Honeywell Switch R182J Users Manual 60 2481 R182J, R482J, R845A, R847A, R882J, RA89A, RA823A Switching Relays
99628-Attachment 99628-Attachment 99628-Attachment 085267 Batch8 unilog cesco-content
Honeywell Switch R482J 60-2481
R847A to the manual c656da92-dacf-4adf-a860-b09ecf04497e
2015-01-23
: Honeywell Honeywell-Honeywell-Switch-R182J-Users-Manual-261936 honeywell-honeywell-switch-r182j-users-manual-261936 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 6
Download | |
Open PDF In Browser | View PDF |
R182J, R482J, R845A, R847A, R882J, RA89A, RA832A Switching Relays These relays provide intermediate or heavy duty service in a wide variety of switching configurations. ■ Relays with 24V control coils: Rl82J, R882J, R847A, RA89A, RA832A, and R845A. ■ Heavy duty relays: R847J. ■ Relays with line voltage control coils: R482J. ■ R847A has flexible internal leads to provide either spst or spdt switching. ■ Relays with internal 24V transformer: R182J, RA89A, RA832A, R845A, and R847A. ■ RA832A has contacts for low voltage and millivoltage (Powerpile®) use. ■ Relays for use with an external 24V supply: R882J. CONTENTS Specifications ................................................. 2 Ordering Information ..................................... 2 Installation ..................................................... 3 Service and Checkout ..................................... 6 J.H. • Rev. 10-94 1 • ©Honeywell Inc. 1994 • Form Number 60-2481—2 R182J, R482J, R845A, R847A, R882J, RA89A, RA832A SPECIFICATIONS • ORDERING INFORMATION Specifications IMPORTANT: The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the listed specifications Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed. replacement value. TRADELINE model specifications are the same as those of standard models except as noted below. TRADELINE MODELS AVAILABLE: R182J—120 and 240V models. R482J—120 and 240V models. R845A—120V models. R847A—120 and 240V models. RA89A—24V controller. RA832A—120 and 240V models. ADDITIONAL FEATURES: TRADELINE pack with cross reference label and special instructions. STANDARD MODELS: See Table 1. TRADELINE® MODELS TRADELINE models are selected and packaged to provide ease of stocking, ease of handling, and maximum TABLE 1—SWITCHING RELAY SPECIFICATIONS. Models R182J R482J a Voltage (50/60 Hz) Switch Action Control Circuit Coil Voltage (Vac at 50/60 Hz) For 24V thermostat control of line voltage devices. 120 Dpdt 3-wire 24 Controlled by a line voltage controller 120 Application Relay Coil Current (A) 0.40 a 240 2-wire 208/240 Dpst Contact Ratings (A) AFL ALR 7.4 44.4 3.7 22.2 120 0.08 7.4 44.4 208/240 0.04 3.7 22.2 24 0.40 7.4 44.4 R845A For hot water zone control systems or spst control of two separate loads. 120 R847A Provides switching for high-current loads such as cooling compressors. 120 22 100 240 10 50 R882J For use with separate low voltage power source. 24 Dpdt 7.4 44.4 RA89A For switching one line voltage load. 120 Spst 10.2 61.2 RA832A For switching two line voltage loads having a common power source. 120 Dpst 7.4 44.4 3.7 22.2 240 See footnote on page 3. Ordering Information When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the Tradeline Catalog or price sheets for complete ordering number, or specify— 1. Order number. 2. Accessories, if desired. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Home and Building Control Sales Office (please check the white pages of your phone directory). 2. Home and Building Control Customer Logistics Honeywell, Inc., 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 (612) 951-1000 In Canada—Honeywell Limited/Honeywell Limitee, 740 Ellesmere Road, Scarborough, Ontario M1P2V9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 60-2481—2 2 R182J, R482J, R845A, R847A, R882J, RA89A, RA832A SPECIFICATIONS • INSTALLATION a IMPORTANT: The transformer on the R182 can overheat when used with a series 20 thermostat if the total resistance of the thermostat (including thermostat wire and thermostat contact resistance) exceeds 2.5 ohms, add a 100 ohm, 10 watt resistor between the W and R terminals. Table 2 gives maximum thermostat wire runs; if longer runs are necessary, measure the resistance or add a 100 ohm, 10 watt resistor across terminals W and R. See Table 2 for the ratings of built-in transformer (all Fig. 1—Approximate mounting dimensions in in. [mm]. 4 5 1 [29] 32 1 [108] 4 7 8 [48] 1 transformers are rated at 120/240V, 50/60 Hz). TABLE 2—TRANSFORMER RATINGS. Transformer Rating (watts) R847A 7.0 RA89A 5.0 RA832A — R845A — R182J 6.5 7 [22] DIAMETER 8 3 [2] DIAMETER 32 1 [13] DIAMETER 2 KEYHOLE TYPE MOUNTING HOLE 1 2 [114] 4 1 4 [133] 5 FINISH: Gray enamel. KNOCKOUTS: Case bottom: (2) RA89A, RA832A, R845A; (3) Rl82J, R482J, R882J. All models have 1 wiring hole in case top. All knockouts are for 1/2 in. [12.7 mm] conduit. APPROVALS: Underwriters Laboratories Inc. Listed: RA89A; RA832A, R882J; R845A: File no. E4436, Guide no. XAPX. R482J: File no. E14480, Guide no. NLDS. R847A: File no. SA481, Guide no. SDFY. Canadian Standards Association Certified: R482J; R882J; R847A: File no. LR1620. 3 [10] 8 1 3 [89] 2 7 [6] DIAMETER MOUNTING HOLE 32 3 [10] 8 15 2 16 [75] 7 8 [48] 1 25 [20] 32 1 3 [35] 8 KNOCKOUT FOR 1/2 (13) CONDUIT (3) M3823 Installation WHEN INSTALLING THIS PRODUCT … 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After completing installation, use these instructions to check out product operation. WARNING ELECTROCUTION HAZARD. CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH. Transformer core not bonded. Disconnect power supply before wring to prevent electrical shock or equipment damage. 3 60-2481—2 R182J, R482J, R845A, R847A, R882J, RA89A, RA832A INSTALLATION MOUNTING For replacement, mount the relay in the same location as the old control. If this is a new installation, locate the relay vertically on a solid wall or partition as near as possible to the device to be controlled. Select a location that is easily accessible for installation and service. TABLE 3—WIRE LENGTH SPECIFICATIONS. Feet Metres Feet Metres 22 120 38 60 18 20 200 61 100 30.5 18 300 91.5 1150 45.6 16 500 152.5 250 76 14 800 244 400 122 NOTE: To reduce possible transformer hum and relay noise that can be amplified by mounting surfaces of sheetmetal, plasterboard, and similar materials, place rubber or felt washers between the case and the mounting surface. l. Position the relay and mark the mounting holes. See Fig. 1. 2. Start a screw for the keyhole type mounting hole in the upper right-hand corner. Turn down screw within about l/8 in. [3.2 mm] of the surface. 3. Hang the relay on the screw, position the case, and start the bottom screw. 4. Tighten both screws. Length of Run to Thermostat (2 wires) Total Wire Length AWG Wire Size (Number) Fig. 3—Internal schematic and typical hookup for RA832A. LOW VOLTAGE (CLASS 2) 2-WIRE THERMOSTAT AUXILIARY TO LOW OR MILLIVOLTAGE (POWERPILE) LOAD RA832A IMPORTANT: The switching relay terminals are approved for use with copper wires only. All wiring must comply with all applicable electrical codes, ordinances, and regulations. Follow any instructions furnished with the controlled equipment. See Figs 2 through 10 for hookup diagrams for these relays. When two or more devices are to be controlled in parallel, the total current must not exceed the relay load rating. Fig. 11 is an internal view of the RA832A, showing terminal locations and barriers. Never connect load terminals to a load that takes more current than the amount listed in the electrical ratings on the relay. See Table 3 for wiring length specifications. T T 2 1 L2 1 4 LOAD 2 (OPTIONAL) LOAD 1 Fig. 4—Internal schematic and typical hookup for R182J. R182J W T 3 L1 HOT X LOW VOLTAGE (CLASS 2) 2-WIRE THERMOSTAT R 3 OHMS RA89A (SPST) X 1 POWER SUPPLY. PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED. M3821 Fig. 2—Internal schematic and typical hookup for RA89A. T X B K1 K1 RA89A 2 K2 JUMPER REMOVED 2 1 3 4 JUMPER 2 1 L1 3 4 L2 1 L2 1 L1 HOT POWER SUPPLY. PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED. 2 COMPLETE WIRING AS SHOWN ABOVE. 