Honeywell Thermostat Series 2000 Users Manual 63 4356 Commercial Microelectronic
2015-01-23
: Honeywell Honeywell-Honeywell-Thermostat-Series-2000-Users-Manual-262193 honeywell-honeywell-thermostat-series-2000-users-manual-262193 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 20
Download | |
Open PDF In Browser | View PDF |
Series 2000 Commercial Microelectronic Thermostat Contents Features .................................................................. 3 Programming ........................................................... 4 Troubleshooting ...................................................... 18 ® U.S. Registered Trademark Copyright © 1996 Honeywell Inc. • All Rights Reserved 1 63-4356-1 63-4356—1 ENTER UNOCCUPIED PROGRAM MODE ENTER OCCUPIED PROGRAM MODE SET OCCUPIED TEMPERATURE SETPOINTS SET CURRENT DAY OR PROGRAM DAY AM Room Mon Occupied System Heat RETURNS TO NORMAL OPERATIONS Fan Auto Set Program SET OVERRIDE TEMPERATURE OFFSET AND ACTIVATE TEMPORARY OVERRIDE ENTER HOLD MODE Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Occupied Temp Unoccupied Temp Change Time/Temp INCREASE TEMPERATURE OR TIME SETTING Heat/Cool Settings Continuous Unoccupied System Fan SELECT SYSTEM OPERATION SET CURRENT DAY AND TIME COPY ONE PROGRAMMED DAY TO ANOTHER DAY CLEAR PROGRAM PERIOD 63-4356—1 SET UNOCCUPIED TEMPERATURE SETPOINTS 2 DECREASE TEMPERATURE OR TIME SETTING SELECT FAN OPERATION CHANGE BETWEEN HEATING AND COOLING SETPOINTS M10256 FEATURES • Program up to two Occupied and two Unoccupied time periods for each daily schedule. • Set different schedules for each day of the week. • Temporary temperature overrides. • Program copy key. 3 63-4356—1 PROGRAMMING key provides quick temporary temperature changes for increased occupant comfort. The Continuous Unoccupied key provides energy efficient operation for extend periods of time. The keyboard is located behind the thermostat cover. Sixteen keys are used to set, review and modify programmed times and temperature settings. The thermostat display shows day, time, program period and temperature. Before starting the program procedure, use the following chart to organize the program schedule. The thermostat can be set for two Occupied and two Unoccupied times for each day of the week (28 independent time settings). Temporary Occupied 63-4356—1 4 Day Occupied Period 1 Unoccupied Period 1 Occupied Period 2 Unoccupied Period 2 Monday Tuesday Wednesday Thursday Friday Saturday Sunday 5 63-4356—1 The program has four temperature settings, Occupied and Unoccupied heat and cool. The thermostat will operate at the Unoccupied temperature setting unless the thermostat is programmed. The following chart shows the default temperature settings. Occupied Setpoint Control Default Desired í¢± Press Set Current Day/Time. NOTE: On initial power up or after an extended power loss, 1:00 pm flashes on the LCD until a key is pressed. Unoccupied Setpoint Default Heating 70°F (21°C) 55°F (13°C) Cooling 78°F (25.5°C) 90°F (32°C) 63-4356—1 Setting Current Day and Time Set Day/Time Set Current Day/Time Desired Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp PM Change Time/Temp Mon Heat/Cool Settings System Fan M4951B 6 í¢² Press Day until the current day is displayed. í¢´ Press Run Program. Run Program NOTE: Sun = Sunday, Mon = Monday, Tue = Tuesday, Wed = Wednesday, Thu = Thursday, Fri = Friday, Sat = Saturday. AM Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp System Room Change Time/Temp Mon Occupied 1 System Heat Heat/Cool Settings Fan Fan Auto M4954A Set Day/Time Day Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp PM Change Time/Temp Tue Heat/Cool Settings System Setting Program Times Fan M4952B í¢± Press Occupied Start Time. í¢³ Press increase â–² or decrease â–¼ key until the current time is displayed. NOTE: Anytime a start time is not required, press the Clear Start Time. NOTE: Tapping the Set Current Day/Time will change the time in one hour increments. Set Program Start Time Occupied Start Time AM Set Program Run Program Occupied Start Time Unoccupied Start Time Temporary Occupied Set Current Day/Time Clear Start Time Continous Unoccupied Set Day/Time Set Program Run Program Occupied Start Time Unoccupied Start Time Temporary Occupied Set Current Day/Time Clear Start Time Continous Unoccupied Set Temperature Day Occupied Temp Unoccupied Temp Heat/Cool Settings Copy System Set Temperature Day Occupied Temp Unoccupied Temp Heat/Cool Settings Copy System Change Time/Temp Mon Occupied 1 Fan M4955A PM Change Time/Temp Tue Fan M4953B 7 63-4356—1 í¢² Press Day until the desired day is displayed. í¢´ Press Occupied Start Time a second time to set a second Occupied Start Time. Set ProgramStart Time Day AM Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Wed Occupied 1 Heat/Cool Settings System Set ProgramStart Time Occupied Start Time Change Time/Temp Fan Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Change Time/Temp Wed Occupied 2 Heat/Cool Settings System Fan M4956A M4958B í¢³ Press increase â–² or decrease â–¼ key until the desired start time is displayed. í¢µ Press increase â–² or decrease â–¼ key until the desired start time is displayed. NOTE: The program times are in fifteen minute intervals. (Example: 8:00, 8:15, 8:30). Set ProgramStart Time Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Wed Occupied 2 Heat/Cool Settings System PM Change Time/Temp Fan Set ProgramStart Time M4959A AM Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Heat/Cool Settings System Change Time/Temp Wed Occupied 1 í¢¶ Press Unoccupied Start Time. Fan M4957A Set Program Start Time Unoccupied Start Time Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Heat/Cool Settings System PM Change Time/Temp Wed UnOccupied 1 Fan M4960A 63-4356—1 8 í¢· Press increase â–² or decrease â–¼ key until the desired start time is displayed. í¢¹ Press increase â–² or decrease â–¼ key until the desired start time is displayed. Set ProgramStart Time Set ProgramStart Time Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Set Program Wed UnOccupied 1 Heat/Cool Settings System PM Change Time/Temp Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Occupied Temp System PM Wed UnOccupied 2 Heat/Cool Settings Continous Unoccupied Fan Unoccupied Temp Change Time/Temp Fan M4963A M4961A í¢¸ Press Unoccupied Start Time a second time to set a second Unoccupied Start Time. Copying a Day NOTE: The thermostat must be in the program mode to use the copy feature. Go to step 2 if the thermostat is already in the program mode. Set Program Start Time Unoccupied Start Time Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Heat/Cool Settings System Change Time/Temp Wed UnOccupied 2 Fan M4962B í¢± Press Occupied Start Time. Set Program Start Time Occupied Start Time AM Set Program Run Program Occupied Start Time Unoccupied Start Time Temporary Occupied Set Current Day/Time Clear Start Time Continous Unoccupied Set Temperature Day Occupied Temp Unoccupied Temp Heat/Cool Settings Copy System Change Time/Temp Tue Occupied 1 Fan M10255 9 63-4356—1 í¢² Press Day to select the day to be copied if different from the day displayed. í¢´ Press Day until the day to be copied to is displayed. Set Program Start Time AM Day Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Wed Occupied 1 Heat/Cool Settings System Day Change Time/Temp Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Fan Occupied Temp Unoccupied Temp Change Time/Temp Wed Thu Heat/Cool Settings System Fan M4966A M4968A í¢³ Press Copy. Copy í¢µ Press Copy. Set Program Run Program Occupied Start Time Unoccupied Start Time Temporary Occupied Set Current Day/Time Clear Start Time Continous Unoccupied Set Temperature Day Occupied Temp Unoccupied Temp NOTE: donE will be displayed for two seconds and then the normal program display will be shown. Change Time/Temp Wed Heat/Cool Settings Copy System Fan M4967A Copy Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Change Time/Temp Heat/Cool Settings System Fan M4969A 63-4356—1 10 í¢± Press Occupied Temp. í¢¶ Repeat steps í¢² through í¢µ for all the days desired. Setting Set Program Occupied Temp í¢· Press Run Program. Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Run Program AM Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Heat/Cool Settings System Fan Occupied Temp Unoccupied Temp Change Time/Temp Heat Occupied Heat/Cool Settings System Fan M4970B Room Change Time/Temp Mon Occupied 1 System Heat Fan Auto í¢² Press increase â–² or decrease â–¼ key until the desired temperature is displayed. M4954A Setting Set Program Set Program Setting Program Temperature Setpoints Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Heat/Cool Settings System Change Time/Temp Heat Occupied Fan M4971B NOTE: The setpoint temperature range is 40 to 90°F (7 to 31°C) for heating and 45 to 99°F (9 to 37°C) for cooling. 11 63-4356—1 í¢³ Press Heat/Cool Settings to change between heat and cool settings. í¢µ Press Unoccupied Temp. Set Program Set Program Heat/Cool Settings Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Occupied Temp Temporary Occupied Set Current Day/Time Clear Start Time Copy Unoccupied Temp Heat UnOccupied Heat/Cool Settings Continous Unoccupied Cool System Setting Change Time/Temp Change Time/Temp Fan Occupied Heat/Cool Settings System Unoccupied Temp Setting Fan M4974B M4972A í¢¶ Press increase â–² or decrease â–¼ key until the desired temperature is displayed. í¢´ Press increase â–² or decrease â–¼ key until the desired temperature is displayed. Setting Set Program Set Program Setting Set Program Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Occupied Temp Unoccupied Temp Change Time/Temp Continous Unoccupied System Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Occupied Temp Unoccupied Temp Heat/Cool Settings System Change Time/Temp Heat UnOccupied Fan Occupied Fan M4975B M4973B 63-4356—1 Occupied Start Time Continous Unoccupied Cool Heat/Cool Settings Set Temperature Run Program 12 í¢· Press Heat/Cool Settings to change between heat and cool settings. Set Program Heat/Cool Settings Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp í¢± Press Occupied Start Time or Unoccupied Start Time until the start time to be cleared is displayed. Setting Change Time/Temp Cool Heat/Cool Settings System Clearing Program Start Times UnOccupied Fan Set Program Start Time Occupied Start Time M4976B AM Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Change Time/Temp Mon Occupied 1 Heat/Cool Settings System Fan í¢¸ Press increase â–² or decrease â–¼ key until the desired temperature is displayed. Set Program Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Occupied Temp Unoccupied Temp M4955A í¢² Press Day until the desired day is displayed. Setting Change Time/Temp Cool Continous Unoccupied Heat/Cool Settings System UnOccupied Set Program Start Time Day Fan M4977B AM Set Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied í¢¹ Press Run Program. Run Program Set Temperature Occupied Start Time Unoccupied Start Time Day Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Heat/Cool Settings System Fan Occupied Temp Unoccupied Temp Heat/Cool Settings System Change Time/Temp Mon Occupied 1 Fan M4978A AM Set Program Run Program Temporary Occupied Set Temperature Run Program Room Change Time/Temp Mon Occupied 1 System Heat Fan Auto M4954A 13 63-4356—1 í¢³ Press Clear Start Time. Clear Start Time Temporary Occupied Override Setting Temperature Offset for Temporary Override Set Program Start Time Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Change Time/Temp Mon Occupied 1 Heat/Cool Settings System í¢± Press Occupied Temp. Fan M4979B Setting Occupied Temp í¢´ Repeat steps í¢± through í¢³ for all the start times to be cleared. Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Change Time/Temp Wed Occupied Heat/Cool Settings System Heat Fan M10231 í¢µ Press Run Program. Run Program í¢² Press Temporary Occupied. AM Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Heat/Cool Settings System Fan Room Change Time/Temp Mon Occupied 1 System Heat Temporary Occupied Fan Auto M4954A Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Change Time/Temp Heat/Cool Settings System Fan M4980A 63-4356—1 14 í¢³ Press increase â–² or decrease â–¼ key until the desired temperature offset is displayed (range is 0° to 5°F). Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Using Temporary Override í¢± Press Temporary Occupied. NOTE: The default temperature setting is the Occupied setpoint. Change Time/Temp Heat/Cool Settings System Fan Setting M4981A Temporary Occupied í¢´ Press Run Program. Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Heat/Cool Settings System Change Time/Temp Override Heat Fan M4982B Run Program AM Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Heat/Cool Settings System Fan Room Change Time/Temp Mon Occupied 1 System Heat í¢² Press increase â–² or decrease â–¼ key to change the default setting by the offset (range is 0° to 5°F), if desired. Fan Auto M4954A 15 63-4356—1 NOTE: If the offset is zero, the default setting changes in one degree increments. If the offset is 1 through 5, the default setting changes by plus or minus the offset. Using Continuous Unoccupied í¢± Press Continuous Unoccupied. NOTE: The default temperature setting is the Unoccupied setpoint. The default appears for five seconds and then the display shows the room temperature. Temporary AM Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Wed Override Heat/Cool Settings System Room Change Time/Temp System Fan Fan Auto Auto Setting Continuous Unoccupied M4983B Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Occupied Temp Unoccupied Temp Change Time/Temp Heat Continous Unoccupied Heat/Cool Settings System Fan í¢³ Press Run Program to cancel the override. Run Program AM Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Heat/Cool Settings System Fan M4984B Room í¢² Press increase â–² or decrease â–¼ key to change the default setting, if desired. Change Time/Temp Mon Occupied 1 System Heat Fan Auto M4954A Setting Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Occupied Temp Unoccupied Temp Change Time/Temp Heat Continous Unoccupied Heat/Cool Settings System Fan M10232A 63-4356—1 16 í¢³ Press Heat/Cool Setpoint to change between heat and cool settings. Use increase â–² or decrease â–¼ key to adjust temperature settings. NOTE: If â–¼ or â–² appear under the temperature display, it means that both the heating and cooling setpoints are being adjusted. Tapping the key will change both the heat and cool setpoints by one degree. Press Heat/Cool Settings after the desired setpoint is reached to review the settings. í¢´ Press Run Program again to cancel the Hold and to return to the program. Run Program AM Set Program Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Heat/Cool Settings System Fan Room Change Time/Temp Mon Occupied 1 System Heat Temporary Setting Fan Auto Set Program M4954A Set Temperature Run Program Occupied Start Time Unoccupied Start Time Day Temporary Occupied Set Current Day/Time Clear Start Time Copy Continous Unoccupied Occupied Temp Unoccupied Temp Change Time/Temp Heat Occupied Heat/Cool Settings System Fan M4987B Changing Temperature Setpoint Until Next Program Period í¢² Press Run Program to cancel the temporary setpoint and to return to the program. í¢± Press increase â–² or decrease â–¼ key until the desired temperature is displayed. Run Program AM Set Program Run Program Occupied Start Time Unoccupied Start Time Temporary Occupied Set Current Day/Time Clear Start Time Continous Unoccupied Set Temperature Day Occupied Temp Unoccupied Temp Heat/Cool Settings Copy System Fan Room Change Time/Temp Mon Occupied 1 System Heat Fan Auto M4954A 17 63-4356—1 TROUBLESHOOTING GUIDE Symptom Action Display will not come on. • Check if the circuit breaker is tripped—reset the circuit breaker. • Check if the fuse is blown—replace the fuse. • Check if the system switch at the equipment is in the Off position— set to the On position. • Check wiring between thermostat and HVAC equipment—replace any broken wires. • If 24 Vac is present, proceed with troubleshooting. Temperature settings will not change (Example: cannot set the heating higher or the cooling lower). • Check that the temperature setpoints are: - heating: 40 to 90°F (7 to 31°C) - cooling: 45 to 99°F (9 to 37°C). • Keyboard is locked. Contact the installer. Heating will not come on. • Check if the circuit breaker is tripped—reset the circuit breaker. • Check if the fuse is blown—replace the fuse. • Check if the system switch at the equipment is in the Off position— set to On position. • If 24 Vac is present, proceed with troubleshooting. • Wait five minutes for the system to respond. • Set system selection to Heat. (Continued) 63-4356—1 18 TROUBLESHOOTING GUIDE (Continued) Symptom Action Cooling will not come on. • Check if the circuit breaker is tripped—reset the circuit breaker. • Check if the fuse is blown—replace the fuse. • Check if the system switch at the equipment is in the Off position— set to On position. • If 24 Vac is present, proceed with troubleshooting. • Wait five minutes for the system to respond. • Set system selection to Cool. System on indicator (flame=heat, snowflake=cool) is displayed, but no warm or cool air is coming from the registers. Wait a minute after seeing the flame or snowflake and then check the registers. 19 63-4356—1 Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422-4386 63-4356—1 63-4356—1J.H. Rev. 12-96 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 20 20 www.honeywell.com/buliding/components
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Assemble, Print high-res XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 5.00 for Macintosh Keywords : Create Date : 2004:08:31 20:27:44Z Modify Date : 2007:05:07 14:00:22-05:00 Metadata Date : 2007:05:07 14:00:22-05:00 Creator Tool : Adobe PageMaker 6.5 Format : application/pdf Creator : Honeywell Technical Communications Description : Owner's Guide Title : 63-4356 - Series 2000 Commercial Microelectronic Thermostat Document ID : uuid:d381903e-398e-4b4c-9584-00234f89ff31 Instance ID : uuid:d60b069f-ebca-46d5-b1b3-03b41bb16bf2 Page Count : 20 Subject : Owner's Guide Author : Honeywell Technical CommunicationsEXIF Metadata provided by EXIF.tools