Honeywell V4055 Users Manual 60 2309—12 V4055A,B,D,E On Off Fluid Power Gas Valve Actuator
V4055 to the manual 7342bce4-285a-4839-9a54-821089bbbb8e
2015-01-23
: Honeywell Honeywell-V4055-Users-Manual-261123 honeywell-v4055-users-manual-261123 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
V4055A,B,D,E On-Off Fluid Power Gas Valve Actuator PRODUCT DATA • The V4055 Actuator can be used with the characterized guide model of the V5055 or V5097 Gas Valve to enhance lightoff smoothness. • The standard model has an opening time of 26 seconds at 60 Hz or 32 seconds at 50 Hz. A fastopening model is available with timings of 13 seconds at 60 Hz or 16 seconds at 50 Hz. • Maximum closing time is one second, which meets code, standard and insurer requirements. • Models available with damper shaft, with or without spring return; shaft extends out both sides and rides in Teflon-like Delrin bushings; used with standard 7616BR Damper Crank Arm. • Red OPEN indicator attached to actuator stem shows when valve is even slightly open; yellow SHUT indicator on valve stem shows only when gas valve is fully closed. • Models available with adjustable max flow limit switch. APPLICATION The V4055 Gas Valve Actuator, in combination with a VE5000a, V5055 or V5097 Gas Valve, controls the gas supply to commercial and industrial burners. When replacing a V4034 with a V4055, the V5034 gas valve must also be replaced with a V5055 or V5097 gas valve. FEATURES • The V4055 Actuator, when used with the VE5000a, V5097 or V5055 Valve, is rated for final safety shutoff service. • Ambient temperature rating is -40°F to +150°F (-40°C to +66°C) for 60 Hz models and -10°F to +158°F (-23°C to +70°C) for 50 Hz and 50/60 Hz models. • Valve and actuator combinations can be mounted in any position, with the exception of the 220 to 240 Vac, 50/60 Hz models, which are mounted vertically. • Models available with factory-installed single pole double throw (spdt) field-adjustable Auxiliary Switch. Field-addable Auxiliary Switch kits are also available. • Standard enclosure meets NEMA 1 (IP30) requirements; models available with NEMA 4 (IP54) weatherproof enclosure. • V4055D and high pressure V4055E with Proof-ofClosure Switch and V5055/V5097C or E with valve seal overtravel interlock (double seal) to meet specific code, standard and insurer requirements. a VE5000 is a European manufactured and approved valve for European use only. Contents Application ........................................................................ Features ........................................................................... Specifications ................................................................... Ordering Information ........................................................ Installation ........................................................................ Wiring ............................................................................... Checkout and Service ...................................................... 60-2309-13 1 1 2 2 4 6 7 V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR SPECIFICATIONS Table 1. Nominal Opening Time (seconds). Models: V4055A Actuator, with V5055, V5097 or VE5000 Gas Valves, provides on-off control of fuel. With proper adapter (see Accessories), it replaces the V4034 Actuator on a V5034 Gas Valve. V4055B Actuator is a high pressure version of V4055A. V4055D Actuator is identical to V4055A, except has a Proof-of-Closure Switch. Used with V5055C/V5097C (double seal) for valve seal overtravel interlock. V4055E Actuator is identical to V4055B, except has a Proof-of-Closure Switch. Used with V5055E/V5097E (double seal) for valve seal overtravel interlock. NEMA 4 weatherproof models available. Model 50 Hz 60 Hz Standard 32 26 Fast-opening 16 13 Maximum Closing Time: One second when de-energized. Ambient Operating Temperature Ratings: 60 Hz Models: -40°F to +150°F (-40°C to +66°C). 50 Hz, 50/60 Hz Models: -10°F to +158°F (-23°C to +70°C). Mounting: V4055 Actuator attaches directly to V5055/V5097 Valve with two sets of screws positioned 90 degrees apart. Combination is multipoise. Nominal Opening Time: See Table 1. NOTE: 220 to 240 Vac, 50/60 Hz models are vertical mount only. Pressure Ratings: See Table 2. Table 2. Pressure Ratings of Valve-Actuator Combinations. STANDARD PRESSURE ACTUATORS V4O55A, D, F, G Model STANDARD PRESSURE VALVES V5055A, B, C, F, V5097A, B, C HIGH PRESSURE VALVES V5055D, E, V5097D, E Max. Rated Pressureb M.O.P.D.a Pipe Size HIGH PRESSURE ACTUATORS V4O55B, E M.O.P.D.a Max. Rated Pressure b 3/4” to 1-1/2”c 5 PSI 340 mbar 15 PSI 1.0 Bar 15 PSI 1030 mbar 15 PSI 1.0 Bar 2” to 3”d 5 PSI 340 mbar 15 PSI 1.0 Bar 15 PSI 1030 mbar 15 PSI 1.0 Bar 3 PSI 207 mbar 15 PSI 1.0 Bar 5 PSI 340 mbar 15 PSI 1.0 Bar 5 PSI 340 mbar 75 PSI 5.0 Bar 25 PSI 1720 mbar 75 PSI 5.0 Bar 5 PSI 340 mbar 45 PSI 3.0 Bar 15 PSI 1030 mbar 45 PSI 3.0 Bar e 4” flanged 3/4” to 1-1/2” c 2” to 3”d a Max Operating Pressure Differential (UL) or Max Operating Pressure (CSA): maximum allowable pressure drop from inlet to outlet for proper operation . b Max rated pressure (UL) or Max Close-off Pressure (CSA) : maximum pressure that the valve can be exposed to without leakage or damage to the valve. c Applies for small-body V5097 valves 3/4” up to 2” pipe size. d Applies for large-body V5097 valves 2” up to 3” pipe size. e V5055A, B, C only. Electrical Ratings: See Tables 3 and 4. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 60-2309—13 2 V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR Table 3. V4055A,D Electrical Ratings. Opening (Standard) Voltage and Frequency Inrush (W) (A) Opening (Fast) VA) Inrush (W) Holding (A) (VA) (W) (A) (VA) 100/50-60a — 43.0 0.91 91 — 58.0 1.30 130 10.4 0.16 16 100/50-60b — 33.0 0.6 67 — 43.0 0.91 91 8.4 0.14 14 120/60 3.9 50.0 0.94 115 5.4 71.0 1.33 160 9.5 0.12 14 a — 68.0 0.79 158 — 88.0 1.10 220 10.6 0.09 18 200/50-60b — 48.0 0.52 104 — 63.0 0.72 144 9.0 0.07 14 220/50 1.6 55.5 0.55 121 3.0 76.0 0.80 176 9.0 0.06 14 240/50 — 81.5 0.79 190 — 95.0 1.00 240 9.1 0.06 14 240/60 2.6 51.0 0.45 115 4.0 71.5 0.68 160 9.2 0.06 14 220-240/50-60c — — — — — 70.3 0.59 136 7.2 0.07 16 220-240/50-60d — — — — — 58.6 0.46 106 5.9 0.06 14 200/50-60 a 50 Hz power supply. 60 Hz power supply. c 230 Vac, 50 Hz power supply. d 230 Vac, 60 Hz power supply. b Table 4. V4055B,E Electrical Ratings. Voltage and Frequency Opening (Standard) Inrush (W) (A) Opening (Fast) (VA) Inrush (W) Holding (A) (VA) (W) (A) (VA) 120/60 — 60 0.94 115 — 60.0 0.94 115 9.5 0.16 19 220-240/50-60a — — — — — 68.9 0.58 133 6.7 0.08 18 220-240/50-60b — — — — — 58.2 0.46 106 5.3 0.06 14 a b 230 Vac, 50 Hz power supply. 230 Vac, 60 Hz power supply. Auxiliary Switch and Proof-of-Closure Switch Ratings: See Table 5. NOTE: Damper shaft drives damper crank arm in one direction only; optional return spring is available on damper shaft to turn damper crank arm in opposite direction. See Table 6. Table 5. Auxiliary Switch and Proof-of-Closure Switch Ratings (1/2 hp [0.37kW]a). Load 120V Full Load 9.8A 4.9A Locked Rotor 58.8A 29.4A aMaximum 1800 VA. Table 6. Actuator Torque (With and Without Return Spring). 240V -40°F to +20°F (-40°C to -7°C) lb V4055 Model total connected power to both switches (if used) is With return spring 20°F to 150°F (-7°C to +66°C) N lb N 5 22.2 10 44.5 Mounting Dimensions: See Fig. 1 and Table 7. Without return spring 5 22.2 20 89.0 Damper Shaft: Shaft is 3/8 in. (9.5 mm) square, for use with 7616BR Damper Crank Arm (ordered separately) and with or without damper shaft return spring. Approvals: Underwriters Laboratories Inc. Listed: File No. MH1639, Guide No. YIOZ. Factory Mutual: Listed. Canadian Standards Association certified: General Listed file numbers 158158 Class 3371 For U.S.A. and Canada: certified 60 Hz models only. Swiss Re (Formerly GeGap/IRI) Acceptable. Some V4055 Actuators are approved as Class A valves in accordance with EN161: When used with V5055 Valves: Pin: CE-0063AR1359. When used with VE5000 Series Valves: Pin: CE0063AP3075. Maximum Damper Shaft Rotation: 52 angular degrees. Maximum Force: 2-11/16 in. (68.3 mm) radius for 7616BR Damper Crank Arm ordered separately (see Accessories section). 3 60-2309—13 V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR Accessories: 133568 Auxiliary Switch Bag Assembly (not for models with maximum flow limit switch). 133569 Valve-Closed Indication Switch Bag Assembly. 7616BR Damper Crank Arm (damper arm and clip). Available Models: V4055 with NEMA 4 enclosure (weatherproof). NOTE: Check local codes for acceptance of adding the switch and using the valve seal overtravel V5055C or V5055E valves. 6-3/4 (172) KNOCKOUT FOR 1/2 INCH CONDUIT (4) 3-23/32 (95) 5 (127) 27/32 (21) 1-9/32 (33) 1 A C B VALVE VALVE D 1 ALLOW 4 INCH (102 MM) CLEARANCE FOR ACTUATOR REMOVAL. M17755A Fig. 1. Approximate mounting dimensions of V4055 Actuators in in. (mm). Table 7. Approximate Mounting Dimensions of V4055 Actuators with V5055 and V5097 Valves. V5055 Dim. A Valve Sizea (in.) Small Body Large Body a in. Dim. B mm in. mm V5097 Dim. C in. mm Dim. D in. Dim. A mm in. Dim. B mm in. Dim. C mm in. Dim. D mm in. mm 3/4 11-1/8 283 2-3/4 70 8-3/16 208 5-3/4 146 11-1/8 283 2-3/4 70 8-3/16 208 2-1/2 64 1 11-1/8 283 2-3/4 70 8-3/16 208 5-3/4 146 11-1/8 283 2-3/4 70 8-3/16 208 2-/12 64 1-1/4 11-1/8 283 2-3/4 70 8-3/16 208 5-3/4 146 11-1/8 283 2-3/4 70 8-3/16 208 2-1/2 64 1-1/2 11-1/8 283 2-3/4 70 8-3/16 208 5-3/4 146 11-1/8 283 2-3/4 70 8-3/16 208 2-1/2 64 2 11-1/8 286 2-7/8 73 8-5/16 211 8-3/8 213 11-3/4 298 3-3/8 86 8-3/8 213 4 102 102 2 11-3/4 298 3-3/8 86 8-13/16 224 9-1/4 235 1-3/4 298 3-3/8 86 8-3/8 213 4 2-1/2 11-3/4 298 3-3/8 86 8-13/16 224 9-1/4 235 11-3/4 298 3-3/8 86 8-3/8 213 4 102 3 11-3/4 298 3-3/8 86 8-13/16 224 9-1/4 235 11-3/4 298 3-3/8 86 8-3/8 213 4 102 4 14-1/8 359 5-13/16 148 11-7/32 285 12-1/2 318 — — — — — — — — Valve size using accessory pipe adapter fitting. INSTALLATION 3. 4. When Installing This Product... 1. 2. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 60-2309—13 Installer must be a trained, experienced flame safeguard control technician. After installation is complete, check out product operation as provided in these instructions. WARNING Electrical Shock Hazard. Can cause serious injury or death. Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. 4 V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR Mount Actuator on Valve IMPORTANT 1. All wiring must comply with all applicable electrical codes, ordinances, and regulations. All wiring must be NEC Class 1. 2. Voltage and frequency of the power supply connected to this control must agree with those marked on the device. 3. Loads connected to the Auxiliary Switch and/or Proofof-Closure Switch, if used, must not exceed the ratings given in the Specifications section. 1. 2. Check the final position of the valve body to be sure that the actuator is in the proper position when mounted on the valve. This is especially important when the actuator is used to drive a damper. If two smaller sized valves are mounted very closely together, as in an Industrial Risk Insurers approved type of valve train, it may be necessary to mount the actuators off center to provide adequate clearance. Install Valve The actuator is mounted directly on the valve bonnet after the valve is installed in the gas supply line. Refer to the instructions packed with the gas valve for installation details. When installing the gas valve, make sure: 1. 2. 3. 133568 AUXILIARY SWITCH Sufficient clearance is left to install and service the actuator. Ambient temperatures at the valve location do not exceed actuator ratings. See Specifications section. Position of the valve permits hookup to the damper if one is controlled. 