Honeywell MLPN5600A Terminal User Manual SP5600 User s Manual

Honeywell International Inc. Terminal SP5600 User s Manual

Users manual

Download: Honeywell MLPN5600A Terminal User Manual SP5600 User s Manual
Mirror Download [FCC.gov]Honeywell MLPN5600A Terminal User Manual SP5600 User s Manual
Document ID836968
Application IDTPldc+HYBiqHYO1acCcsJQ==
Document DescriptionUsers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize28.96kB (362029 bits)
Date Submitted2007-08-30 00:00:00
Date Available2007-08-30 00:00:00
Creation Date2007-08-03 10:26:21
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2007-08-30 10:26:05
Document TitleMicrosoft Word - SP5600 User's Manual.doc
Document CreatorPScript5.dll Version 5.2
Document Author: herbie.jiang

SP5600 Terminal
User's Guide
Version 1.00
Table of Contents
Table of Contents .................................................................................................................................ii
1. Preface..........................................................................................................................................1
2. General Features and Characteristics...........................................................................................2
2.1
Electrical ......................................................................................................................2
2.2
Environmental..............................................................................................................2
2.3
Physical ........................................................................................................................2
2.4
CPU..............................................................................................................................2
2.5
Memory........................................................................................................................2
2.6
Reader ..........................................................................................................................2
2.7
Display .........................................................................................................................3
2.8
Keypad .........................................................................................................................3
2.9
Indicator .......................................................................................................................3
2.10
Communication............................................................................................................3
2.11
802.11b/g WLAN Specification...................................................................................3
2.12
Software .......................................................................................................................3
3.
4.
Software Architecture ..................................................................................................................4
3.1
Kernel & Application Manager....................................................................................4
3.2
System..........................................................................................................................5
3.3
Application.................................................................................................................10
3.4
Programming the terminal .........................................................................................10
3.5
Programming the communication cradle ...................................................................10
Operations .................................................................................................................................. 11
4.1
Keypad operations...................................................................................................... 11
4.2
Application mode....................................................................................................... 11
4.3
System mode..............................................................................................................12
4.4
Kernel mode...............................................................................................................12
4.5
Application Manager..................................................................................................12
低功率電波輻射性電機管理辦法
第十二條
經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者不得擅自
變更頻率、加大功率或變更原設計之特性及功能。
第十四條
低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象
時,應立即停用,並改善至吳干擾時方得繼續使用。
前項合法通信,指依電信法規定作業之無線電通信。
低功率射頻電機需忍受合法通信或工業、科學及醫療用電波輻射性電機設備之
干擾。
ii
1. Preface
The SP5600 terminal is rugged, versatile, high performance data terminals designed
for all-day, everyday use. It is powered by a Li-ion rechargeable battery with working
time longer than 16 hours. It is supported by a rich set of development tools, including
a Windows-based application generator, “C” and “Basic” compilers. With its
integrated Laser/CCD barcode scanning unit and 802.11b/g WLAN module, the
SP5600 terminal is ideal for real time applications such as inventory control, shop
floor management, warehousing and distribution operations.
CAUTION :
RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCT
Battery disposal For green-environment issue it's important that batteries should be recycled
in a proper way.
FCC Regulations:
zThis device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
zThis device has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiated radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void
the user‘s authority to operate the equipment.
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm between the radiator &
your body.
It only operated in hand-held used. If you only transfer data to Host by WLAN, please keep the minimum
distance 20cm between machine & your body.
2. General Features and Characteristics
Basic characteristics of the SP5600 Terminal are listed below,
2.1 Electrical
Operation battery: 3.7V Li-ion rechargeable battery, 1800mAH
Backup battery: 3.0V, 7mAH rechargeable Lithium battery for SRAM & calendar
Working time: 16 hours
2.2 Environmental
Operating Humidity: non-condensed 10% to 90%
Storage Humidity: non-condensed 5% to 95%
Operating Temperature: 0 to 50 °C
Storage Temperature: -20 to 70 °C
EMC regulation: FCC, CE and C-tick
Shock resistance: 1.2m drop onto concrete
IP rating: IP65
2.3 Physical
Dimensions:170mm (L) x 80mm (W) x 44mm (H)
Weight: 250g (including battery)
Color: Black
Material: ABS
2.4 CPU
Toshiba 16-bit CMOS type CPU
Tunable clock, up to 22MHz
2.5 Memory
Program memory
y 1 M Bytes flash memory is used to store the program code, font, constant data, and so on.
