation System Configuration via Web Interface Serial-RS232, Serial-RS485, Serial-Modem, or Serial-CoBox Connection Types Figure 10: PW-6000 Host Port Configuration with Serial RS-232 Connection 1. From the PW6000 Communication Address drop-down list, select one of the eight (0 to 7) available communication addresses for the PW-6000 board. Note: In the previous panels, this selection was made through setting the virtual DIP switches. 2. For the Primary Host Port, make the following selections: a. Connection Type. From the drop-down list, select Serial-RS232. Select one of the following as appropriate: Serial-RS232, Serial-RS495, Serial-Modem, Serial-CoBox. b. Data Security. Select one of the following values from the drop-down list: None, Password/no AES, Password/AES. c. Select a Baud Rate from the drop-down list. d. Select a Flow Control from the drop-down list. PW-6000 Installation Guide, Document 800-00005, Revision A 21 PW-6000 Installation System Configuration via Web Interface 3. For the Alternate Host Port, make the following selections: a. Connection Type. If you choose to configure an alternate host port, and if you have selected Serial-RS232 for the primary host port, select IP Server from the drop-down list for the alternate host port. b. Data Security. Select one of the following values from the drop-down list: None, Password/no AES, Password/AES. c. Select a Baud Rate from the drop-down list. d. Select a Flow Control from the drop-down list. 4. Click OK. 4.6 Device Information Click the Device Info link on the navigation bar to display the read-only Access Control Device Hardware Information screen: Figure 11: PW-6000 Web Server Device HW Info Screen 22 www.honeywell.com PW-6000 Installation System Configuration via Web Interface 4.7 User Configuration Click the Users link on the navigation bar to display the User screen where you can add, edit, and delete user records: Figure 12: PW-6000 Web Server User Info Screen Adding a User Follow these steps: 1. Click New Account to display the new user account screen. 2. Enter the following: • User name – a unique character string that identifies the user. • Level – level of privileges the user will have. Level 1 grants the user read/write privileges to all panel features; level 2 grants the user read-only privileges to the Notes, Network, Host Port, and Device Info features; level 3 grants the user read-only privileges to just the Notes and Device Info features. PW-6000 Installation Guide, Document 800-00005, Revision A 23 PW-6000 Installation System Configuration via Web Interface 3. Specify the maximum period of time a session will remain open without user activity. If the period expires without user activity, the user is logged out. After specifying the time period, click Save Session Timer to save the setting. 4. Configure the auto-save timer. This feature, if enabled, automatically saves the hardware configuration in non-volatile Random Access Memory (RAM) at the specified time interval. If you select Enable Auto-Save, then select a time interval from the drop-down list, and click Save Auto-Save Timer to save the setting. Editing a User To edit a user record, click to select the user from the Username column and then click Edit. Use the information provided in the previous section, “Adding a User,” to edit the record. Deleting a User To delete a user record, click to select the user from the Username column and then click Delete. 4.8 Restore Default Screen Click the Restore Default link on the navigation bar to restore the default configuration values for the PW-6000: Figure 13: PW-6000 Web Server Restore Default Screen 1. Click Restore Default to reload the default factory settings for all the configuration variables. 2. Click Restore Current to reload the current operational settings for all the configuration variables. 24 www.honeywell.com PW-6000 Installation System Configuration via Web Interface 4.9 Apply Setting Screen Click the Apply Setting link on the navigation bar to apply the selected configuration values: Figure 14: PW-6000 Web Server Apply Setting Screen Click Apply, Reboot to apply all the configured values and reboot the PW-6000. 4.10 Log Out Click the Log Out link on the navigation bar to log out of the web server. PW-6000 Installation Guide, Document 800-00005, Revision A 25 PW-6000 Installation System Configuration via Web Interface 26 www.honeywell.com Appendix A PW-6000 Web Server and Pro-Watch Channels The PW-6000 web server’s host port configuration requires corresponding changes in the way the Pro-Watch’s channels are configured. The PW-6000 web server host ports and the Pro-Watch channel ports must have the correct values to communicate with each other. Follow these steps: 1. Set the PW-6000 hardware configuration: a. On the controller board, set the jumpers J8, J9, J10 on Port1 to RS-485. b. On Port1, connect the pins as follows: – pin1 = TR+ – pin2 = TR– pin5 = GND to RS-485 terminals of the Intelligent “Auto” Converter PW5K1CVT1 (i.e., PW-5000 RS-232/RS-485 converter) c. Connect the RS-232 terminal of the PW5K1CVT1 converter to the serial port of your Pro-Watch application server. 2. Set the host port configuration of the PW-6000 web server: a. Login to the Access Control Device Server Configuration Manager. b. Set the Primary Host fields as follows: – Connection Type = IP Server – Port Number = 3001 – Data Security = Allow All c. Set the Alternate Host Port fields as follows: – Connection Type = Serial-RS-485 – Baud Rate= 38400 – Data Security = None – Flow Control = RTS Toggle PW-6000 Installation and Configuration Guide, Document 800-00005, Revision A 27 d. Click OK. e. From the Setting menu, select Apply, Reboot. The system will display the “Board is Restarting” message. 3. Set the port configuration for the Pro-Watch channel: a. In Pro-Watch, click Hardware Configuration on the left navigation bar. b. Right click on your Site to launch the mini pop-up menu. c. Select New > Channel to display the Create a Channel dialog box. d. Click the Channel Type drop-down list and select PW-5000. The icon of the newly created PW-5000 channel will display in the right pane. e. Right click on the icon of your PW-5000 channel and select Properties to display the Edit Channel Screen dialog box. This screen displays configuration fields for the Primary Port (related to the Primary Host on the web server) as well as the Secondary Port (related to the Alternate Host Port on the web server). f. For both Primary and Secondary ports, select the appropriate values for the following configuration fields: – If the Port Type is Hard Wired (related to Serial-RS485 web server host port), then fill in the following settings: • ComPort • Baud – If the Port Type is TCP/IP (related to IP Server web server host port), then fill in the following settings: • IP Address • Port Number If you are using a modem, and the modem uses a procedure that calls Pro-Watch, then the modem must be the primary port. Note: 28 www.honeywell.com For more information: www.honeywellintegrated.com Honeywell Access Systems 135 W. Forest Hill Avenue Oak Creek, WI 53154 414-766-1700 414-766-1798 Fax European Office Boblingerstrasse 17 D-71101 Schonaich Germany 49-7031-637-782 49-7031-637-769 Fax www.honeywell.com Specifications subject to change without notice. © Honeywell. All rights reserved. 800-00005, Revision A
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : FrameMaker 7.1 Modify Date : 2007:07:26 13:47:38-05:00 Create Date : 2007:07:23 18:39:19Z Metadata Date : 2007:07:26 13:47:38-05:00 Format : application/pdf Title : PW-6000 Install Guide.book Creator : richardg Document ID : uuid:aafcb6a6-be02-4adc-92ec-b8621aa33e47 Instance ID : uuid:fd4ee9c6-0085-4d25-8192-4c2dc69e2fa3 Has XFA : No Page Count : 36 Author : richardgEXIF Metadata provided by EXIF.tools