133569 VALVECLOSED INDICATION SWITCH Install Accessory Switches (If Needed) ADJUSTING SCREW FOR AUXILIARY SWITCH An spdt switch can be installed to operate an auxiliary load up to 1/2 hp (0.37 kW). See Table 5. The switch can be adjusted to operate at any point in the valve stroke. A Proof-of-Closure Switch can also be installed with a V5055/ V5097C or E Valve (with double seal) on any V4055 Actuator to provide a valve seal overtravel interlock. The spdt Proof-of-Closure Switch is installed to make or break a circuit when the valve is in the closed position. The switch is not adjustable. EACH SWITCH SECURED BY TWO SCREWS FROM UNDERSIDE OF BASE. IF ONLY ONE SWITCH IS USED, INSTALL BARRIER IN OPEN POSITION. Fig. 2. V4055 Actuator with cover removed. 3. NOTE: Mark the actuator or valve to indicate any changes made. To install the switches: 1. 2. 3. 4. 5. 6. M7326B 4. Remove the actuator faceplate (two screws). Remove the silver-colored barrier to expose the actuator stem. Insert the Auxiliary Switch in the position indicated in Fig. 2. Fasten with two screws through the actuator base. Insert the Proof-of-Closure Switch in the position shown in Fig. 2. The switch mounts against the side of the actuator housing. The mounting holes are spaced to assure mounting the switch in the correct position. Fasten with two screws through the actuator base. (The Proof-of-Closure Switch is not adjustable.) If only one switch is used, install the narrow barrier included with the switch in the unused space. Mount the actuator before making wiring connections and adjustments to the Auxiliary Switch. Slip the bottom collar of the actuator over the valve bonnet assembly. Rotate the actuator to the desired position and use a 5/32 in. Allen wrench to securely tighten the two setscrews to 50 to 60 lb-in. (5.7 to 6.8 N•m). Connect the damper linkage, if used. Refer to the instructions packed with the damper arm. Mount and Adjust 7616BR Damper Crank Arm (If Used) IMPORTANT When a damper crank arm is used with a NEMA 4 actuator that is exposed to ice or sleet, a suitable shield must be installed to prevent ice or sleet buildup. Follow installation and adjustment directions included with damper crank arm. Maximum pushrod travel is 2-5/16 in. (59 mm) through a stroke of 52 degrees. See Fig. 3. 5 60-2309—13 V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR stroke. L1 HOT 1 7616BR DAMPER ARM 52 DEGREE ANGULAR ROTATION 2-5/16 (58.7) MAXIMUM TRAVEL 2 1 L2 SHAFT PROOF-OF-CLOSURE SWITCH AUXILIARY SWITCH 2-11/16 (68.3) RADIUS M7322 Fig. 3. 7616BR Damper Crank Arm can be attached to actuator shaft to drive a damper when valve is open. WIRING C C NC NC NO NO 2 2 3 WARNING Electrical Shock Hazard. Can cause serious injury or death. Disconnect power supply before making wiring connections to prevent electrical shock and equipment damage. Wiring must comply with all applicable electrical codes, ordinances and regulations. Wiring to the actuator must be NEC Class 1. 1 POWER SUPPLY. PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED. 2 SWITCH BETWEEN THESE TWO LEADS IS CLOSED WHEN VALVE IS SHUT (DE-ENERGIZED). 3 SWITCH BETWEEN THESE TWO LEADS IS OPEN WHEN VALVE IS SHUT (DE-ENERGIZED). M7334 Fig. 4. External connections to the V4055 Actuator. 7800 SERIES RELAY MODULE L2 Connect the power supply to terminals 1 and 2 on the V4055 terminal strip. Refer to Fig. 4 for Auxiliary Switch connections and Fig. 5 for Max Flow Limit Switch connections. For typical system hookups, refer to Fig. 6 and to instructions packed with the device used to control the valve. 9 1 3 When all wiring connections are complete, replace the actuator faceplate. 2 4 TRAVEL LIMIT SWITCH CAUTION Operation Hazard. Improper wiring can cause improper and dangerous operation. Label all wires prior to disconnection when servicing valves. Wiring errors can cause improper and dangerous operation. FIELD WIRING INTERNAL WIRING PUMP VALVE PUMP MOTOR ADJUSTABLE NO MAX FLOW NC LIMIT SWITCH C M12798 Fig. 5. Connecting the Max Flow Limit Switch to the actuator. NOTE: The Proof-of-Closure Switch is not adjustable. NOTE: Pipe sealant is required on the conduit threads of actuators with NEMA 4 enclosures. Adjust Max Flow Limit Switch (If Used) Adjust Auxiliary Switch (If Used) The Max Flow Limit Switch is adjustable throughout the stroke of the actuator. With the switch installed in the actuator, turn the adjusting screw clockwise to cause the switch to operate earlier in the stroke or counter-clockwise to cause the switch to operate later in the stroke. The Auxiliary Switch is adjustable throughout the stroke of the actuator. With the switch installed in the actuator, turn the adjusting screw (see Fig. 2) clockwise to cause the switch to operate earlier in the stroke or counterclockwise to cause the switch to operate later in the 60-2309—13 3 6 V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR CHECKOUT AND SERVICE 7. 8. CAUTION 9. Equipment Damage Hazard. Unskilled technicians can cause equipment damage. Only a trained, experienced, flame safeguard technician should check out and service this control. 10. Checkout NOTE: When replacing the bonnet assembly on the 4inch valve, draw it evenly into the valve body. Finger-tighten the eight bolts. Draw the bonnet assembly into the valve by tightening, in order, bolts 1, 5, 7 and 3 (two turns each). Repeat until the bonnet assembly is seated. Tighten the remaining bolts. Torque the bolts as follows: After the installation is complete, cycle the valve several times with the manual fuel shutoff cock closed before testing the system in actual operation. Service The actuator is not field repairable except for replacing the Auxiliary Switch, Max Flow Limit Switch or Proof-of-Closure Switch. See Installation section for procedure. Do not disassemble the valve actuator. Valve Size If the actuator fails to operate properly, replace it. 1. 2. 3. 4. 5. Turn off the gas supply at the manual shutoff valve located upstream from the valve(s) being serviced. Shut off all electrical power to the valve actuator(s). Mark and disconnect the wires from the actuator terminals. Remove conduit and disengage the damper linkage assembly (if applicable). Loosen the two set screws from the valve to lift off the actuator. If the actuator is to be replaced and it did not leak hydraulic fluid, skip to Step 11. NOTE: 6. If the valve bonnet assembly is in good condition and is not replaced, replace the bonnet seal. Do not reuse the old bonnet seal. See Table 9 below for the seal number. Coat seals with grease provided and position in valve body/bonnet assembly. Carefully seat the bonnet assembly on the valve body. Be sure the seals are in their proper position. On those valves with a spring below the disc, be sure the spring is centered in the indentation on the inside of the valve body. After positioning the bonnet assembly, replace the screws removed earlier. Torque 3/4 in. (19 mm) to 1-1/2 in. (38 mm) 55 in.-lb. 2 in. (51 mm) to 4 in. (102 mm) 75 in.-lb. 11. 12. 13. 14. Remount the actuator on the bonnet assembly. Tighten the two set screws (50-60 inch pounds). Replace the damper crank arm assembly. Re-attach the wires removed from the actuator terminals and turn on the electrical power. With the gas still off, cycle the actuator to check for proper mechanical operation. CAUTION It is good practice to inspect the inside of the valve whenever the actuator is replaced. To do so, remove the bonnet assembly, inspect the valve and bonnet. If all is well, proceed to Step 7. Be sure to perform a bonnet seal and seat leak check after installation. Be sure to read and follow all instructions that come with the actuators, valves, seal and bonnet kits. If the actuator leaked hydraulic fluid onto the valve (the fluid is red), it must be cleaned off from the valve and bonnet assembly. a. Wipe off the outer valve body. b. Remove the valve bonnet bolts and lift off the bonnet. Table 8. Replacement Bonnets for V5055/V5097 Gas Valves. Replacement Bonnet NOTE: V5055/V5097C and E Valves have additional internal springs that will push the bonnet up as the bolts are loosened. 