Data memory
y 256K Bytes SRAM
2.6 Reader
The Terminal can be equipped with either Laser or Long Range CCD scanner. Detailed specifications
are as follows:
SP5600 (Laser)
Light source: visible Laser diode operating at 670±15nm
Scan rate: 36±3 scans per second
Scan angle: 42°nominal
Minimum print contrast: 20% absolute dark/light reflectance at 670nm
Depth of field: 5 ~ 95 cm, depends on barcode resolution
SP5600 (CCD)
y
Resolution: 0.125mm ~ 1.00mm
Depth of field: 2 ~ 20cm
Width of field: 45mm ~ 124mm
Scan rate: 100 scans/sec
Ambient Light Rejection:
1200 lux (Direct Sun-light)
2500 lux (Fluorescent Light)
2.7 Display
100x64 graphic dots FSTN LCD display with LED back-light
2.8 Keypad
24 numeric rubber keys.
2.9 Indicator
Buzzer
y Software programmable audio indicator, 1KHz to 4KHz, low power transducer type.
LED
y Programmable, dual-color (green and red) LED for status indication.
2.10 Communication
RS-232: Baud rate up to 115200bps
Serial IR: Baud rate up to 115200bps
Standard IrDA: Standard 1.0 compatible. Baud rate up to 115200bps
2.11 802.11b/g WLAN Specification
SP5600 Terminal
Frequency Range:
Modulation:
Data Rate:
Channels:
Coverage:
Maximum Output Power:
Compliance:
2.4 ~ 2.4835 GHz, unlicensed ISM Band
DSSS with DBPSK, DQPSK, and CCK
OFDM with BPSK, QPSK, QAM, and 64QAM
11 / 54 Mbps Auto-fallback
Standard
100M line-of-sight
49mW / 22 mW
IEEE 802.11b/g & Wi-Fi compliance
Access Point
Works with commercially available standard IEEE 802.11b/g Access Point
2.12 Software
Operating System: CipherLab proprietary OS
Programming Tools: “C” compiler, BASIC compiler and a Windows-based Application
Generator
3. Software Architecture
The Terminal system software consists of three modules: the kernel & Application Manager
module, the System module and the Application module.
3.1 Kernel & Application Manager
The kernel is the innermost core of the system. It has the highest security and is always protected by
the system. Only the failure of flash memory or improperly power off during system restart after
updating kernel will the kernel be destroyed. The kernel module ensures that users can always
download their application program even the operating system was crashed by the user’s program.
The kernel provides the following services:
Kernel Information
Information includes hardware version, serial number, manufacturing date, kernel version and
hardware configurations.
Load Application
To download the application program, BASIC run-time or font files.
Kernel Update
Sometimes the kernel might be changed for improving performance or other reasons. This
function allows you to keep the kernel updated. The update procedure is same as download user
program, but note that after updating the kernel, please do not power off until the system restart
itself.
Test & Calibrate
To perform a burn-in test and tune the system clock. This function is for manufacturing purpose
only.
Besides the kernel menu, if there is no application program exists, then upon power up the terminal
the following Application Manager’s menu will be shown:
Download
To download application programs (*.SHX), BASIC run-time (BC83x0.SHX), BASIC
programs (*.SYN) or font files (8xxx-XX.SHX) to the terminal. There are 6 resident locations
and one Active Memory, i.e. at most 7 programs can be downloaded to the terminal. But only
the one downloaded to the Active Memory will be activated and running. To run other
programs, they need to be activated first, but only one at a time. Right after downloading, you
can input a name for the program or just press the enter key to keep its current name if there is.
And then the downloaded program’s type, name and size will be shown on the list when
entering the Download or Activate menu of the Application Manager. The file type is a small
letter follows the program number (01~06), it can be either ‘b’, ‘c’ or ‘f’ which represents
BASIC program, C program or font file respectively. The program name is up to 12 characters
and the program size is in unit of K bytes.
Activate
To copy one of the 6 resident programs to the Active Memory to make it become the active
program. After activating, the original program in the Active Memory will be replaced by the
new one. Note a font file cannot be activated, and a BASIC program cannot be activated either
if the BASIC run-time does not exist.
Upload
To transmit the application programs to a host PC or another terminal. The function allows a
terminal to be cloned without going through a PC.
3.2 System
The system module provides the following services:
Information
The system information includes hardware version, serial number, manufacturing date, kernel
version, C library or BASIC run-time version, application program version and hardware
configurations.
Settings
The system settings include the following:
1. Clock
Set date and time for the system.
2. Backlight ON Period
Set the staying on duration for the keyboard and LCD backlight.
Default: the lights go off after 20 seconds.
3. CPU Speed
Set CPU running speed. There are five speeds available:
Full speed, half speed, quarter speed, eighth speed and sixteenth speed.
Default: Full speed
4. Auto Off
Set time threshold for automatically power off when no operation is taking place during
that specified period. If this value is set to zero, this function will be disabled.
Default: 10 minutes
5. Power On Options
There are two possible selections: Program Resume, which starts from the program being
used during the last session before the last power-off; and Program Restart, which starts
with a new program.
Default: Program Resume
6. Key Click
Select a tone for the beeper or disable the beeper when the user presses a key button.
Default: Enable
7. System Password
Set a password to protect the user from entering the system menu.
Default: no password is set
8. Font
This option will display the current font file name and version. Languages can be selected
by pressing “arrow up” or “arrow down” key if multi-font file is downloaded.
Supported languages in multi-font file:
[16] System Font
[17] French
[18] Hebrew
[19] Latin
[20] Nordic
[21] Portugal
[22] Russian
[23] Slavic
[24] Polish
[25] Turkish
[26] Slovak(CP1250)
Default: System Font
Tests
1. Reader
To test the reading performance of the scanner. The following barcodes are default to
enable:
Code 39
Industrial 25
Interleave 25
Codabar
Code 93
Code 128
UPCE
UPCE with ADDON 2
UPCE with ADDON 5
EAN8
EAN8 with ADDON 2
EAN8 with ADDON 5
EAN13
EAN13 with ADDON 2
EAN13 with ADDON 5
Other barcodes must be enabled through programming.
2. Buzzer
To test the buzzer with different Frequency/Duration. Press ENTER key to start and then
press any key to stop the test.
3. LCD & LED
To test LCD display and LED indicator. Press ENTER key to start and then press any key
to stop the test.
4. Keyboard
To test the rubber keys. Press a key and the result will be shown on the LCD display. Note
that the FN key should be used in conjunction with numeral keys.
5. Memory
To test the data memory (SRAM). Note after the test, the contents of the memory space will
be wiped out.
Memory
1. Size Information
Information includes sizes of the base memory (SRAM), memory card (SRAM) and
program memory (FLASH) in the unit of kilobytes.
2. Initialize
To initialize the data memory (SRAM). Note the contents of the data space will be wiped
out after memory initialization.
Power
Show the voltages of the main battery and backup battery.
Load Application
To download the application program, BASIC run-time or font file. There are three interfaces
supported by the system, namely, the Direct-RS232, Cradle-IR and standard IrDA.
Download.exe is required when Direct RS232 or standard IrDA interface is used. And
IrLoad.exe is required when Cradle-IR is used.
802.11b/g Menu
This item will be displayed only if an 802.11b/g module is installed.
1. Information
It includes the WLAN LIB version, MAC ID, DHCP status, IP address, Subnet Mask, and
Gateway.
2. IP Settings
DHCP Server will dynamically assign the following IP settings to the terminal if DHCP
Server is installed and the option is enabled. These IP Settings also can be configured
manually if DHCP is disabled. Please contact your MIS engineer if you don’t know how to
configure it.
1). DHCP
DHCP stands for Dynamic Host Configuration Protocol.
Default: [1] Enable
2). SubNet Mask
The number used to identify the IP sub-network, indicating whether the IP address can
be recognized on the LAN.
