Honeywell Switch R182J Users Manual 60 2481 R182J, R482J, R845A, R847A, R882J, RA89A, RA823A Switching Relays

99628-Attachment 99628-Attachment 99628-Attachment 085267 Batch8 unilog cesco-content

Honeywell Switch R482J 60-2481

R847A to the manual c656da92-dacf-4adf-a860-b09ecf04497e

2015-01-23

: Honeywell Honeywell-Honeywell-Switch-R182J-Users-Manual-261936 honeywell-honeywell-switch-r182j-users-manual-261936 honeywell pdf

Open the PDF directly: View PDF PDF.
Page Count: 6

DownloadHoneywell Honeywell-Honeywell-Switch-R182J-Users-Manual- 60-2481 - R182J, R482J, R845A, R847A, R882J, RA89A, RA823A Switching Relays  Honeywell-honeywell-switch-r182j-users-manual
Open PDF In BrowserView PDF
R182J, R482J, R845A, R847A,
R882J, RA89A, RA832A
Switching Relays
These relays provide intermediate or heavy
duty service in a wide variety of switching configurations.

■ Relays with 24V control coils: Rl82J, R882J, R847A,
RA89A, RA832A, and R845A.

■ Heavy duty relays: R847J.

■ Relays with line voltage control coils: R482J.

■ R847A has flexible internal leads to provide either
spst or spdt switching.

■ Relays with internal 24V transformer: R182J,
RA89A, RA832A, R845A, and R847A.

■ RA832A has contacts for low voltage and
millivoltage (Powerpile®) use.

■ Relays for use with an external 24V supply: R882J.

CONTENTS
Specifications ................................................. 2
Ordering Information ..................................... 2
Installation ..................................................... 3
Service and Checkout ..................................... 6

J.H. • Rev. 10-94
1
• ©Honeywell Inc. 1994 • Form Number 60-2481—2

R182J, R482J, R845A, R847A, R882J, RA89A, RA832A
SPECIFICATIONS • ORDERING INFORMATION

Specifications
IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the
listed specifications Also, this product is tested and
calibrated under closely controlled conditions, and
some minor differences in performance can be expected if those conditions are changed.

replacement value. TRADELINE model specifications are
the same as those of standard models except as noted below.
TRADELINE MODELS AVAILABLE:
R182J—120 and 240V models.
R482J—120 and 240V models.
R845A—120V models.
R847A—120 and 240V models.
RA89A—24V controller.
RA832A—120 and 240V models.
ADDITIONAL FEATURES: TRADELINE pack with cross
reference label and special instructions.
STANDARD MODELS: See Table 1.

TRADELINE® MODELS
TRADELINE models are selected and packaged to
provide ease of stocking, ease of handling, and maximum

TABLE 1—SWITCHING RELAY SPECIFICATIONS.

Models
R182J
R482J

a

Voltage
(50/60 Hz)

Switch
Action

Control
Circuit

Coil
Voltage
(Vac at
50/60 Hz)

For 24V thermostat control
of line voltage devices.

120

Dpdt

3-wire

24

Controlled by a line
voltage controller

120

Application

Relay Coil
Current
(A)
0.40 a

240
2-wire

208/240
Dpst

Contact
Ratings (A)
AFL ALR
7.4

44.4

3.7

22.2

120

0.08

7.4

44.4

208/240

0.04

3.7

22.2

24

0.40

7.4

44.4

R845A

For hot water zone control
systems or spst control of
two separate loads.

120

R847A

Provides switching for
high-current loads such as
cooling compressors.

120

22

100

240

10

50

R882J

For use with separate low
voltage power source.

24

Dpdt

7.4

44.4

RA89A

For switching one line
voltage load.

120

Spst

10.2

61.2

RA832A

For switching two line
voltage loads having a
common power source.

120

Dpst

7.4

44.4

3.7

22.2

240

See footnote on page 3.

Ordering Information
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the Tradeline
Catalog or price sheets for complete ordering number, or specify—
1. Order number.
2. Accessories, if desired.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1. Your local Home and Building Control Sales Office (please check the white pages of your phone directory).
2. Home and Building Control Customer Logistics
Honeywell, Inc., 1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386 (612) 951-1000
In Canada—Honeywell Limited/Honeywell Limitee, 740 Ellesmere Road, Scarborough, Ontario M1P2V9. International Sales and
Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico,
Netherlands, Spain, Taiwan, United Kingdom, U.S.A.

60-2481—2

2

R182J, R482J, R845A, R847A, R882J, RA89A, RA832A
SPECIFICATIONS • INSTALLATION
a

IMPORTANT: The transformer on the R182 can overheat when used with a series 20 thermostat if the
total resistance of the thermostat (including thermostat wire and thermostat contact resistance) exceeds
2.5 ohms, add a 100 ohm, 10 watt resistor between
the W and R terminals. Table 2 gives maximum
thermostat wire runs; if longer runs are necessary,
measure the resistance or add a 100 ohm, 10 watt
resistor across terminals W and R.
See Table 2 for the ratings of built-in transformer (all

Fig. 1—Approximate mounting dimensions in
in. [mm].
4
5
1 [29]
32

1
[108]
4

7
8
[48]

1

transformers are rated at 120/240V, 50/60 Hz).
TABLE 2—TRANSFORMER RATINGS.
Transformer

Rating (watts)

R847A

7.0

RA89A

5.0

RA832A

—

R845A

—

R182J

6.5

7
[22] DIAMETER
8

3
[2] DIAMETER
32
1
[13] DIAMETER
2

KEYHOLE TYPE
MOUNTING HOLE

1
2
[114]

4

1
4
[133]

5

FINISH: Gray enamel.
KNOCKOUTS:
Case bottom: (2) RA89A, RA832A, R845A; (3) Rl82J,
R482J, R882J.
All models have 1 wiring hole in case top.
All knockouts are for 1/2 in. [12.7 mm] conduit.
APPROVALS:
Underwriters Laboratories Inc. Listed: RA89A; RA832A,
R882J; R845A: File no. E4436, Guide no. XAPX.
R482J: File no. E14480, Guide no. NLDS.
R847A: File no. SA481, Guide no. SDFY.
Canadian Standards Association Certified: R482J; R882J;
R847A: File no. LR1620.

3
[10]
8

1
3 [89]
2
7
[6] DIAMETER MOUNTING HOLE
32

3 [10]
8

15
2
16
[75]
7
8
[48]

1

25
[20]
32

1

3
[35]
8

KNOCKOUT FOR
1/2 (13) CONDUIT (3)

M3823

Installation
WHEN INSTALLING THIS PRODUCT …
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazardous
condition.
2. Check the ratings given in the instructions and on the
product to make sure the product is suitable for your
application.
3. Installer must be a trained, experienced service
technician.
4. After completing installation, use these instructions
to check out product operation.

WARNING
ELECTROCUTION HAZARD.
CAN CAUSE PROPERTY DAMAGE,
SEVERE INJURY, OR DEATH.
Transformer core not bonded.
Disconnect power supply before wring to prevent
electrical shock or equipment damage.

3

60-2481—2

R182J, R482J, R845A, R847A, R882J, RA89A, RA832A
INSTALLATION
MOUNTING
For replacement, mount the relay in the same location as
the old control. If this is a new installation, locate the relay
vertically on a solid wall or partition as near as possible to
the device to be controlled. Select a location that is easily
accessible for installation and service.

TABLE 3—WIRE LENGTH SPECIFICATIONS.

Feet

Metres

Feet

Metres

22

120

38

60

18

20

200

61

100

30.5

18

300

91.5

1150

45.6

16

500

152.5

250

76

14

800

244

400

122

NOTE: To reduce possible transformer hum and relay
noise that can be amplified by mounting surfaces of
sheetmetal, plasterboard, and similar materials, place
rubber or felt washers between the case and the mounting surface.
l. Position the relay and mark the mounting holes. See
Fig. 1.
2. Start a screw for the keyhole type mounting hole in
the upper right-hand corner. Turn down screw within about
l/8 in. [3.2 mm] of the surface.
3. Hang the relay on the screw, position the case, and
start the bottom screw.
4. Tighten both screws.

Length of Run to
Thermostat
(2 wires)

Total Wire
Length

AWG Wire
Size
(Number)

Fig. 3—Internal schematic and typical hookup
for RA832A.
LOW VOLTAGE (CLASS 2)
2-WIRE THERMOSTAT

AUXILIARY TO LOW
OR MILLIVOLTAGE
(POWERPILE) LOAD
RA832A

IMPORTANT: The switching relay terminals are approved for use with copper wires only.
All wiring must comply with all applicable electrical
codes, ordinances, and regulations. Follow any instructions
furnished with the controlled equipment.
See Figs 2 through 10 for hookup diagrams for these
relays. When two or more devices are to be controlled in
parallel, the total current must not exceed the relay load
rating. Fig. 11 is an internal view of the RA832A, showing
terminal locations and barriers.
Never connect load terminals to a load that takes more
current than the amount listed in the electrical ratings on the
relay. See Table 3 for wiring length specifications.

T

T

2

1

L2

1

4

LOAD 2
(OPTIONAL)

LOAD 1

Fig. 4—Internal schematic and typical hookup
for R182J.
R182J
W

T

3

L1
HOT

X

LOW VOLTAGE (CLASS 2)
2-WIRE THERMOSTAT

R
3
OHMS

RA89A (SPST)

X

1 POWER SUPPLY. PROVIDE OVERLOAD PROTECTION
AND DISCONNECT MEANS AS REQUIRED.
M3821

Fig. 2—Internal schematic and typical hookup
for RA89A.

T

X

B
K1
K1

RA89A

2

K2

JUMPER REMOVED
2

1

3

4

JUMPER
2

1

L1

3

4

L2

1

L2

1

L1
HOT

POWER SUPPLY. PROVIDE OVERLOAD PROTECTION
AND DISCONNECT MEANS AS REQUIRED.

2

COMPLETE WIRING AS SHOWN ABOVE.

3

LOAD

1

L1
L2
(HOT)

TO LOAD

1

4

6

7

TO LOAD

L1
HOT

CONTROLLER
(IF USED)

L2

2

K2

K1

M3819

1

N.O.

LOAD
N.C.

N.O.

N.C.

1

POWER SUPPLY. PROVIDE OVERLOAD PROTECTION AND
DISCONNECT MEANS AS REQUIRED.

2

N.O. CONTACTS MAKE BEFORE N.C CONTACTS BREAK,
AND N.C. CONTACTS MAKE BEFORE N.O. CONTACTS BREAK.
M8232

60-2481—2

4

R182J, R482J, R845A, R847A, R882J, RA89A, RA832A
INSTALLATION

Fig. 5—Thermostat connections for R182J.
THREE-WIRE
LOW VOLTAGE
(SERIES 10)
THERMOSTAT 1
W

R

THREE-WIRE
LOW VOLTAGE
(SERIES 20)
2
THERMOSTAT

B

B

Fig. 7—Schematic diagram showing R845A in
multizone, forced hydronic heating system.
This arrangement is suitable for any number
of additional zones.

TWO-WIRE
LOW VOLTAGE
(SERIES 80)
THERMOSTAT

HYDRONIC HEATING
CONTROL TERMINALS

R

W

TO ADDITIONAL R845A
RELAYS FOR OTHER ZONES

T

RA845A RELAY

THERM. THERMOSTAT
ZONE 1
T
W

X

R

B

W

R

X

R

X

W

B

2
THERMOSTAT
ZONE 2

1

ZC

B

4
ZP
R182J

R182J

R182J

3
B1
BURNER BURNER
CONTROL
B2

JUMPER

5
6

1 MAKES CONTACT ON TEMPERATURE FALL ONLY.
C1

2 MAKES CONTACT ON BOTH A TEMPERATURE RISE AND FALL.

CIRC.

CIRCULATOR
ZONE 1

M8233A

CIRCULATOR
ZONE 2

C2
L1
HOT

1
1

LINE

Fig. 6—Internal schematic and typical hookup
for R482J.

2

R482J

2
3

L2

1 POWER SUPPLY. PROVIDE OVERLOAD PROTECTION
AND DISCONNECT MEANS AS REQUIRED.
2 IF CONTROLLING TWO LOADS, USE:
3 AND 4 FOR LINE VOLTAGE LOAD
5 AND 6 FOR LINE OR LOW VOLTAGE LOAD
3 IF USING LOW VOLTAGE, USE A SEPARATE TRANSFORMER.

3

1

CONTROLLER
1
L1
(HOT)
L2

2

4

5

Fig. 8—R845A hookup for controlling two
loads.

3

3

LOW VOLTAGE (CLASS 2)
2-WIRE THERMOSTAT

6

7

8

M3822

2

R845A
N.O. N.C. COM.
TO LOAD

N.O.

