Honeywell Thermostat L91B Users Manual 65 0059 L91 Proportionig Pressuretrol Controllers
L91F to the manual aeeab64d-c35b-49f0-a0b8-a2c5faf6dcb3
2015-01-23
: Honeywell Honeywell-Honeywell-Thermostat-L91B-Users-Manual-262136 honeywell-honeywell-thermostat-l91b-users-manual-262136 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Honeywell l Wiper on the controller potentiometer moves in response to pressure changes. l L91 PROPORTIONING PRESSURETROLCONTROLLERS L91 PROPORTIONING PRESSURETROL CONTROLLERS ARE SERIES 90 MODULATING PRESSURE CONTROLLERS THAT PROVIDE DIRECT CONTROL OF MODULATING MOTORS OR VALVES USED ON AUTOMATIC BURNERS OR STEAM HEATING SYSTEMS. 0 L91B 0 L91A 0 L91D 0 L91F Models available for pressure systems up to 300 psi [2066 kPa]. l These controllers may be used with steam, air, noncombustible gases, or other fluids noncorrosive to the brass or phosbronze (300 psi models) bellows. l I L91 D has 2 potentiometers for unison control of 2 motors. L91F has a fixed resistor and a manually-adjusted trim potentiometer in series with the controller potentiometer; for special applications in electronic bridge circuits. l LSlB,D, and F models have an adjustable proportioning (throttling) range to allow selection of desired pressure control range. l l Adjustments are made by screws on top of case. l Large, easily-read scaleplates are marked in both customary (or/in.*, psi, or in. Hg) and metric (kPa, MPa, or mm Hg) units. l Steel case has clear plastic cover so that pressure settings and potentiometer action can be observed. l Fitting with l/4-16 NPT threads provides rapid installation. Controller can also be surface mounted by screws through holes (knockouts) in back of case. l SPECIFICATIONS 1 TABLE I-MODELS AVAILABLE 0.03 to 1.03 MPa L91 Fa 0.09 to 0.36 MPa IO to 300 ps.0 0.07 to 2.07 MPa 23176CF Yes 30 to 110 psi 0.21 to 0.76 MPa 350 0 to 15 psi 0 to 103 kPa 9 Yes 1.5 to 12 psi 10 to 63 kPa 25 2413 172 5 to 150 psi 0.03 to 1.03 MPa 9 Yes 13 to 52 psi 0.09 to 0.36 MPa 225 1551 aScaleplates are marked in both customary (ozlin?, psi, or in. Hg) and Metric (kPa, MPa. or mm Hg) units. bModels available with or without steam trap (siphon loop). ‘Includes steam trap (siphon loop). dModel available with l/4 in. BSP-TR internal threads (British Standard Pipe Threads) for mounting. eL91F models have onefixed resistor and one manually-adjustable trim potentiometer in series with thecontroller potentiometer. Varidus combinations of resistance values and locations of the fixed resistor and trim potentiometer are available. See Table II. fLength of active winding is 7/64 in. [2.8 mm] for Part No. 23176CB, and l/4 in. [6.4 mm] for Part No. 23176CF. gSee Table II for potentiometer part number. D.A. 12-66* Form Number 65-0059 @Honeywell Inc. 1966 PROPcJRTlONlNG RANGE ADJUSTING SCREW (L91B.D.F.ONLY) MAIN SCALE ADJUSTING CONTROLLER POTENTIOMETER(S) IM P O T E N T I O M E T E R JUSTING SCREW POTENTIOMETER WIPER ARM(S) PROPORTIONING FINISH: Gray. MAIN SCALEPLATE: Marked in both customary (oz/in.*, psi, or in. Hg) and Metric (kPa. MPa. or mm Hg) units. PROPORTIONING RANGE SCALEPlATE (L919, D, and F only): graduated from A to F with a MIN (minimum) value below A. (See Table Ill for the value of each division.) MOUNTING MEANS: Fitting on bellows has l/4-18 NPT threads (external on 0 to 16 oz/in2, 0 to 4 psi, and 0 to 15 psi models; internal on all other models) for mounting on a pipe or steam trap (siphon loop). NOTE: Some models are available with l/4-19 BSP-TR internal threads: see Table I. Also can be surface mounted by screws through 2 holes (knockouts) in back of case. SCALEPLATE (L91B,D,F ONLY) PROPORTIONING TABLE II-L91 F RESISTANCE VALUES AVAILABLE INDICATOR (L91B.D.F ONLY) -BELLOWS HOUSING In Blega 11.2 23367F 3/16 4.8 In B lega 17.6 233676 3/16 4.8 380.0 23176- l/4 6.4 ln w legb I MAIN SCALE SETTING INDICATOR n 1 KNURLED ADJUSTMENT KNOB ON IO TO 300 PSI [0.07 TO 2.07 MPa, MODELS. El275 FIG. l- SETTING AN L91 PROPORTIONING PRESSURETROI CONTROLLER. MODELS: LSlA-single potentiometer; nonadjustable proportioning range. L91 B-single potentiometer; adjustable proportioning range. L91D-2 potentiometers allow unison control of 2 motors; adjustable proportioning range. L91 F-single potentiometer; adjustable proportioning range; fixed resistor and manually-adjustable trim potentiometer in series with controller potentiometer. ELECTRICAL RATING: 24 Vat. POTENTIOMETER ACTION: Wiper moves toward “w” on pressure rise; toward “6” on pressure fall. Potentiometer is field replaceable. POTENTIOMETER RESISTANCE: 140 ohms (nominal) for LSlA,B, and D models; see Table II for L91 F models. PRESSURE SENSING ELEMENT: Phos-bronze bellows. MAXIMUM AMBIENT TEMPERATURE: 150 F [66 C]. MINIMUM AMBIENT TEMPERATURE: 32 F [0 C]. ADJUSTMENT MEANS: Screws on top of controller case; knurled knob for main scale setting on 10 to 300 psi [0.07 to 2.07 MPa] models. SET POINT: At low pressure end of proportioning (throttling) range. WEIGHT: 116.15 oz. [0.88 kg]. 470 518 t2ohms, R-B 870 942+2ohms,R-B 2080 2515 f lOohms, aAvailable for Oto 15 psi [Ot 103 o kPa] models only. bAvailable for Oto 15 psi IOto 103 kPa] and 5to 150 psi [0.03 to 1.03 MPa] models. 'Nominal resistancevalues. eManually adjustable trim potentiometer is 100 ohms (nominal) in all L91F models. With zero pressure on the bellows, adjust the trim potentiometer to obtain the resistance values listed between terminals R and 8, or between terminals R and W, as indicated. TABLE III-APPROXIMATE VALUE OF EACH DIVISION (A TO 9, B TO C. etc.) ON PROPORTIONING (Throttling) RANGE SCALEPLATE (L919,D.F only) OPERATING RANGE I VALUE OF EACH DIVISION CUSTOMARY UNITS METRIC UNITS CUSTOMARY UNITS METRIC UNITS ~ 2 to 50 psi 14 to 345 kPa 4.7 psi 5 to 156 psi (L91B) 10.03 to 1.03 MPal 7.8 psi 1 0.054 MPa 5to 150 osi (LSlD,i) 10.03to 1.03 MPal 6.7 psi 1 0.046 MPa 10 to 300 psi 0.07 to 2.07 MPa (L918 with 7/64 in. pot.) 10 to 300 psi 0.07 to 2.07 MPa (LSlB,D with l/4 in. pot.) PRINTED IN U.S.A. 32.4 kPa 16.4 psi 0.113 MPa 13.8 psi 0.095 MPa
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Assemble, Print high-res XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Create Date : 1997:06:23 08:34:17Z Creator Tool : Acrobat 3.0 Capture Plug-in Modify Date : 2007:05:07 14:10:03-05:00 Metadata Date : 2007:05:07 14:10:03-05:00 Format : application/pdf Description : Specification Data Creator : H&BC Technical Communications Title : 65-0059 - L91 Proportionig Pressuretrol Controllers Producer : Acrobat 3.0 Import Plug-in Document ID : uuid:7466b400-c2c3-4f00-907d-c3d1a9be70d8 Instance ID : uuid:b39cf70a-c4b1-4bc8-ac13-6cf7f515e632 Page Count : 2 Subject : Specification Data Author : H&BC Technical CommunicationsEXIF Metadata provided by EXIF.tools