Hoover H3010 User Manual Manuals And Guides L0522802
HOOVER Vacuum, Upright Manual L0522802 HOOVER Vacuum, Upright Owner's Manual, HOOVER Vacuum, Upright installation guides
User Manual: Hoover H3010 H3010 HOOVER HOOVER - Manuals and Guides View the owners manual for your HOOVER HOOVER #H3010. Home:Vacuums & Floor Care Parts:Hoover Parts:Hoover HOOVER Manual
Open the PDF directly: View PDF .
Page Count: 14
Download | |
Open PDF In Browser | View PDF |
HOOVER OwneF_s English e pp, 1.13 Espa_ol ,,_ pag. 15-22 Fran_ais ,,_ p. 24-31 !TM m Manua| m This cleaner inspected and packaged carefully before being shipped from the factory. If you should happen to need assistance during assembly or operation: Visit us online at _,¢ww.hoover.com to find the service outlet nearest you (click on the "Service" button) or Catl 1-800-944-9200 for an automated referral of authorized service outlet locations (U.S. only) or Call 1-330-499o9499 to speak with a representative Consumer Response Center. PLEASE DO NOT RETURN THiS PRODUCT in our TO THE STORE. J Review this manua| before operating c|eaner. wwwoh@@verocem ® in and retain The mode( and serial number are located at the bottom of the back of the cleaner body. For your personal records, please enter the COMPLETE model and serial number in the spaces provided and retain this information. Your cleaner is model and has seriam number It is suggested that you attach your sales receipt to this owner's manual. Verification of date of purchase may be required for warranty service of your Hoover product. lm Assembly ..................................... 3-4 Cleaner descriptions .................. 5 How to use ................................... 5-8 Automatic shut-off ..................... 7 General operation ...................... 6 Clean solution tank ................. 6-7 Recovery tank ....................................... 7 Sto rag e ...................................... 11 How to clean .............................. 9-10 Recommended cleaning sequence ..................................... 9 To clean floor .............................. 9 Cleaning sealed wood floors ..10 Picking up spills ....................... 10 (fYou Have a Problem ................. 12 Service ....................................... 12 important Safeguards .................... 2 Maintenance ............................ 10-11 Cleaning the brushes ......... 10-11 Cleaning the nozzle .................. 11 Warranty ........................................ 13 © 2001 The Hoover www,hoover.com Company When using an electrical appliance, always follow basic precautions, including the following: READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE m arnung • m To reduce • • the risk of fire, electNc shock, or injury: • Use indoors only. Use only on surfaces moistened immerse product. For use on bare floors or seared • Always • Close supervision is necessary when any appliance is used Do not allow cleaner to be used as a toy or to run unattended by or near children. at any time. Keep hair, loose cmothing, and a)(moving parts. away install float before Do not pick up anything or hot ashes. by the wood any wet fingers, that pick feet is burning cleaning floors. process Not for or small spills. Do not use on carpets. up operation. and aH parts or smoking, of body such from as cigarettes, openings matches, Do not pick up or use flammable or combustibme materials such as gasoline or fine wood sandings or use in areas where present. Avoid picking up hard, sharp objects with the cleaner. They may damage the c)eaner. Do not put any object into openings. Do not use with any opening bmocked; keep free of dust, Hnt, hair, or anything that may reduce air flow. Do not pull or carry by cord, use cord as a bandme, close door on cord or pull cord around sharp edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces. • Always • • Unp)ug c)eaner when not in use. Turn off a[) controms before unp[ugging. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord. handle plug or appliance with wet hands. Connect to a propedy grounded outlet only. See "Grounding instructions". Do not clean over floor electrical outlets. • • disconnect cord from electrical outlet before servicing the cleaner. Never • • • Do not use without tanks in pmace. Use extra care when cleaning on stairs. Do not place cJeaner on stairs. The use of an extension cord is not recommended, ff an extension cord is absomutely necessary, use at Beast a 18 gauge 3°wire cord which has a 3oprong grounding type plug and a 3°pole receptacle that accepts the machine plug. • • Keep detergents and other cleaners out of children's Do not pick up ch[orine b)each, pine