Honeywell Universal Remote Dc300K E Users Manual
Honeywell Universal Remote DC300K-E UDC3000 Versa-Pro Universal Digital Controller Specification
2015-01-23
: Honeywell Honeywell-Honeywell-Universal-Remote-Dc300K-E-Users-Manual-262605 honeywell-honeywell-universal-remote-dc300k-e-users-manual-262605 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 12
Download | |
Open PDF In Browser | View PDF |
UDC3000 Versa-Pro Universal Digital Controller Overview The UDC3000 Universal Digital Controller is Honeywell’s general purpose microprocessor-based, stand alone digital controller. It combines the highest degree of functionality and operating simplicity offered in a 1/4 DIN size. The bright dual displays with multilanguage prompts make the operator interface easy to read, understand, and operate. Programmed sequences of displays assure quick and accurate entry of all configurable parameters. Simple keystrokes let you select input and range configuration, set the operating parameters that meet your process control needs now, and change them later to meet new ones. Features Dual Displays - Vacuum fluorescent alphanumeric displays and indicators with dedicated PV display. Deviation Bargraph - “On Control” indication or up to ± 10% deviation display. Easy Configuration - Multilanguage prompts, in programmed sequence, provide guidance during configuration. Individual, reliable tactile keys provide positive operator feedback. There are no internal jumpers to set. Universal Isolated Input Input 1 accepts 10 thermocouple types, RTDs, Radiamatic RHs, mA, mV or voltage inputs through keyboard configuration. It is isolated from Input 2 and all other circuits. (See Table 1.) Thermocouple Failsafe Configurable upscale or downscale burnout and failsafe output level. Decimal Point Location Configurable for none, one, or two places. L L 51-52-03-07 2/97 Page 1 of 12 Specification ALM 1 2 DI 1 2 RSP OUT 1 2 FUNCTION FC MAN 3000 % SP 3000 LOWER DISPLAY MANUAL AUTO SETPOINT SELECT RUN HOLD SET UP 22069 Figure 1 - UDC3000 Versa-Pro Controller Accutune IITM - Provides a new, truly plug and play tuning algorithm, which will, at the touch of a button or through a digital input, accurately identify and tune any process including those with deadtime and integrating processes. This speedsup and simplifies startup plus allows retuning at any setpoint. Also included is the original Accutune SP Adaptive tuning that can automatically retune whenever a SP step change is implemented. Fuzzy Logic - This new feature uses fuzzy logic to suppress process variable overshoot due to SP changes or externally induced process disturbance. It operates independently from Accutune tuning. It does not change the PID constants, but temporarily modifies the internal controller response to suppress overshoot. This allows more aggressive tuning to co-exist with smooth PV response. It can be enabled or disabled depending on the application or the control criteria. Manual/Automatic Modes Bumpless, balanceless transfer between control modes. Two Local Setpoints - Can be configured to provide two local setpoints, keyboard or optional remote switch selectable. Universal Switching Power Operates on any line voltage from 90 to 264 Vac 50/60 Hz without jumpers. 24V ac/dc instrument power available as an option. Limit Control - provides a latching relay which is activated whenever the PV goes above or below a preset setpoint value. An alarm indicator will light when the output is activated. Reset is through a key on the front of the controller or an external switch. Setpoint Rate - Lets you define a ramp rate to be applied to any local setpoint change. A separate upscale or downscale rate is configurable. A single setpoint ramp is also available as an alternative. Industrial Automation and Control, 110 Virginia Drive, Fort Washington, PA 19034 Printed in U.S.A. ■ Copyright 1997 