Honeywell Thermostat 96D Users Manual
96d1 891d4013-3a75-4e0d-90a2-aaca294b0ea0 Honeywell Thermostat 96d User Guide |
2015-01-23
: Honeywell Honeywell-Honeywell-Thermostat-96D-Users-Manual-262100 honeywell-honeywell-thermostat-96d-users-manual-262100 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 80
Download | |
Open PDF In Browser | View PDF |
User Manual 96d Controller Unit Controller Unit 96d User Manual M-511401 8/10 Notices and Trademarks Copyright by Honeywell International Inc. August 2010 While this information is presented in good faith and believed to be accurate, Honeywell disclaims the implied warranties of merchantability for a particular purpose and makes no express warranties except as may be stated in its written agreement with and for its customers. In no event is Honeywell liable to anyone for any indirect, special or consequential damages. The information and specifications in this document are subject to change without notice. This manual covers software version 3.086. Honeywell Analytics 405 Barclay Boulevard Lincolnshire, Illinois 60069 M-511401 8/10 96d User Manual Honeywell iii Symbol Definitions The following table lists the symbols used in this document to denote certain conditions: Symbol Definition ATTENTION: Identifies information that requires special consideration TIP: Identifies advice or hints for the user, often in terms of performing a task REFERENCE _ INTERNAL: Identifies an additional source of information within the bookset. CAUTION Indicates a situation which, if not avoided, may result in equipment or work (data) on the system being damaged or lost, or may result in the inability to properly operate the process. CAUTION: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices. CAUTION: Symbol on the equipment refers the user to the product manual for additional information. The symbol appears next to required information in the manual. WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in serious injury or death. WARNING symbol on the equipment refers the user to the product manual for additional information. The symbol appears next to required information in the manual. M-511401 8/10 96d User Manual Honeywell v INTRODUCTION ..............................................................9 Intended Use ........................................................................................... 9 Receiving and Unpacking........................................................................ 9 Installation Instructions ...................................................................... 10 Basic Guidelines .................................................................................... 10 Surface Mount Installation ..................................................................... 11 Wiring Details .................................................................................... 12 Power Connections ........................................................................... 14 Communication Connections ............................................................ 14 Settings for Specific Transmitters ...................................................... 14 Relay Output ..................................................................................... 15 Jumper Use Instructions........................................................................ 16 GETTING STARTED ......................................................17 Initial Startup ......................................................................................... 17 Datalogger (SDcard) ............................................................................. 17 Programming Interface...................................................................... 18 Keypad Functions.................................................................................. 18 LED Definitions ...................................................................................... 19 System Operation .................................................................................. 19 SYSTEM PROGRAMMING ............................................20 Tx Info Menu ..................................................................................... 23 Ident Menu ............................................................................................ 24 Product and Sensor Types .................................................................... 26 COM Menu ............................................................................................ 27 Scale Menus (1 and 2) .......................................................................... 28 Detection Menu ..................................................................................... 29 Display Menu ......................................................................................... 30 Alarm A, B and C Menus ....................................................................... 31 Servicing and Operating Menus ............................................................ 32 Status Code........................................................................................... 33 Erase Current Tx ................................................................................... 33 Change Tx Address ............................................................................... 34 Groups Menu......................................................................................... 35 Creating Groups .................................................................................... 36 Deleting Groups .................................................................................... 37 M-511401 8/10 96d User Manual Honeywell vii Event Menu .......................................................................................38 Action Menu ........................................................................................... 40 Delays Menu ..........................................................................................41 Latch Mode ............................................................................. 42 Conditions .............................................................................................. 43 Status..................................................................................................... 47 Database................................................................................................ 47 Acquisition Menu ...............................................................................48 Starting and Stopping Tx Logging ..........................................49 Starting and Stopping Event Logging ..................................... 50 Copy Menu ........................................................................................ 51 Configuration .....................................................................................51 Parameters ............................................................................................ 52 System Log Menu ..................................................................................53 Config Menu ...................................................................................... 54 Network Menu ...................................................................................59 Remote Calibration ................................................................................61 Tests Menu........................................................................................ 63 Test Sequence....................................................................................... 65 Normal Mode .........................................................................................67 Single Tx Mode ...................................................................................... 67 Debug Mode .......................................................................................... 67 Simulation Mode ....................................................................................68 BACnet Menu ....................................................................................69 Wireless Network Menu .....................................................................70 Specifications ....................................................................................71 WARRANTY ................................................................... 73 Warranty Statement ...............................................................................73 Warranty Conditions ..............................................................................73 Consumer Claims ..................................................................................74 viii 96d User Manual Honeywell M-511401 8/10 Introduction Introduction The 96D controllers act as nerve centers for gas detection networks, providing continuous monitoring for up to 96 connected units (plus 1 301ADI). Since the controllers are factory programmed to the owner’s specifications, installation is limited simply to mounting and connecting them. Once installed and connected, the controllers allow the user to monitor, adjust, or reconfigure an entire network of units. Intended Use The controller is intended to monitor an entire gas detection network around the clock. The unit offers logging capabilities, creating log files of all transmitter concentrations and alarms for analysis. The unit is also equipped with grouping or zoning capabilities that allow users to query and monitor specific groups of transmitters or specific transmitter zones. Receiving and Unpacking Upon receiving the controller unit: • • • Check that the package is undamaged Carefully open the package. Locate the packing slip or purchase order and verify that all items on the order are present and undamaged Note: If the package or any of its contents are damaged, please refer to the Warranty section at the back of the manual for instructions. M-511401 8/10 96d User Manual Honeywell 9 Introduction Installation Instructions Installation Instructions Basic Guidelines Follow these instructions to the letter to ensure that the equipment will function properly. Failure to respect these guidelines will release Honeywell Analytics from any responsibility in the event of improper functioning: • • • • • 10 Locate all units in areas easily accessible for service. Avoid locations where instruments are subject to vibrations Avoid locating units near sources of electromagnetic interference Avoid locating units in areas subject to significant temperature swings Verify local requirements and existing codes that may impact choice of location. 96d User Manual Honeywell M-511401 8/10 Introduction Installation Instructions Surface Mount Installation It is recommended that controllers be installed 5 feet (1.5 m) above the floor, at approximate eye level. 16 cm 6 5/16” 33.6 cm 13 1/4 1.52 m 5.0 ft Mark the holes as shown: • • • • Height markers 6 13/32” apart Width markers 10 9/16” apart Pre-drill 1/4” mounting holes as needed Securely mount the 96D using the appropriate screws Wiring for the unit must be passed through the knock-outs provided at the bottom of the unit. M-511401 8/10 96d User Manual Honeywell 11 Introduction Wiring Details Wiring Details The diagram below provides the details required to connect the 96d to a gas detection network. Details concerning power supply, cables, capacities, etc., are provided in the Specifications section at the back of this manual. 9XOFDLQ,QF 9$&:35% 0DGHLQ&DQDGD . / - - SD Card - 1& 12 Wireless communication module /(' -3 5(6(7 5(/$< ' ' - 5(/$< . - 12 - /(' $/$50B$ /(' 6,/(1&( %= / 6: $/$50B% /(' LCD screen - 5 /(' 5 5 - 5& $/$50B& /(' End-of-line jumper position /(' /(' - - )$8/7 /(' 5,*+7 0$'(,1&$1$'$ 6: 6: 6: (6& 5 6: & (2/ 5 - 5& (7+(51(702'8/( '2:1 5& 5 9RXW (2/ (2/ 9LQ 5& 5& 5(/$< 3&%&:5$ /()7 5(/$< 5(6(7 - - . . /(' 6: - (2/ 6+'1 32:(5 (17(5 83 6: End-of-line specification: The E.O.L. jumper for channels 1-2-3-4 must always be in E.O.L. position. 7; /(' 5; /(' 5 - - - - 9 9 9 9 - $ % $ % 6+,(/' 6+,(/' B4 Channel 4 (not used) A4 A 2 Channel 2 B1 Channel 1 A1 VNEXT V+ 12 $ % $ % B2 V+ PREVIOUS V- B3 A 3 Channel 3 6 Grounding screw 4 5 Always respect minimum voltage requirements at device RISK OF ELECTRIC SHOCK 1& 12 1& RELAY OUTPUTS 2 3 Normally open 3+5 4+6 Normally 1 closed 1+3 2+4 RISK OF ELECTRIC SHOCK COMMUNICATION BacNet/IP MODULE (-BIP option) Communication Wire Gauge: 2-24 AWG (Belden 9841) Twisted and shielded cable 2000 feet (600 m) per channel T-tap: 65 feet (20 m) / T-tap 130 feet (40 m) total Wireless Communication: ISM worldwide Indoor range 30m Ethernet: 10/100-compatible with 10Base-T interface, RJ-45 Visual Indicators: Green LED LINK Yellow LED ACT Channel Specifications: Channel 1-2: Modbus,Vulbus protocol Channel 3: Modbus protocol only Communicates only with Vulcain transmitters Channel 4: Modbus output Communicates only with VA301BDCM 12 96d User Manual Honeywell M-511401 8/10 Introduction Wiring Details The connectors, or ports, on the PCB allow various wiring to be connected to the controller. The wiring includes power, communication, BACNet and relays, each with an assigned position (and number) on the board: J22 Power Input: Connect the power supply to the controller (see Wiring Details for cabling diagrams) J23, J24 Communication inputs: Connect communication cables to channels 1 through 3. Relay Outputs 1-4: Depending on the desired configuration, connect the relay cables to either N.O. or N.C. SHDN jumper Place the jumper over the Shutdown header pins to reset or restart the system. EOL Resistors 1-4: Place the jumper over the header pins to create the connection to attenuate communication echoes. M-511401 8/10 96d User Manual Honeywell 13 Introduction Power Connections Power Connections The 96D requires a power range of 17-27 Vac, 50/60 Hz (8.64 VA), 1836 Vdc, 350 mA @24 Vdc (8.4 VA). Polarization is not important in either AC or DC mode. The system must be grounded on the transformer and a dedicated circuit breaker must be used. Communication Connections Communication cables must be grounded using the shield terminal, using twisted and shielded pair Belden 2-24 AWG #9841 cable (or equivalent). The network cabling can extend up to a limit of 2000 feet (609 m) per channel. The length of a T-tap can reach 65 feet (20 m), up to a maximum of 130 feet (40 m) for all T-taps. All wireless devices associated to the controller will automatically be detected and communicate with the controller using wireless communication protocols. Settings for Specific Transmitters Honeywell Sensepoint XCD Transmitters must be configured for 9600 baud, no parity, and a unique address. Honeywell XNX Universal Transmitters must be configured for 9600 baud and a unique address. Information on configuring each transmitter is in the associated technical manual. 14 96d User Manual Honeywell M-511401 8/10 Introduction Relay Output Relay Output The relay output can withstand up to 5A at 30Vdc or 250Vac (resistive load only). Relays can be used to activate horns and strobes. Although each relay is programmed with a default setting (below), they can be configured using the controller programming menu. RELAY OUTPUTS N.O. COMM Normally open N.C. Normally closed If relays are set to Normally closed, the relay is powered up with the controller and the device linked to the relay is functioning. The relay will shut down when the specified alarm condition is reached. If the relay is set to normally open, the relay will remain off when the controller is powered up and the device connected to the relay will only be activated when the specified alarm condition is reached. Note: These functions are reversed if the controller Failsafe mode has been activated. M-511401 8/10 96d User Manual Honeywell 15 Introduction Relay Output Jumper Use Instructions The jumpers on the controller PCB allow a variety of operations to be performed manually: EOL 1-4: Enables the user to add End-Of-Line jumpers that improve communication signals. Put the jumper in R position (as shown on wiring diagram) to activate the End-of-Line termination. (R provides a resistance termination and RC provides resistance and condensator termination.) SHDN: Enables the microcontroller to be reset or temporarily shut down. This function is used mainly when system wiring adjustments are needed (power off for safety). Relays These jumpers allow the relay to be tested by activating it J29-J32 without having any effect on Events. 16 96d User Manual Honeywell M-511401 8/10 Getting Started Relay Output Getting Started The controller units are customized to the purchaser’s specifications but they can be further programmed using the following menu options. Initial Startup Make sure that all wiring has been completed according to specifications in the wiring details before powering up the unit. When all is secure, remove the SHDN jumper to power-up the unit. It should only take a few seconds until the unit is fully operative. Datalogger (SDcard) The DLC (Data Logger Card) option for the controller collects data and stores it on a digital Flash memory card (SDCard). In the event that the card memory becomes full: • • • Information logging is stopped No SDcard flag is displayed on-screen The SDcard LED blinks See the Acquisition section for more details on starting and stopping the datalogging function. CAUTION M-511401 8/10 Always deactivate datalogging function before removing the SDcard. Never remove the card when its LED is on. 96d User Manual Honeywell 17 Getting Started Programming Interface Programming Interface The front panel of the 96D provides a programming keypad (buttons) and LEDs. 96D front panel Keypad Keypad Functions Each unit has 7 keypad keys, or buttons: Arrows: ESC: Enter: Silence: 18 Used to move the cursor through the various programming fields (Up, Down, Left and Right), or to adjust the display contrast (press and hold the up or down arrow until desired contrast is reached and release). Used to exit the programming menu or to cancel a change or input. Used to access the programming menu and to modify programming fields. Turns off the controller’s buzzer. 96d User Manual Honeywell M-511401 8/10 System Programming Programming Interface System Programming The system’s Normal programming mode offers several menu options that are accessible from the main menu screen: Tx Info: Groups: Events: Acqui: Copy: Allows transmitter parameters to be programmed Allows groups of transmitters to be set up Allows events and event behavior to be programmed Allows the datalogging feature to be activated or deactivated Allows data or parameters to be copied from the (controller) configuration to parameters Config: Allows system parameters and password to be set Network: Allows actions on the network to be performed, communication statistics to be consulted, and remote calibrations to be performed Tests: Allows each device to be tested sequentially (inputs, outputs, communications, events, etc.) and operation of various parameters to be validated BACNet: Allows a device’s BACNet parameters to be set Wireless: Allows a network of wireless gas detection devices to be configured, monitored, and modified. Note: Access to the programming functions is password protected. The default password is 2967. The screen display shown below appears initially. This display can be configured to scroll among the information screens for each device connected to the controller. If one or more of the connected devices is in an alarm mode, the controller will only scroll between the main information screen and the screens for device(s) in alarm mode. In this case, you must scroll manually to view screens for other devices. 20 96d User Manual Honeywell M-511401 8/10 System Programming Programming Interface The information screen also displays icons representing certain system functions. Here is a list of possible icons and their meaning: Icon Description BACnet is not offered with the model 96d controller unit. BACnet is not offered with the model 96d controller unit. Debug: Indicates whether the controller is in debug mode (Single TX, Debug or Simulation modes). When in simulation mode, SIM appears next to this icon. Log: Indicates that either “Tx Logging” or “Event logging” is enabled. Log error: Indicates that an error occured during TX or Event logging. All logging functions are stopped. SDC: Indicates that an SDcard is present and functionning. The icon “fills” (from white to black) progressively as memory is used. A white icon indicates empty memory and black indicates full memory. SDC error: If this symbol persists for more than 5 seconds, an SD card card is present but not functioning properly. Wireless networking is not offered with the model 96d controller unit. Wireless networking is not offered with the model 96d controller unit. M-511401 8/10 96d User Manual Honeywell 21 System Programming Programming Interface Since the controller’s programming functions are password protected, it is necessary to access the login screen: • • • Press Enter to access the programming options. The password screen appears: Use the keypad Up or Down arrows to increase or decrease the value, one digit at a time, starting with the first digit When all the digits of the password are correct, press Enter to access the programming functions. PASSWORD ____ The first MENU options screen appears. Use the keypad arrows to navigate through multiple screens to the desired function and press Enter to access it. MENU 1. Tx Info 2. Groups 3. Events 4. Aqui MENU 5. Copy 6. Config 7. Network 8. Tests MENU 9. BACNet 10. Wireless 22 96d User Manual Honeywell M-511401 8/10 System Programming Tx Info Menu Tx Info Menu Tx Info is the menu option that is dedicated to transmitter information and contains several sub-menu options. The exact list of screens will vary depending on the transmitter type. A summary is presented below with details on the following pages Ident: COM: Allows the network component’s identification information to be viewed. Allows the communication protocol to be viewed or changed Detection or Scale(1) and Scale(2): Allows the detection range and the unit of measurement parameters to be viewed and changed Display: Allows the label (or name) of a specific component to be changed Alarms: Allow alarm thresholds to be viewed and sometimes changed. There can be significant variations in this screen depending on transmitter type. Status Displays: Transmitter and node status (in hexadecimal values) Erase or Erases or changes the Current Tx: Tx address M-511401 8/10 96d User Manual Honeywell 23 System Programming Tx Info Menu Ident Menu The Ident, or identification menu allows a component’s network ID to be consulted: 1. Tx Info -Ident- 001 NotVul CO2 (IR) The upper right corner of the screen shows the component’s address. If the address of the device whose information must be viewed is known: • • • • Use the arrows to move the cursor arrow to the on-screen address Press Enter (the value can be edited while the number is flashing) Use the up or down arrows to increase or decrease the value Press Enter again to validate the entry and display the information for the desired device. The bottom left corner of the display shows the transmitter name (ex.: 301D2 - product name) and the sensor type (ex.: CH4 - methane sensor). These values can also be changed for Group or Vulbus product types. The procedure is identical for both fields: Programming or changing a product or sensor type • • • 24 Use the arrows to move the cursor to the product type field. Press Enter to select the field (the value can be modified when flashing) Use the arrows to scroll through the list of product types and press Enter when the desired product or sensor appears 96d User Manual Honeywell M-511401 8/10 System Programming Tx Info Menu Product and Sensor Types This is a list of all the (preprogrammed) product types available from the Identification option in the Tx Info menu. 1. Tx Info -Ident- 121 301W CO2 (IR) The order of the products below is not necessarily the order in which they will appear in the controller Product Types Addresses 1-96 VA301D2 90DM3R VA301IRF IRT100 EC-F9 VA201T2 VA301T GsPnt RgRt3 VA301AP VASQN8X VA301EM VA301EMRP GsPnt2 S301RLC (Std.Device)* VA901T XNX XCD VA201R VA201T 90DM2 VA201D VA301D NotVul * E3Point and 420MDBS are examples of standard devices. Note: When Group is selected as a product type, the remaining Tx INFO screens are not accessible (because each product in the group has already been individually programmed). Only the Ident and Erase current Tx screens will be available. M-511401 8/10 96d User Manual Honeywell 25 System Programming Tx Info Menu The sensor type list applies to address ranges 1-96 and is not dependent on the type of product selected. Devices in the address range from 97-170 will display a BACNet object identifier, rather than a sensor type. *An additional Product Type, simply called “Group”, represents a group created in the Groups Menu in the controller. When scrolling through the available product type list, this name will appear as many times as there are groups created in the controller (example: Group 1, Group 2, Group 3, etc.). If a group is selected as the product type, then the sensor type options are limited to MIN, MAX and MEAN. 26 96d User Manual Honeywell M-511401 8/10 System Programming Tx Info Menu COM Menu This screen displays the selected communication protocol for device addresses from 1 to 96. Each transmitter’s protocol is defined by the controller (see Network Auto-configuration section) . 1. Tx Info -COMMdbs RTU 8D 1S EP 9600 bauds 001 If a transmitter is compatible with several different protocols, it can be modified using to one of the following options: • • • • • Vulbus Mdbs ASCII 7D 2S NP 9600 bauds Mdbs RTU 8D 2S NP 9600 bauds Mdbs RTU 8D 1S NP 9600 bauds Mdbs RTU 8D 1S OP 9600 bauds When a transmitter is configured with the Modbus communication protocol, the transmitters automatically sends the programmable parameters to the controller. Note: Vulbus transmitter parameters must be programmed manually. M-511401 8/10 96d User Manual Honeywell 27 System Programming Tx Info Menu Scale Menus (1 and 2) These menus appear only for certain devices. Scale(1) allows the detection range, minimum and maximum, to be defined for the selected device. Whatever value is specified is the value that will appear at the device display (if applicable). The Minimum value is generally left at 0. Parameters for the XNX and XCD gas detectors can be viewed here but can be changed only at the transmitter. 1. Tx Info 001 -Scale(1)Max 00250 Min 00000 Scale(2) allows the factor by which to divide the scale (between 0 and 65535) and the unit of measurement for the selected scale to be determined. 1. Tx Info 001 -Scale(2)Factor 00010 Units % The factor allows precise scale limits for detection to be set. By dividing the maximum scale value in the first Scale screen (250 in this example) by 10, a scale value of 25.0 can then be displayed. The “Units” allow the unit of measurement for the device to be selected: °F: °C %RH mV V mA % ppm 28 Sets degree Farenheit as the unit of measurement Sets degree Centigrade as the unit of measurement Sets Relative Humidity as the unit of measurement Sets millivolts as the unit of measurement Sets volts as the unit of measurement Sets milliamps as the unit of measurement Sets the percentage of gas as the point unit of measurement Sets parts per million of gas as the point unit of measurement 96d User Manual Honeywell M-511401 8/10 System Programming Tx Info Menu Detection Menu The detection menu (available only for devices with addresses between 1 and 96) displays the detection range (scale: 0-100.0) and the unit of measurement (unit: %) for the selected component. If a transmitter uses the Modbus protocol, the detection parameters are automatically defined during network configuration and are not editable. Vulbus protocols must be manually defined by the programmer. The detection scale is between 0 and the maximum value (0.00) and the unit of measurement is either ppm or percent (% for oxygen and % LEL for combustibles). The detection menu is not available for the VA301R or VA301AP. 1. Tx Info -Detectionscale: 0-0.00 unit: % 001 Programming or modifying the scale range or unit: • • • Use the arrows to move the cursor to the scale or unit option Press Enter and use the arrow to increase or decrease the value Press Enter when the desired value is obtained M-511401 8/10 96d User Manual Honeywell 29 System Programming Tx Info Menu Display Menu This option allows a specific label or name to be assigned to the selected component (transmitters, relay modules, annunciators). Up to 20 characters, including spaces, can be used in the label (example: BOILER ROOM). The default Modbus transmitter labels are composed of the component (or transmitter) name, sensor type and address. Vulbus transmitter labels contain 20 blank characters (spaces). edit 301D2 30 1. Tx Info 001 -Display(20 char.max) CH4 Ad001 96d User Manual Honeywell M-511401 8/10 System Programming Tx Info Menu Alarm A, B and C Menus The screens for viewing alarm thresholds are combined in this manual. There will be either two or three levels, depending on transmitter type. If present, separate “MIN” and “MAX”levels permit manual control of the hysteresis of each alarm. Normally, the “MAX” level is set greater than “MIN.” However, alarms can be made to trigger on falling concentration (as with oxygen) by setting the “MAX” threshold smaller than the “MIN” threshold. With certain transmitters, only one threshold will be displayed. Additionally, with certain transmitters, the alarm thresholds are readonly at the controller. These thresholds can be set only at the transmitter. These are typical screens: Typical screen for viewing alarms A or B on XCD and XNX transmitters Typical screen for viewing or changing alarm A, B, or C thresholds on other transmitters. M-511401 8/10 96d User Manual Honeywell 31 System Programming Tx Info Menu Servicing and Operating Menus These functions vary depending on the transmitter type. These displays show the total time the device has been in service and the amount of time remaining until the next required calibration or replacement. 32 96d User Manual Honeywell M-511401 8/10 System Programming Tx Info Menu Status Code These screens display transmission or node status and sensor status for the selected transmitter. This read-only information can assist service personnel in troubleshooting. The XNX and XCD gas detectors will report the warning or fault number (iFaultWarnNumber) in hexidecimal on the third line. These transmitters will also report the monitoring state (iMonitoringState) in the fourth line. See the transmitter documentation for interpretation of fault numbers and monitoring states. Typical display for XNX or XCD Typical display for other transmitters Erase Current Tx This function allows the configuration to be erased or the Tx address for the displayed component to be changed. Note: Selecting erase current Tx only erases the current device entry Tx Info configuration. No other data is erased. 1. Tx Info 001 erase current Tx Change Tx Address M-511401 8/10 96d User Manual Honeywell 33 System Programming Tx Info Menu Change Tx Address Selecting Change Tx Address allows users to move a device from one TX address to another: • • • Use the arrows to scroll to Change Tx Address and press Enter to select In the next screen, scroll to the address number and press Enter to select Use the up or down arrows to increase or decrease the address value and press Enter to validate the new address. The Change Tx address option is only available (active) for device address 1 to 96 and if there is a Modbus device connected. If the address is valid, the screen will display “Processing”. If the address is invalid, the screen will display “Invalid Tx” and return to the Change Tx Address screen (the address for GasPoint devices cannot be changed) A final screen will display either “Error” or “Success” (re-start procedure if Error is displayed). 1. Tx Info 001 erase current Tx Change Tx Address 1. Tx Info To address: 001 001 1. Tx Info 001 Processing... Note: If a device address is changed to one already associated with another device, the existing data will be overwritten. Customers should know their network’s address assignments and be careful when changing a Tx address. Delete the original Tx address to avoid duplicate entries.This feature is not supported with XNX and XCD transmitters. 34 96d User Manual Honeywell M-511401 8/10 System Programming Groups Menu Groups Menu Programming groups of transmitters allows several units to be combined which then enables actions (events) to be taken based on a series of units rather than each unit, individually. MENU 1. TxInfo 2. Groups 3. Events 4. Acqui 2. Groups[----] [----] [----] [----] [----] empty all groups 001 [----] [----] A group is a stack containing the addresses from each of the transmitters included in the group. Groups are displayed in a single line; if a group contains more than four components, the arrows must be used to scroll left and right of the display window to view all members of a group. The cursor in the Group screen is represented by the blinking brackets ( ). Any information between the brackets can be edited. M-511401 8/10 96d User Manual Honeywell 35 System Programming Groups Menu Creating Groups • • • • • Use the arrows to move the cursor to a group line and press Enter The field can be edited when the brackets stop blinking and the word “end” blinks Use the up or down arrows to scroll through the list of all units connected to the 96D, until the desired address is displayed . Press Enter again to validate the address. The address is added to the group and the bracket is shifted one position to the right. The process can be repeated until all the desired transmitters in the group (up to 126) have been added. The address for each transmitter added in the Tx Info menu is available when creating groups. Note: Groups created in the Groups menu will appear in the product type list (Tx Info - Ident screen) as “Group xx” (the number assigned to the group when it was created). 36 96d User Manual Honeywell M-511401 8/10 System Programming Groups Menu Deleting Groups Use the empty all groups command to delete all groups previously programmed in the controller. Single groups can be deleted with a simple procedure: • • • Scroll to the first transmitter in the group list, Select the transmitter (its address blinks) and scroll to (erases the entry andmarks the end of the stack) Press enter and the group is emptied. This procedure makes it possible to delete one, several or all entries previously included in a group. Note: Up to 126 groups, with a maximum of 128 members each, can be created. M-511401 8/10 96d User Manual Honeywell 37 System Programming Event Menu Event Menu Though the controller has a default setting for Event configuration (as shown below), the Event menu is programmable. Event programming lets specific actions to be defined: Action: Delay: Conditions: Coverage period: Status: disabled: Database: 38 What will be done if programmed criteria are reached Defines the length of time to wait before taking an action on an event and time to wait after an event has returned to normal before the action output is returned to normal state. AND, OR or none (---); equations that allow more detailed control of an event Determines the period during which the event is applicable Disables or enables a programmed Event Erases the selected event or all events 96d User Manual Honeywell M-511401 8/10 System Programming Event Menu M-511401 8/10 96d User Manual Honeywell 39 System Programming Event Menu Action Menu Actions are comprised of two parameters: 3. Events -ActionTarget: Ctrl Relay: #01 Target Relay 001 Indicates which component is responsible for the action to be taken; Tx (transmitter) Re (Relay/Annunciator) Ctrl (Controller) Indicates which of three possible outputs will be activated when the event is true; #XX (activates the component’s #xx relay), Buzzer (activates the component’s audible alarm) ALL (activates the relays and audible alarms) Example: Tx 007 detects a concentration exceeding the set values. The target (controller) triggers relay 1 connected to that event (a fan perhaps). 40 96d User Manual Honeywell M-511401 8/10 System Programming Event Menu Delays Menu This option allows Before and After settings that will delay the activation or deactivation of an action to be programmed. Before After Delays the action for the specified length of time. If the condition persists beyond this delay, the defined action is executed. The time to wait after an event has returned to normal before returning action output to normal state. The after delay also offers a Latch option, described below. 3. Events -DelaysBefore: 99min After: 01min 001 Before and After delays can be configured at either 30 or 45 seconds or from 1 to 99 minutes, in one minute increments. Five dashes (-----) indicates that no delay has been programmed. • • • • Use the keypad arrows to scroll to the desire option Press Enter to select the option Use the keypad arrows to scroll through the second or minute settings Press Enter at the desired setting. The delay is set. M-511401 8/10 96d User Manual Honeywell 41 System Programming Event Menu Latch Mode • • • • • The Latch function is executed on an Event state It is possible to select the Latch mode by changing the after delay to “latch” The Event stays active until the Silence keypad button is pressed The Silence keypad button has two functions: Silence the buzzer and unlatch the event. When the Silence keypad button is pressed, events in Latch mode are unlatched and reevaluated. If the Event condition persists, the Event remains active and returns to Latch mode. If the condition does not persist, the event is deactivated. Note: If the Event has a Before delay and the Silence button is pressed while the Event conditions are still true, the buzzer will be silenced only for the length of the programmed delay. 42 96d User Manual Honeywell M-511401 8/10 System Programming Event Menu Conditions Conditions are the parameters that define what makes an Event true. Each condition is defined by four elements and can be combined with other conditions to provide greater flexibility. A condition, as in the example provided below, defines: IF at least 1/3 of group 36 detects concentrations greater than 2.01% of specified gas AND all of group 03 detects a concentration greater than 2.99% of gas, then the specified action (Actions were set at the first Event screen) for that Event will be triggered. Since the display screens offer limited space, scroll left and right to view and edit further information. Condition programming screens AND 3. Events Gr036 2.01% 001 1/3 > 3. Events Gr003 2.99% 001 all > AND The portion of the Events condition screen that is within the brackets is divided into four editable list fields: M-511401 8/10 96d User Manual Honeywell 43 System Programming Event Menu The top left portion contains the statistic quantifier (available only for Groups) that take only the specified part of the group into the equation. Options available in this field are: all: mean: max: min: 1/4: includes all transmitters in the group includes the average concentration for the group’s transmitters includes the group’s maximum concentration includes the group’s minimum concentration includes at least a quarter of the group’s transmitters that meets set conditions 1/3: includes at least a third of the group’s transmitters that meets set conditions 1/2: includes at least half of the group’s transmitters that meets set conditions 2/3: includes at least two thirds of the group’s transmitters that meets set conditions 3/4: includes at least three quarters of the group’s transmitters that meets set conditions 1 or +: at least one or more than one of the group’s transmitters that meets set conditions 44 96d User Manual Honeywell M-511401 8/10 System Programming Event Menu The bottom left portion contains the logic, or operator, quantifier that determines how conditions are calculated. Options available in this field are: Operator Symbol --= <= < >= > != max min Meaning No operator Equal to Equal to or smaller than Smaller than Equal to or larger than Larger than Not equal to When the maximum value is reached, an action is triggered. It will not be deactivated until levels fall below minimum value When concentrations fall below minimum value, an action is triggered. It will not be deactivated until concentrations rise above set maximum value The top right portion contains the source, which defines what device or group of devices the Event will be based on. The list provides the following options: GrAll: Includes all transmitters (see note) Gr_ _ _: Includes only the devices in the specified group (see note) Tx000: Includes only the specified transmitter (connected to the controller) Clock: Includes only information gathered between the specified times. Selecting clock sets a condition that is applied only between the start and end time frame. It is possible to set one condition screen to specific parameters and the second to clock, which means that the specified condition will trigger an event only if it occurs during the set time period. Note: Clicking on the magnifying glass to the right of a Group number on the display opens a view of the Group for consultation or editing. Press Esc to close the group view and return to the Event condition screen. M-511401 8/10 96d User Manual Honeywell 45 System Programming Event Menu The bottom right portion contains the operand, which defines what device or group of devices on which the Event will be based. The list provides the following options: OFF ON: Fault: Used for status on binary inputs (ex.: used with 301ADI) Used for status on binary inputs (ex.: used with 301ADI) Bases trigger on maintenance alarm, communication failure or device failure Alrm A: If the chosen device or group has an Alarm A or Alarm 1, an event will be triggered. Alrm B: If the chosen device or group has an Alarm B or Alarm 2, an event will be triggered. Alrm C: If the chosen device or group has an Alarm C, an event will be triggered. The Coverage Period screen allows the period that will be covered by the Event to be defined. (The time frames for each of these periods can be defined in the controller Config menu.) This option provides two further selection fields: Day definition field: allows All day, Daytime, or Nighttime to be selected Week definition field: Weekend, Working Days, All week 3. Events 001 -Coverage PeriodAll day All week 1. Use the keypad up or down arrows to scroll to either All day or All week 2. Press Enter to select. The value can now be changed 3. Use the keypad up ro down arrows to scroll through options (see above) 4. Press Enter to select. 46 96d User Manual Honeywell M-511401 8/10 System Programming Event Menu Status This screen displays the current event status and allows it to be either enabled or disabled, depending on the current status. Enable event:This is a “toggle” switch; press Enter to change the value from Enable to Disable and vice versa 3. EVENT -Status : disabledEnable event . 001 After going through all the steps and programming an event, this screen will display “Enable event”. Press Enter to activate all the parameters and enable the Event. If an existing Event is being consulted, this screen would display “Disable event”. Press Enter to disable an Event (it will not be deleted but will not function). The programming of this Event is always present, which means that it easily can be reactivated by scrolling to this screen and pressing Enter. Database This screens displays the options linked to the database: Erase current event:Lets user erase the current event Erase all events:Lets user erase all events 3. Events -DatabaseErase current event Erase all events M-511401 8/10 96d User Manual Honeywell 001 47 System Programming Acquisition Menu Acquisition Menu The Acquisition mode is only accessible when there is an SD card present (controllers with the Data Logging, or DLC function). It is used to enable or disable the logging of system Events or transmitter information. The information is logged (or recorded) on an SD card. Intervals or conditions must be defined before using this option. 4. Acquisition 10% threshold mode Start Tx logging Start event logging The first line of the Acquisition screen offers either : Delay mode: Threshold mode: Allows for delay intervals of 10 to 59 seconds or 1 to 60 minutes. Allows log values to be set according to set variation thresholds (based on last reading) of 3% or more, 5% or more or 10% or more of last detected concentration. If a 3% threshhold is selected, the system will not log a value at 3% but will log a value of 3.1%. Remember that the sampling rate (system refresh rate) may have an impact on logging. Here is an example of threshold logging. The logs a semi-colon delineated text files. 2005-04-27 2005-04-27 2005-04-27 2005-04-27 2005-04-27 2005-04-27 48 11:05:20;1_CO2_ppm;574;-normal-: 11:06:02;1_CO2_ppm;503;-normal-: 11:06:15;1_CO2_ppm;562;-normal-: 11:06:28;1_CO2_ppm;645;-normal-: 11:06:39;1_CO2_ppm;557;-normal-: 11:30:45;1_CO2_ppm;715;-normal-: 96d User Manual Honeywell M-511401 8/10 System Programming Acquisition Menu Starting and Stopping Tx Logging In the previous step, “Acquisition”, the frequency at which Tx logs would be recorded can be configured. To start the logging function: When “Start Tx logging” appears on the display, it indicates that the acquisition, or logging, mode is inactive. When “Stop Tx logging” appears, it indicates that Tx data is being logged. The log message is displayed on the screen according to the chosen mode and LED 1 will light up. Press the Enter keypad button to stop or start Tx logging. When Tx data is logged, the system creates files named tayymmdd.log, tbyymmdd.log and tcyymmdd.log, each representing one third of the network. The record includes the transmitter’s date, time and address, the sensor type, the concentration read, as well as the alarm status. Here is a sample of what a Tx log looks like: 2004-01-23 17;54;25; 001_CO_ppm;0;-normal-;002_NO2_ppm;1.5;-normal-;003_CO_ppm;0;-normal2004-01-23 17;55;25; 001_CO_ppm;0;-normal-;002_NO2_ppm;0.5;-normal-;003_CO_ppm;0;-normal2004-01-23 17;56;25; 001_CO_ppm;0;-normal-;002_NO2_ppm;0.5;-normal-;003_CO_ppm;0;-normal2004-01-23 17;57;25; 001_CO_ppm;0;-normal-;002_NO2_ppm;1.0;-normal-;003_CO_ppm;0;-normal2004-01-23 17;58;25; 001_CO_ppm;0;-normal-;002_NO2_ppm;1.5;-normal-;003_CO_ppm;0;-normal- The first column of the Tx log displays the date (yyyy-mm-dd) and the time (hh:mm:ss) of the log. In this example, the “Delay mode” was set to one minute intervals. The third column of the Tx log displays the transmitter address and the fourth displays the gas type, gas concentration and unit of measurement. The display then lists the next transmitter address with its gas type, concentration and unit of measurement, and so on until all the transmitters have been listed. M-511401 8/10 96d User Manual Honeywell 49 System Programming Acquisition Menu Starting and Stopping Event Logging The Acquisition menu offers an event logging option. Event Logging records controller transactions, events, Tx and alarm flags and relay status. When “Start Event logging” appears on the display, it indicates that the acquisition, or logging, mode is inactive. When “Stop Event logging” appears, it indicates that Event data is being logged. Press the Enter keypad button to stop or start Event logging. When Event data is logged, the system creates a file named evyymmdd.log. The record includes the date, time and the event. Here is a sample of what an Event log looks like: 2004-01-23 17:54:25: Event logging enable 2004-01-23 17:55:25: Event logging enabled 2004-01-23 19:05:47; Simulation sequence activated 2004-01-23 19:05:48; Tx 6 communication no more in fault 2004-01-23 19:05:48; Tx 8 communication no more in fault The first column of the Event log displays the date (yyyy-mm-dd) and time (hh:mm:ss) of the log. Column A displays the date and time of the log. In this example, the event’s “Delay mode” was set to one minute intervals. The system logs the following types of events: • • • Event Log Event status changed Alarm A, B, C, Fault, and X status changed Note: New log files are created when the existing files reach 32 000 lines or at the start of a new week (0h00 Sunday) 50 96d User Manual Honeywell M-511401 8/10 System Programming Copy Menu Copy Menu The Copy menu allows programmed parameters to be copied and transferred. Data from the SD card can be transferred to a controller or from a controller to the SD card or copy parameters from one device to the next. The Copy option offers three screens: Configuration, Parameters and System Log. Configuration If the controller is equipped with an SD card, the configuration function allows data to be transferred either from the 96D to the SD card or the reverse. This makes it possible to transfer the controller’s programming to a computer or from a computer to the controller. 5. Copy -ConfigurationConfig to SDcard SDcard to Config The first option in the configuration screen is 96D to SDcard. Selecting this option copies the controller’s configuration and parameters into a “config.ini” file 1. The second option is SDcard to 96D allows the configuration and parameters of the “config.ini” file on an SDcard to be copied to the controller. Note: The “config.ini” file contents can be modified at any time and from any computer. 1. When transferring data, the system will automatically search for an existing “config.ini” file before proceeding. If one exists, the system searches for a “config.bak” file. If found, the file is deleted. Then, the pre-existing “config.ini” file is renamed “config.bak”, making it possible to save the new “config.ini” file and keep a backup copy of the previous one. After inserting an SD card into the controller, the controller’s system looks for an existing “config.ini” file that contains an “autoload” tag equal to 1 (yes). If the tag is found, the system loads the contents of the file and resets “autoload” to 0 (no). This is a useful feature for editing the file on a computer without having any impact on the controller (such as recorded Events). M-511401 8/10 96d User Manual Honeywell 51 System Programming Configuration Parameters The “parameters” function allows one transmitter’s configuration to be copied to another or one event’s parameters to be copied to another event. This allows several devices that share identical or similar parameters to be quickly configured. 5. Copy -parametersTxInfo to TxInfo Event to Event The options within this screen are: Tx Info to Tx Info copies transmitter parameters from one device to another. Event to Event copies parameters from Event to Event. The process is identical for both options: • • • • • Select source, (the data to be copied) using the up/down keypad arrows and press Enter. When the transmitter address is flashing, use the up/down keypad buttons to search for the desired device address. Press Enter to select the new address Select the target address (where the data is to be copied to) in exactly the same way as source Select COPY and press Enter. The parameters have been copied. TxInfo to TxInfo source tx001 target tx113 COPY Event to Event source #001 target #013 COPY 52 96d User Manual Honeywell M-511401 8/10 System Programming Configuration System Log Menu The controller will record log information to its internal memory. If the controller is equipped with an SD card, the system log function allows users to save system log information to the memory card in text format. 5. Copy -System LogSysLog to SDcard When this option is selected, a log of all the last actions performed on the controller is copied to the SDcard, with the filename slyymmdd.log. This file can contain up to a maximum of 64Kb of information in text format. Once the memory card is full, the oldest log entries are erased and replaced by new entries. Here is an example of a system log: --- START of system log dump : 2007-04-18 13:19:05 --2007-04-04 18:42:06;Accessing menu; 2007-04-04 18:43:47;Event 1 definition modified; 2007-04-04 18:48:12;Exiting menu; 2007-04-04 18:54:49;System power-down; 2007-04-04 18:56:40;System power-up; 2007-04-04 19:02:44;Accessing menu; 2007-04-04 19:03:07;Event 6 definition modified; 2007-04-04 19:03:21;Exiting menu; 2007-04-05 10:51:28;Accessing menu; 2007-04-05 10:54:59;Database reset; 2007-04-05 10:55:18;Tx 25 parameters modified; 2007-04-05 10:55:29;Group 0 definition modified; 2007-04-05 10:55:36;Group 0 definition modified; 2007-04-05 10:55:46;Group 0 definition modified; 2007-04-05 10:55:55;Group 4 definition modified; 2007-04-05 10:55:57;Exiting menu; 2007-04-05 10:56:02;Accessing menu; 2007-04-05 10:56:19;Tx 24 parameters modified; M-511401 8/10 96d User Manual Honeywell 53 System Programming Config Menu Config Menu The Config menu contains several main configuration screens and is used to program the controller display mode, adjust the date and time, select the display language, change the controller access password, modify the Slave Port configuration, set the Relay Configuration, and select the AP Broadcast mode. Each main screen offers further programming options, as shown. MENU 5. Copy 6. Config 7. Network 8. Tests 6. Config Manual scroll mode Set Date and Time Menu français Date and Time 2005-11-21 11:47:36 (ISO 8601 standard) 6. Config Set User Password - 2967 Slave Port Cnfg Slave Port Cnfg Address: 001 38400 bauds Mdbs RTU 8D 2S NP 6. Config Relay Configuration AP Brdcst: auto Honeywell Relay Configuration -FailsafeAll relays Inactive Relay Configuration -Silence1 2 3 4 dis ena dis dis 6. Config Day definition Week definition Day definition -Daytimesta: 08:00 end: 17:00 Week definition -Working Dayssta: Monday end: Friday 54 96d User Manual Honeywell M-511401 8/10 System Programming Config Menu Selecting the first line of the first screen allows selection from three display modes: Manual scroll, 3-second scroll, 5-second scroll. If Manual scroll mode is chosen, the screen will only advance if you press on the arrow keypad buttons. If either 3 or 5 second scroll mode is chosen, the screens will automatically scroll display readings for all devices connected to the controller after 3 or 5 seconds. 6. Config Manual scroll mode Set Date and Time Menu français 3 or 5 second scroll modes do not prevent the keypad arrows to be used to return to a previous screen or move ahead through the screens manually. Selecting the second line allows the date and time in a new screen to be adjusted; Date and Time. When a number is flashing, the value can be changed using the up/down keypad arrows. The year, month, day and the hour, minute and second values can be changed. The controller does not manage Daylight Savings Time, therefore, users must manually adjust any time changes. Date and Time 2005-11-21 11:47:36 (ISO 8601 standard) Selecting the third line allows the display language to be changed. If the display is already in English, it will then display the Menu français option (and vice-versa). Simply scroll to the line and press Enter to change the language. M-511401 8/10 96d User Manual Honeywell 55 System Programming Config Menu The second main screen in the Config menu allows a new user password to be set and the slave port configuration to be modified. 