based c(eaners, any other toxic material with this appliance. • When using ventilated. • Fom[ow manufacturer's instructions not exceed recommended mixing • Store • Do not use with damaged cord or plug. If appmiance is not working as it should, has been dropped, damaged, [eft outdoors, or dropped into water, take it to a Hoover Factory Service Center or Authorized Hoover Warranty Service Dealer (Depot). • Use cleaner in a dry Save recommended place. only for Do not chemicals these machine, for aml chemicals ratios. expose its intended w(th this machine reach. drain cleaner, used to freezing use as described be certain in the with this or area is we[( machine. temperatures. instructions. Do Questions er Concerns? The Hoover Company wants to quickly resolve any concerns about your cleaner or questions regarding its use. Look on the list provided with the product for your local Hoover Factory Service Center or in the Yel= low Pages under "Vacuum Cleaners = Household" for the nearest Authorized Hoover Warranty Service Deamer (Depot) or call: Visit us online button) OR at www.hoover.com Call 1-800-944-9200 Call 1=330=499=9499 to find the service nearest you (click on the "Service" for an automated referral of authorized service outlet locations (U.S. only) OR to speak with a representative in the Hoover Consumer Response Center. Call 1-800-228-4722 for questions or comments ENGLISH® Floor Cleaning Concentrate. Greunding outlet concerning Machine Formula LYSOL® or OLD |nstructiens m This appliance must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electrical current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment=ground= ing conductor (C) and grounding plug (A). The plug must be plugged into an appropriate outlet (B) that is properly installed and grounded in accordance with all local codes and ordinances. Improper connection of the equipmentgrounding conductor can result in the risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. This appliance is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in sketch (A). A temporary adapter (D) may be used to connect this plug to a 2-pole receptacle (E) if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet (B) can be installed by a qualified electrician. The green colored rigid ear, lug, or the like (F) extending from the adapter must be connected to a permanent ground (G) such as a properly grounded outlet box cover. Whenever the adapter is used, it must be held in place by a metal screw. NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electrical Code. Assemble handle C A F AssembJe Handme Press down on latch (A) and remove clean solution tank from upper handle, B Carton A. B. C. D. E. F. contents Hard floor cleaner Upper handle Screw packet (3 screws-l with washer) Brush bmock Nozzle Fioor cleaning concentrates The assembled cleaner will look like this drawing. This cleaner is intended for househomd use. Continued --_ Withcordhook(B)to backofcleaner, Inserttwoscrewsintobackof handle pushupperhandledownontocleaner. asshown.Tightenwitha Phillips Insertscrewwithwasherinfrontof screwdriver. tankarea. Tightenscrewwitha Phillipsscrewdriver. Pushbrushcontrolswitch(C)downto connectswitchrod.Youwill heara "click"whentheswitchrodis in place. f / i Liiili i Replace clean solution tank by positioning bottom first. Press latch and snap top portion into place. To install brushes, place handle in upright position. Tilt cleaner back so that it rests on the floor. Align post (D) on brush block with hole (E) on bottom of cleaner. Turn brushes slightly until post fits easily into hole. Press brush assembly firmly to snap into place. To install nozzle, make sure latches (F) are out. Align middle section (G) of nozzle with opening (H) on cleaner. Remove cardboard packing insert from squeegee area on underside of nozzle. While holding nozzle in place, slide latches inward to lock in place. Cord dip To help keep the cord out of the way while cleaning, position cord down into cord clip (I), located on the handle. 1 2 4 18 17 14 17 12 13 15 The assembled cleaner will look like this drawing, 1. Hand grip 2. Solution trigger: squeeze to release clean solution, 3. Brush control switch: Turns brushes ON for wet cleaning and OFF for wet pickup and dry vacuuming, 4. Clean solution tank release 5. Clean solution tank cap/ measuring cup 6. Clean solution tank 7. ON/OFF switch 8. Recovery tank lid and filter 9. Recovery tank release 10. Recovery tank: Collects dry debris as well as dirty cleaning solution, 11. Wet/Dry pedam: Press pedal to change between wet and dry cleaning, 12. WettDry indBcators: Shows either wet or dry cleaning usage, 13. NozzJe release buttons: Release nozzle for easy clean-up, 14. Brush remease buttons: Remove brushes for easy clean-up, 15. Nozzle 16. Squeegee 17. Handle release peda_ 18. Cord hooks: Top hook rotates for quick cord release, 19. Carrying handle 20. Soft4read wheels This cleaner is intended hold use. ON/OFF To transport for house- Operate cleaner only at voltage specified on data plate on back of cleaner, Plug cleaner into a properly grounded outlet. A Handle Remease Peda_ Step on pedal (A) to lower handle to operating position, Handle does not lock into a single position but "floats" to allow convenient operation, Switch Push switch (B) up to turn cleaner on, Push switch down to turn cleaner off, To move your cleaner from room to room, put handle in upright position; tilt cleaner back on rear wheels and push forward, Condnued -4_ 5 General Operation Your HOOVER FloorMate TM Cleaner can be used to both vacuum dry debris and wet clean non-carpeted floor surfaces such as vinyl, tile and sealed wood, It is not intended for D use on carpet or rugs. Thecleanermayalsobe liftedusing thecarryinghandle(C)onthe backof thecleaner, CAUTION: To prevent damage to wood floors, follow the flooring manufacturer's cleaning recommendations. If using cleaner on sealed wood floors, inspect floor surface for worn finish, bare wood or separated joints. Do not use 'FloorMate' Cleaner to wet clean sealed wood floors if any of these conditions exist. WetlDry pedal and indicators The wet/dry pedal (D) lowers the nozzle squeegee for wet operation and raises it for picking up dry debris, The WET indicator (E) will show red when pedal is set for wet operation, The DRY indicator (F) will show red when pedal is set for dry vacuuming, See "How to clean" section for complete cleaner setup instructions, Step on pedal to choose either the WET or DRY setting, To wet clean with brushes turned on, push the switch down to the WET SCRUB position, For wet pickup, push the switch up to the WET/DRY PICKUP position, In this position, the brushes will not rotate and are raised off the floor surface, G Brush Contro_ Switch The brush control switch (G) turns the brushes on and off, The For dry debris pickup, push the switch up to the WET/DRY PICKUP position, See "How to clean" section for complete cleaner setup instructions, Tanks C_ean Solution Tank) Tank (Upper The clean solution tank holds the cleaning solution that is to be dispersed onto the surface to be cleaned, How to fiJJ Disconnect outlet. cleaner from electrical Place cleaner handle in upright, locked position, To remove tank, press down on release button and pivot tank forward, Carry tank to a sink, Rotate tank cap counter-clockwise and lift up to remove cap, m , , 2.0 ozJ60mL Use Machine Formula OLD ENGLISH@ Wood Floor Cleaning Concentrate for wood floors when cleaning laminate wood, polyurethane sealed wood or other wood floors that can normally be cleaned using water. Check for worn spots or joint separations before using, as these conditions could lead to damaged flooring when using water to clean floor. .m Both of these concentrates Turn cap (H) upside down to serve as a measuring cup. Using cap, measure 2 oz. of applicable concentrate formulated for use with the 'F!oorMate' hard floor cleaner. For best results, use Machine Formula LYSOL@ Floor Cleaning Concentrate when cleaning floor surfaces such as vinyl, ceramic and other tiles, and linoleum. have been specifically formulated to resist excessive foaming and other undesirable effects when used in your 'FloorMate' Cleaner. DO NOT use cleaning concentrates that contain pine or solvent based ingredients. CAUTION: Machine FormuNa LYSOL® Floor Cleaning Concentrate and OLD ENGUSH® Wood Floor CleanEng Concentrate cannot be used in Hoover SteamVac TM products. Doing so could damage your SteamVac TM. Pour cleaning concentrate into tank. Fill tank to fill line (I) (1 quart) with warm water. rubber ring (J) on cap has become dislodged, reposition it with uneven side against ledge (K) as shown. Recovery Tank (mower tank} The recovery tank holds both dry debris and dirty cleaning solution that is picked up from the floor surface. Automatic Replace cap. Rotate cap clockwise until it locks in place. Cap must be locked in place for proper performance and to prevent leaking. Position bottom of tank into cleaner. Press latch and snap tank into place. Shut-Off An automatic suction shut-off is built into the recovery tank to prevent the tank from overflowing. When the shut-off activates, the cleaner will not pick up debris and the sound of the motor will change. There are two reasons the shut-off will activate. 