Sensing and Control

SWITCH APPLICATIONS
The odds are that Honeywell Sensing and Control can meet your switch demands. Designers of heavy-duty equipment have trusted
Honeywell pressure and vacuum switches for many years in applications that are constantly subjected to harsh environments…from
chemical splashes, salt water, high pressure spikes…we’ve got you covered. Our standard line is quite extensive, but if it is not exactly
what your requirements call for we can modify an existing part or create an original just for you. Honeywell has produced millions of
custom-built switches for automotive, pool and spa, powershift transmissions, anti-skid braking systems, excavator hydraulic systems,
water pump systems, and dental air compressors, to name just a few. Our highly skilled model shop, certified lab and engineering staff
can work with you through the design phase, prototype stage, all the way through to the testing phase. And if time is a crucial factor,
rapid prototyping technology can now allow us to provide you with a sample in days.

WARNING! Suitability of application is responsibility of
user. Extreme heat and vibration should be avoided at
mounting points such as on top of an engine over a hot
manifold. (MAX operation temp 250° F). Always install by
using a wrench on the hex base. Torquing at any other part
of the switch voids the warranty or may cause malfunction.
A Polyimide film diaphragm is utilized in the pressure switch
and is not recommended for use with water. However,
a Teflon diaphragm is available for water applications.
Compatibility with the brass or steel external pressure switch
material is the responsibility of the user.
For maximum operating pressures see appropriate switch
family specifications.
Contact Honeywell Engineering whenever use of switch or
fluid compatibility is questioned.

!

CONTENTS

• Ultra Duty Pressure Switches 10-400 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.3
• Extended Duty Pressure Switches 0.5-150 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.4
• Extended Duty Vacuum Switches1.1-22” Hg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.6
• Extended Duty Piston Switches 200-1000 psi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . p.7
• Factory Set Variable Differential Pressure & Vacuum Switches 2-70 psi & 2-22” Hg . . . p.8
• High Pressure Environmentally Sealed Extreme-Duty Switches 35-3000 psi . . . . . . . . . p.9

WARNING
PERSONAL INJURY

DO NOT USE these products as safety or emergency stop devices, or in any other application where failure of the product could
result in personal injury. Failure to comply with these instructions could result in death or serious injury.

2

Set Points from 10-400 psi
5000 Series Ultra Duty Pressure Switch
Honeywell Sensing and Control has designed a high pressure/low set point
pressure switch for applications that see sudden pressure spikes and high
system pressures that can result in early switch failures. This series has been
strengthened to prevent cracking of the base with plated steel and screw
machined components in a 3-piece design. Modifications to the effective
area of the pressure cavity and size of the diaphragm button and diaphragm
o-ring are what makes the switch capable of handling sudden pressure
transients and high system pressures that are common in applications such as
braking, transmission and hydraulic systems.

2.3” REF.

The switch’s physical appearance is similar to our 5000 Series switches with a
height of only 2.3” (approx) and a diameter of 1.47”. In comparison to our
5000 Series Switch the burst rating has significantly increased from 1250 psi
to over 4000 psi on the new design.
Specifications
Type: Direct action blade contact
Contacts: Silver alloy, gold plated
Set Point Range: 10-400 PSI
Operating Pressure: 500 PSI
Proof Pressure: 2000 PSI
Burst Pressure: 4000 PSI
Base: Plated Steel — Screw Machined
3-piece construction
Diaphragm: Polymide Film
Connector: 1/8-27 NPT Male Thread
Temperature Range: -40°F to +250°F
Terminals: #8-32 screws, 1/4” blade,
280 Series Metripack
Circuitry: SPST-N.O., N.C., SPDT
Cover: Glass Reinforced Polyester
Options: Base connector sizes, wire
leads, N.O./N.O. dual circuit and
N.C./N.C. dual circuit.
Ratings:
Resistive:
Inductive:

15
8
4
1
0.5

AMP6 VDC
AMP- 12 VDC
AMP- 24 VDC
AMP- 120 VAC
AMP- 240 VAC

Approximate Dead Band
Standard Switches
Contact Setting

Dead Band

10-35 PSI
35-75 PSI
75-150 PSI
150-250 PSI
250-400 PSI

15-25 PSI
25-35 PSI
40-60 PSI
50-70 PSI
80-100 PSI

1.47” REF.