Default: 255.255.128.0
3). Local IP Address
The address which identifies a location of the terminal on the network must be unique.
Default: 0.0.0.0
4). Default Gateway
the Gateway IP address is the IP address of a local router in between the forwarding
node and the remote network.
Default: 0.0.0.0
5). DNS Server
Domain Name Server is a distributed, replicated, data query service mainly used on the
Internet for translating host names to IP addresses.
Default: 0.0.0.0
3. WLAN Settings
The RF settings and their default values are as follows,
1). Local Name
Specify name for terminal SP5600
Default: the S/N of the SP5600 terminal
2). Domain Name
The domain name locates the organization or other entity on the Internet.
Default: 
3). SS ID
The SSID is a 32-character (maximum) string identifying the wireless local area
network. All APs & terminals within the same service set should have the same SSID.
Default: 
4). System Scale
This option which depends on the Access Point Density determines when the terminal
should look for other Access Point that has bigger signal strength.
[1] Low
[2] Medium
[3] High
Default: [2] Medium
5). Power Saving
Wireless products can be put in lower power consumption mode when “Power Saving”
is enabled.
Default: [1] Enable
6). Preamble
Select either a short preamble or long preamble. Select a short preamble for SP5600
terminal with high network traffic; select a long preamble when the network traffic is
low.
Default: [1] Long
4. Security
1). Authentication
802.11b/g supports two subtypes of network authentication services: open system and
shared key. Open system authentication is used when no authentication is required.
Under Share Key Authentication, it involves a shared secret key to authenticate the
station to the AP(access point). WEP must be implemented to utilize this.
[0] Share Key
[1] Open System
Default: [1] Open System
2). WEP Menu
„
WEP Setting
Wireless Equivalent Privacy (WEP) is an encryption to translate data into a secret
code. It provides wireless clients with confidentiality and authentication in an IEEE
802.11b/g environment.
[0] Disable
[1] Enable
Default: [0] Disable
„
WEPKey Length
When WEP is enabled, Data sent between the client and the access point is
scrambled using either a 64-bit or 128-bit key. The higher the level of encryption,
the more secure it is.
[0] 64 bits
[1] 128 bits
Default: [1] 128 bits
„
Default Key
Activate one of the four encryption keys
Default: [1] WEP KEY1
„
WEP Key
Define the encryption key values for Key1~Key4 using hexadecimal digits.
When WEPKey Length “64 Bit” is selected, the user is required to fill in 5 bytes of
hexadecimal values as the encryption key.
When WEPKey Length “128 Bit” is selected, the user is required to fill in 13 bytes
of hexadecimal values as the encryption key.
3). EAP Menu
EAP Stands for Extensible Authentication Protocol. SP5600 terminal only support
EAP-MD5. When these features are implemented, a wireless client that associates with
an access point cannot gain access to the network until the user performs a network
logon. Therefore, Identity and Password are needed when EAP is enabled.
„
„
„
EAP Setting
EAP ID
EAP Password
5. Echo Tests
The terminal will echo the received data from the client or server and also signals a beep.
The function is used to measure the coverage of the range, estimate the number of APs and
terminals needed, and determine the AP’s deployment topology.
1. Client Mode
2. Server Mode
Cipherlab provides TCPServer.exe (only for Client Mode) and TCPDemo.exe for Echo
Tests.
Once the connection of Echo Test is established, the details will be displayed as the
illustration below.
Sending 033
Recv ok 033
Q: 0070
S: 0133
T: 11M
N: 0006
3.3 Application
The Application module runs on top of the System module. The SP5600 Terminal is preloaded with
the Application Generator’s run-time program and the following menu will be shown upon powering
the unit up:
1. Take data
2. Utilities
The arrow keys can be used to select the menu item, and execute it by pressing the ENTER key. Note
if you use the Application Generator to create your application program, you need to download it to
the terminal. And for RF models, you need to use the RF Database Manager to handle the in-coming
and out-going data to and from the PC. For detailed information, please refer to SP5600 Application
Generator User’s Guide” and “RF Application Generator User’s Guide”.
3.4 Programming the terminal
There are three software tools available for developing application programs for the terminal.
1. The Application Generator
2. The “BASIC” Compiler
3. The “C” Compiler
Besides, Terminal Emulation program which supports ANSI (VT100& VT220) and IBM is also
available. For detailed information, please contact Syntech Information Co., Ltd.
3.5 Programming the communication cradle
The communication cradle of the SP5600 Portable Data Terminal supports serial IR interface only.
Before your PC application starts to communicate with the terminal via its cradle, first you need to
configure the cradle through programming. There is a DLL available for this purpose. For more
information, please contact your supplier .Syntech Information Co., Ltd.
10
4. Operations
Batteries must be fresh and properly loaded before start operation.
4.1 Keypad operations
The Terminals have two keyboard layouts: 24 rubber keys. The functions of some special keys are as
follows:
SCAN
Scan a barcode.
Press this button will trigger the scanner to read a barcode if the scanner port is
enabled.
ENTER
Enter.
There are two enter keys on the side of the scan key. Normally the enter keys are
used for command execution or input confirmation.
ESC
Escape.
Usually this key is used to stop and exit current operation.
BS
Back Space.
If this key is being pressed down longer than one second, a clear code will be
sent.
ALPHA / α
The toggle key for Alphabet / Numeral input.
When the system is in alpha-mode, a small icon will be shown on the display. For
the 24-key keyboard, each numeral key can be used to generate one of the three
capital letters. For example, numeral 2 can be used to produce A, B or C. Pressing
the same key twice within one second, will call the letter B. Pressing the same
key without halting longer than one second, will cause the three letters to be
shown in a circulating way. Only when stop pressing the key for longer than one
second or pressing another key, will the system send the real key code to the
application program. Pressing the “Alpha” key again, lower case letter can be
inputted.
FN
The function key.
This key cannot be activated alone, it must be pressed with one numeral key at
the same time. For example, FN + 1 generates function #1, FN + 2 generates
function #2, etc (up to 9 functions). Also, this key can be combined with the
UP/DOWN arrow keys to adjust the contrast of the LCD. And when this key is
combined with the ENTER key, it will turn ON/OFF the backlight.
POWER
Power On/Off.
To prevent a faulty push, it needs about 1.5 sec continuous pressing to turn
On/Off the power.
4.2 Application mode
This is the default operation mode when turning on the power. The operation depends on the
application module. Please refer to section 4.4.
11
4.3 System mode
To enter the system menu, you need to press the 7, 9 and POWER keys simultaneously upon power
up the terminal. For details of the services provided by the system, please refer to section 4.2.
4.4 Kernel mode
To enter the kernel menu, you need to press 7, 9 and POWER keys simultaneously to enter the system
menu first, then power off the unit and press 1, 7 and POWER key simultaneously. Or if the battery is
just reloaded, then press 1, 7 and POWER key simultaneously will directly go to the kernel. For
details of the services provided by the kernel, please refer to section 4.1.
4.5 Application Manager
Although the Application Manager is part of the kernel, to enter it, you need to press ‘8’ and POWER
key simultaneously. Or if the application program does not exist, the unit will automatically go to the
Application Manager’s menu upon power up.
The three services: Download, Activate and Upload provided by the Application Manager are
explained in Section 4.1. But what if you need to update a program or delete it? For both cases, you
need to select the Download menu and select the program to be updated or deleted. The Application
Manager then shows the selected program’s information such as Program Name, Download Time,
Used and Free Flash memory. And then please input ‘C’ to update the selected program, or input ‘D’
to delete it.
12

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 14
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:68544747-9d21-4da2-85e2-b2ee255a6e47
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2007:08:30 10:26:05+08:00
Create Date                     : 2007:08:03 10:26:21+08:00
Metadata Date                   : 2007:08:30 10:26:05+08:00
Document ID                     : uuid:a7db09b4-a244-4a23-b3d5-642bccb956cd
Instance ID                     : uuid:26350077-853e-48d7-9200-94d1427e6c22
Format                          : application/pdf
Title                           : Microsoft Word - SP5600 User's Manual.doc
Creator                         : herbie.jiang
Author                          : herbie.jiang
EXIF Metadata provided by EXIF.tools
FCC ID Filing: LW5-MLPN5600A

Navigation menu