1. Recovery tank is full =Turn the cleaner off and empty the recovery tank. 2. The handle was raised to the upright position wMle the motor was running - Turn cleaner off. Wait a moment for the shut-off to reset. Turn cleaner on and continue cleaning. Cont_ued _-_ 7 How to Empty \ Turn cleaner off and disconnect from emectrical outlet. Although not necessary for satisfactory performance, it is recommended that the recovery tank be emptied after dry vacuuming and before wet operation. Check the solution tank also. It may need to be refilled at this time. Dry or loose debris will also collect on the filter screen (O) in the tank lid. Remove debris from screen. The filter screen may also be cleaned by rinsing it under running water. To remove tank, press down on release button (L) and pivot tank forward. Lift up on tank lid latch (M) and remove the tank lid (N). Empty tank. To replace lid, align tab (P) on lid with hole on front of tank (Q). To replace tank, insert bottom of tank into cleaner and pivot top portion until it is locked in place. Snap latch over tabs (R) on back of tank. The tank lid contains a washable, reusable filter. Clean this filter when suction is low or reduced. To Clean Fi_ter Turn cleaner OFF and disconnect from eJectricam outlet. Remove recovery tank and lid (Fig. 216 & 2-!7). Remove filter lid (S), then remove filter. Remove loose debris from filter by either brushing or tapping the filter. The filter may also be rinsed for additional cleaning. Allow filter to air dry between uses. Replace filter lid. Press down firmly to secure the seal. Cleaning Sequence Use your HOOVER 'F!oorMate' Cleaner to: 1. Dry Vacuum to remove loose dirt, hair and debris. 2. Wet Clean the floor surface. The brushes will provide light agitation to help loosen dirt. 3. Wet Pickup reduces drying time of the floor surface. Follow the chart to set the controls for each cleaning step. OPERATION Dry Vacuuming Wet Cleaning Wet Pickup BRUSH CONTROL SWmTCH WET/DRY "Wet/Dry Pickup" (UP) PEDAL Dry Pickup "Wet Scrub" (DOWN) Wet Pickup/ Scrub "Wet/Dry Pickup" (UP) Wet Pickup/ Scrub See Page 6 Figs. 2-6 and 2-7 for complete instructions on the control switch and pedal. To Clean lineleu_, The cleaner's suction will pick up the dirty solution throughout cleaning. Fmeer {vinym, ti_e, eteo} 1. Set cleaner for Dry Vacuuming operation and vacuum floor. (See chart on page 9.) A 2. Empty Recovery Tank. (Figs. 2-16 through 2-20). 3. Fill solution tank with Machine Formula LYSOLO Floor Cleaning Concentrate and water, according to instructions for Figs. 2-8 through 212. Do not use pine or solvent based cleaning concentrates in your cleaner. Do not use any type of wax in your cleaner. 8. To greatly enhance dP/ing of the floor surface, release trigger and move wet control switch up to the "WET/DRY PICKUP" setting. Continue to move cleaner over the area to pick up the dirty solution. 9. To continue cleaning another area, move wet control switch down to 6. Step on handle release pedal and lower handle to operating position; turn cleaner ON. 4. Set cleaner controls for "Wet Cleaning" operation. (See chart on page 9.) 7. To release solution, squeeze trigger (A). Slowly move cleaner forward and backward over area to be cleaned. Squeeze trigger to release solution as needed. 5. Dry hands and plug cleaner into a properly grounded outlet. Overlap strokes by one inch to help prevent streaking. "WET Scrub". Repeat with steps 7-9. NOTE: When switching between wet cleaning and wet pickup, it is not necessary to turn the cleaner off. Simply move the control switch back and forth between the two settings. 10. Empty recovery tank or clean the filter when the motor sound becomes higher in pitch and there is a loss of suction (see "Automatic Shut-Off", page 7). Cleaning Floors $ea_ed Wood Your HOOVER _FloorMate' Cleaner may be used to clean wood floors that have been sealed with a polyurethane coating and can be cleaned with water. CAUTION: To prevent damage to wood floors, follow the flooring manufacturer's cleaning recommendations. If using cleaner on sealed wood floors, inspect floor surface for worn finish, bare wood or separated joints. Do not use 'FIoorMate' C_eaner to wet clean sea_ed wood floors if any of these conditions exist. 9. To greatly enhance drying of the floor surface, release trigger and move wet control switch to the "WET PICKUP" setting. 10. To continue cleaning, move wet control switch down to "WET Scrub". Repeat steps 7 - 9. Make sure all areas are completely dry. Ensure that no water remains on the floor. 1. Inspect floor surface for worn finish, bare wood or separated ioints. Do not use your 'FloorMate' Cleaner to wet clean the floor if any of these conditions exist. 