Honeywell Inc. 51-52-03-07 Page 2 Features, continued Optional Features (Fig. 4) Optional Features continued CE Mark- Conformity with 73/23/EEC, Low Voltage Directive and 89/336/EEC, the EMC Directive Moisture Resistant Front Panel Capable of meeting NEMA 3 and IEC529 IP65 (i.e. hosedown) requirements. Timer - This standard feature provides a configurable time period of 0 to 99 hours, 59 minutes. Alarm 1 is dedicated to be active at the end of the timeout period. Timer “start” is selectable as either the RUN/HOLD key or Alarm 2. The optional Digital Input can also be configured to start the Timer in addition to either the keyboard or Alarm 2. The Timer status shown in the lower display is selectable as either time remaining or elapsed time. Two Sets of Tuning Constants Two sets of PID parameters can be configured for each loop and automatically selected. Heat/Cool Capability - Provides split range control with independent PID tuning constants - one for heating, one for cooling, plus mixed output forms. Alarm Selection - None, one, or two relays to activate external equipment when preset high/low setpoints are reached. There is an indicator for each alarm. Setpoint Ramp - Provides single programmable setpoint ramp of up to 255 minutes duration which is repeatable and activated by the Run/Hold key. Output Rate Limiter - A maximum output rate may be configured for both the upscale and downscale output directions. Data Security - Five levels of keyboard security protect tuning, configuration, and calibration data, accessed by a configurable 4-digit code. Nonvolatile EEPROM memory assures data integrity during loss of power. Quality/Support - The UDC3000 is covered by a 2-year warranty and backed up by a toll-free phone number for technical assistance. Second Input - Isolated high level input available for remote setpoint signal, PV signal via digital inputs, or motor slidewire input. (Table 1) Auxiliary Output* - This isolated Auxiliary Output can be scaled from 4-20 mA for 0 to 100% for any range. It can be configured to represent Input 1, Input 2, PV, active Setpoint, Local SP1, Deviation, or the Control Output. Communications* - Provides a link between the UDC3000 and a Honeywell supplied interface device capable of communicating via RS232 (DMCS), or direct communication via the RS422/485 communications option to a host computer. Approval Body Options - FM approval, CSA certification and UL Recognition are available options. UL Recognition applies to regulatory use only. 2 Digital Inputs - Allows remote dry contact closure to select one of the following for each digital input: • Manual control mode • Local setpoint 1 • Local setpoint 2 • Direct controller action • Reset of Limit Controller • Hold SP Ramp/Programming • Select PID set 2 • PV = Input 2 • External program reset • Disable PID integral action • To Run - SP Ramp/Program • To Automatic output value • Manual mode, failsafe output • Disable keyboard • Start Timer • To Auto/Manual Station • ToTune Also allows the following selections to be combined with the above selections: • Select PID set 2 • Direct controller action • Local setpoint 2 • Disable adaptive tune Auto/Manual Station Plus Backup Control - You can use a single UDC3000 to act as both an Auto/Manual Station PLUS a backup PID Controller, should the primary loop controller fail. Since the PID control is sometimes implemented in the PLC, this feature provides a very costeffective way to insure the process does not have to shutdown or remain in manual mode if the PLC should fail. Switching from the Auto/Manual Station to the back-up control mode is accomplished using the Digital Input option. Setpoint Ramp/Soak Programming - Enables you to program and store 6 Ramp and 6 Soak segments for setpoint programming. Run or Hold of program is keyboard or remote switch selectable. Transmitter Power - Provides up to 30 volts to power a 2 wire transmitter (requires use of alarm 2 open collector output selection or auxiliary output.) * AuxOut and communications are mutually exclusive (only one may be specified). Physical Description The controller is housed in a 5.8 inch deep, black metal case with a dark gray elastomer bezel, that can be panel mounted in a 1/4 DIN cutout, (see Figure 5.) The plug-in chassis allows easy access to the controller board and its various option boards. All power, input, and output wiring are connected to screw terminals on the rear panel, (see Fig 6.) Blue and tan elastomer bezels are optionally available. Inputs Each analog input is sampled 3 times a second, amplified and then converted to a digital signal which is isolated and passed to the microprocessor. The primary input can be one of various Thermocouple, Radiamatic, or Linear actuations, (see Table 1.) A second input provides a remote setpoint function and accepts a 4 to 20 mA or 1 to 5 Vdc range that can be characterized. All ranges are keyboard selectable. External cold junction compensation is provided. You can select upscale downscale, or failsafe sensor break protection. A configurable digital filter of 0 to 120 seconds for each Input provides input signal smoothing, if required. 51-52-03-07 Page 3 Output Types The following output types are available per the model selection guide: • Current output • Electromechanical relays • Solid state relays • Open collector output • Solid state relay (10 amp) externally mounted (optional) • Auxiliary current output (optional) Output Algorithms, cont Current/Relay Duplex (Relay = Heat) - a variation of Duplex with Current active for 0 to 50% output (Tuning Set 2) and Relay active 50 to 100% output (Tuning Set 1). Current/Relay Duplex (Relay = Cool) - a variation of Duplex with Current active for 50 to 100% output and Relay is active for 0 to 50% output. “Universal” Output Model Flexibility of the Output Algorithms allows the Current Output Model Output Algorithms with 2 Alarms (DC300K-E) to be The UDC3000 is available with one also configured for time simplex, or more of the following output time duplex, or three position step algorithms: control plus, of course, the original Time Proportional - provides Oncapability of current simplex and Off or Time Proportional (Relay) current/time duplex control. A Relay output. Output Model with Auxiliary Output can also be configured for these Current Proportional - supplies proportional direct current output for output algorithms. final control elements which require Control Algorithms a 4-20 mA signal. Position Proportional - positions a Depending on the output algorithms reversible motor with a feedback specified, the controller can be slidewire in proportion to the output configured for the following control of the control algorithm. Requires 2 algorithms: output relays. • On-Off Time Proportional Duplex • PID-A depending on which control • PID-B algorithm you select, this duplex • PD with Manual Reset output algorithm can provide On• Three Position Step Control Off Duplex, Time Proportional The Three Position Step Duplex, or 3 Position Step Control. Control algorithm allows the The time proportional duplex output control of a valve (or other actuprovides independent PID tuning ator), with an electric motor constants and two time proportional driven by two controller output outputs; one for heat zone above relays; one to move the motor the 50% output, and one for cool upscale, the other downscale zone below 50% output. without a feedback slidewire Current Proportional Duplex linked to the motor shaft. similar to current proportional but Accutune does not apply to this provides a second set of tuning algorithm. Features of this parameters and a split range algorithm are: current output or a second current 1. The controller can use all output via the Auxiliary output three modes of control option, for the heat and cool zones. (PID) instead of PI only. 2. Three Position Step is an automatic backup mode to Position Proportional Control if the feedback slidewire signal should fail. Configuration You decide how the controller is to interact with the process by selecting, through simple keystrokes, the functions you want. Multi-language prompts guide the operator step-by-step through the configuration process assuring quick and accurate entry of all configurable parameters. There are no internal jumpers, all configuration is via the keyboard. Five languages are available via configuration; English, French, German, Spanish and Italian. Control Modes Manual or Automatic control with bumpless, balanceless transfer between modes is a standard feature. In the manual mode, the operator directly controls the controller output level. In the automatic mode, the controller will operate from a local setpoint, or a remote setpoint provided at the second input or via communications. Alarms Alarm output terminals are located at the rear terminal panel. One or two electromechanical alarm relays are available to activate external equipment when preset alarm set points are reached. Each of the two alarms can be set to monitor two independent set points. Each alarm setpoint can be either high or low alarm. The alarm type can be selected to be either of the inputs, the Process Variable, Deviation, Output, Shed from communications or to alarm on manual mode. It can also be used as an On or Off event at the beginning or end of a Ramp/Soak segment. The alarm hysteresis is configurable from 0 to 100% of range. 51-52-03-07 Page 4 L Upper Display - Six Characters • Normal Operation - four digits dedicated to display the process variable • Configuration Mode - displays parameter value or selection Lower Display - eight characters • Normal Operation - displays operating parameters and values • Configuration Mode - displays function groups and parameters Indicator definition when lit F - °Fahrenheit being used MAN - controller in manual mode A - controller in automatic mode C - °Centigrade being used R - Run SP Ramp/Program H - Hold SP Ramp/Program Indicator definition when lit ALM - Alarm conditions exist DI - Digital Input active RSP - Remote SP or SP2 active OUT - Control Relay 1 or 2 on ALM 1 2 F C DI 1 2 RSP OUT 1 2 R 3000 SP 3000 FUNCTION LOWER DISPLAY MAN MANUAL AUTO % SETPOINT SELECT Keys - See below SET UP MAN and A off — communications option active RUN HOLD Deviation Bargraph • Center bar indicates PV is within ± 1% of setpoint. • Next bar will light if PV is between ±1% but less than ±2% in deviation. • If PV is equal to or greater than ±10% deviation, the center bar plus all ten deviation bars will light. 22816 Figure 2 - Operator Interface Operator Interface (Fig. 2) Indicators - They provide alarm, control mode, and temperature units Sequentially displays Set Up groups and allows SET UP indication. There is also indication of Function key to display individual functions. when Remote Setpoint is active, the status of the control relays, and FUNCTION Selects functions within each Set Up group. whether a setpoint program is in Run or Hold mode. Selects an operating parameter to be shown in A 21-segment bargraph displays LOWER DISPLAY the lower display. deviation to ±10% of span and an “On-Control” indicator. Selects Manual or Automatic control mode. MANUAL Displays - A 4-digit upper display AUTO (may be disabled via configuration) is dedicated to the process variAlternately selects Local setpoint 1 and Remote able during normal operation with SETPOINT setpoint or between two local setpoints. alternate 6-character information SELECT (may be disabled via configuration) displayed when in the configure mode. Initiates or holds the single setpoint ramp RUN or Ramp/Soak program. HOLD During normal operation, the lower (may be disabled via configuration) display shows key-selected operating parameters such as Output, Increases the setpoint, output, or Setpoints, Inputs, Deviation, active configuration values displayed. Tuning Parameter Set, Timer Status, Decreases the setpoint, output, or or minutes remaining in a setpoint configuration values displayed. ramp (4 digits). It also provides 22071 guidance, through prompts, for the operator during controller configuration (8-characters). Figure 3 - Key Functions 51-52-03-07 Page 5 Specifications Design CE Conformity (Europe) This product is in conformity with the protection requirements of the following European Council Directives: 73/23/EEC, the Low Voltage Directive, and 89/336/EEC, the EMC Directive. Conformity of this product with any other “CE Mark” Directive(s) shall not be assumed. Product Classification: Class I: Permanently Connected, Panel Mounted Industrial Control Equipment with protective earthing (grounding). (EN61010-1) Enclosure Rating: Panel Mounted Equipment, IP 00, this controller must be panel mounted. Terminals must be enclosed within the panel. Front panel IP 65 (IEC 529). Installation Category (Overvoltage Category): Category II: Energy-consuming equipment supplied from the fixed installation. Local level appliances, and Industrial Control Equipment. (EN 61010-1) Pollution Degree: Pollution Degree 2: Normally non-conductive pollution with occasional conductivity caused by condensation. (Ref. IEC 664-1) EMC Classification: Group 1, Class A, ISM Equipment (EN 55011, emissions), Industrial Equipment (EN 50082-2, immunity) Method of EMC Assessment: Technical File (TF) Declaration of Conformity: 51309303-000. Accuracy ± 0.20% of span typical (± 1 digit for display) 15 bit resolution typical Temperature Stability ± 0.01% of Full Scale / ˚C change Input Signal Failure Protection Thermocouple Inputs: Upscale or downscale burnout Burnout Current: 0.13 microamps Failsafe Output Level: Configurable 0-100% Input Impedance 4-20 Milliampere Input: 250 Ohms 0-10 Volt Input: 200K Ohms All Other: 10 Megohms Stray Rejection Common Mode AC (50 or 60 Hz): 120 dB (with maximum source impedance of 100 Ohms) or ± 1 LSB ((least significant bit) whichever is greater. Normal Mode AC (50 or 60 Hz): 60 dB (with 100% span peak-to-peak maximum) Alarm Output One SPDT electromechanical relay. A second alarm is available using the second control relay. This is not available with Relay Duplex, Position Proportional, or Three Position Step control. Up to four setpoints are independently set as high or low alarm, two for each relay. Setpoint can be on either Input, Process Variable, Deviation, Communication Shed, or Output. A single adjustable hysteresis of 0.0 to 100.0% is provided. The controller can also be set to alarm on shed from communications. The alarm can also be set as an on or off event at the beginning of a setpoint ramp/soak segment. Alarm Relay Contacts Rating Resistive Load: 5 ampere at 120 Vac or 30 Vdc, 2.5A at 240 Vac. 51-52-03-07 Page 6 Specifications (continued) Design (continued) Controller Output Types Current Output (Isolated) Range can be set anywhere between 0 to 21 mA, and as direct or reverse action. Resolution: 11 bits for 0 to 21 mA Accuracy: 0.5% full scale Temperature Stability: 0.1% F.S. / ˚C Load Resistance: 0 to 1000 ohms Electromechanical Relays (One or Two) SPDT contacts. Both Normally Open and Normally Closed contacts are brought out to the rear terminals. Internally socketed Resistive Load: 5 amps @ 120 Vac, 2.5A at 240 Vac or 30 Vdc Inductive Load: 50 VA @ 120 Vac or 240 Vac Motor: 1/6 H.P. Solid State Relays (One or Two) SPST solid state contacts consisting of a triac N.O. output. Internally socketed Resistive Load: 1.0 amp @ 25 ˚C and 120 or 240 Vac 0.5 amp @ 55 ˚C and 120 or 240 Vac Inductive Load: 50 VA @ 120 Vac or 240 Vac Open Collector Outputs (One or Two) Maximum Sink Current: 20 mA Overload Protection: 100 mA Internally powered @ 30 Vdc Opto-isolated from all other circuits except current output, but not from each other. Socketed jumper assembly replaces relay. Solid State Relays (10 amps) One or two externally mounted triac N.O. outputs for use with open collector outputs. Resistive Load: 15 amps @ 25 ˚C and 120 or 240 Vac 10 amps @ 55 ˚C and 120 or 240 Vac Inductive Load: 50 VA @ 120 Vac or 240 Vac Motor Rating: 1 HP @ 25 ˚C 0.75 HP @ 55 ˚C Controller Output Algorithms On-Off or Time Proportional One relay or open collector output. Control action can be set for direct or reverse. Time Proportional Relay Resolution: 3.3 msec On-Off Duplex, Three Position Step Control, or Time Proportional Duplex Two relays or open collector outputs. Control action can be set for direct or reverse. Time Proportional Relay Resolution: 3.3 msec Current Proportional A single 4-20 mA current output signal which can be configured for direct or reverse action. Current Proportional Duplex A single split current output for both heat and cool (4-12 cool, 12-20 heat) or a combination of current proportional output (Heat = 50 to 100% of range) and auxiliary current output (Cool = 0 to 50% of range). Both are 4-20 mA signals which can be set for direct or reverse action. Position Proportional Two SPDT electromechanical or solid state relays operate motor having a 100 ohm to 1000 ohm feedback slidewire. Current/Time Duplex Variation of time proportional duplex for Heat/Cool applications. Time proportional output (heat or cool) is a relay. Current proportional output (Heat or Cool) is a 4-20 mA signal that can be fed into a negative or positive grounded load of 0 to 1000 ohms and is operational over 50% of range or the entire range. Sampling Rate Inputs sampled 3 times a second 51-52-03-07 Page 7 Specifications (continued) Design (continued) Auxiliary Linear Output (Optional) (Isolated) 21 mA dc maximum into a negative or positive grounded load or non-grounded load of 0 to 1000 ohms. Output range can be set anywhere between 0 to 21 mA, and as direct or reverse action. It can be configured to represent either Input, PV, Setpoint, Deviation, or Control output. The range of the auxiliary output, as a function of the selected variable, can be scaled. This output can be used as a second current output for current duplex outputs. Resolution: 12 bits over 0 to 21 mA Accuracy: 0.2% of full scale Temperature Stability: 0.01% F.S. / ˚C Communications Interface (Optional) DMCS Baud Rate: 19200 baud Length of Link: 4000 ft maximum Link Characteristics: Two wire, multi-drop proprietary protocol, 31 drops maximum RS422/485 Baud Rate: 300, 600, 1200, 2400, 4800, or 19,200 baud Parity: Odd or Even Length of Link: 4000 ft maximum Link Characteristics: Two wire or four wire, multi-drop RS422 ASCII protocol, 15 drops maximum Digital Inputs (Optional) +15 Vdc source for external dry contacts or isolated solid state contacts. The Digital Input option detects the state of external contacts for either of the two inputs. On contact closure the controller will respond according to how each digital input is configured. Opening contact causes return to previous state. Input Filter Software : Single pole lowpass section with selectable time constants, off to 120 seconds available on both analog inputs. Digital Displays Vacuum fluorescent, alphanumeric. A six-character upper display dedicated to the process variable (4 digits). Alternate information displayed during configuration mode. A eight-character lower display primarily shows key selected operating parameters (4 digits). Also provides guidance during controller configuration. Indicators Alarm Relay Status (ALM 1 or 2) Control Mode (A or MAN) Temperature Units (F or C) Remote Set Point or SP2 Active (RSP) Control Relay Status (OUT 1 or 2) Digital Input