6. Config Set User Password - 2967 Slave Port Cnfg The default password is 2967. Select Set User Password to change the password: • • • When the first digit blinks, change the value by using the up/down keypad arrows to increase or decrease the number Use the left/right keypad arrows to move from one digit to the next. When the desired password has been set, press Enter to validate it and exit the editing mode. Note: Contact Honeywell technical support for help with lost passwords at 1-800-563-2967. 56 96d User Manual Honeywell M-511401 8/10 System Programming Config Menu Scroll through the main Config menu screens using the left (previous) or right (next) keypad arrows. The third main screen in the Config menu allows the relay configuration to be set, the AP broadcast mode and to select from four separate manufacturers for the given controller. 6. Config Relay Configuration AP Brdcst: auto Honeywell When Relay Configuration is selected, two further options to configure the relays are available: The first screen, Failsafe, appears allowing the failsafe to be activated for all relays using the Enter keypad button. This function is used in case of a power failure: if power is cut, the relay will activate the connected device (ex. a light) to signal the problem. Relay Configuration -FailsafeAll relays Inactive Scrolling to the right displays the “Silence” screen that enables or disables the silence option for each relay, using the Enter keypad button. Relay Configuration -Silence1 2 3 4 dis ena dis dis M-511401 8/10 96d User Manual Honeywell 57 System Programming Config Menu The fourth screen in the Config menu allows a definition of a day and a week to be programmed. 6. Config Day definition Week definition Day and Week definition allows hours (time frames) to be defined for either Daytime and Working Days respectively. Day definition -Daytimesta: 08:00 end: 17:00 Week definition -Working Dayssta: Monday end: Friday Note: Remember, the controller uses a 24 hour clock (0:00 to 23:59). Any time changes (DST) must be made manually or through BACNet time synchronisation (BACNet module required). 58 96d User Manual Honeywell M-511401 8/10 System Programming Network Menu Network Menu The Network menu allows network device information to be either scanned or reset. This menu offers four options, divided into two screens; the first screen contains three options: Reset Database: Network Scan: Reset and Scan: Resets all network device Tx information in the database. This only resets the Tx infomation for the network device. It does not affect programmed Groups or Events. Begins an auto-detect of all network devices that allows the system to configure the Tx database for network devices (i.e. it will scan and add new devices but will not overwrite or erase the old database) Performs both previous functions simultaneously. 7. Network Reset Database Scan Network Reset and Scan Note: Once one of these options has been set, wait until the controller completes the process. Do not interrupt or stop the process once it has begun. M-511401 8/10 96d User Manual Honeywell 59 System Programming Network Menu The second Network screen offers the Statistics and Calibration options. 7. Network Statistics Calibration Selecting Statistics from the Network menu displays a screen containing the statistics for the selected device address. Statistics Valid 16 Errors 0 Timeouts 0 001 100% 0% 0% Valid: Indicates the number of valid responses for the last 16 requests Errors: Indicates the number of errors in the response for the last 16 requests Timeouts: Indicates the number of timeouts (no response) for the last 16 requests 60 96d User Manual Honeywell M-511401 8/10 System Programming Network Menu Remote Calibration The network menu also offers a Calibration option for use with devices that support network calibration. 7. Network Statistics Calibration The Calibration screen contains four (4) lines of information: Calib 007 S301M Status: Normal Set Zero Set Span 246 PPM Line 1: Line 2: Line 3: Line 4: Indicates the mode (Calib, meaning calibration), the (Modbus) address of the device to calibrate (001) and the type of device to calibrate (301D2) Indicates the status (Normal or In calib…) of the specified device Displays the function to perform (Set Zero) Displays the function to perform (Set Span) and the span gas concentration value (246 ppm) 5. On the first line, scroll to the device address and press Enter 6. Scroll through the devices to display the desired device* and press Enter to select. 7. The second line displays the device’s status 8. Scroll to select the desired function, Set Zero to set the device's zero, and press Enter to select. 9. Upon pressing Set Zero, the controller requests confirmation. Calib 007 S301M Status: Normal Set Zero Set Span 246 PPM *The device must be configured in the 96D’s database in order to be included in the device addresses displayed on screen. M-511401 8/10 96d User Manual Honeywell 61 System Programming Network Menu 10. Press Enter to confirm or Esc to cancel. If confirmed, the controller calibrates the sensor’s Zero. This takes only a few moments and the display returns to the default calibration screen. Note: Never calibrate any unit’s Zero with ambient air. Always use Nitrogen (N2) at the calibration port to calibrate the Zero. 11. To calibrate the device, scroll to Set Span** and change the span gas calibration value using this procedure; Calib 001 : 301D2 Status : Normal Set Zero Set Span 2.60 ppm a. Using the right arrow, move the cursor to xxx PPM (span value field). Press Enter to select the field (it is editable when flashing). b. Use the up or down arrows to increase or decrease the value, press Enter to validate the new value. c. Move the cursor back to Set Span and press Enter to start the calibration. Calib 001 : 301D2 Status : In calib... Set Zero Set Span 2.60 ppm The device Span is being calibrated. The screen will display the device’s status as “In calib...” until the calibration is complete. **When selecting Set Span, make sure that the device has been supplied with the appropriate calibration gas before and during the calibration process. 62 96d User Manual Honeywell M-511401 8/10 System Programming Tests Menu Tests Menu The Tests menu allows a variety of tests to be performed on components and on the network communications. It also allows the system to be operated in four different modes which, in turn, provide different functionalities. MENU 5. Copy 6. Config 7. Network 8. Tests 8. Tests Test sequence Start Sim Sequence Maximum load 1 Test sequence Relays activated Any key to continue Esc to quit 2 Test sequence BUZZER activated Any key to continue Esc to quit 3 Test sequence LEDs activated Any key to continue Esc to quit 4 Test sequence Press ‘left’ Esc to quit 5 Test sequence Display test Any key to continue Esc to quit 6 Test sequence Test Network comm. 9600 bauds Channel 1 PASSED 7 Test sequence Test done Any key to continue Simulation Sequence Start with Tx001 Confirm 8. Tests Oprt Mode: normal M-511401 8/10 96d User Manual Honeywell 63 System Programming Tests Menu The Tests menu provides four main options, divided between two screens. Each of these options offers different capabilities. The first screen presents three options: 8. Tests Test sequence Start Sim Sequence Maximum load Test sequence: Start Sim Sequence: Maximum load: Enables each output to be activated and validates operation of each controller keypad buttons, display pixels, and various communication protocols. This options starts or stops the Simulation mode, which allows a simulation of a gas concentration over an associated scale range on all transmitters. The simulated gas concentration values are local (on the controller) and do not affect logging functions. (Events will be activated for the simulation but detection devices are not affected.) Activates all controller components The second screen option is “Oprt Mode”, which offers three separate operation settings: Normal, Single Tx or Debug. 8. Tests Oprt Mode: normal Normal Single Tx: Debug: 64 Normal controller operation mode Activates the polling mode on a single transmitter. Activates the service mode to perform a calibration and to test Events without triggering actions. 96d User Manual Honeywell M-511401 8/10 System Programming Tests Menu Test Sequence When test sequence is selected from the main Tests menu, the controller will display the Test sequence screen. Test sequence Relays activated Any key to continue Esc to quit If Esc is pressed on the keypad, the main Tests menu screen will be displayed. However, to perform system tests, press any key to proceed to the first test screen. Test sequence BUZZER activated Any key to continue Esc to quit This screen tests each component individually and will advance only to the next component when a key is pressed. This option will display 13 screens. Screens 1, 2 and 3 test Relays, BUZZER and LEDs. The following six screens prompt the user to press the keypad buttons, in turn: left, right, up, down, Silence, Enter and Esc. The system will not advance until a key is pressed. Test sequence Press ‘left’ Esc to quit M-511401 8/10 96d User Manual Honeywell 65 System Programming Tests Menu The system then moves to the Display test. When the blank screen is displayed, it is testing for display pixels. Press any key to proceed to the next step. Test sequence Display test Any key to continue Esc to quit The final test that the system performs is a network communication test: Test sequence Test Network comm. 9600 bauds Channel 1 PASSED Once these tests have begun, do not interrupt or stop them. The system tests all five bauds (communication speed: 9600, 19200, 38400, 57600, 115200) and each of the 4 channels per baud. When the system has completed the test, it displays the final Tests screen. Press any key to return to the main Tests menu. Test sequence Test done Any key to continue 66 96d User Manual Honeywell M-511401 8/10 System Programming Tests Menu Normal Mode This is the system’s normal (default) operation mode. When the system is in normal mode, some values can be changed without interrupting services. When a value has been changed in any of the menu fields, the change will take effect upon returning to the main menu screen. Single Tx Mode This mode allows transmitters to be analyzed one at a time. The controller polls only the selected device, which subsequently has its information updated. This mode does not interfere with Event Evaluation functions. Debug Mode This mode allows complete system operation to be evaluated and tested without affecting operations (outside of debug mode). Events are evaluated and displayed as necessary but no action is triggered. M-511401 8/10 96d User Manual Honeywell 67 System Programming Tests Menu Simulation Mode This mode deactivates network communication Information Updates. It can be combined with any of the three previous modes (example: using the Simulation mode when in Debug mode allows the user to test the entire system [groups, events, etc] without triggering any actions or using any additional material such as gases). It allows gas concentrations to be simulated over an associated scale for each transmitter, sequentially: Alarm levels A, B and C are evaluated according to the simulated gas concentration and events are evaluated and actions are taken. This type of alarm simulation at the controller does not work with certain transmitters with falling alarms. In these cases, an alarm can be simulated at the transmitter. While in simulation mode, the controller is unaware of the device’s actual network status. This mode can be stopped at any time in the Test menu (see Normal System Operation). If one of these modes has been activated, the system will automatically return to Normal Mode after 12 hours of inactivity. (No changes will be lost.) 68 96d User Manual Honeywell M-511401 8/10 System Programming BACnet Menu BACnet Menu BACnet is not offered with the model 96d controller unit. M-511401 8/10 96d User Manual Honeywell 69 System Programming Wireless Network Menu Wireless Network Menu Wireless networking is not offered with the model 96d controller unit. 70 96d User Manual Honeywell M-511401 8/10 Specifications Specifications Power requirements 96D Operating temperature range Operating humidity range Operating altitude Network capacity Communication (length of lines) User interface Visual indicators Outputs Output rating Audible alarm Time delays Battery Enclosure Dimensions (HxWxD) Certifications M-511401 8/10 17-27 Vac, 50/60 Hz, 8.64 VA 18-36 Vdc, 350mA @ 24 Vdc (8.4 VA) -20°C to 50°C (-4°F to 122°F) 0 to 95% RH (non-condensing) Up to 3000 m (9843 ft) Up to 96 transmitters, 32 per channel Channels 1, 2 = Modbus Channel 3 = Modbus only Up to 609m (2,000 ft) per channel T-tap maximum = 20m (65 ft) per t-tap, overall total of 40m (130 feet) Graphic 122 x 32 dot matrix backlit display User friendly keypad Power Green LED Warn, Alarm, High Alarm Red LED Fault Amber LED Tx Amber LED Rx Green LED 4 DPDT relays 5A, 30Vdc or 250 Vac (resistive load) 65dBA at 1 m (3 ft) Programmable Before and After delays 3 volt lithium battery Painted aluminum 9.5” x 14” x 3.5” (24.1 x 35.6 x 8.9 cm) ANSI/UL 61010-1 CAN/CSA C22.2 No. 61010-1 ETL 116662 96d User Manual Honeywell 71 Warranty Warranty Statement All products are designed and manufactured to the latest internationally recognized standards by Honeywell Analytics under a Quality Management System that is certified to ISO 9001. Service in the field or at the customer’s premises is not covered under these warranty terms. Time and travel expenses for on-site warranty services will be charged at Honeywell Analytics’ normal billing rates. Contact your Honeywell Analytics Service Representative for information on Service Contracts. Warranty Conditions The Honeywell Analytics (HA) Limited Product Warranty only extends to the sale of new and unused products to the original buyer where purchased from HA or from a HA authorized distributor, dealer or representative. Not covered are: consumable items such as dry-cell batteries, filters and fuses or routine replacement parts due to the normal wear and tear of the product; any product which in HA’s opinion has been altered, neglected, misused or damaged by accident or abnormal conditions of operation, handling, use or severe sensor poisoning; defects attributable to improper installation, repair by an unauthorized person or the use of unauthorized accessories/parts on the product Any claim under the HA Product Warranty must be made within the warranty period and as soon as reasonably possible after a defect is discovered. If a Warranty claim is being sought it is the responsibility of the buyer to obtain a Service Event number (SE#) from HA and if practical return the product clearly marked with the SE# and a full description of the fault. HA, at its sole discretion, may elect to send replacement goods to buyer prior to receipt of the defective goods. Buyer agrees to return defective goods with in 30 days or to pay for the replacement goods. M-511401 8/10 96d User Manual Honeywell 73 Warranty Buyer is responsible for transportation costs from the buyer’s location to HA. HA is responsible for transportation costs from HA’s location to the buyer. If in the case of a fixed installation or when it is not practical to return the product, the buyer should submit a claim to HA Service Department. A service engineer will attend on site on a day rate basis. Where a valid warranty claim is identified, the faulty product will be repaired or replaced free of charge. A warranty claim will be accepted if all conditions contained within this Warranty are met. When, in the opinion of HA, a warranty claim is valid, HA will repair or replace the defective product free of charge and send it or any replacement back to the buyer. If, in the opinion of HA the warranty claim is not valid, HA will, at the option of the buyer, return the unit unaltered at the buyer’s expense, repair the unit at the then prevailing rates, replace the unit with an appropriate replacement item at the then prevailing price, or discard the unit. HA reserves the right to charge for any attendance by its service engineer at the usual rates in force at the time the claim was received. In no event shall HA’s liability exceed the original purchase price paid by the buyer for the product. Consumer Claims If you purchased your HA product as a consumer, the above warranty conditions do not affect your rights under any applicable consumer protection legislation. Honeywell Analytics reserves the right to change this policy at any time. Contact Honeywell Analytics for the most current warranty information. 74 96d User Manual Honeyewell M-511401 8/10 Warranty M-511401 8/10 96d User Manual Honeywell 75 Find out more www.honeywellanalytics.com Contact Honeywell Analytics: Americas Honeywell Analytics Inc. 23500 W. 105th Street, MD 400 Olathe, KS 66061 Tel: +1 913 712 5576 Toll free: +1 800 444 9935 Toll free fax: +1 888 328 2417 detectgas@honeywell.com Europe, Middle East, Africa Life Safety Distribution AG Wilstrasse 11-U11 CH-8610 Uster Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (1) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050, Korea Tel: +82 (0)2 2025 0307 Fax: +82 (0)2 2025 0329 analytics.ap@honeywell.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards and guidelines. This publication is not intended to form the basis of a contract. Technical Services ha.global.service@honeywell.com www.honeywell.com M-511401, 08/10 © 2010 Honeywell Analytics
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : e487851 Create Date : 2010:08:12 08:49:17Z Modify Date : 2010:08:12 11:41:09-05:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Creator : e487851 Title : 96D.book Creator Tool : FrameMaker 9.0 Metadata Date : 2010:08:12 11:41:09-05:00 Producer : Acrobat Distiller 9.3.3 (Windows) Document ID : uuid:e088f536-6dea-4de4-85f0-c94ac18f9595 Instance ID : uuid:2488ad8c-7144-4c15-810a-d8211b38a41e Page Mode : UseOutlines Page Count : 80EXIF Metadata provided by EXIF.tools