Honeywell Smoke Alarm C Users Manual 63 2590—05 Series 2000 Electronic Temperature Sensors
C to the manual 97542ac0-3a1a-476c-8dea-e5a8094fddb8
2015-01-23
: Honeywell Honeywell-Honeywell-Smoke-Alarm-C-Users-Manual-261828 honeywell-honeywell-smoke-alarm-c-users-manual-261828 honeywell pdf
Open the PDF directly: View PDF
.
Page Count: 12
| Download | |
| Open PDF In Browser | View PDF |
Series 2000 Electronic Temperature Sensors PRODUCT DATA C7021B/C C7023B/C C7031B C7041B/C C7021R C7023R C7041R C7021D C7023D C7031D C7041D C7021J C7023J C7031J C7041J C7021P C7023P C7041P C7021F C7023F C7031G C7041F C7021N C7023N C7041N C7021K C7023K C7041K APPLICATION • C7021J/R, C7023J/R, C7031J, C7041J/R sense average duct air temperature. The Series 2000 C7021, C7023, C7031 and C7041 Electronic Temperature Sensors are designed for use with electronic controllers in domestic or commercial heating and cooling systems. • C7021B/C, C7023B/C, C7031B, C7041B/C sense duct air temperature. FEATURES • C7021D, C7023D, C7031D, C7041D for immersion mounting sense water temperature. • C7021K, C7023K, C7041K with strap-on mounting senses water temperature. • C7021N, C7023N, C7041N probe senses water or air temperature. • C7021P, C7023P, C7041P senses air temperature. • Solid state components not affected by dust or dirt. • C7021F, C7023F, C7031G, C7041F sense outdoor air temperature and are weatherproof for outdoor use (knockouts allow for 1/2 in. conduit connection). Contents Application......................................................................... 1 Features ............................................................................ 1 Specifications .................................................................... 2 Installation ......................................................................... 8 Wiring ................................................................................11 Operation and Checkout ...................................................11 63-2590-05 SERIES 2000 ELECTRONIC TEMPERATURE SENSORS SPECIFICATIONS See Table 1 for additional specifications. Compatability: Use Series 2000 C7031, C7041 Temperature Sensors with Excel 10, 15, 80, 100, and 500 controllers. Series 2000 C7031B,D,G,J sensors are compatible with various Honeywell controllers. The C7031G2014 is compatible with the T7350 Commercial Thermostat. Series 2000 C7021 temperature sensors are compatible with TB7600, TB7300 and TB7200 communicating thermostats. Series 2000 C7023 temperature sensors are compatible with WEBs-AX I/O modules. Dimensions: See Fig. 1 through Fig. 11. Sensor Accuracy: ±0.36°F at 77°F (±0.2°C at 25°C) for 20K ohm NTC sensors and 10K ohm NTC Type II and Type III sensors. Accessories: 32006523-001 20K Probe: to allow replacement of old style C7031D1062-1 with non-threaded well. 50001774-001 Stainless Steel 304 Well Assembly: 1/2 in. external and internal NPT threading. Use with C7021D/ C7023D/C7031D/C7041D. 50001775-001 Well Adapter: Used with C7021D/C70231D/ C7031D/C7041D to allow threading sensor into previouslyinstalled Series 1000 32005960-001 Well. Table 1. Sensor Selection and Application Guide Model Element Element Control Application Insertion Length Operating Range C7021B C7021C Duct discharge air Duct discharge air C7021D Hot or chilled water b 5 in. (127 mm) C7021F Outdoor air C7021J Duct discharge air (averaging sensor with 4 elements) C7021K Hot water (strap-on mounting)f C7021N Water / Air (bullet probe) C7021P Space air temperature (button probe) C7021R