5000 Series Ultra Duty
Pressure Switches
Contact
Setting

10-35 PSI
±4 psi

35-75 PSI
± 6 psi

75-150 PSI
±10 psi

150-250 PSI
± 15 psi

250-400 PSI
± 20 psi

Factory Circuitry
Set At

20 PSI

60 PSI

100 PSI

200 PSI

2 Terminals
Screw
Part #

Blade
Part #

N.O.

83298

83313

N.C.

83299

83314

DC*

83300

83315

N.O.

83301

83316

N.C.

83302

83317

DC*

83303

83318

N.O.

83304

83319

N.C.

83305

83320

DC*

83306

83321

N.O.

83307

83322

N.C.

83308

83323

DC*

83309

83324

N.O.

83310

83325

N.C.

83311

83326

300 PSI
DC*

83312

83327

Metri-Pack Switches
10-30 PSI
30-65 PSI
65-125 PSI
125-200 PSI
200-400 PSI

3

20-35 PSI
35-55 PSI
60-85 PSI
85-115 PSI
150-200 PSI

Metri-Pack Integral Connector
(See Note 1)
Contact
Setting

10-30 PSI
± 4 psi

30-65 PSI
± 5 psi

Factory Circuitry
Set At

20 PSI

45 PSI
85 PSI

65-125 PSI
± 7 psi

125-200 PSI
± 10 psi

200-400 PSI
± 15 psi

165 PSI

Part #

N.O.

83328

N.C.

83329

DC*

83330

N.O.

83331

N.C.

83332

DC*

83333

N.O.

83334

N.C.

83335

DC*

83336

N.O.

83337

N.C.

83338

DC*

83339

N.O.

83340

N.C.

83341

DC*

83342

300 PSI

Note 1: Mating connector for N.O. and N.C. is
Packard Part# 15300027; Mating connector for
DC is Packard Part# 12034147.
DC*- The N.C. is the reference circuit for the
DC Switch; the N.O. circuit is not adjusted. The
approximate dead band between the N.C. and
N.O. circuit is shown in the charts. For applications
requiring the N.O. circuit as the reference circuit,
the N.C. circuit is not adjusted.

Set Points from 0.5 to 150 psi
5000 Series Extended Duty Pressure Switch With Direct Action Blade Contacts
The 5000 Series switch is specifically
designed to stand up to extended duty
applications. This switch is factory set
but capable of field adjustment. It
features a Kapton diaphragm for
compatibility with a wide variety of
fluids, and various terminations
including a Metri-Pack connector that
forms a tight seal when connected.
Among the outstanding design benefits
are its durable construction, compact
size, and enhanced set point integrity.

Standard Specifications
Type:

Direct action
blade contact
Contacts:
Silver alloy,
gold plated
Set Point:
Factory set
from 0.5 to 150 PSI
Operating Pressure:
150 PSI for 0.5-24 PSI set point range,
250 PSI for 25-150 PSI set point range
Proof Pressure: 500 PSI
Burst Pressure: 750 PSI for 0.5-24 PSI
set point range
1250 PSI for 25-150 PSI
set point range.
Ratings:
Resistive:

15
8
4
Inductive:
1
0.5

AMPAMPAMPAMPAMP-

6
12
24
120
240

VDC
VDC
VDC
VAC
VAC

Switch Boot P/N 79380
for Vacuum and Pressure

2.9” REF.

Diaphragm: Polyimide film
2.3” REF.

Temperature
Range:

-40° F to + 250° F

Connector:

1/8 -27 NPT male thread

Terminals:

#8-32 screws,
1/4” blade,
280 Series Metri-Pack

Circuitry:

SPST-N.O., N.C.,
1 circuit adjustable dual
circuit, or 2 circuits
adjustable dual circuit.

1.47” REF.

1.47” REF.

Also available are
N.O./N.O. dual circuit

5000 Series Switch
with Screw Terminals

and N.C./N.C. dual circuit.
Base:

Plated Steel

Cover:

Glass reinforced polyester

Options:

Brass, plastic or stainless
steel base; various base
connector thread sizes;
wire leads (potted & sealed).

NOTE: OPERATING MEDIA (PRESSURE SWITCH)
The pressure switch is designed to operate with air,
motor oils, transmission oils, jet fuels and other similar
hydrocarbon media.

4

5000 Series Switch
with Metri-Pack Terminal

5000 Series Pressure Switch With Standard Terminal
Contact
Setting

0.5-1 PSI
±0.3
1.1-3 PSI
±0.5
3.1-7 PSI
±1
8-13 PSI
±2
14-24 PSI
±3
25-50 PSI
±5
51-90 PSI
±7
91-150PSI
±10

Factory
Set At

Circuitry

1 PSI
2 PSI
4 PSI
10 PSI
15 PSI
35 PSI
60 PSI
100 PSI

N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.

Single Circuit
1 Terminal
Part Number

Screw
78630
78634
78142
78149
78143
78150
78144
78151
78145
78152
78146
78153
78147
78154
78148
78155

Single Circuit
2 Terminals
Part Number

Blade
78631
78635
78399
78406
78400
78407
78401
78408
78402
78409
78403
78410
78404
78411
78405
78412

Screw
78628
78632
76051
76061
76575
76577
76576
76578
76052
76062
76053
76063
76054
76064
76055
76065

Blade
78629
78633
76056
76066
76583
76585
76584
76586
76057
76067
76058
76068
76059
76069
76060
76070

Dual Circuit

Dual Circuit

One circuit adjustable1

Both circuits adjustable2

Part Number

Screw

Blade

78711

78712

76071

76076

76579

76587

76580

76588

76072

76077

76073

76078

76074

76079

76075

76080

5000 Series Pressure Switch With Metri-Pack Terminal
Single Circuit
(Mates with Packard
P/N 15300027)
Contact
Factory Circuitry
Setting
Set At
1-3 PSI
N.O.
2 PSI
±0.5
N.C.
4-6 PSI
N.O.
5 PSI
±1
N.C.
7-12 PSI
N.O.
10 PSI
±2
N.C.
13-24 PSI
N.O.
20 PSI
±3
N.C.
25-46 PSI
N.O.
35 PSI
±5
N.C.
47-76 PSI
N.O.
60 PSI
±6
N.C.
77-100 PSI
N.O.
85 PSI
±7
N.C.
101-126
N.O.
115 PSI
±9
N.C.
127-150 PSI
N.O.
135 PSI
±10
N.C.

Dual Circuit
One circuit adjustable1
(Mates with Packard
P/N 12034147)

Part Number

Part Number

77029
77020
77030
77021
77031
77022
77032
77023
77033
77024
77034
77025
77035
77026
77036
77027
77037
77028

77038
77039
77040
77041
77042
77043
77044
77045
77046

Note 1: Expected Dead Band (Higher than N.C. circuit)
Contact
Setting
0.5-3 PSI
4-7 PSI
8-13 PSI
14-24 PSI
25-50 PSI
51-90 PSI
91-150 PSI

Dead Band
1.5 PSI
2.5 PSI
3.5 PSI
8 PSI
15 PSI
23 PSI
40 PSI

5

Dual Circuit
Both circuits adjustable2
(Mates with Packard
P/N 12034147)

Contact
Setting3
3-4 PSI
±0.5
5-10 PSI
±1
11-24 PSI
±2
25-46 PSI
±3
47-76 PSI
+5/-2
77-100 PSI
+7/-2
101-126 PSI
+9/-2
127-150 PSI
+10/-2

Part
Number

77047
77048
77049
77050
77051
77052
77053
77054

Contact
Setting3

3-4 PSI
±0.5
5-8 PSI
±1
9-24 PSI
±2
25-50 PSI
±3
51-90 PSI
+5/-2
91-150 PSI
+8/-2

Part Number
Screw
Blade

76081

76086

76582

76590

76082

76087

76083

76088

76084

76089

76085

76090

Notes:
1. The N.C. circuit is the reference
circuit for the dual circuit switch;
the normally open circuit is not
adjusted. The expected dead band
between the N.C. & N.O. circuit
is shown in the chart below. For
applications requiring the normally
open circuit as the reference circuit
the N.C. circuit is not adjusted.
2. Switch may be adjusted so that:
A. N.C. circuit opens before N.O.
circuit closes.
B. N.C. and N.O. circuit have same
set point.
C. N.O. circuit closes before the
N.C. circuit opens. (There is no
dead band and both circuits are on
for a brief period of time.)
3. The tolerances given in the table
are applicable to a switch adjusted
so that the N.O. circuit closes
before the N.C. circuit opens and
applies to the N.C. circuit. The
N.O. set point and tolerances are
such that a minimum overlap of 1
PSI exists during which both circuits
are on.

Set Points from 1.1” to 22” Hg
5000 Series Extended Duty Vacuum Switches With Direct Action Blade Contacts
The 5000 Series switch is specifically
designed to stand up to extended duty
applications. This switch is factory
set. It features a fluorosilicone rubber
diaphragm for compatibility with a
wide variety of fluids, and various
terminations including a Metri-Pack
connector that forms a tight seal when
connected. Among the outstanding
design benefits are its durable
construction, compact size, and
enhanced set point integrity.

2.3” REF.

Switch Boot P/N 79380
for Vacuum and Pressure
Standard Specifications
Type:

Direct action blade
contact
Silver alloy, gold plated
Factory set
1.1 to 22” Hg

Contacts:
Set Point:
Vacuum:
Operating
Pressure:
30” Hg vacuum max.
Burst Pressure: 150 PSI
Ratings:
Resistive:

Inductive:
Diaphragm:
Temperature
Range:
Connector:
Terminals:

Circuitry:
Base:
Cover:
Options:

15 AMP6 VDC
8 AMP- 12 VDC
4 AMP- 24 VDC
1 AMP- 120 VAC
0.5 AMP- 240 VAC
Fluorosilicone elastomer
-40° F to + 250° F
1/8-27 NPT male thread
#8-32 screws,
1/4” blade,
280 Series Metri-Pack
SPST-N.O., N.C.
Brass
Glass reinforced
polyester
Various base connector
thread sizes; wire leads
(potted & sealed).

1.47” REF.

5000 Series Switch
with Screw Terminals

5000 Series Vacuum Switch
Internally Grounded
Part Number
Contact Setting
1.1-22” Hg

Circuitry
N.O.
N.C.

Screw

Blade

Screw

Blade

78813
78815

78814
78816

77342
77343

77344
77345

Standard set points are 2”Hg(27” H2O), 4”Hg, 9”Hg, and 17”Hg

Contact Setting

Tolerance

1.1-3”Hg (15-41”H2O)

±.22”Hg(3”H2O)

4-8”Hg

±1”Hg

9-17”Hg

±2”Hg

18-22”Hg

±3”Hg

6

Two Terminals
Part Number

Set Points from 200 to 1000 psi
5000 Series Extended Duty Piston Switches With Direct Action Blade Contacts

3.05” REF.
2.45” REF.

The 5000 Series piston switch is
specifically designed for extended duty
applications with set point requirements
from 200 to 1000 PSI. This switch is
factory set with various terminations
available including a Metri-Pack
connector that forms a tight seal when
connected. Among the outstanding
design benefits are its durable
construction, compact size, and
enhanced set point integrity. This switch
has a wide media compatibility making
it ideal for a number of applications.
Standard Specifications
Type:

1.47” REF.

1.47” REF.

5000 Series Piston Switch
with Screw Terminals

5000 Series Piston Switch
with Metri-Pack Terminal

Piston Switch
with Standard Terminal
Contact Setting
Range
200-400
±30

401-800
±60

801-1000
±90

Approximate
Differential
30-100
40-125
50-180

Circuitry
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.

Piston Switch
with Metri-Pack Terminal
Contact Setting
Range

Approximate
Differential

200-350

30-100

351-500

40-125

±30
±45

501-750
±60

50-150

Contacts:
Set Point:
Pressure:
Operating
Pressure:
1000 PSI
Proof Pressure: 2000 PSI
Burst Pressure: 3000 PSI
Ratings:
Resistive:

Single Circuit
Part Number
Screw
Blade
79700 79701
79702 79703
79704 79705
79706 79707
79708 79709
79710 79711

Dual Circuit *
one circuit adjustable

Part Number
Blade
Screw
79712

79713

79714

79715

79716

79717

Single Circuit
(Mates with Packard
P/N 15300027)

Dual Circuit *
one circuit adjustable
(Mates with Packard
P/N 12034147)

Circuitry

Part Number

Part Number

N.O.
N.C.
N.O.
N.C.
N.O.
N.C.

79718
79719
79720
79721
79722
79723

79724
79725
79726

* Note: The N.C. circuit is the reference circuit for the dual circuit switch; the normally open circuit
is not adjusted. For applications requiring the normally open circuit as the reference circuit, the
N.C. circuit is not adjusted.
Specify: 1. Set point 2. Actuate on increasing or decreasing pressure 3. SPST N.O. or N.C. SPDT.

7

Direct action blade
contact
Silver alloy, gold plated
Factory set
200-1000 PSI

15 AMP6 VDC
8 AMP- 12 VDC
4 AMP- 24 VDC
Inductive:
1 AMP- 120 VAC
0.5 AMP- 240 VAC
Standard Seal: Nitrile
(others available)
Temperature
Range:
-40° F to + 250° F
Connector:
1/2-20 UNF
(o-ring fitting)
Terminals:
#8-32 screws,
1/4” blade,
280 Series Metri-Pack
Circuitry:
SPST-N.O., N.C., D.C.
Base:
Steel
Cover:
Glass reinforced
polyester
Options:
Brass, stainless steel
base; o-ring fittings;
seal for brake fluid;
wire leads (potted and
sealed); boot p/n
79380 (see photo on
page 4.)

Set Points from 2 to 70 psi and 2” to 22” Hg

Series III Factory Set Variable Differential Pressure & Vacuum Switches With Snap Action Contacts

The Series III switch is a customizable
switch built per customer specifications.
It features a non-ferrous chamber
and excellent set point integrity at
extreme temperatures. The exclusive
snap switch features: Low-contact
resistance, wiping action, fast transfer
time, gold over silver contacts, and
an adjustable differential. It’s been
thoroughly tested for shock and
vibration resistance and is particularly
valuable in applications where
hysteresis, fast transfer time, and low
contact resistance are vital.

Vacuum Switch
Standard Specifications
Type:
Set Point:
Vacuum:

2.5” REF.

Snap action switch
Factory set
2 to 22” Hg
15 to 36” H2O

Operating
Pressure:
200 PSI
Proof Pressure: 350 PSI
Burst Pressure: 500 PSI
Ratings:
Resistive:

Pressure Switch
Standard Specifications
Type:
Set Point:
Pressure:
Operating
Pressure:
Proof Pressure:
Burst Pressure:
Ratings:
Resistive:

Inductive:

Diaphragm:
Temperature
Range:
Connector:
Terminals:
Circuitry:
Base:
Housing:
Options:
Terminations:

Connectors:

1.69” REF.

Snap action switch
Factory set
1-70 PSI
200 PSI
350 PSI
500 PSI
15 AMP6
8 AMP- 12
4 AMP- 24
1 AMP- 120
0.5 AMP- 240
Dry circuits

VDC
VDC
VDC
VAC
VAC

Beryllium copper
-40° F to + 250° F
1/8 -27 PTF SAE short
male thread
8” Wire leads-18 ga.
SPST-N.O. or N.C.,
SPDT
Brass
Die cast zinc
Silver contacts,
silver soldered base
Wire leads with wide
selection of Cannon,
Packard, AMP, and
others available
1/4” and 3/8” PTF
SAE short; 1/2-20
UNF (o-ring fitting);
3/8-24 UNF (3/16”
tube); 7/16-24 UNF
(1/4” tube); and metric

Series III
Pressure Switch

Inductive:

(Vacuum Switch Similar)

Series III pressure and vacuum switches are custom built
switches designed to customer specifications therefore
minimum ship quantitities are required and are not
available off-the-shelf.

Pressure Switch/Factory Set
Reference #
120000
120001
120002
120003
120004

Set Point Range Differential
2-4 PSI
4-12 PSI
12-24 PSI
24-40 PSI
40-70 PSI

1-1.5 PSI
2-6 PSI
8-12 PSI
10-18 PSI
15-20 PSI

Vacuum Switch/Factory Set
Reference # Set Point Range Differential
4-12” H2O
15-36” H2O
120005
0.4-1” Hg
2-6” Hg
120006
120007
0.4-1” Hg
6-12” Hg
120008
0.6-1.5” Hg
12-22” Hg
Specify:1. Set Point
2. Actuate on increasing or decreasing pressure
3. SPST N.O. or N.C., SPDT

8

Diaphragm:
Temperature
Range:
Connector:
Terminals:
Circuitry:
Base:
Housing:
Options:

15
8
4
1
0.5
Dry

AMP6 VDC
AMP12 VDC
AMP24 VDC
AMP- 120 VAC
AMP- 240 VAC
circuits

Silicone rubber
-40° F to + 250° F
1/8 -27 PTF SAE
short male thread
8” Wire leads-18 ga.
SPST-N.O. or N.C., SPDT
Brass
Die cast zinc
Silver contacts, silver

soldered base,
fluorosilicone rubber
diaphragm
Terminations: Wire leads with wide
selection of Cannon,
Packard, AMP, and others
available
Connectors: 1/4” and 3/8” PTF SAE
short; 1/2-20 UNF
(o-ring fitting);
3/8-24 UNF (3/16” tube);
7/16-24 UNF (1/4” tube);
and Metric

Set Points from 35 to 3000 psi

Series V High Pressure Environmentally Sealed, Extreme-Duty Switches With Snap Action Contacts

The Series V switch is a high pressure
switch with set points up to 3000 PSI and
is built to exact customer specifications.
Excellent set point integrity at extreme
temperatures and wide fluid compatibility
make this switch ideal for extreme duty
applications. And, under all operating
conditions, it boasts an excellent response
time. Like the Series III, the Series V
3.19” REF.
exclusive snap switch has an adjustable
differential, low contact resistance, wiping
action, fast transfer time, and gold over
silver contacts. This switch is beneficial
where hysteresis, fast transfer time, and low
contact resistance are vital.
Standard Specifications
Type:
Snap action switch
Set Point:
Factory set
Pressure:
35-300 PSI (elastomeric
diaphragm)
100-3000 PSI (steel
piston)
Operating
Pressure:
Diaphragm 300 PSI
Piston 3000 PSI
Proof:
Diaphragm 500 PSI
Piston 5000 PSI
Burst:
Diaphragm 2000 PSI
Piston 10000 PSI
Ratings:
Resistive:
Inductive:

Temperature
Range:
Connector:
Piston:
Terminals:
Circuitry:
Base:
Housing:
Options:
Terminations:
Connectors:

15 AMP6
8 AMP- 12
4 AMP- 24
1 AMP- 120
0.5 AMP- 240
Dry circuits

VDC
VDC
VDC
VAC
VAC

3.34” REF.

1.187” REF.

1.187” REF.

Diaphragm Type

Piston Type

Diaphragm Type
Reference Number Set Point Range Differential
26900
26901
26902
26903

35-50 PSI
50-100 PSI
100-200 PSI
200-300 PSI

10-15
10-15
10-15
10-20

PSI
PSI
PSI
PSI

Piston Type
-40°F to +250°F
Reference Number Set Point Range Differential
Diaphragm 1/8-27 PTF
35-50 PSI
26904
100-150 PSI
SAE short male thread
50-75 PSI
26905
150-250 PSI
3/4-16 UNF (o-ring fitting)
75-100 PSI
26906
250-500 PSI
8” Wire leads-18 ga.
26907
500-750 PSI 100-150 PSI
SPST-N.O. or N.C., SPDT
26908
750-1000 PSI 150-300 PSI
Plated steel
26909
1000-1250 PSI 175-350 PSI
Plated steel
26910
1250-1500 PSI 175-360 PSI
Silver contacts
26911
1500-1750 PSI 220-370 PSI
Wide selection of
26912
1750-2000 PSI 230-380 PSI
Cannon, Packard, AMP,
26913
2000-2250 PSI 250-390 PSI
and others available
26914
2250-2500 PSI 355-400 PSI
1/2-20 UNF (o-ring fitting);
26915
2500-2750 PSI 370-420 PSI
9/16-18 UNF (o-ring
26916
2750-3000 PSI 385-450 PSI
fitting);
M14x1.5 (o-ring fitting);
Others available
upon request.

9

Specify:1. Set Point
2. Actuate on increasing
or decreasing pressure
3. SPST N.O. or N.C.,
SPDT

Series V pressure and vacuum switches
are custom built switches designed
to customer specifications therefore
minimum ship quantitities are required
and are not available off-the-shelf.

Switch Definitions and Terminology
Pressure/Vacuum Switch - A device
that senses a change in pressure/
vacuum and opens or closes an
electrical circuit when the set point is
reached.
Set Point - The pre-determined
pressure/vacuum value that is required
to open or close the electrical contacts
in the switch.
Electrical Contacts - The elements
in the switch that electrically respond
to the media applied to the actuator.
Snap action contacts with a
“self-cleaning” wiping effect are used
in Series III and Series V switches.
Direct action blade contacts are used
in the 5000 Series.
Pressure Switch Actuator - The
member in the switch which receives
the media and ultimately strokes the
electrical contacts to open or close at
the designated set point. The actuator
in the Series III is a beryllium copper
or silicone rubber diaphragm. An
elastomeric diaphragm or piston
actuator is used in the Series V.
The 5000 Series uses a polyimide
film diaphragm.
Normally Open (SPST-N.O.) - A
normally open switch does not conduct
an electrical signal until the actuator
is moved by the media causing the
contacts to close.
Normally Closed (SPST-N.C.)
- A normally closed switch conducts
electricity until the actuator is moved
by the media causing the contacts to
open.
Dual Circuit (SPDT) - A normally
open and normally closed circuit are
contained in a switch.
Dual Circuit (N.O./N.O.) - Switch
contains two normally open circuits.

System Pressure/Vacuum - This is
the normal pressure/vacuum that would
be present at the switch actuator. This
value is important in order to apply
the proper switch configuration. Even
though the set point may be relatively
low, the system pressure would continue
to be applied to the switch actuator in
most cases.
Proof Pressure - This specification is
the maximum over-pressure condition
that the switch can have for a specified
period of time and still maintain set
point integrity.
Burst Pressure - This specification is
the maximum over pressure condition
that the switch can withstand without
experiencing leakage.
Dry Circuit Load - Typically this would
be a very low electrical load associated
with microprocessors when the open
circuit voltage is .03V or less and the
current is 40mA or less.
Resistive Load - A load in which the
voltage is in phase with the current.
Inductive Load - A load in which the
voltage leads the current.
Motor Load - The load of a motor at
rated horsepower and speed.
Capacitive Load - A load which the
current leads the voltage.
Differential - The difference between
opening (actuation) pressure and the
closing (de-actuation) set points. This
is also referred to as “dead band”. For
example, a switch set at 150 PSI to
open on increasing pressure and close
at 95 PSI on decreasing pressure
would have a differential of 55 PSI
(150-95=55).

Dual Circuit (N.C./N.C.) - Switch
contains two normally closed circuits.

10

Conversion Factors
Convert

To

Multiply By

kPa
PSI
BARS
PSI
Hg”
PSI
H2O”
PSI
H2O”
Hg”
C°
F°

PSI
kPa
PSI
BARS
PSI
Hg”
PSI
H2O”
Hg”
H2O”
F°
C°

.145
6.8948
14.5
.069
.4912
2.036
.03613
27.6778
.07355
13.5962
1.8(C° +17.78)
F-32÷1.8

Honeywell's Springfield and Spring Valley, Illinois facilities manufacture a broad range of electro and electronicmechanical products that include Hobbs hour meters, pressure and vacuum switches, off-highway vehicular lighting,
transmission shifters, turn signal controls, rotary switches, and off-highway vehicular hand controls. Honeywell's customer
base is very broad including industries such as automotive, agricultural, material handling, construction, marine, medical,
heavy truck, lawn and garden, recreational, generators, compressors and aviation. Our commitment to continuous
improvement and total quality management will allow for further expansion of its product lines and customer base while
maintaining the highest standards of excellence.