2. Set cleaner for Dry Vacuuming operation and vacuum floor (see chart on Page 9). 3. Empty recovery tank (Figs. 2-16 through 2-20). 4. Fill solution tank with Machine Formula OLD ENGLISH® Wood Floor Cleaning Concentrate and water, according to instructions for Figs. 2-8 through 2-12. 7. Step on handle release pedal and lower handle to operating position; turn cleaner ON. 8. Push cleaner forward, squeeze trigger while pulling cleaner backward. Release trigger and push cleaner forward. Continue cleaning floor surface while releasing solution on the backward strokes only. This will allow for effective cleaning with small amounts of solution. Overlap strokes by 1 inch to help prevent streaking. 11. Empty the recovery tank or clean the filter when the motor sound becomes higher in pitch and there is a loss of suction (see "Automatic Shut-Off", Page 7). Picking Lip Spills Your cleaner may also be used to pick up small liquid spills (1 quart or less, never to exceed 114 inch in depth} on non-carpeted floors. Set Wet/Dry pedal in the WET Pickup/Scrub position. Set Wet Control switch to the "WET/DRY Pickup" position. Do not use the cleaner to pick up flammable or combustible liquids or chemicals. Do not use the cleaner to pick up detergents that contain pine or solvent based ingredients. A the 6. Dry hands and plug cleaner in to a propeNy grounded outlet. Do not use pine or solvent based detergents. Do not put any type of wax in your cteaner. NOTE: When switching between wet cleaning and wet pickup, it is not necessary to turn the cleaner off. Simply move the control switch back and forth between the two settings. Cleanincj 5. Set cleaner controls for "Wet" Cleaning (see chart page 9). -____ '_,_,!;_ii_ii,i,i!i!!i!!i_ii!_i_!i_!i_!i_!i_iiii!!iiii'i_i_iiiiiiii,_ _ brushes Turn cleaner OFF and disconnect from electrical outlet. The brush assembly can be removed for easy cleaning. Push the two brush release buttons (A) at the same time. Tilt cleaner back slightly and remove brush assembly (B). The brushes can be washed with a mild detergent and rinsed. Do not use pine or solvent-based detergents. 10 Toreplacebrushes,firstremovesolu- Pressbrushassemblyfirmlyto snap tiontank(Fig.2-8)andrecoverytank intoplace. (Fig.2-!6). Settanksaside. Thiswill preventpossibleleaking. Withhandlein uprightposition,tilt cleanerbackso thatit restsonthe floor. Alignpost(C)on brushblockwith hole(D)on bottomofcleaner.Turn brushesslightlyuntilpostfitseasily intohole. Cleaning Slide the two nozzle release latches (F) outward. Remove nozzle (E) by pulling straight out. To replace nozzle, make sure latches are out. Rinse nozzle under running water. Remove debris from squeegee (G) and wipe with a damp cloth. Align middle section (H) of nozzle with opening (I) on cleaner. the Nozzle Turn cleaner OFF and disconnect from electrical out{et. The cleaner's nozzle (E) can be removed for easy cleaning. Sterage \ While holding nozzle in place, slide latches inward to lock in place. Before storing cleaner: Turn cleaner OFF and disconnect from electricaJ outJet. ,, Empty and rinse solution and recovery tanks. Allow to air dry. o Allow filter in recovery tank lid to dry. o Set the cleaner for "Dry Vacuuming" (pedal to "DRY" and Wet Control switch up). ,, Make sure that nothing is pressing on the nozzle squeegee. o Do not store cleaner on a wood surface unless cleaner is compJetely dry. Continued _ 11 Service If a minor problem occurs, it usually can be solved quite easily when the cause is found by using the check list below. Possible cause Possible solution Not firmly plugged in . Plug unit in firm/}/. , No voltage in wail plug Check fuse or breaker. . Blown fuse/tripped breaker . Replace fuse/reset breaker. Possible cause Possible solution , Automatic shut-off activated . Turn cleaner OFF and then ON again or Empty recovery tank (see "Automat/c shut-off" section) , Filter or fitter lid missing or not positioned correctly . Ensure that filter and filter hd are proper/}/positioned in the recover}/ tank lid (Fig. 2-22) , Recovery tank andtor solution tank not positioned properly . Ensure that both tanks are locked in place. , Fitter is dirty . Clean filter , Nozzle not properly positioned . Ensure nozzle is replaced properly and locked (Figs. 4-8 & 4-9). Possible cause Possible solution Cleaner not set for wet operation Press wet/dry pedal to "WET" posF tion. , Recovery tank not properly installed . Ensure that recovery tank is installed proper/}/(Fig. 2-20). Recovery tank full/automatic shutoff engaged. Remove and empty recover}/tank. , Filter or filter lid missing or not properly positioned. . Ensure recovery tank filter and filter lid are