Duct discharge air (rigid copper averaging sensor) 12 ft (3.7m) or 24 ft (7.3m) C7023B Duct discharge air 6 in. (152) or 12 in. (305 mm) -40° to 250°F C7023C Duct discharge air 18 in. (457 mm) (-40° to 121°C) C7023D Hot or chilled water b 5 in. (127 mm) Element Max Ambient Temperature Sensor Resistance in Ohms Sensitivitya 6 in. (152) or 12 18 in. (457 mm) — -40° to 158°F (-40° to 70°C) 12 ft (3.7m) 250°F (121°C) 10K Ohms NTC @ 77° F Type II — -40° to 250°F (-40° to 121°C) 250°F (121°C) 10K Ohms NTC @ 77° F Type III — ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 3. http://customer.honeywell.com or http://customer.honeywell.ca International Sales and Service Offices in all principal cities of the world. Manufacturing in Belgium, Canada, China, Czech Republic, Germany, Hungary, Italy, Mexico, Netherlands, United Kingdom, and United States. 63-2590—05 2 SERIES 2000 ELECTRONIC TEMPERATURE SENSORS Table 1. Sensor Selection and Application Guide Model Element Element Control Application Insertion Length Operating Range C7023F Outdoor air C7023J Duct discharge air (averaging sensor with 4 elements) C7023K Element Max Ambient Temperature Sensor Resistance in Ohms Sensitivitya -40° to 158°F (-40° to 70°C) 12 ft (3.7m) -40° to 250°F (-40° to 121°C) Hot water (strap-on mounting)f 250°F (121°C) C7023N Water / Air (bullet probe) C7023P Space air temperature (button probe) C7023R C7031B Duct discharge air (rigid copper averaging sensor) Duct discharge air C7031D Hot or chilled water 5 in. (127 mm) C7031G -2006 Outdoor air C7031G -2014d -40° to 250°F 12 ft (3.7m) or 24 (-40° to 121°C) ft (7.3m) 6 in. (152 mm) -40° to 250°F (-40° to 121°C) 10K Ohms NTC @ 77° F Type III — 250°F (121°C) 1097 at 77° (25°C)c 2.1 (3.9) 40° to 350°F (4° to 115°C) 370°F (187°C) 1097 at 77° (25°C)c 2.1 (3.9) — -40° to 120°F (-40° to 49°C) 120°F (49°C) 1715 at 90°F (32°C)c 2.2 (3.4) Outdoor air — -40° to 120°F (-40° to 49°C) 120°F (49°C) 3484 at 77°F (25°C)c 2.1 (3.9) C7031J Duct discharge air (averaging sensor with 4 elements) 12 ft (3.7m) 40° to 180°F (4° to 82°C) 250°F (121°C) 1097 at 77° (25°C)c 2.1 (3.9) C7041B Duct discharge air 6 in. (152 mm) or -40° to 250°F 12 in. (305 mm) (-40° to 121°C) 250°F (121°C) 20K Ohms NTC at 77°F (25°C)e — C7041C Duct discharge air 18 in. (457 mm) C7041D Hot or chilled water b 5 in. (127 mm) C7041F Outdoor air — C7041J Duct discharge air (averaging sensor with 4 elements) 12 ft (3.7m) -40° to 158°F (-40° to 70°C) -40° to 250°F (-40° to 121°C) C7041K C7041N C7041P C7041R Hot water (strap-on mounting)f — Water / Air (bullet probe) — Space air temperature (button probe) Duct discharge air (rigid copper averaging sensor) 12 ft (3.7m) or 24 ft (7.3m) 3 63-2590—05 SERIES 2000 ELECTRONIC TEMPERATURE SENSORS a Control sensitivity in ohms per degree F (per degree C) for element operating range. Order immersion well separately (50001774-001) c Resistance increases as temperature increases. d Use with T7350 Commercial Thermostat. e Nonlinear resistance decreases as temperature increases. f Not equipped with well; temperature sensed at surface of pipe. b 63-2590—05 4 SERIES 2000 ELECTRONIC TEMPERATURE SENSORS Sensor Resistance Table 2. Typical Resistance of Sensor Models. Typical Resistance (in ohms) C7021 Sensors (10K Ohm NTC Type II) C7023 Sensors (10K Ohm NTC Type III) C7031 Sensors (1097 Ohms PTC) C7041 Sensors (20K ohm NTC) At 41°F (5°C) 25,392 23,467 1,020 54,200 At 50°F (10°C) 19,901 18,789 1,039 41,758 At 59°F (15°C) 15,712 15,137 1,059 32,427 At 68°F (20°C) 12,493 12,268 1,078 25,370 At 77°F (25°C) 10,000 10,000 1,097 20,000 At 86°F (30°C) 8,057 8,196 1,117 15,856 At 95°F (35°C) 6,531 6,754 1,136 12,654 1-13/16 (46) 1-11/16 (43) C7031B: 5-11/16 (145) C7021B, C7023B, C7041B: 11-5/8 (295) C7021B, C7023B, C7041C: 17-5/8 (448) 3/16 (4) 1 (26) 7/8 (22) 5/16 (8) 1 (26) 7/16 (12) 11/16 (18) 5/8 (16) 4 (102) 3/8 IN.