Zio®/Zio Plus LCD Wall Modules ® TR70, TR71, TR75 WITH Sylk Bus SPECIFICATION DATA • Programmable for: Home screen options, tenant access, contractor access, optional password protection to contractor mode, access to controller parameters, setpoint, override, fan, and other parameters. • Ability to access and adjust most parameters in the programmable controller. • TR75 can access and adjust the controller schedule. • Ability to balance the VAV system from the wall module. • Home screen can display one to three of any of the following parameters: Temperature Setpoint, Room Temperature, Room Humidity, Outdoor Humidity, Outdoor Temperature, and Time, or one of virtually any parameter in the controller. • Network bus jack. GENERAL The TR70 Series Zio (TR70/TR70-H, TR71/TR71-H) and Zio Plus (TR75/TR75-H) are 2-wire, non-polarity sensitive, Sylk bus communicating wall modules for use with Spyder® and ComfortPoint™ programmable controllers. All models have a space-temperature sensor, network bus jack, and an LCD panel with three softkeys and two Up/Down adjustment keys. The TR7-H, TR71-H and TR75-H models include an onboard humidity sensor. NOTE: Refer to the Zio/Zio Plus LCD Wall Modules Operating Guide (form 63-2719) for information about customizing the wall module configuration in the WEBs-AX Workbench, such as modifying the default Home screens or creating your own application. FEATURES • Simple 2-wire terminal connection to the programmable controller (includes power) and an optional 2-wire terminal connection for the network. All connections are polarity insensitive. • Permanent retention of user configuration, including setpoints after a power outage. Table 1. TR70 Series Features. Features Zio Zio TR70 TR71 Scheduling Zio Plus TR75 x Parameter Memory (bytes) 1K 2K 4.9K Up to four Zios on Sylk x* x x Enumerated Values x x Setpoint Limits as NVs – linking now possible x x System and Fan command as NVs x x Password protection x x The TR70 Series wall modules include: • Ability to control tenant access to controller parameters via password protection. Firmware version/model visible on display x x 0.5 and 5 value increments x x • Ability to assign labels for enumerated values. "-" and "/" characters in parameter names x x • Customized parameter access, by using the Honeywell WEBs-AX Workbench tool. • Ability to link setpoint limits to a network variable. * Support for up to four TR71 and/or TR75s per Spyder, and if a TR70 is present, a maximum of three Zios (any combination of models) are allowed. 63-1322-02 ZIO®/ZIO PLUS LCD WALL MODULES SPECIFICATIONS Compatibility: Full feature set, including scheduling and password protection requires the latest Spyder firmware (field upgradeable with Spyder Flash Tool), Spyder Tool version greater than 5.18, and WEBs-AX Workbench version 3.4.57 or greater. 1 2 3 NET-1 NET-2 S-BUS (optional) (optional) HONEYWELL TR70-H PATENT PENDING GOLDEN VALLEY,MN ASSEMBLED IN MEXICO YY WK 50028668-XXX Construction: Two-piece construction, cover and internally wired subbase. Field wiring, 18 to 24 AWG (0.82 to 0.20 sq. mm), connects to a terminal block in the subbase. 0 9 4 S-BUS 1 2 3 8 76 SLOTS FOR SUBBASE LOCKING TABS (X4) WALL MODULE BUS ADDRESS DIAL (DEFAULT SETTING = 1) 4 5 S-BUS PROGRAMMABLE CONTROLLER CONNECTION Mounting Options: The LCD wall modules can be mounted on a standard two by four inch junction box or on a 60 mm diameter junction box. The modules may be mounted up to 200 ft. (61 m) from the programmable controller. Twisted pair wiring is recommended for distances longer than 100 ft. (30.5 m). 1 Dimensions (H/W/D): See Fig. 2 on page 2. 1 Environmental Ratings: Operating Temperature: 30°F to 110°F (-1°C to 43°C) Shipping Temperature: -40°F to 150°F (-40°C to 65.5°C) Relative Humidity: 5% to 95% non-condensing 2 3 4 1 NETWORK BUS CONNECTION EACH OF THE TWO WIRE CONNECTIONS FOR THE S-BUS AND NETWORK BUS TERMINALS ARE POLARITY INSENSITIVE. M27349 Fig. 1. LCD wall module components (rear view). NOTE: 18 Vdc power for the LCD wall modules is supplied from the programmable controller. Temperature Setpoint Range: Default range is 55°F to 85°F (10°C to 35°C); configurable for other ranges. Module Dimensions Temperature Sensor Accuracy: ±0.36°F at 77°F (±0.2°C at 25°C) 3 5/16 (84) Humidity Sensor Accuracy (TR71-H/TR75-H only): ±5% RH from 20% to 80% RH Power: 18 Vdc power is supplied to the wall module from the 2-wire S-BUS connection to the programmable controller. Accessories: 50007298-001 (pack of 12) medium, cover plate; 6-7/8 x 5 in. (175 x 127 mm). 4 5/8 (117) Approvals: CE; UL94-HB plastic enclosure; FCC Part 15, Class B Terminal Wiring Location Fig. 1 illustrates the location of the terminal block and other features on the TR70 Series wall modules. 15/16 (24) M27347 Fig. 2. Wall module dimensions in inches (mm). Communications The wall modules use a sensor bus (S-BUS) for communications with the programmable controller. For network communication, the building’s LON or BACnet® network wires connect to the two terminals (NET-1 and NET2). See Fig. 1. A network bus port is accessible at the bottom of the wall module by removing the jack plug. The network bus and S-BUS terminals (see Fig. 1) are insensitive to polarity, minimizing installation errors due to mis-wiring. The recommended wire size for the network bus 63-1322—02 2 ZIO®/ZIO PLUS LCD WALL MODULES and S-BUS is 18-24 AWG (0.82 to 0.20 sq mm) depending on application, plenum or non-plenum rated, unshielded, twisted pair, solid conductor wire. LCD Display The LCD display may be customized for tenant and contractor users. The following are a few samples of the various Home screens that are configurable for the LCD Wall Modules. Not all possible Home screens are illustrated here. There are many other configurable Home screens. NOTES: 1. 2. Home screens can display one to three of any of the following parameters: Temperature Setpoint, Room Temperature, Room Humidity, Outdoor Humidity, Outdoor Temperature, and Time, or one of virtually any parameter in the controller. M27377 Fig. 5. Sample Tenant Home screen with Setpoint display only. Refer to the Zio/Zio Plus LCD Wall Modules Operating Guide (form 63-2719) for information about customizing the wall module configuration in the WEBs-AX Workbench, such as modifying the default Home screens or creating your own application. Sample Tenant LCD Displays The Fan and Occupied settings are optional for Home screen setup. If there are no parameters configured for Tenant access, the “View More” softkey does not display on the Tenant Home screen. M27356 Fig. 6. Sample Tenant “View More” display showing CO2 sensor value from controller. NOTE: Any configured parameter may be displayed. Sample Contractor LCD Displays The Contactor mode allows advanced options using the softkeys. Contractor mode also allows for customizing the Tenant view, including setting the tenant’s Home screen and “View More” access. M27354 Fig. 3. Sample Tenant Home screen with System Status, Setpoint, Outside Temperature, and Room Temperature (predominant). M27357 Fig. 7. Sample Contractor Home screen display with System Status, Setpoint, Outside Temperature, and Room Temperature (predominant). CONTACTOR HOME SCREEN SOFTKEYS The three softkeys on the Contractor Home screen (Fig. 7) provide the following: SET HOME SCREEN - allows the contractor to choose among multiple Home screen options for the tenant. M27379 Fig. 4. Sample Tenant Home screen with Room Temperature and Time (predominant). 3 63-1322—02 ZIO®/ZIO PLUS LCD WALL MODULES SET VIEW MORE - allows the contractor to give additional parameter access (view only or adjustable) to the tenant. TYPICAL SPECIFICATION 1. 2. PARAMETERS - allows the contractor to monitor and/or adjust parameters in the programmable controller. M27358 Fig. 8. Sample Contractor parameter display showing user-created discharge air parameter value. 3. 4. 5. 6. 7. 8. 9. M27359 Fig. 9. Sample Contractor parameter display showing sensor setpoint value (CO2 sensor from controller). NOTE: Any configured parameter may be displayed. 10. 11. 12. 13. 14. 15. 16. The wall module shall have an LCD display. The wall module shall have a customizable home screen: a. Shall have the option to show up to 3 parameter values on a single display. b. Shall have the option to show occupied status. c. Shall have the option to show system status. d. Shall have the option to show fan status. e. Shall have the option to show up to three of the following parameters: • room temperature, setpoint, outside temperature, room humidity, outside humidity, time of day. f. Shall have the option to show on the home screen any single parameter in the controller, with a user defined 8 letter name. The wall module shall offer access to all parameters necessary to balance a VAV system. The wall module shall offer the ability to restrict access to parameter information with keypad enabled lock out and with optional 4 digit password protection (password on TR71 and TR75 only). The wall module shall retain user configuration including setpoints after power outage. The wall module shall use a two wire polarity insensitive connection for all communication and power needs. The wall module shall offer the ability to access and adjust virtually all controller parameters. The wall module shall offer the ability for the tenant to adjust override time period within the limits set by the contractor. The wall module shall offer a communication jack for remote access to the network. The wall module shall offer a ± 5% on board humidity sensor (TR70-H, TR71-H, and TR75-H only). The wall module shall be configured through the Honeywell WEBs-AX Workbench tool. The wall module shall communicate with other devices using the Sylk bus protocol. The wall module shall be compatible with LON and BACnet controllers. The wall module shall offer the ability to view/edit the controller's schedule (TR75 only). The wall module shall have the ability to display enumerated values as text. The wall module shall have the ability to use the value of a parameter as the upper or lower limit of another parameter (TR75 only). ComfortPoint™ is a trademark of Honeywell International Inc. LONMARK® is a trademark of the LonMark Association. BACnet® is a registered trademark of BACnet International. Spyder® is a registered trademark of Honeywell International Inc. Sylk® is a registered trademark of Honeywell International Inc. Zio® is a registered trademark of Honeywell International Inc. Automation and Control Solutions Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 customer.honeywell.com ® U.S. Registered Trademark © 2011 Honeywell International Inc. 63-1322—02 M.S. Rev. 12-11 Printed in United States
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Assemble, Print high-res Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Creator Tool : FrameMaker 9.0 Modify Date : 2012:04:19 14:41:48-05:00 Create Date : 1999:07:07 12:30:47Z Metadata Date : 2012:04:19 14:41:48-05:00 Format : application/pdf Title : 63-1322—02 - Zio®/Zio Plus LCD Wall Modules Creator : Honeywell ECC Technical Communications Description : Specification Data Producer : Acrobat Distiller 9.4.6 (Windows) Document ID : uuid:3c9bb5ba-c078-452a-9ca4-dd44f21bf47a Instance ID : uuid:dacd3913-fb44-45c3-8474-c21138664dfb Page Count : 4 Subject : Specification Data Author : Honeywell ECC Technical CommunicationsEXIF Metadata provided by EXIF.tools