T

T

2

1

N.C. COM.

TO LOAD

1

POWER SUPPLY. PROVIDE OVERLOAD PROTECTION
AND DISCONNECT MEANS AS REQUIRED.

2

CONTROLLER (IF USED) MUST BE SNAP ACTION OR
MERCURY SWITCH TYPE.

3

N.O. CONTACTS MAKE BEFORE N.C CONTACTS BREAK,
AND N.C. CONTACTS MAKE BEFORE N.O. CONTACTS BREAK.

4

3

5

6

3
1

M8234

L2

5

L1
HOT

2

1
TO
POWER

LOAD 1

1
TO
POWER

LOAD 2

1

POWER SUPPLY. PROVIDE OVERLOAD PROTECTION
AND DISCONNECT MEANS AS REQUIRED.

2

WHEN CONTROLLING TWO LOADS, USE 3 AND 4
FOR LINE VOLTAGE LOAD AND 5 AND 6 FOR LINE
OR LOW VOLTAGE LOAD.

3

IF USING LOW VOLTAGE, USE A SEPARATE
TRANSFORMER.

M3820

60-2481—2

R182J, R482J, R845A, R847A, R882J, RA89A, RA832A
INSTALLATION • SERVICE AND CHECKOUT

Fig. 9—Internal schematic and hookup for
R847A.

Fig. 11—Internal view of RA832A Switching
Relay.

LOW VOLTAGE (CLASS 2)
2-WIRE THERMOSTAT

T

X

T

X

R847A
T

T

L2

L1

4

3

7

6

4

RELAY

24V TRANSFORMER

4
3

1
L1
(HOT)

L2

2

1
TO
POWER

LOAD 1

1
TO
POWER

LOAD 2

1

POWER SUPPLY. PROVIDE OVERLOAD PROTECTION
AND DISCONNECT MEANS AS REQUIRED.

2

WHEN CONTROLLING TWO LOADS, USE 3 AND 4
FOR LINE VOLTAGE LOAD AND 5 AND 6 FOR LINE
OR LOW VOLTAGE LOAD.

3

IF USING LOW VOLTAGE, USE A SEPARATE
TRANSFORMER.

4

10 AMP CONTACT RATING OR 20 AMP WHEN POLES
ARE CONNECTED IN PARALLEL.
M8231B

2

1

3

4
M3824

Fig. 10—Internal schematic and hookup for
R882J.

Service and Checkout

CONTROLLER

LOW VOLTAGE
SOURCE

1. Never use oil on any part of the relay coil or contacts.
2. Keep the cover on the relay during normal operation
and remove only for service and checkout.
3. Relay contacts require no cleaning; contacts close
with a wiping action and are self-cleaning. They may turn
black after being in service for some time; however, this
discoloration does not prevent proper operation.
4. After installation is complete, operate system through
at least one cycle from the controller to make certain the
relay controls the equipment as intended.

R882J
2

1

3

4

5

3

3

N.O. N.C. COM.
LOAD

7

8

N.O.

6

N.C. COM.

LOAD
M8235

Home and Building Control
Honeywell Inc.
1985 Douglas Drive North
Golden Valley, MN 55422

Home and Building Control
Honeywell Limited—Honeywell Limitée
740 Ellesmere Road
Scarborough, Ontario
M1P 2V9

Printed in U.S.A.

60-2481—2

6

Helping You Control Your World

QUALITY IS KEY



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Copy, Extract, Assemble, Print high-res
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Create Date                     : 1998:07:23 08:29:43Z
Creator Tool                    : Adobe PageMaker 6.0
Modify Date                     : 2007:05:07 13:49:25-05:00
Metadata Date                   : 2007:05:07 13:49:25-05:00
Format                          : application/pdf
Description                     : Product Data
Creator                         : H&BC Technical Communications
Title                           : 60-2481 - R182J, R482J, R845A, R847A, R882J, RA89A, RA823A Switching Relays
Keywords                        : 
Producer                        : Acrobat Distiller 3.01 for Power Macintosh
Document ID                     : uuid:b536907f-f38e-47bf-a86d-091c827ca710
Instance ID                     : uuid:7fa55e65-998d-4e18-89b4-c5ed84c7c46a
Page Count                      : 6
Subject                         : Product Data
Author                          : H&BC Technical Communications
EXIF Metadata provided by EXIF.tools

Navigation menu