-16 THREAD SPACER 1/8 NPSM (3) SENSOR M22821 Fig. 2. Dimensions of the C7021P, C7023P, C7041P in in. (mm) 1-11/16 (43) 5.75 ± 0.25 (146) 3-7/8 (99) 15/16 (23) 3/4 (19) 2-5/16 (59) 1/8 INCH NPSM STRAIGHT THREADS FOAM PAD [8] 1/2 INCH CONDUIT KNOCKOUTS 4-3/16 (107) 1-59/64 (49) SINGLE GANG RACO COVER [2] 1/64 (5) X 5/8 (16) MOUNTING HOLES M27010A 3-57/64 (99) Fig. 1. C7021B/C, C7023B/C, C7041B/C dimensions in in. (mm). 2-19/64 (58) 1-5/32 (29) 2-3/32 (53) 4-3/16 (106) M27006 Fig. 3. C7031B dimensions in in. (mm) 5 63-2590—05 SERIES 2000 ELECTRONIC TEMPERATURE SENSORS 3-5/8 (91) 2-1/4 (57) 1 (25) 3/4 (19) 8-5/16 (211) 5 (127) 7/8 (22) M22132 Fig. 4. C7031G, C7021F, C7023F, C7041F dimensions in in. (mm). 1-11/16 (43) 6-11/16 (170) 1-11/16 (43) 2-5/16 (59) 5 (127) 1/4 (6) 1/2 NPSM (13) 4-3/16 (107) 4 (70) M22596 Fig. 5. C7021D, C7023D, C7031D, C7041D dimensions in in. (mm) NOTE: The C7021D, C7023D, C7041D uses the 50001774001 Well Assembly. See Fig. 4 for dimensions. FITS 1/2 NPT TAPPED HOLE 1/2 NPSM INTERNALLY THREADED 3/8 (10) 1 (26) 3/4 (19) 4 (102) M27052 Fig. 6. 50001774-001 Immersion Well dimensions in in. (mm) 63-2590—05 6 SERIES 2000 ELECTRONIC TEMPERATURE SENSORS 1-11/16 (43) 1 1-13/16 (46) 3-7/8 (99) 15/16 (23) 7/16 (12) 1-11/16 (43) 2-5/16 (59) 4-3/16 (107) 3/4 (19) 4 (70) 1/8 NPSM (3) 1 DEPENDING ON THE MODEL, THE ELEMENT LENGTH IS EITHER 12 FT (366 CM) OR 24 FT (732 CM). M22818 Fig. 7. C7021R, C7023R, C7041R dimensions in in. (mm). 4-3/16 (107) 1-1/2 (38) 2-5/16 (59) 1-1/2 (38) 9/16 (14) 7-1/8 (182) 5 (127) 1-11/16 (43) 2-5/16 (59) 4-3/16 (107) 1 1 1-1/4 (32) 4 (70) MAXIMUM PIPE DIAMETER SHOWN. MINIMUM PIPE DIAMETER: 1-5/8 (41) COPPER PLATE FOAM PAD M22134 Fig. 8. C7021K, C7023K, C7041K dimensions in in. (mm). 7 63-2590—05 SERIES 2000 ELECTRONIC TEMPERATURE SENSORS PROBE 1 X Ø 1/32 (1) 6 FT ± 6 IN (1829 ±152) STRIP LENGTH 2X 1/4 (6) 2 ± 1/2 (51 ± 13) CONDUCTOR CABLE POTTING MATERIAL LEVEL 0.063 MAX. FROM TOP OF PROBE M33019 Fig. 9. C7021N, C7023N, C7041N dimensions in in. (mm). CAUTION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation. 1-11/16 (43) 1(25) 1-11/16 (43) 2-5/16 (59) 4-3/16 (107) Mounting The method of mounting depends on the particular application of the temperature sensor. The following procedures include outdoor, duct, immersion well and strap-on applications. Also refer to the instructions for the electronic control. 4 (70) Outdoor Mounting (C7031G, C7021F, C7023F, C7041F) The C7031G, C7021F, C7023F and C7041F sense outdoor air temperature. Mount this control where it can sense average outdoor air temperature. Normally, the north side of a building provides a suitable location. 4 THERMISTORS PLACED ON A 12 FOOT (3.7M) WIRE. NOTE: These sensors are weatherproof for outdoor use. Knockouts allow for 1/2 in. conduit connection. M22133 Fig. 10. C7021J, C7023J, C7031J, C7041J dimensions in in. (mm). 3. 4. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. Installer must be a trained, experienced service technician. After installation is complete, check out product operation as provided in these instructions. 63-2590—05 Make wiring connections using two wire nuts. Reattach the wiring box cover. Duct Mounting When Installing this Product... 