133398AA Valve V5055A V5097A 133417AA c. Inspect the inside of the valve. 2, 2-1/2, 3 136911AA (On-Off) 133398BA V5055B 4 V5097B IMPORTANT If fluid is present on the inside surfaces of the valve body or bonnet surfaces, the bonnet assembly or entire valve must be replaced. See Table 8 below for the bonnet assembly part number. 133417BA d. If the inside surfaces are clear of hydraulic fluid, clean the bonnet assembly and be sure to remove all hydraulic fluid from the inside and outside of the actuator mounting curb. This is the “cup-like” area around the valve stem. Avoid using a cleaning solution as it may damage the rubber seals used in the valve. 136911CA (Proof of Closure) 136308AA V5055D 3/4, 1, 1-1/4, 1-1/2 2, 2-1/2, 3 136911BA (Characterized Guide) 4 133398CA V5055C 3/4, 1, 1-1/4, 1-1/2 V5097C 133417CA 2, 2-1/2, 3 V5097D 136307AA 136308BA 136307BA 7 Valve Size (in in.) 3/4, 1, 1-1/4, 1-1/2 4 3/4, 1, 1-1/4, 1-1/2 2, 2-1/2, 3 V5055E V5097E 3/4, 1, 1-1/4, 1-1/2 2, 2-1/2, 3 60-2309—13 V4055A,B,D,E ON-OFF FLUID POWER GAS VALVE ACTUATOR Each replacement assembly contains the bonnet assembly, two rubber seals, and a tube of grease. It must be used only on the type of valve indicated above. Table 9. Gas Valve Replacement Seals. Replacement Seal Assy # 133393A Valve Size (in in.) 3/4, 1, 1-1/4, 1-1/2 133392A 2, 2-1/2, 3 137253A 4 WIRING SUBBASE TERMINAL STRIP (4) R414OL FLAME SAFEGAURD CONTROLS LOCKOUT INTERLOCKS (INCL. AIRFLOW SWITCH) 2 3 V4055D OR E 1 BURNER CONTROLLER 4 LIMITS 2 L1 18 C 3 9 10 ALARM L2 10 SECOND INTERRUPTED PILOT/IGNITION 5 15 SECOND INTERRUPTED PILOT/IGNITION 6 NC NO 17 HIGH-FIRE 12 16 7 BURNER MOTOR 8 LOW-FIRE SWITCH 11 COMMON B B R R W W 13 ALTERNATE LOW-FIRE SWITCH 15 F 14 MODULATE LOW-FIRE 120V, 60 HZ POWER SUPPLY 1 RECTIFYING FLAME ROD, RECTIFYING PHOTOCELL, OR INFRARED (LEAD SULFIDE) FLAME DETECTOR OR BLUE SERIES 90 CONTROLLER G HIGH-FIRE SWITCH SERIES 90 FIRING RATE MOTOR L1 (HOT) BLUE L2 MASTER SWITCH C7027A, C7035A, OR C7044A, ULTRAVIOLET FLAME DETECTOR OR C7012A, C, E,F OR C7076A ULTRAVIOLET FLAME DETECTOR WHITE YELLOW WHITE 1 POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED. 2 USE ALL NEC CLASS 1 WIRING. 3 PROOF-OF-CLOSURE SWITCH IN PREIGNITION INTERLOCK CIRCUIT; SWITCH IS CLOSED NC-C WHEN ACTUATOR IS DE-ENERGIZED. WHITE L2 L1 L2 BLACK BLACK M7335 Fig. 6. Typical application of a V4055D/V5055C/V5097D or V4055E/V5055E/V5097E combination to meet Factory Mutual or Underwriters Laboratories Inc. approved requirements for Proof-of-Closure Switch (valve seal overtravel interlock). Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Toronto, Ontario M1V 4Z9 customer.honeywell.com ® U.S. Registered Trademark © 2010 Honeywell International Inc. 60-2309—13 E.K. Rev. 02-10 Printed in U.S.A.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Assemble, Print high-res Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Creator Tool : FrameMaker 7.0 Modify Date : 2010:02:24 08:03:38-06:00 Create Date : 1999:07:07 12:30:47Z Metadata Date : 2010:02:24 08:03:38-06:00 Format : application/pdf Title : 60-2309—12 - V4055A,B,D,E On-Off Fluid Power Gas Valve Actuator Creator : Honeywell ECC Technical Communications Description : Product Data Producer : Acrobat Distiller 8.2.0 (Windows) Document ID : uuid:9808e7dc-1439-4239-93a6-1875b24b778e Instance ID : uuid:8ea99814-3088-45ee-8abd-0e765dd56bf2 Page Count : 8 Subject : Product Data Author : Honeywell ECC Technical CommunicationsEXIF Metadata provided by EXIF.tools