3 LOAD 1 L1 L2 (HOT) TO LOAD 1 4 6 7 TO LOAD L1 HOT CONTROLLER (IF USED) L2 2 K2 K1 M3819 1 N.O. LOAD N.C. N.O. N.C. 1 POWER SUPPLY. PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED. 2 N.O. CONTACTS MAKE BEFORE N.C CONTACTS BREAK, AND N.C. CONTACTS MAKE BEFORE N.O. CONTACTS BREAK. M8232 60-2481—2 4 R182J, R482J, R845A, R847A, R882J, RA89A, RA832A INSTALLATION Fig. 5—Thermostat connections for R182J. THREE-WIRE LOW VOLTAGE (SERIES 10) THERMOSTAT 1 W R THREE-WIRE LOW VOLTAGE (SERIES 20) 2 THERMOSTAT B B Fig. 7—Schematic diagram showing R845A in multizone, forced hydronic heating system. This arrangement is suitable for any number of additional zones. TWO-WIRE LOW VOLTAGE (SERIES 80) THERMOSTAT HYDRONIC HEATING CONTROL TERMINALS R W TO ADDITIONAL R845A RELAYS FOR OTHER ZONES T RA845A RELAY THERM. THERMOSTAT ZONE 1 T W X R B W R X R X W B 2 THERMOSTAT ZONE 2 1 ZC B 4 ZP R182J R182J R182J 3 B1 BURNER BURNER CONTROL B2 JUMPER 5 6 1 MAKES CONTACT ON TEMPERATURE FALL ONLY. C1 2 MAKES CONTACT ON BOTH A TEMPERATURE RISE AND FALL. CIRC. CIRCULATOR ZONE 1 M8233A CIRCULATOR ZONE 2 C2 L1 HOT 1 1 LINE Fig. 6—Internal schematic and typical hookup for R482J. 2 R482J 2 3 L2 1 POWER SUPPLY. PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED. 2 IF CONTROLLING TWO LOADS, USE: 3 AND 4 FOR LINE VOLTAGE LOAD 5 AND 6 FOR LINE OR LOW VOLTAGE LOAD 3 IF USING LOW VOLTAGE, USE A SEPARATE TRANSFORMER. 3 1 CONTROLLER 1 L1 (HOT) L2 2 4 5 Fig. 8—R845A hookup for controlling two loads. 3 3 LOW VOLTAGE (CLASS 2) 2-WIRE THERMOSTAT 6 7 8 M3822 2 R845A N.O. N.C. COM. TO LOAD N.O. T T 2 1 N.C. COM. TO LOAD 1 POWER SUPPLY. PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED. 2 CONTROLLER (IF USED) MUST BE SNAP ACTION OR MERCURY SWITCH TYPE. 3 N.O. CONTACTS MAKE BEFORE N.C CONTACTS BREAK, AND N.C. CONTACTS MAKE BEFORE N.O. CONTACTS BREAK. 4 3 5 6 3 1 M8234 L2 5 L1 HOT 2 1 TO POWER LOAD 1 1 TO POWER LOAD 2 1 POWER SUPPLY. PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED. 2 WHEN CONTROLLING TWO LOADS, USE 3 AND 4 FOR LINE VOLTAGE LOAD AND 5 AND 6 FOR LINE OR LOW VOLTAGE LOAD. 3 IF USING LOW VOLTAGE, USE A SEPARATE TRANSFORMER. M3820 60-2481—2 R182J, R482J, R845A, R847A, R882J, RA89A, RA832A INSTALLATION • SERVICE AND CHECKOUT Fig. 9—Internal schematic and hookup for R847A. Fig. 11—Internal view of RA832A Switching Relay. LOW VOLTAGE (CLASS 2) 2-WIRE THERMOSTAT T X T X R847A T T L2 L1 4 3 7 6 4 RELAY 24V TRANSFORMER 4 3 1 L1 (HOT) L2 2 1 TO POWER LOAD 1 1 TO POWER LOAD 2 1 POWER SUPPLY. PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED. 2 WHEN CONTROLLING TWO LOADS, USE 3 AND 4 FOR LINE VOLTAGE LOAD AND 5 AND 6 FOR LINE OR LOW VOLTAGE LOAD. 3 IF USING LOW VOLTAGE, USE A SEPARATE TRANSFORMER. 4 10 AMP CONTACT RATING OR 20 AMP WHEN POLES ARE CONNECTED IN PARALLEL. M8231B 2 1 3 4 M3824 Fig. 10—Internal schematic and hookup for R882J. Service and Checkout CONTROLLER LOW VOLTAGE SOURCE 1. Never use oil on any part of the relay coil or contacts. 2. Keep the cover on the relay during normal operation and remove only for service and checkout. 3. Relay contacts require no cleaning; contacts close with a wiping action and are self-cleaning. They may turn black after being in service for some time; however, this discoloration does not prevent proper operation. 4. After installation is complete, operate system through at least one cycle from the controller to make certain the relay controls the equipment as intended. R882J 2 1 3 4 5 3 3 N.O. N.C. COM. LOAD 7 8 N.O. 6 N.C. COM. LOAD M8235 Home and Building Control Honeywell Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Home and Building Control Honeywell Limited—Honeywell Limitée 740 Ellesmere Road Scarborough, Ontario M1P 2V9 Printed in U.S.A. 60-2481—2 6 Helping You Control Your World QUALITY IS KEY
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Assemble, Print high-res XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 1998:07:23 08:29:43Z Creator Tool : Adobe PageMaker 6.0 Modify Date : 2007:05:07 13:49:25-05:00 Metadata Date : 2007:05:07 13:49:25-05:00 Format : application/pdf Description : Product Data Creator : H&BC Technical Communications Title : 60-2481 - R182J, R482J, R845A, R847A, R882J, RA89A, RA823A Switching Relays Keywords : Producer : Acrobat Distiller 3.01 for Power Macintosh Document ID : uuid:b536907f-f38e-47bf-a86d-091c827ca710 Instance ID : uuid:7fa55e65-998d-4e18-89b4-c5ed84c7c46a Page Count : 6 Subject : Product Data Author : H&BC Technical CommunicationsEXIF Metadata provided by EXIF.tools