2. Remove and set aside the wiring box cover. Mount the sensor to standard 1/2 in. conduit. NOTE: Mount sensor so that the element points down. 3. 4. INSTALLATION 1. 1. 2. 8 The C7031B, C7031J, C7021B/C/J, C7023B/C/J, C7041B/C/J can be mounted in a duct to sense air temperature. IMPORTANT Select a spot for the sensor where it will be exposed to average duct air temperature. Avoid locations where stratification can cause sensing errors. C7021B,C/C7023B/C, C7041B/C MOUNTING 1. Cut a hole in the duct just large enough to accept the sensing element. 2. Use the sensor case to mark the locations of the pilot holes for the mounting screws. 3. Drill the pilot holes and fasten the sensor to the duct. SERIES 2000 ELECTRONIC TEMPERATURE SENSORS C7021R, C7023R, C7041R MOUNTING 1. Install two supports inside the duct to hold the averaging element. 2. Cut a 7/8 in. (22 mm) hole in the side of the duct. 3. Insert the averaging element into the duct through the hole. 4. Fasten the terminal box to the outside of the duct and thread the element through the hole and into the duct. 5. Use plastic wire ties to fasten the element to the supports. Seal the hole around the element with a rubber grommet. 6. Secure the end of the element to the duct on the support to prevent continuous flexing or abrasion. C7021J, C7023J, C7031J, C7041J MOUNTING SENSOR SENSING ELEMENTS (4) PLASTIC TIES (5) GROMMET (NOT INCLUDE) COPPER TUBING 1 WITH SENSING ELEMENTS (4 OR 9) SUPPORTS (2) DUCT M8929A SENSOR Fig. 11. Duct cross section showing method of installing C7021J, C7023J, C7031J, C7041J Averaging Electronic Sensor. 1. 2. 3. 4. 5. Install two supports inside the duct to hold the averaging element. Cut a 7/8 in. (22 mm) hole in the side of the duct to insert the averaging element. Fasten the terminal box to the outside of the duct and thread the element through the hole and into the duct. Use plastic wire ties to fasten the element to supports. Seal the hole around the element with a rubber grommet. Secure the end of the element to the duct on the support to prevent continuous flexing or abrasion. IMPORTANT To assure that the C7021J, C7023J, C7031J, C7041J senses average duct temperature, position the temperature elements approximately as shown in Fig. 11. Do not allow the elements to touch or be close to the duct sides. NOTE: When the sensor is used as a deck sensor in a multizone system, be sure to space the elements equally in the duct midstream as shown in Fig. 12. Install one C7021J, C7023J, C7031J, C7041J just upstream from the cold deck zone dampers and the other C7021J, C7023J, C7031J, C7041J upstream from the hot deck zone dampers. Position the thermistors to sense the average deck temperature. SENSOR SENSING ELEMENTS (4) PLASTIC TIES (5) DUCT SUPPORTS (2) 1 NUMBER OF ELEMENTS DEPENDS ON LENGTH OF COPPER TUBING. Fig. 13. Duct cross section showing method of installing C7021R, C7023R, C7041R Averaging Electronic Sensor. IMPORTANT To ensure that the C7021R, C7023R, C7041R senses average duct temperature, position the temperature elements approximately as shown in Fig. 13. Do not allow the elements to touch or be close to the duct sides. NOTE: When the sensor is used as a deck sensor in a multizone system, be sure to space the elements equally in the duct midstream as shown in Fig. 14. Install one C7021R, C7023R, C7041R just upstream from the cold deck zone dampers and the other C7021R, C7023R, C7041R upstream from the hot deck zone dampers. Position the thermistors to sense the average deck temperature. SENSOR GROMMET (NOT FURNISHED) M22820 COPPER TUBING WITH SENSING ELEMENTS (4 OR 9) 1 M8928A DUCT Fig. 12. Duct cross section showing method of installing C7021J, C7023J, C7031J, C7041J in a multizone system. DUCT 1 NUMBER OF ELEMENTS DEPENDS ON LENGTH OF COPPER TUBING. M22819 Fig. 14. Duct cross section showing method of installing C7021R, C7023R, C7041R in a multizone system. 9 63-2590—05 SERIES 2000 ELECTRONIC TEMPERATURE SENSORS Immersion Well Mounting (C7021D, C7023D, C7031D, C7041D) The C7031D Sensor includes an immersion well. The C7021D, C7023D, and C7041D sensors do not include a well. For the C7021D, C7023D, and C7041D, order the well as an accessory (part no.: 50001774-001). When used on a boiler, follow the manufacturer instructions for location. If a tapped hole is not provided for the immersion well, provide one as follows: 1. Drain boiler and drill a 23/32 in. (18 mm) hole at the selected location. 2. Cut threads in the hole with a 1/2 in. (13 mm) by 14 NPT tap. makes contact before mounting (remove insulation from the pipe at the point of installation if necessary). Thermal compound is recommended with the strap-on C7021K, C7023K, C7041K Sensor. Locate the sensor on the discharge pipe within 3 feet (0.9m) of the boiler. See Fig. 16. SENSOR COPPER PLATE MUST MAKE GOOD CONTACT WITH METAL PIPE In other installations, mount the immersion well in an elbow with a heel outlet as shown in Fig. 15. 1. Drain the system, if you have not already done it, and open the tapped hole. 2. Put pipe joint compound on the threads of the immersion well and screw it into the tapped hole or elbow, tightening it securely. 3. Refill the system and check for leaks. WORM GEAR Mount the C7021D, C7023D, C7031D and C7041D into the well: 2. 3. M22136 Fig. 16. Strap-on mounting of C7021K, C7023K, C7041K Sensor. NOTE: Mounting using previously installed Honeywell wells (part no.: 32005960-001) requires an adapter (part no.: 50001775-001). 1. PIPE When an adapter is required, first thread it into the well no more than one or two turns. Slide the sensor into the well. Rotate the sensor to thread it tightly into the adapter and the adapter tightly into the well. NOTE: Insulation around the contact area increases sensor accuracy. Button Probe Mounting The C7021P, C7023P, C7041P Button Probe Sensor design simplifies mounting into a variety of standard structural materials. The locking nut can be used to secure the probe. See Fig. 18. SENSING ELEMENT (SEALED IN STAINLESS STEEL TUBE INSIDE OF INSERTION WELL) The plastic spacer helps insulate the probe from drywall, wood, or other material in which the probe is mounted. The spacer is sized to fit snugly into 1/2 in. metal conduit. See Fig. 17. 1/2 NPT (13) NOTES: — — M22135 Fig. 15. Method of mounting C7021D, C7023D, C7031D, C7041D Sensor. The plastic spacer is threaded for easy installation. Use of both the locking nut and spacer requires cutting spacer to shorter length. C7041P MOUNTING RECOMMENDATIONS Determine the proper location based upon the following: — Mount the probe to an inside wall approximately 54 in. (1372 mm) from the floor (or in the specified location) to allow exposure to the average zone temperature. — Do not mount the probe to an outside wall, a wall containing waterpipes, or near air ducts. — Avoid locations exposed to register discharge air, or radiation from lights, appliances, or the sun. Strap-On Mounting (C7021K, C7023K, C7041K) Strap-on mounting is well-suited for retrofit applications where installation costs can be reduced by not draining the system. The C7021K, C7023K, C7041K Sensor mounts on metal pipes from 1-5/8 inch to five inches in diameter using the straps supplied. Clean the surface of the pipe where the sensor 63-2590—05 10 M22797 Fig. 17. Mounting sensor in conduit. SERIES 2000 ELECTRONIC TEMPERATURE SENSORS CAUTION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation. WALL IMPORTANT 1. All wiring must agree with applicable codes, ordinances and regulations. 2. Do not mount sensor in incorrect environment. 3. Wire according to the applicable controller instructions. OPERATION AND CHECKOUT Operation M22799 The C7041 Temperature Sensors are designed for use with XL500, XL100, XL50, XL15, XL10, and Honeywell LCBS Controllers or any controller requiring 20K ohm NTC non-linear input. As the temperature at the C7041 Sensor increases, the resistance of the sensor decreases, causing the controller to operate and offset the temperature change. Fig. 18. Mounting sensor in wall with nut only. Bullet Probe Sensor Mounting (C7021N, C7023N, C7041N) The bullet probe sensor is a water-resistant sensor that provides a cost-effective solution for surface contact temperature measurement of conditioned water pipes, low pressure steam or refrigerant lines. These sensors are ideal for applications where immersion wells are not practical to install. These sensors can also be use to sense air temperature. WIRING The C7021 Temperature Sensors are designed for use with the TB7600, TB7300, and TB7200 Series Communicating Thermostats or any controller requiring a 10K ohm NTC Type II input. The C7023 Temperature Sensors are designed for use with WEBs-AX I/O Modules or any controller requiring a 10K ohm NTC Type III input. Checkout Refer to the applicable controller instructions when checking out the complete heating and cooling systems. CAUTION Erratic System Operation Hazard. Failure to follow proper wiring practices can introduce disruptive electrical interference (noise). Keep wiring at least one foot away from large inductive loads such as motors line starters, lighting ballasts, and large power distribution panels. Shielded cable is required in installations where these guidelines cannot be met. Ground shield only to grounded controller case. 11 To check out the sensors, move the thermostat or remote setpoint potentiometer below the temperature of the cooling or heating medium. Watch the motor, valve or damper for the correct movement. 63-2590—05 SERIES 2000 ELECTRONIC TEMPERATURE SENSORS Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 customer.honeywell.com ® U.S. Registered Trademark © 2011 Honeywell International Inc. 63-2590—05 M.S. Rev. 08-11 Printed in United States
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Assemble, Print high-res Author : Honeywell ECC Technical Communications Create Date : 2011:07:19 22:27:51Z Modify Date : 2011:08:01 09:44:57-05:00 Subject : Product Data XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37 Format : application/pdf Description : Product Data Title : 63-2590—05 - Series 2000 Electronic Temperature Sensors Creator : Honeywell ECC Technical Communications Producer : Acrobat Elements 9.0.0 (Windows) Creator Tool : FrameMaker 9.0 Metadata Date : 2011:08:01 09:44:57-05:00 Document ID : uuid:3b59e32e-660c-404f-a6d4-1d6ed0c812fb Instance ID : uuid:5d3f5800-4b99-a145-80fe-27855b66c61f Page Mode : UseOutlines Page Count : 12EXIF Metadata provided by EXIF.tools