Honeywell W8600F Users Manual 69 1200 2
W8600F to the manual a9bbfee9-0608-495b-860e-896542dec441
2015-01-23
: Honeywell Honeywell-W8600F-Users-Manual-261045 honeywell-w8600f-users-manual-261045 honeywell pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
69-1200-2.fm Page 1 Tuesday, December 3, 2002 11:21 AM W8600F Air Cleaner Monitor INSTALLATION INSTRUCTIONS APPLICATION LCD The W8600F Air Cleaner Monitor is an option available for use with the F50F and F52F Honeywell Electronic Air Cleaners (EAC). The series two F50F and F52F require a solid state power supply that is compatible with the W8600F driver board. Any series one F50E, F or F52F can be upgraded to use the W8600F when the power supply is replaced and the driver board (included in W8600F kit) is installed. ON BATTERY SERVICE FAULT Air Cleaner Monitor FUNCTION INDICATOR PANEL The W8600F function indicator panel has four liquid crystal display (LCD) arrowheads that point to ON, BATTERY, SERVICE or FAULT. See Fig. 1. The arrowheads darken to indicate the existing EAC condition. See Table 1. INSTALLATION RESET BUTTON M11965 When Installing this Product.. 1. 2. 3. 4. Fig. 1. W8600F Air Cleaner Monitor features. Read these instructions carefully. Failure to follow the instructions could damage the product or cause a hazardous condition. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application Installer must be a trained, experienced service technician. After completing the installation, use these instructions to check out the product operation. Table 1. Description of W8600F Function Indicator Panel. Indicators ON EAC is powered and system blower is running. BATTERY Battery that maintains W8600F memory is low and needs to be replaced. SERVICE EAC prefilter and cells need to be washeda. FAULT •Shorting of collector plates. •Continuous ionizer or collector plate arcing. •Power supply failure. •Excessive current. •Major reduction in high voltage. •EAC prefilter and cells are past SERVICE level of dirt and need to be washed immediately. Call a service technician. Location The styling of the W8600F is designed to blend with the latest T8600 family of Honeywell Chronotherm¨ IV Deluxe Programmable Thermostats. A special mounting template is included for mounting next to the T8600. The W8600F can also be mounted at any other convenient location in the living area or equipment room. See Fig. 2. NOTE: The W8600F shares no common electrical connections with the thermostat. a ® U.S. Registered Trademark Copyright © 2002 Honeywell International Inc. • Condition The reset button is located on the bottom of W8600F. After the prefilters and cells are cleaned and reinstalled, press this button to turn off the SERVICE indicator and reset the wash frequency timer. • All Rights Reserved 69-1200-2 69-1200-2.fm Page 2 Tuesday, December 3, 2002 11:21 AM W8600F AIR CLEANER MONITOR EAC W8600F On Battery Service Fault W8600F Air Clea ner Mon itor EAC RETURN AIR DUCT CEMENT BLOCK WALL EAC W8600F W8600F EAC W8600F EAC CLOSET GARAGE/DRYWALL F52-ATTIC M11966 Fig. 2. W8600F mounting locations. Mounting The following mounting instructions assume that the W8600F is mounted next to a T8600 Thermostat. If installing the monitor at another location, modify the procedure to fit the installation. 1. 2. 3. 4. 5. THERMOSTAT WALLPLATE Hold the mounting template (included in the W8600F kit) next to the T8600 as shown in Fig. 3. Mark the holes for the screw anchors and the 3-conductor thermostat cable. Remove the template and drill the holes. Remove the W8600F from the base. Position the W8600F base over the holes and install the anchors and screws (included in the bag assembly). Tighten the screws until the base is mounted firmly on the wall. 69-1200—2 MOUNTING TEMPLATE WIRING HOLE MOUNTING HOLES (2) Fig. 3. Positioning mounting template. 2 M11971 69-1200-2.fm Page 3 Tuesday, December 3, 2002 11:21 AM W8600F AIR CLEANER MONITOR Select Wash Frequency 3. Use the W8600F DIP switches to program the time between SERVICE indications. Be sure to select the setting according to the conditions of the home. Factors to consider include the duty cycle of the EAC, the number of people and pets, and activities such as woodworking and other crafts that are being done in the home. 4. 5. Check that the battery is correctly installed in the W8600F battery holder. Snap the W8600F onto the base. Turn off the power for the EAC. WARNING Electric Shock Hazard. Can cause electrical shock or equipment damage. Disconnect EAC power and open the access door before opening power supply box cover. Refer to Table 2 to select the wash frequency. Set the W8600F DIP switches to match the selection. See Fig. 4. The time listed represents actual run time of the EAC, not calendar days. 6. 