Status (DI 1 and 2) Bargraph 21 segment, vertical Deviation bargraph Center bar lit when “on” control Deviation to ± 10% of PV span in 1% increments Modes of Operation Manual Automatic with local setpoint Automatic with remote setpoint (2-input units only) Dimensions See Figure 5. Mounting Panel-mounted, 5.82 inch depth Wiring Connections Screw terminals on the rear of the case. (See Figure 6.) Power Consumption 18 VA maximum Power Inrush Current 10A Max. for 4 ms (under operating conditions) CAUTION When applying power to more than one UDC3000, make sure that sufficient power is supplied. Otherwise, the controllers may not start up normally due to voltage drop from the inrush current. Weight 1.3 kg (3 lbs.) 51-52-03-07 Page 8 Specifications (continued) Environmental and Operating Conditions Parameter Reference Rated Operative Limits Transportation and storage Ambient Temperature 25 ± 3˚C 77 ± 5˚F 15 to 55 ˚C 58 to 131 ˚F 0 to 55 ˚C 32 to 131 ˚F -40 to 66 ˚C -40 to 151 ˚F Relative Humidity Vibration Frequency (Hz) Acceleration (g) 10 to 55* 10 to 90* 5 to 90* 5 to 95* 0 0 0 to 70 0.1 0 to 200 0.5 0 to 200 0.5 Mechanical Shock Acceleration (g) Duration (ms)) 0 0 1 30 5 30 20 30 Voltage (Vdc) +24 ± 1 20 to 27 20 to 27 -- 120 ± 1 240 ± 2 90 to 264 90 to 264 --- Voltage (Vac) 90 to 264Vac (CSA models rated to 250V max.) 24Vac Frequency (Hz) (For Vac) 24 ± 1 20 to 27 20 to 27 -- 50 ± 0.2 60 ± 0.2 49 to 51 59 to 61 48 to 52 58 to 62 --- * The maximum rating only applies up to 40˚C (104˚F). For higher temperatures, the RH specification is derated to maintain constant moisture content. Table 1 - Input Actuations Range PV Input Thermocouples B* E* E (low) J J (low) K K (low) NiNiMoly (NNM) NiNiMoly (NNM low)) NIC (Nicrosil Nisil) R S T T (low) W5W26 W5W26 (low) RTD (IEC) ALPHA = 0.00385 100 Ohms 100 Ohms (low) 500 Ohms Radiamatic RH Linear** Milliamps Millivolts Volts ˚F 0 -454 -200 0 20 0 -20 32 32 0 0 0 -300 -200 0 0 to to to to to to to to to to to to to to to to ˚C 3300 1832 1100 1600 770 2400 1000 2500 1260 2372 3100 3100 700 500 4200 2240 -300 to 1200 0 to 300 -300 to 1200 1400 to 3400 -18 -270 -129 -18 -7 -18 -29 0 0 -18 -18 -18 -184 -129 -18 -18 to to to to to to to to to to to to to to to to -184 to -18 to -184 to 760 1815 1000 593 871 410 1316 538 1371 682 1300 1704 1704 371 260 2316 1227 649 149 649 to 1871 4 to 20 mA 0 to 10 mV 10 to 50 mV 1 to 5V 0 to 10V Optional 2nd Input Milliamps Volts Slidewire for Position Proportioning 4 to 20 mA 1 to 5V 100 to 1000Ω * May require Field calibration to achieve rated accuracy below 1000 ˚F for type B and below -200 ˚F for type E thermocouple. ** Not available on FM approved Limit models. 51-52-03-07 Page 9 General Reference Data Data Isolation (Functional) AC Power : is electrically isolated from all other inputs and outputs to withstand a HIPOT potential of 1900Vdc for 2 seconds per Annex K of EN61010-1. Analog Inputs and Outputs: are isolated from each other and all other circuits at 850Vdc for 2 seconds. Digital Input and Digital Output: are isolated from all other circuits at 850Vdc for 2 seconds. Relay Contacts: with a working of 115/230 Vac, isolated from each other and all other circuits at 345 Vdc for 2 seconds. Surge Withstand Capability (SWC) Immunity: ANSI/IEEE C37.90.1, Surge Withstand Capability (SWC) (Formerly IEEE 472) Mains power input and relay contact outputs: 2.5 kV, Common Mode and Differential Mode. All other circuits: 1.0 kV, Common Mode and Differential Mode. Radio Frequency Immunity: No effect on performance from a 5 W walkie-talkie operated at 27, 151 or 450 MHz, one Interference (RFI) meter from the controller. Model Number Interpretation Key Number Table 1 Table 2 Table 3 Table 4 Table 5 D C 3 0 0 Output #1 C = Current 4 – 20mA without Alarms K = Current 4 – 20mA with Alarm 1 E = Relay, Electromechanical – 5AMP with Alarm 1 A = Relay, Solid State AC – 1AMP with Alarm 1 T = Open Collector Output – 20mA with 1 Alarm Output #2 or Alarm #2 O = None E = Relay, Electromechanical – 5AMP (SPDT) A = Relay, Solid State AC – 1AMP (SPST) T = Open Collector Output – 20mA External Interface O – – = None 1 – – = RS422/485 2 – – = Auxiliary Output 4 – – = DMCS Software Options – O – = None – A – = Accutune – B – = Setpoint Program and Accutune Digital Inputs – – O = None – – 3 = Digital Inputs (2) 0 Options 0 – – – = 90-264Vac Power 1 – – – = 24Vac/dc Power B – – – = Blue Bezel with 90-264Vac Power T – – – = Tan Bezel with 90-264 Vac Power C – – – = Blue Bezel with 24Vac/dc Power D – – – = Tan Bezel with 24Vac/dc Power – 0– – = None – A – – = Approvals CSA,FM,UL – F – – = Approvals - FM, CSA – – 0– = None – – T – = Customer I.D. Tag – – – 0 = None – – – D = DIN Cutout Adapter Optional Input – 0 = None – 1 = 4–20mA or 1–5V – 2 = Slidewire Input for Position Proportional or 3 Position Step with motor position indication PV Input 1 – = T/C, RTD, mV, 1–5V 2 – = T/C, RTD, mV, 1–5V, 4–20mA 3 – = T/C, RTD, mV, 1–5V, 4–20mA,0–10V 22603 Figure 4 - Model Number Interpretation 51-52-03-07 Page 10 LL Dimensions 92 3.622 96 3.780 ALM 1 2 1 2 ALM ALDI 1 FFC PV 1 2 13 24 MDI RSP 1 2 C 96 3.780 RSP 21 2 OUT 11 2 2 OUT FUNCTION SET UP 24 Max Panel .945 Thickness FC LOWER DISPLAY +0.008 -0.0 +0.03 -0.0 MAN M A N MAN %% % 92 3.622 Panel Cutout MANUAL AUTO SETPOINT SELECT +0.008 -0.0 +0.03 -0.0 RUN HOLD 10 Max (2) .394 2.4 with optional .093 rear cover 90.7 3.57 21.6 .850 Figure 5 - UDC3000 Versa-Pro Controller dimensions - not to scale 147.3 5.82 22073 51-52-03-07 Page 11 Wiring Diagram UDC 3000 EXTERNAL WIRING 10 L1/H 11 L2/N 12 Instrument Power 22 0 23 24 25 26 IN 2 IN 1 27 DI 1 DI 2 1 ! CTL 1 2 3 13 SHIELD 4 14 RX+/TX+ 5 15 RX-/TX- 6 16 TX+ or AUX+ 7 17 TX- or AUX- 8 4-20 MA CTL 2 ALM 2 ALM 1 9 22840 NOTE: The product manual should be consulted for specific details and precautions regarding wiring. Figure 6 - External Wiring Diagram 51-52-03-07 Page 12 Ordering Information For the complete ordering information, request Model Selection Guide: 51-51-16-32 for UDC3000 Universal Digital Controller or . . Honeywell offers a full Iine of Sensors, Transmitters, and Final Control Devices for use with the UDC3000 Universal Digital Controller. These devices include: Thermocouples, RTDs Pressure Transmitters, Flow Transmitters, Liquid Level Transmitters. Valve, Actuators, and Electric Motors. Specifications are subject to change without notice. Distributor : For more information, contact your nearest Honeywell Response Center listed below. Industrial Automation and Control Honeywell Inc. In the U.S.A.: Honeywell Industrial Automation and Control, 16404 North Black Canyon HWY., Phoenix, AZ 85023, (800) 343-0228 In Europe: Honeywell S.A., 80084 Amiens Cedex 2, (33) 22.54.56.56 Honeywell Control System Ltd., Honeywell House, Bracknell, UK-RG 12 1 EB, (44) 1344 826000 In Japan: Yamatake-Honeywell Co. Ltd., Nagai Int’l Bldg., 2 - 12 - 19 Shibuya-Ku, Tokyo 150 Japan, 81-3-3486-2051 In Asia: Honeywell Asia Pacific Inc., Room 3213-3225, Sun Hung kai Centre, No. 30 Harbor Road, Wanchai, Hong Kong, (852) 829-8298 In the Mediterranean: Africa and Middle East Region, Honeywell SpA, Via Vittor Pisani 13, 20124 Milano, Italy (39-2) 67731 Honeywell Pacific Division: Honeywell Pty Ltd., 5 Thomas Holt Drive, North Ryde Sydney, NSW Australia 2113, (61-2) 353 7000 In Canada: The Honeywell centre, 155 Gordon Baker Road., Ontario M2H 3N7, 1-800-461-0013 In Latin America: Honeywell Inc.,14505 Commerce Way, Suite 500, Miami Lakes, Florida 33016-1556, (305) 364-2300
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Create Date : 1997:02:13 12:34:58 Producer : Acrobat Distiller 2.1 for Windows Modify Date : 1998:02:25 10:49:25 Page Count : 12 Page Mode : UseOutlines Page Layout : SinglePageEXIF Metadata provided by EXIF.tools