proper/}/installed (Fig. 2-22). PossibJe cause Possible solution . Cleaner not set for dry operation . Press wet/dry pedal to "DRY PiCKUP" position. , Debris is too large to cJear squeegee . Tip nozzle off floor by pushing dovvn on handle. Possible cause Possible soludon , Solution tank not firmly in place . Make su;e tank is securely locked in position. , Solution tank empty Refill solution tank. To obtain approved HOOVER service and genuine HOOVER parts, locate the nearest Hoover Factory Service Center or Authorized Hoover Warranty Service Dealer (Depot) by: '_checking the Yellow Pages under "Vacuum Cleaners Household" OR , checking the list of Factory Service Centers provided with this cleaner OR , checking the Service section of The Hoover Company on-line at www.hoover.com OR , calling 1°800°944°9200 for an auto mated referral of authorized service outlet locations (U.S. only). Do not send your cleaner to The Hoover Company in North Canton for service, this will only result in delay. If further assistance is needed, contact The Hoover Company Consumer Response Center, North Canton, Ohio 44720 Phone: 1-330-499-9499. In Canada, contact Hoover Canada, Burlington, Ontario L7R 4A8, Phone: 1-800-263-6376. Always identify your cleaner by the complete model number when requesting information or ordering parts. (The model number appears at the bottom of the back of the cleaner body.) For questions or comments Machine Formula LYSOL@ concerning or OLD ENGMSH@ Floor Cleaning cal! 1-800-228-4722. Concentrate, LYSOL@ and OLD ENGMSH@ are registered trademarks of Reckitt Benckiser Inc. Possible cause Possible so/udon Excess cteaning concentrate foaming in tanks . Use Machine Formula LYSOL@ Floor Cleaning Concentrate or Machine Formula OLD ENGLISH@ Wood Floor Cleaning Concentrate, it is a low-foam formulation, if using cleaning concentrate other than L YSOL@ brand or OLD ENGLISH@ brand, remix cleaning soludon using less concentrate. , Solution tank not properly installed . Ensure that tank is installed proper/}/ (Fig. 2-15). , Recovery tank is fult . Empty tank 12 Possible cause Possible solution CJeaner set for "WET/DRY PiCKUP" . Move wet control switch down to "WET SCRUB" position (Fig. 2-7). , Circuit breaker inside cleaner is tripped . To reset the breaker. (1) Push the ON/OFF switch completely down. You will feel some resistance when the switch moves downward. The switch will also move slightly upward on its own. (2) Wait one minute. (3) Repeat step 1. (4) Turn the cleaner ON and continue cleaning. If the brushes continue to stall and the breaker tr@s again, clean the brushes to remove debris. (Figs. 4-1 through 4-4) Fuji One Year (Domestic Use) Your HOOVER@ appliance is warranted in normal household use, in accordance with the Owner's Manual against odginal defects in material and workmanship for a period of one full year from date of purchase. This warranty provides, at no cost to you, all labor and parts to place this appliance in correct operating condition during the warranted period. This warranty applies when the appliance is purchased in the United States including its territories and possessions, or in Canada or from a U. S. Military Exchange. Appliances purchased elsewhere are covered by a limited one year warranty which covers the cost of parts only. This warranty does not apply if the appliance is used in a commercial or rental application. Warranty service can only be obtained by presenting the appliance to one of the fop lowing authorized warranty service outlets. Proof of purchase will be required before service is rendered, 1. Hoover Factory Service Centers. 2. Hoover Authorized Warranty Service Dealers (Depots), For an automated referral of authorized service outmets in the U.S.A., phone 1o800o944o9200 OF( Visit 1"he Hoover Company on°line at www,hoover,com This warranty does not cover pick up, delivery, or house calls; however, if you mail your appliance to a Hoover Factory Service Center for warranty service, transportation will be paid one way. While this warranty gives you specific legal rights, you may also have other rights which vary from state to state. If further assistance is needed, or if there are questions concerning this warranty or the availability of warranty service outlets, write or phone the Consumer Response Center, The Hoover Company, 101 East Maple St., North Canton, Ohio 44720. Phone 1-330-49%9499. In Canada, contact Hoover Canada, Burlington, Ontario L7R 4A8, 1-800-263-6376. 13 14
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 14 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Thu Apr 05 01:20:13 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools