Honeywell Thermostat T451A Users Manual 63 2051 T451A, T651A, T694A,B,D,F Light Duty Line Voltage Thermostats
2015-01-23
: Honeywell Honeywell-Honeywell-Thermostat-T451A-Users-Manual-262210 honeywell-honeywell-thermostat-t451a-users-manual-262210 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
T451A, T651A, T694A,B,D,F Light Duty Line Voltage Thermostats T451, T651, T694 Thermostats provide on-off control of valves, fans, motors, contactors, electric heat elements, duct furnaces and fan coil units in heating/cooling systems. Switching subbases provide manual control of heating, cooling and fan. T451A, T651A T694B,D,F T694A ■ T451A provides heating control only. ■ Thermostats use spst or spdt snap switches activated by bimetal sensor. ■ T651A provides heating and cooling control. ■ T694A,B,D,F supplied with switching subbase to provide manual control of heating, cooling and fan. ■ Q473A,B switching subbase available for T451A/ T651A. ■ T451A/T651A mount on standard vertical or horizontal junction box. ■ Options include adjustable range stops, locking cover, concealed setpoint, locking setpoint, positive off control, cover thermometer. ■ Automatic cooling anticipator for 120, 208, 240 and 277 Vac. CONTENTS Specifications ................................................. 2 Ordering Information ..................................... 2 Installation ..................................................... 4 Checkout ......................................................... 7 J. H. • Rev. 9-92 1 • ©Honeywell Inc. 1992 • Form Number 63-2051—4 T451A, T651A, T694A,B,D,F SPECIFICATIONS • ORDERING INFORMATION Specifications — Automatic cooling anticipator for 120, 208, 240 and 277 Vac. — Vertical faceplate with Fahrenheit scale and thermometer. — Horizontal faceplate with Fahrenheit scale and thermometer. — Blank vertical faceplate. — Blank horizontal faceplate. — Wallplate. — Adjustable range stops. — Locking cover screw. SUPER TRADELINE MODEL TRADELINE models are selected and packaged to provide ease of stocking, ease of handling and maximum replacement value. TRADELINE model specifications are the same as those of standard models except as noted below. SUPER TRADELINE MODEL AVAILABLE: T651A2028 Light Duty Line Voltage Thermostat. FEATURES: — Temperature scale range 35° F to 95° F. — Spdt switch breaks heating contacts and makes cooling contacts on temperature rise. STANDARD MODELS: Model Number T451A2007a T451A2015 T651A2028a T694A2002 T694B2001 T694D2009 T694F2007 a Application Heating only. Heating only with positive OFF. Heating/cooling. Heating/cooling. OFF position breaks fan circuit. Heating/cooling. OFF position breaks cooling and fan circuits. Heating/cooling. Heating circuits isolated from cooling circuits. OFF position breaks all control circuits except heat. Heating/cooling. Heating circuits isolated from cooling circuits. OFF position breaks all power to fan and thermostat. System Switch — — — ON-OFF Changeover Switch — — — — Fan Switch — — — HI-MEDIUM-LO ON-OFF HEAT-COOL HI-MEDIUM-LO ON-OFF HEAT-COOL HI-MEDIUM-LO ON-OFF HEAT-COOL HI-MEDIUM-LO With thermometer. Ordering Information When purchasing replacement and modernization products from your TRADELINE® wholesaler or your distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number, or specify— 1. Order number. 2. Accessories, if desired. 3. Order additional components and system accessories separately. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Home and Building Control Sales Office (check white pages of your phone directory). 2. Home and Building Control Customer Satisfaction Honeywell Inc., 1885 Douglas Drive North Golden Valley, MN 55422-4386 (612) 951-1000 In Canada—Honeywell Limited/Honeywell Limitee, 740 Ellesmere Road, Scarborough, Ontario M1P 2V9, International Sales and Service offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 2 T451A, T651A, T694A,B,D,F SPECIFICATIONS ELECTRICAL RATINGS (A): 120 8 48 Full Load Locked Rotor a FINISH: Brushed champagne gold and dark pewter faceplate; beige and brown case. Voltage (Vac) 208/240/277 4a 24 UNDERWRITERS LABORATORIES INC.: Listed. ACCESSORIES: Q473A2006 Switching Subbase: Use with T651A for HEAT-OFF-COOL manual system switching. Q473B2005 Switching Subbase: Use with T451A/ T652A for AUTO/OFF switching in heating only or cooling only applications. 220124A Faceplate vertical, Fahrenheit scale, with thermometer.a 220124B Faceplate vertical, Celsius scale, with thermometer. 220124C Faceplate, horizontal, Fahrenheit scale, with thermometer.a 220124D Faceplate, horizontal, Celsius scale, with thermometer. 220125A Faceplate, horizontal, Fahrenheit scale, without thermometer. 220125B Faceplate, vertical, Fahrenheit scale, without thermometer. 220125C Faceplate, horizontal, Celsius scale, without thermometer. 220125D Faceplate, vertical, Celsius scale, without thermometer. 220126A Faceplate, horizontal, blank (concealed setpoint, without thermometer).a 220126B Faceplate, vertical, blank (concealed setpoint, without thermometer).a 220213 Wallplate, covers old T451A/T651A wall marks when installing new T451A/T651A.a 199242 Wallplate, covers old T694 wall marks when installing new T694. Wider temperature differential ranges can occur when used in cooling applications with current draws that are more than four amps. If a wider differential range is unacceptable, use a T6051 Heavy Duty Line Voltage Thermostat for a smaller differential range. Pilot Duty: 125 VA. 7.2A Resistive: heating contacts only. TEMPERATURE SETTING RANGE: 35° F to 95° F [2° C to 35° C] (with range stops removed). STORAGE TEMPERATURE: -40° F to 150° F [-40° C to 66° C]. FIXED DIFFERENTIAL: 2° F [1° C]. SWITCHING ACTION: T451: Spst. Contacts make on temperature fall. T651: Spdt. Heating contacts break and cooling contacts make on temperature rise. T694: Spdt. Heating contacts break and cooling contacts make on temperature rise. FIELD WIRING CONNECTIONS: No. 10 screw terminals on T451A/T651A; color-coded leads on T694 models. DIMENSIONS: See Figs. 1 and 2. a Supplied with SUPER TRADELINE model T651A. Fig. 1—T451A, T651A mounting dimensions in in. [mm]. 15 1 32 [35] 9 16 [14] 70 60 50 80 40 90 417 32 [114] 3 4 [45] 1 F 40 50 60 70 80 90 2 13 16 [70] 11 8 [22] 15 16 [24] 113 16 [48] 9 3 32 [83] COOL HEAT COM 1 8 [37] 1 17 32 [14] M6130 3 63-2051—4 T451A, T651A, T694A,B,D,F INSTALLATION Fig. 2—T694A,B,D,F mounting dimensions in in. [mm]. 1 7 8 [48] SYSTEM ON 70 60 50 80 40 OFF 90 HEAT COOL F FAN 47 8 [124] 3 9 32 [83] 3 [76] HI MED LOW 4 29 32 [125 ] 15 32 [35] 1 9 16 [40] (T694B SHOWN) 1 13 32 [36] M6129 Installation Do not use on electric heat. Possible fire hazard if T694A,B,D used on electric heat. T694F can be used on electric heat. Do not install the thermostat where it may be affected by: • drafts, or dead spots behind doors and in corners. • hot or cold air from ducts. • radiant heat from sun or appliances. • concealed pipes and chimneys. • unheated (uncooled) areas behind the thermostat, such as an outside wall. WHEN INSTALLING THIS PRODUCT… 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. WIRING AND MOUNTING Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. All wiring must comply with applicable electrical codes, ordinances and regulations. Use copper wire only. Make sure that thermostat electrical rating is sufficient for current requirements of controlled equipment, and that listed voltage matches power supply. ! ! WARNING T451A/T651A THERMOSTATS (Fig. 3) T451A/T651A Thermostats mount vertically on a 2 x 4 in. or 4 x 4 in. junction box. See Fig. 3. Use 2 x 4 in. cover plate with 4 x 4 in. junction. For horizontal mounting, the appropriate horizontal faceplate is required. Horizontal with thermometer and horizontal blank faceplates are packaged with the T651A2028 SUPER TRADELINE model. For additional faceplates or T451 applications, see Accessories. When replacing old style T451A/T651A, use a wallplate to cover previous wall marks. This wallplate is packaged with the T651A2028 SUPER TRADELINE model. For T451 applications, see Accessories. CAUTION Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. Use copper wire only. LOCATION Select the same location as control to be replaced, or select a new location about 5 ft. [1.5 m] above the floor, on an inside wall where there is good air circulation at average room temperature. 4 T451A, T651A, T694A,B,D,F INSTALLATION 1. Before mounting thermostat, connect system wiring to proper terminals at rear of thermostat. Follow equipment manufacturer instructions or refer to Fig. 4 for typical system hookup. 2. Remove cover assembly from thermostat. Attach thermostat to junction box with two screws provided. Replace cover assembly. See Fig. 3. 3. Use 1/16 hex Allen wrench to install Allen locking cover screw. 2. Remove thermostat cover assembly. Attach thermostat to junction box with two screws provided. Replace thermostat cover assembly. Fig. 4—T652A in heating-cooling system. Fig. 3—Mounting T451A/T651A. 220213 WALLPLATE ACCESSORY (OPTIONAL) (COVERS OLD T651A WALL MARKS WHEN INSTALLING NEW T651A) Fig. 5—Mounting T694A,B,D,F. TABS HOLD COVER ASSEMBLY AT TOP (SNAP IN AT BOTTOM) MOUNTING SCREWS (2) 70 60 USE 2x4 JUNCTION BOX COVER PLATE 4x4 JUNCTION BOX 80 90 TABS HOLD COVER ASSEMBLY AT TOP (SNAP IN AT BOTTOM) 50 40 F 40 50 60 70 80 90 EM ST SY ON MOUNTING SCREWS (2) F OF AT HE OL CO N FA M6131 HI D ME W LO USE 2x4 OR 4x4 JUNCTION BOX 70 60 T694A,B,D,F THERMOSTATS (Fig. 5) All T694A,B,D,F Thermostats mount vertically on a 2 x 4 in. or 4 x 4 in. junction box. See Fig. 5. Use 2 x 4 in. cover plate with 4 x 4 in. junction box. 1. Before mounting, connect system wiring to proper color-coded leads at rear of thermostat. Follow equipment manufacturer instructions or refer to Figs. 6-9 for typical system hookups. 80 90 50 40 F (T694B SHOWN) M6135 5 63-2051—4 T451A, T651A, T694A,B,D,F INSTALLATION Fig. 6—T694A in heating-cooling system with independent valve and fan circuits. Fig. 8—T694D with isolated switching for heating and cooling. Fig. 7—T694B connected for positive-off switching in COOL position. Fig. 9—T694F with positive-off position. 6 T451A, T651A, T694A,B,D,F CHECKOUT Checkout After the thermostat is wired and mounted, perform the following system checkout procedure. T694 NOTE: System switch must be in ON position to check out system. T451/T651 IN HEATING APPLICATION: 1. Close disconnect switch (if used). 2. Adjust setpoint above room temperature and check that heating system turns on. 3. Adjust setpoint below room temperature and check that heating system turns off. 4. Adjust thermostat for desired room temperature. 1. Close the disconnect switch (if used) and press HEAT switch; adjust setpoint above room temperature and check that heating system turns on. 2. Adjust setpoint below room temperature and check that heating system turns off. 3. Press COOL switch; adjust setpoint below room temperature. Check that cooling system turns on and fan runs continuously. 4. Press fan LO, MED, HI switches and check that fan control operates properly. 5. Adjust setpoint above room temperature and check that cooling system turns off. Fan operates continuously. 6. Adjust thermostat for desired room temperature. IN COOLING APPLICATION: 1. Close disconnect switch (if used). 2. Adjust setpoint below room temperature and check that cooling system turns on. 3. Adjust setpoint above from temperature and check that cooling system turns off. 4. Adjust thermostat for desired room temperature. If questions arise regarding this product, contact your distributor or local Honeywell representative. NOTE: Wider temperature differential ranges can occur when used in cooling applications with current draws that are more than four amps. If a wider differential range is unacceptable, use a T6051 Heavy Duty Line Voltage Thermostat for a smaller differential range. 7 63-2051—4 Home and Building Control Honeywell Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Printed in U.S.A. Home and Building Control Honeywell Limited—Honeywell Limitée 740 Ellesmere Road Scarborough, Ontario M1P 2V9 8 Helping You Control Your World QUALITY IS KEY
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Fill forms, Extract, Assemble, Print high-res XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Producer : Acrobat Distiller 5.00 for Macintosh Keywords : Create Date : 2002:04:26 18:08:01Z Modify Date : 2009:02:26 09:15:42-06:00 Metadata Date : 2009:02:26 09:15:42-06:00 Creator Tool : Adobe PageMaker 6.5 Format : application/pdf Creator : Honeywell ACS Technical Communications Description : Product Data Title : 63-2051 - T451A, T651A, T694A,B,D,F Light Duty Line Voltage Thermostats Document ID : uuid:d0ecbbcd-4845-4529-86e0-ca7053774bf7 Instance ID : uuid:6fef57b9-6433-4e68-b046-6017ec47fae0 Page Count : 8 Subject : Product Data Author : Honeywell ACS Technical CommunicationsEXIF Metadata provided by EXIF.tools