Honeywell Thermostat Series 2000 Users Manual 63 4356 Commercial Microelectronic

2015-01-23

: Honeywell Honeywell-Honeywell-Thermostat-Series-2000-Users-Manual-262193 honeywell-honeywell-thermostat-series-2000-users-manual-262193 honeywell pdf

Open the PDF directly: View PDF PDF.
Page Count: 20

DownloadHoneywell Honeywell-Honeywell-Thermostat-Series-2000-Users-Manual- 63-4356 - Series 2000 Commercial Microelectronic Thermostat  Honeywell-honeywell-thermostat-series-2000-users-manual
Open PDF In BrowserView PDF
Series 2000 Commercial
Microelectronic Thermostat
Contents
Features .................................................................. 3
Programming ........................................................... 4
Troubleshooting ...................................................... 18

® U.S. Registered Trademark
Copyright © 1996 Honeywell Inc. • All Rights Reserved

1

63-4356-1
63-4356—1

ENTER UNOCCUPIED
PROGRAM MODE
ENTER OCCUPIED
PROGRAM MODE

SET OCCUPIED
TEMPERATURE
SETPOINTS

SET CURRENT DAY OR
PROGRAM DAY

AM

Room

Mon
Occupied
System
Heat

RETURNS TO
NORMAL
OPERATIONS

Fan
Auto

Set Program

SET OVERRIDE
TEMPERATURE
OFFSET AND
ACTIVATE
TEMPORARY
OVERRIDE

ENTER HOLD MODE

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

INCREASE
TEMPERATURE
OR TIME SETTING

Heat/Cool
Settings

Continuous
Unoccupied

System

Fan

SELECT
SYSTEM
OPERATION

SET CURRENT
DAY AND TIME

COPY ONE
PROGRAMMED DAY
TO ANOTHER DAY

CLEAR PROGRAM PERIOD

63-4356—1

SET UNOCCUPIED
TEMPERATURE
SETPOINTS

2

DECREASE
TEMPERATURE
OR TIME SETTING

SELECT FAN
OPERATION

CHANGE BETWEEN
HEATING AND
COOLING SETPOINTS

M10256

FEATURES
• Program up to two Occupied and two Unoccupied time periods for each daily schedule.
• Set different schedules for each day of the week.
• Temporary temperature overrides.
• Program copy key.

3

63-4356—1

PROGRAMMING
key provides quick temporary temperature changes
for increased occupant comfort. The Continuous
Unoccupied key provides energy efficient operation
for extend periods of time.

The keyboard is located behind the thermostat
cover. Sixteen keys are used to set, review and
modify programmed times and temperature settings.
The thermostat display shows day, time, program
period and temperature.

Before starting the program procedure, use the
following chart to organize the program schedule.

The thermostat can be set for two Occupied and
two Unoccupied times for each day of the week
(28 independent time settings). Temporary Occupied

63-4356—1

4

Day

Occupied
Period 1

Unoccupied
Period 1

Occupied
Period 2

Unoccupied
Period 2

Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday

5

63-4356—1

The program has four temperature settings, Occupied
and Unoccupied heat and cool. The thermostat will
operate at the Unoccupied temperature setting
unless the thermostat is programmed. The following
chart shows the default temperature settings.
Occupied
Setpoint
Control

Default

Desired

í¢± Press Set Current Day/Time.
NOTE: On initial power up or after an
extended power loss, 1:00 pm flashes
on the LCD until a key is pressed.

Unoccupied
Setpoint
Default

Heating 70°F
(21°C)

55°F
(13°C)

Cooling 78°F
(25.5°C)

90°F
(32°C)

63-4356—1

Setting Current Day and Time

Set Day/Time

Set Current
Day/Time

Desired

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

PM

Change
Time/Temp

Mon

Heat/Cool
Settings

System

Fan

M4951B

6

í¢² Press Day until the current day is displayed.

í¢´ Press Run Program.
Run
Program

NOTE: Sun = Sunday, Mon = Monday, Tue =
Tuesday, Wed = Wednesday, Thu =
Thursday, Fri = Friday, Sat = Saturday.

AM
Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

System

Room

Change
Time/Temp

Mon
Occupied 1
System
Heat

Heat/Cool
Settings

Fan

Fan
Auto

M4954A
Set Day/Time

Day
Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

PM

Change
Time/Temp

Tue

Heat/Cool
Settings

System

Setting Program Times

Fan

M4952B

í¢± Press Occupied Start Time.

í¢³ Press increase â–² or decrease â–¼ key until the
current time is displayed.

NOTE: Anytime a start time is not required,
press the Clear Start Time.

NOTE: Tapping the Set Current Day/Time
will change the time in one hour
increments.

Set Program Start Time

Occupied
Start Time

AM
Set Program
Run
Program

Occupied
Start Time

Unoccupied
Start Time

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Continous
Unoccupied

Set Day/Time
Set Program
Run
Program

Occupied
Start Time

Unoccupied
Start Time

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Continous
Unoccupied

Set Temperature
Day

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

Copy

System

Set Temperature
Day

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

Copy

System

Change
Time/Temp

Mon
Occupied 1

Fan

M4955A

PM

Change
Time/Temp

Tue

Fan

M4953B

7

63-4356—1

í¢² Press Day until the desired day is displayed.

í¢´ Press Occupied Start Time a second time to
set a second Occupied Start Time.

Set ProgramStart Time

Day

AM
Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Wed
Occupied 1

Heat/Cool
Settings

System

Set ProgramStart Time

Occupied
Start Time

Change
Time/Temp

Fan

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

Wed
Occupied 2

Heat/Cool
Settings

System

Fan

M4956A

M4958B

í¢³ Press increase â–² or decrease â–¼ key until the
desired start time is displayed.

í¢µ Press increase â–² or decrease â–¼ key until the
desired start time is displayed.

NOTE: The program times are in fifteen
minute intervals. (Example: 8:00,
8:15, 8:30).

Set ProgramStart Time

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Wed
Occupied 2

Heat/Cool
Settings

System

PM

Change
Time/Temp

Fan

Set ProgramStart Time

M4959A
AM

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

Change
Time/Temp

Wed
Occupied 1

í¢¶ Press Unoccupied Start Time.

Fan

M4957A
Set Program Start Time

Unoccupied
Start Time

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

PM

Change
Time/Temp

Wed
UnOccupied 1

Fan

M4960A

63-4356—1

8

í¢· Press increase â–² or decrease â–¼ key until the
desired start time is displayed.

í¢¹ Press increase â–² or decrease â–¼ key until the
desired start time is displayed.
Set ProgramStart Time

Set ProgramStart Time
Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Set Program

Wed
UnOccupied 1

Heat/Cool
Settings

System

PM

Change
Time/Temp

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Occupied
Temp

System

PM
Wed
UnOccupied 2

Heat/Cool
Settings

Continous
Unoccupied

Fan

Unoccupied
Temp

Change
Time/Temp

Fan

M4963A

M4961A

í¢¸ Press Unoccupied Start Time a second time to
set a second Unoccupied Start Time.

Copying a Day
NOTE: The thermostat must be in the program
mode to use the copy feature. Go to step 2
if the thermostat is already in the program
mode.

Set Program Start Time

Unoccupied
Start Time

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

Change
Time/Temp

Wed
UnOccupied 2

Fan

M4962B

í¢± Press Occupied Start Time.
Set Program Start Time

Occupied
Start Time

AM
Set Program
Run
Program

Occupied
Start Time

Unoccupied
Start Time

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Continous
Unoccupied

Set Temperature
Day

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

Copy

System

Change
Time/Temp

Tue
Occupied 1

Fan

M10255

9

63-4356—1

í¢² Press Day to select the day to be copied if
different from the day displayed.

í¢´ Press Day until the day to be copied to is
displayed.

Set Program Start Time
AM

Day

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Wed
Occupied 1

Heat/Cool
Settings

System

Day

Change
Time/Temp

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Fan

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

Wed Thu

Heat/Cool
Settings

System

Fan

M4966A

M4968A

í¢³ Press Copy.
Copy

í¢µ Press Copy.

Set Program
Run
Program

Occupied
Start Time

Unoccupied
Start Time

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Continous
Unoccupied

Set Temperature
Day

Occupied
Temp

Unoccupied
Temp

NOTE: donE will be displayed for two
seconds and then the normal
program display will be shown.

Change
Time/Temp

Wed

Heat/Cool
Settings

Copy

System

Fan

M4967A

Copy

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

Heat/Cool
Settings

System

Fan

M4969A

63-4356—1

10

í¢± Press Occupied Temp.

í¢¶ Repeat steps í¢² through í¢µ for all the days
desired.

Setting

Set Program

Occupied
Temp

í¢· Press Run Program.

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Run
Program

AM
Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

Fan

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

Heat
Occupied

Heat/Cool
Settings

System

Fan

M4970B

Room

Change
Time/Temp

Mon
Occupied 1
System
Heat

Fan
Auto

í¢² Press increase â–² or decrease â–¼ key until the
desired temperature is displayed.

M4954A

Setting

Set Program
Set Program

Setting Program Temperature
Setpoints

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

Change
Time/Temp

Heat
Occupied

Fan

M4971B

NOTE: The setpoint temperature range is 40 to
90°F (7 to 31°C) for heating and 45 to 99°F
(9 to 37°C) for cooling.

11

63-4356—1

í¢³ Press Heat/Cool Settings to change between
heat and cool settings.

í¢µ Press Unoccupied Temp.
Set Program

Set Program

Heat/Cool
Settings

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Occupied
Temp

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Unoccupied
Temp

Heat
UnOccupied

Heat/Cool
Settings

Continous
Unoccupied

Cool

System

Setting

Change
Time/Temp

Change
Time/Temp
Fan

Occupied

Heat/Cool
Settings

System

Unoccupied
Temp

Setting

Fan

M4974B
M4972A

í¢¶ Press increase â–² or decrease â–¼ key until the
desired temperature is displayed.

í¢´ Press increase â–² or decrease â–¼ key until the
desired temperature is displayed.

Setting

Set Program
Set Program

Setting
Set Program

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

Continous
Unoccupied

System

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

Change
Time/Temp

Heat
UnOccupied

Fan

Occupied

Fan

M4975B
M4973B

63-4356—1

Occupied
Start Time

Continous
Unoccupied

Cool
Heat/Cool
Settings

Set Temperature

Run
Program

12

í¢· Press Heat/Cool Settings to change between
heat and cool settings.
Set Program

Heat/Cool
Settings

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

í¢± Press Occupied Start Time or Unoccupied
Start Time until the start time to be cleared is
displayed.

Setting

Change
Time/Temp

Cool

Heat/Cool
Settings

System

Clearing Program Start Times

UnOccupied

Fan

Set Program Start Time

Occupied
Start Time

M4976B

AM
Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

Mon
Occupied 1

Heat/Cool
Settings

System

Fan

í¢¸ Press increase â–² or decrease â–¼ key until the
desired temperature is displayed.
Set Program

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Occupied
Temp

Unoccupied
Temp

M4955A

í¢² Press Day until the desired day is displayed.

Setting

Change
Time/Temp

Cool
Continous
Unoccupied

Heat/Cool
Settings

System

UnOccupied

Set Program Start Time

Day

Fan

M4977B

AM
Set Program
Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

í¢¹ Press Run Program.
Run
Program

Set Temperature

Occupied
Start Time

Unoccupied
Start Time

Day

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

Fan

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

Change
Time/Temp

Mon
Occupied 1

Fan

M4978A

AM
Set Program
Run
Program

Temporary
Occupied

Set Temperature

Run
Program

Room

Change
Time/Temp

Mon
Occupied 1
System
Heat

Fan
Auto

M4954A

13

63-4356—1

í¢³ Press Clear Start Time.
Clear
Start Time

Temporary Occupied Override
Setting Temperature Offset
for Temporary Override

Set Program Start Time

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

Mon
Occupied 1

Heat/Cool
Settings

System

í¢± Press Occupied Temp.

Fan

M4979B
Setting

Occupied
Temp

í¢´ Repeat steps í¢± through í¢³ for all the start
times to be cleared.

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

Wed
Occupied

Heat/Cool
Settings

System

Heat

Fan

M10231

í¢µ Press Run Program.
Run
Program

í¢² Press Temporary Occupied.
AM
Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

Fan

Room

Change
Time/Temp

Mon
Occupied 1
System
Heat

Temporary
Occupied

Fan
Auto

M4954A

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

Heat/Cool
Settings

System

Fan

M4980A

63-4356—1

14

í¢³ Press increase â–² or decrease â–¼ key until the
desired temperature offset is displayed (range
is 0° to 5°F).
Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Using Temporary Override
í¢± Press Temporary Occupied.
NOTE: The default temperature setting is the
Occupied setpoint.

Change
Time/Temp

Heat/Cool
Settings

System

Fan

Setting

M4981A

Temporary
Occupied

í¢´ Press Run Program.

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

Change
Time/Temp

Override

Heat

Fan

M4982B

Run
Program

AM
Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

Fan

Room

Change
Time/Temp

Mon
Occupied 1
System
Heat

í¢² Press increase â–² or decrease â–¼ key to
change the default setting by the offset (range
is 0° to 5°F), if desired.

Fan
Auto

M4954A

15

63-4356—1

NOTE: If the offset is zero, the default
setting changes in one degree increments. If the offset is 1 through 5, the
default setting changes by plus or
minus the offset.

Using Continuous Unoccupied
í¢± Press Continuous Unoccupied.
NOTE: The default temperature setting is the
Unoccupied setpoint. The default
appears for five seconds and then the
display shows the room temperature.

Temporary
AM
Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Wed
Override

Heat/Cool
Settings

System

Room

Change
Time/Temp

System

Fan

Fan
Auto

Auto

Setting

Continuous
Unoccupied

M4983B

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

Heat
Continous
Unoccupied

Heat/Cool
Settings

System

Fan

í¢³ Press Run Program to cancel the override.
Run
Program

AM
Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

Fan

M4984B

Room

í¢² Press increase â–² or decrease â–¼ key to
change the default setting, if desired.

Change
Time/Temp

Mon
Occupied 1
System
Heat

Fan
Auto

M4954A
Setting

Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

Heat
Continous
Unoccupied

Heat/Cool
Settings

System

Fan

M10232A

63-4356—1

16

í¢³ Press Heat/Cool Setpoint to change between
heat and cool settings. Use increase â–² or
decrease â–¼ key to adjust temperature settings.

NOTE: If â–¼ or â–² appear under the temperature display, it means that both the
heating and cooling setpoints are being
adjusted. Tapping the key will change
both the heat and cool setpoints by
one degree. Press Heat/Cool Settings
after the desired setpoint is reached to
review the settings.

í¢´ Press Run Program again to cancel the Hold
and to return to the program.
Run
Program

AM
Set Program

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

System

Fan

Room

Change
Time/Temp

Mon
Occupied 1
System
Heat

Temporary Setting
Fan
Auto
Set Program

M4954A

Set Temperature

Run
Program

Occupied
Start Time

Unoccupied
Start Time

Day

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Copy

Continous
Unoccupied

Occupied
Temp

Unoccupied
Temp

Change
Time/Temp

Heat

Occupied

Heat/Cool
Settings

System

Fan

M4987B

Changing Temperature Setpoint Until
Next Program Period

í¢² Press Run Program to cancel the temporary
setpoint and to return to the program.

í¢± Press increase â–² or decrease â–¼ key until the
desired temperature is displayed.

Run
Program

AM
Set Program
Run
Program

Occupied
Start Time

Unoccupied
Start Time

Temporary
Occupied

Set Current
Day/Time

Clear
Start Time

Continous
Unoccupied

Set Temperature
Day

Occupied
Temp

Unoccupied
Temp

Heat/Cool
Settings

Copy

System

Fan

Room

Change
Time/Temp

Mon
Occupied 1
System
Heat

Fan
Auto

M4954A

17

63-4356—1

TROUBLESHOOTING GUIDE
Symptom

Action

Display will not come on.

• Check if the circuit breaker is tripped—reset the circuit breaker.
• Check if the fuse is blown—replace the fuse.
• Check if the system switch at the equipment is in the Off position—
set to the On position.
• Check wiring between thermostat and HVAC equipment—replace
any broken wires.
• If 24 Vac is present, proceed with troubleshooting.

Temperature settings will not
change (Example: cannot set
the heating higher or the
cooling lower).

• Check that the temperature setpoints are:
- heating: 40 to 90°F (7 to 31°C)
- cooling: 45 to 99°F (9 to 37°C).
• Keyboard is locked. Contact the installer.

Heating will not come on.

• Check if the circuit breaker is tripped—reset the circuit breaker.
• Check if the fuse is blown—replace the fuse.
• Check if the system switch at the equipment is in the Off position—
set to On position.
• If 24 Vac is present, proceed with troubleshooting.
• Wait five minutes for the system to respond.
• Set system selection to Heat.
(Continued)

63-4356—1

18

TROUBLESHOOTING GUIDE (Continued)
Symptom

Action

Cooling will not come on.

• Check if the circuit breaker is tripped—reset the circuit breaker.
• Check if the fuse is blown—replace the fuse.
• Check if the system switch at the equipment is in the Off position—
set to On position.
• If 24 Vac is present, proceed with troubleshooting.
• Wait five minutes for the system to respond.
• Set system selection to Cool.

System on indicator
(flame=heat, snowflake=cool)
is displayed, but no warm or
cool air is coming from the
registers.

Wait a minute after seeing the flame or snowflake and then check the
registers.

19

63-4356—1

Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422-4386

63-4356—1
63-4356—1J.H. Rev. 12-96

Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario M1V 4Z9

20

20

www.honeywell.com/buliding/components



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Encryption                      : Standard V4.4 (128-bit)
User Access                     : Print, Copy, Extract, Assemble, Print high-res
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 5.00 for Macintosh
Keywords                        : 
Create Date                     : 2004:08:31 20:27:44Z
Modify Date                     : 2007:05:07 14:00:22-05:00
Metadata Date                   : 2007:05:07 14:00:22-05:00
Creator Tool                    : Adobe PageMaker 6.5
Format                          : application/pdf
Creator                         : Honeywell Technical Communications
Description                     : Owner's Guide
Title                           : 63-4356 - Series 2000 Commercial Microelectronic Thermostat
Document ID                     : uuid:d381903e-398e-4b4c-9584-00234f89ff31
Instance ID                     : uuid:d60b069f-ebca-46d5-b1b3-03b41bb16bf2
Page Count                      : 20
Subject                         : Owner's Guide
Author                          : Honeywell Technical Communications
EXIF Metadata provided by EXIF.tools

Navigation menu