MANUFACTURING
Honeywell's commitment to the customer in past years
and present is what has helped us develop our
world-class manufacturing systems. Some of the methods
by which we continuously improve products and processes
are as follows:
Six Sigma methodology is a strategy used to
accelerate improvements in our processes, products
and services, and to reduce manufacturing costs
and improve quality. It achieves this by relentlessly
focusing on eliminating waste and reducing defects
and variations.
Continuous Flow Process utilizing “Rabbit Chase”
concepts are used in the focused factories in order
to achieve the lowest total cost, defect-free product.
Single Minute Exchange of Dies (SMED method)
provides reduced time in the molding cell.
Statistical Process Control is used for measuring
critical dimensions and controlling manufacturing
processes.
Poka-Yoke method and computerized test
equipment are utilized to eliminate scrap and
rework.
Kanban cards are used to pull raw material and
piece parts through the factory.
Bar coding and electronic data interchange (EDI) are
available.

QUALITY SYSTEMS
It is the goal of Honeywell to meet customer value-needs
through continuously improved products and processes.
That is the basis by which we work to create a partnership
with our customers. Evidence of our commitment is proven
by a goal of a Shipped Product Quality Level (SPQL) of 100
ppm. We utilize Advanced Quality Planning, and a QS9000
based quality system.

11

Warranty/Remedy

Honeywell warrants goods of its manufacture as being free of
defective material and faulty workmanship. Contact your local
sales office for warranty information. If warranted goods are
returned to Honeywell during that period of coverage, Honeywell
will repair or replace without charge those items it finds
defective. The foregoing is Buyer’s sole remedy and is
in lieu of all other warranties, expressed or implied,
including those of merchantability and fitness for a
particular purpose.
While we provide application assistance, personally, through
our literature and the Honeywell web site, it is up to the customer
to determine the suitability of the product in the application.
Specifications may change at any time without notice. The
information we supply is believed to be accurate and reliable as
of this printing. However, we assume no responsibility for its use.

Sensing and Control
Honeywell
P.O. Box 19424
Springfield, IL 62794-9424
USA
email: www.honeywellhobbs.marketing@honeywell.com
Catalog 10-1003, GLO Printed in the U.S.A.

© 2004 Honeywell International Inc. All Rights Reserved.

Sales and Service

Honeywell serves its customers through a worldwide
network of sales offices and distributors. For application
assistance, current specifications, pricing or name of the
nearest Authorized Distributor, contact your local sales
office or:
INTERNET: www.honeywell.com/hobbs
E-mail: honeywellhobbs.marketing@honeywell.com
For Honeywell pressure and vacuum switches
contact the Springfield location at
217-753-7798 or visit
www.honeywell.com/hobbs

www.honeywell.com/hobbs



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 12
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:cefbca92-7202-11d8-b3c6-000a95961238
Create Date                     : 2004:03:09 13:44:50Z
Metadata Date                   : 2004:03:09 13:48:59-06:00
Modify Date                     : 2004:03:09 13:48:59-06:00
Creator Tool                    : Adobe InDesign CS (3.0)
Rendition Class                 : proof:pdf
Document ID                     : adobe:docid:indd:cb62c95b-735a-11d8-8ee4-f103ca91f682
Derived From Instance ID        : cb62c957-735a-11d8-8ee4-f103ca91f682
Derived From Document ID        : adobe:docid:indd:66df766a-56ff-11d8-be05-f5e7016473a8
Manifest Link Form              : ReferenceStream, ReferenceStream
Manifest Reference Instance ID  : uuid:abda0e3a-7033-11d8-b5e4-fb32818dce01, uuid:d302e089-7033-11d8-b5e4-fb32818dce01
Manifest Reference Document ID  : adobe:docid:photoshop:abda0e39-7033-11d8-b5e4-fb32818dce01, adobe:docid:photoshop:d302e088-7033-11d8-b5e4-fb32818dce01
Format                          : application/pdf
Title                           : 230642Final Switch Catalog .indd
Tagged PDF                      : Yes
Trapped                         : False
Creator                         : Adobe InDesign CS (3.0)
Producer                        : Adobe PDF Library 6.0
EXIF Metadata provided by EXIF.tools

Navigation menu