7. Table 2. Wash Frequency Options. DIP Switch Settings Wash Frequency 1 2 3 Days (Run Time) Off Off Off 10 On Off Off 20 Open the power supply box cover. Remove the plug from the side of the power supply box (plug can be a metal knockout or a blank terminal strip). Install the terminal block/cable assembly supplied with W8600F kit. Plug the connector on the end of the cable assembly into the J2 terminal on the driver board (included with W8600F kit). See Fig. 5. 8. 9. Off On Off 30 On On Off 40 Off Off On 50 On Off On 70 Off On On 100 On On On 180 POWER SUPPLY BOX COVER ELEC TRON IC AI R CL EANE SYST R EM J2 DRIVER BOARD BACK OF W8600F TERMINAL STRIP BATTERY IN HOLDER J1 MOUNTING SCREW DIP SWITCHES POWER SUPPLY UP 123 POWER SUPPLY BOX WIRING TERMINALS (3) M11970 Fig. 5. Installing the driver board on the EAC. 1 10. 3 4 RESET BUTTON M11969A NOTE: This W8600F kit is configured to operate with a power supply that is controlled by an airflow switch (AFS). If your application does not have an AFS, place the black shorting bar (found in the bag assembly) on power supply connector J3, pins 1 and 2, as shown in Fig. 6. Fig. 4. Back of W8600F. Wiring 1. Run a 3 -conductor thermostat cable (up to 18 gauge) from the W8600F to the terminal strip on the air cleaner. SHORTING BAR J3 IMPORTANT Connect cable to W8600F before attaching to the air cleaner terminals to minimize the risk of damage due to static electricity. 2. Plug the driver board assembly into the J1 power supply connector. 4 3 2 1 M20890 Fig. 6. Placing shorting bar on power supply for applications without AFS. Connect the wires to terminals E1, E3 and E4 on the W8600F. See Fig. 4. 11. 3 Replace the power supply box cover. 69-1200—2 69-1200-2.fm Page 4 Tuesday, December 3, 2002 11:21 AM W8600F AIR CLEANER MONITOR 12. Connect the three wires from the W8600F to the EAC terminals 1, 3 and 4. 3. 4. NOTE: Connect terminal 1 to 1, 3 to 3 and 4 to 4. 13. Turn on the EAC power. 14. Turn on the system fan. 15. Push the W8600F reset button. All four indicators on the display will flash five times. The On indicator will stay active as long as the EAC and the system fan are on. Checkout (Without EAC) 1. 2. 3. SYSTEM CHECKOUT 4. Checkout (With EAC Running) 1. 2. Be sure the battery is installed in the W8600F. Press the reset button on bottom of the W8600F. All four indicatiors on the display will flash five times and then ON and FAULT will remain indicated. Connect terminal 3 to terminal 4 and the function panel indicates ON. FAULT will turn off. Disconnect terminal 3 from terminal 4. The W8600F is functional. 5. Be sure the battery is installed in the W8600F. Press the reset button on the bottom of the W8600F. All four indicators on the display will flash five times, then ON and FAULT will remain indicated. Connect 9 Vdc to terminal 4 with terminal 1 as ground (use a 9-volt transistor battery). The function panel indicates ON and FAULT. Connect terminal 3 to terminal 4 and the function panel indicates ON, FAULT will turn off. Remove 9 Vdc input. The W8600 is functional. TROUBLESHOOTING Refer to Table 3. Table 3. W8600F Troubleshooting Information. Display Condition Blank Solution EAC is not operating. Turn on EAC. Function panel indicates ON. Press W8600F reset button. DISPLAY flashes five times. ON indicator does not flash when reset button is pressed. Check W8600F battery for 2.7 volts. Replace with BR2032 lithium battery if necessary. Power supply does not have an airflow switch. Assemble jumper on pins 1 and 2 of J3 connector on power supply. Voltage between W8600F terminals 1 (ground) and 4 (+10 to +15 Vdc). Replace W8600F. No voltage, low voltage or wrong polarity. Check wiring between W8600F and EAC. Correct wiring, if necessary. No voltage between EAC terminals 1 (ground) and 4 (+10 to +15 Vdc). Check the driver board and cable installation. Correct installation if necessary. BATTERY, SERVICE or FAULT, but not ON Incorrectly wired. Check wiring between W8600F and EAC. Correct wiring, if necessary. ON and BATTERY Bad battery. Check W8600F battery for 2.7 volts. Replace with BR2032 lithium battery, if necessary. ON and SERVICE EAC cells and prefilters are dirty. Wash and reinstall the EAC cells and prefilters. Press the W8600F reset button. ON flashes five times and SERVICE is off. ON and FAULT Damaged cells. Repair or replace cells. Power supply problem. Press EAC test button and verify output voltage. Replace power supply, if necessary. All four indicators flash after pressing reset button, but ON is not displayed with EAC operation. Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 69-1200—2 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 G.H. Rev. 12-02 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. www.honeywell.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Modify Date : 2002:12:03 11:21:32Z Create Date : 1999:07:07 12:30:47Z Page Count : 4 Creation Date : 1999:07:07 12:30:47Z Mod Date : 2002:12:03 11:21:32Z Producer : Acrobat Distiller 5.0 (Windows) Author : pbacklun Metadata Date : 2002:12:03 11:21:32Z Creator : pbacklun Title : 69-1200-2.fm Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools