Huawei Technologies AP4130DN Wireless LAN Access Point User Manual

Huawei Technologies Co.,Ltd Wireless LAN Access Point

User Manual

     AP4130DN Quick Start Guide FCC ID: QISAP4030DN  Issue 01 Date 2015-02-06 HUAWEI TECHNOLOGY CO., LTD
AP4130DN Quick Start Guide  About This Document Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 ii  Copyright © Huawei Technologies Co., Ltd. 2015. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.   Trademarks and Permissions   and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd. All other trademarks and trade names mentioned in this document are the property of their respective holders.  Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.         Huawei Technologies Co., Ltd. Address:  Huawei Industrial Base Bantian, Longgang Shenzhen 518129 People's Republic of China Website:  http://www.huawei.com Email:  support@huawei.com
AP4130DN Quick Start Guide  About This Document Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 iii About This Document Intended Audience This document describes hardware features of the AP4130DN and provides basic installation methods. This document is intended for::  Network planning engineers  Hardware installation engineers  Commissioning engineers  Onsite maintenance engineers  System maintenance engineers   Symbol Conventions The symbols that may be found in this document are defined as follows. Symbol  Description  Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.  Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.  Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.  Indicates a potentially hazardous situation which, if not avoided, could result in equipment damage, data loss, performance deterioration, or unanticipated results. NOTICE is used to address practices not related to personal injury.  Calls attention to important information, best practices and tips.
AP4130DN Quick Start Guide  About This Document Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 iv Symbol  Description NOTE is used to address information not related to personal injury, equipment damage, and environment deterioration.  Change History Changes between document issues are cumulative. The latest document issue contains all changes made in previous issues. Issue 01 (2014-11-07) Initial commercial release
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 v Contents About This Document ................................................................................................................... iii1 Indoor AP Overview ..................................................................................................................... 61.1 Device Structure ........................................................................................................................................................... 61.2 Indicator Description .................................................................................................................................................... 71.3 Basic Specifications ...................................................................................................................................................... 91.4 Global Environmental Compliance............................................................................................................................... 92 AP Installation ............................................................................................................................. 112.1 Preparing for Installation ............................................................................................................................................ 112.2 Unpacking the Equipment .......................................................................................................................................... 122.3 Determining the Installation Position ......................................................................................................................... 132.4 Installing the AP ......................................................................................................................................................... 142.4.1 Wall Mounting ......................................................................................................................................................... 142.4.2 Ceiling Mounting ..................................................................................................................................................... 152.4.3 T-rail Mounting ........................................................................................................................................................ 162.5 Installing the Security Lock ........................................................................................................................................ 172.6 Connecting Cables ...................................................................................................................................................... 182.7 Powering on the AP .................................................................................................................................................... 193 Logging In to the AP ................................................................................................................... 203.1 Logging In to the AP Through the Console Port ......................................................................................................... 203.2 Logging In to the AP Using STelnet ........................................................................................................................... 213.3 Logging In to the AP Using a Web Client ................................................................................................................... 23
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 6 1 Indoor AP Overview About This Chapter The AP4130DN is deployed indoors and feature high reliability, high security, simple network deployment, automatic AC discovery and configuration, and real-time management and maintenance. Huawei indoor APs are especially applicable to places with simple building structure, small size, dense users, and high capacity demands, such as small-size conference rooms, bars, and leisure centers. They can be flexibly deployed according to surrounding environment.  1.1 Device Structure 1.2 Indicator Description 1.3 Basic Specifications 1.1 Device Structure Figure in Figure 1-1 shows the appearance of AP4130DN. Figure 1-1 Appearance of AP4130DN.
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 7   Table in Table 1-1 shows the interface of AP4130DN. Table 1-1 Interfaces on AP4130DN No.  Name  Description 1  2.4G/5G/Dual-band antenna  Connects a 2.4G/5G/Dual-band GHz antenna to the AP to transmit and receive service signals. 2  GE/PoE  10/100/1000M bit/s interface: connects to the wired Ethernet. The interface can connect to a PoE power supply to provide power for the AP. 3  DC power adapter  The AP supports the PoE power supply and DC power supply. To connect the AP to a DC power source, use the power adapter delivered with the AP; otherwise, the AP maybe damaged. 4  Security slot  Fasten the cable of the security lock to an immovable object around, and insert the security lock into the security slot and lock it. 1.2 Indicator Description The following information describes indicators on the AP4130DN.   The actual indicator color may vary according to temperature.  After an AP is powered on, you can run the led off command on the AC to turn off all AP indicators. To restore the indicators to normal working status, run the led on command.
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 8  The AP4130DN has indicators located inside the panel. The indicators turn on after the AP is powered on. Figure 1-2   Indicator on the AP4130DN   Table 1-2 Description of the indicator on the AP4130DN Type  Color  Status     Description Default status after power-on Green  Steady on  The AP is just powered on and the software is not started yet. Software startup status Green Steady on after blinking once After the system is reset and starts uploading the software, the indicator blinks green once. Until the software is uploaded and started, the indicator remains steady green. Running status Green Blinking once every 2s (0.5 Hz)  The system is running properly, the Ethernet connection is normal, and STAs are associated with the AP.  The system enters the Uboot CLI. Blinking once every 5s (0.2 Hz) The system is running properly, the Ethernet connection is normal, and no STA is associated with the AP. The system is in low power consumption state. Alarm Green Blinking once every0.25s (4  The software is being upgraded.    After the software is uploaded and started, the AP requests to go online on the AC and maintains this state until it goes online
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 9 Type  Color  Status     Description Hz)  successfully on the AC (before the CAPWAP link is established).  The AP fails to go online on the AC (the CAPWAP link disconnects). Fault  Red  Steady on  A fault that affects services has occurred, such as aDRAM detection failure or system software loading failure. The fault cannot be automatically rectified and must be rectified manually. 1.3 Basic Specifications Table in Table 1-3 shows the specifications of AP4130DN. Table 1-3 Basic specifications of the AP4130DN Item  Description Technical specifications Dimensions (H x W x D)  180mm×180mm×54.5mm (not include mounting bracket) Weight  0.4kg (not include mounting bracket) System memory   256MB DDR2  32 MB Flash Power specifications  Power input  12V±10%, 2A Maximum power consumption 10.2W  PoE -48V DC,0.35A Environment specifications Operating temperature 0℃~+45℃ Storage temperature -40℃~+70℃ Operating humidity  5%~95%((non-condensing) Ingress Protection Rating IP41 Atmospheric pressure 53kPa~106kPa 1.4 Global Environmental Compliance This product has been tested and complies with the following certification:
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 10  European Union RoHS: 2002/95/EC 2011/65/EU EN50581:2012  REACH: 1907/2006  WEEE: 2002/96/EC 2012/19/EU  China RoHs: SJ/T 11363-2006   本信息适用于华为在中华人民共和国销售的电子信息产品 This information applies only to Huawei Electronic Information Products sold in the People’s Republic of China. 部件名称 (Parts) 有毒有害物质或元素(Hazardous Substance) 铅 (Pb) 汞 (Hg) 镉 (Cd) 六价铬 (Cr6+) 多溴联苯 (PBB) 多溴二苯醚(PBDE) 电路模块 (circuit modules) × O O  O  O  O 电缆及电缆组件 (Cables & Cable assemblies) O O O  O  O  O 金属部件 (Metal Parts) O O O  O  O  O 塑料和聚合物部件 (Plastic and Polymeric Parts) O O O  O  O  O O: 表示该有毒有害物质在该部件所有均质材料中的含量在 SJ/T11363 - 2006 标准规定的限量要求下。 Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the SJ/T11363-2006 standard. X: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ/T11363-2006 标准规定的限量要求。 Indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant threshold of the SJ/T11363-2006 standard.  对销售之日的所售产品,本表显示华为公司供应链的电子信息产品可能包含这些物质。注意:在所售产品中可能会也可能不会含有所有所列的部件。 This table shows where these substances may be found in the supply chain of Huawei products, as of the date of sale of the enclosed product. Note that some of the component types listed above may or may not be a part of the enclosed product.
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 11 2 AP Installation About This Chapter  2.1 Preparing for Installation 2.2 Unpacking the Equipment 2.3 Determining the Installation Position 2.4 Installing the AP 2.1 Preparing for Installation This section describes safety precautions and tool preparations for AP installation. Safety Precautions  Take proper measures to prevent injuries and device damage.    Place the device in a dry and flat position away from any liquid and prevent the device from slipping.  Keep the device clean.  Do not put the device and tools in the aisles.  This device uses non-harmonized frequency and is intended for use in all European countries.   The WLAN can be operated in the EU without restriction indoors, but cannot be operated outdoors.  A 20cm separation distance needs to be maintained to ensure compliance with the European RF Exposure limits set by ICNIRP  Only the qualified personnel are permitted to install and remove the device and its accessories. Before installation and operation, read the safety precautions carefully.   Tool Preparation To install APs, prepare tools listed in Table 2-1。
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 12  Table 2-1 Tools Phillips screwdriver  (M4) Torque screwdriver   3mm/5mm  (M3-M6) Marker  ESD gloves  Utility knife  Cable cutter  Diagonal pliers  RJ45 crimping tool  Wire stripper  Network cable tester  Multimeter  Level   2.2 Unpacking the Equipment Before unpacking the carton, ensure that the packing carton is intact and not damaged or soaked. Stop unpacking if the equipment is rusted or soggy. Then, investigate causes and contact the supplier. Usually, the packing list contains the following items.  AP  Mounting Bracket  Power adapter (optional)  Quick Start Guide  Warranty card
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 13 2.3 Determining the Installation Position When determining the AP installation position, comply with the following rules:  Try to reduce the number of obstacles, such as walls, between the AP and user terminals.  Install the AP away from electronic devices that can cause radio interference, such as the microwave oven.  Install the AP in a hidden position that does not affect daily lives and work of residents.  Install the AP in a site that is free from leaking or dripping water, heavy dew, and humidity, and take protective measures to prevent water from flowing into the equipment along the cable.  Indoor APs are usually mounted on a wall or ceiling using sheet metal mounting brackets. The installation position is determined by the site survey. There must be at least 200 mm clearance between the cabling end of the AP and the wall. Figure 2-1 shows dimension and Figure 2-2 shows space requirements. Figure 2-1 Dimension of AP4130DN(Unit: mm)
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 14 Figure 2-2 Mounting an AP(Unit: mm)  2.4 Installing the AP 2.4.1 Wall Mounting 1. Fix the mounting bracket to the wall, adjust the installation position, and use the marker to mark the drilling positions where expansion screws are installed.  2. Use a 6 mm drill bit to drill 25 mm to 30 mm deep holes in the drilling positions. Hammer the expansion tubes into the holes until the expansion tubes are completely embedded into the wall.
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 15  Fix the mounting bracket to the wall and use the Phillips screwdriver to fasten three expansion screws into the expansion.  3. Align the mounting screws at the rear of the AP with the mounting holes on the mounting bracket and hang the AP on the bracket. Press the AP downwards to secure the AP on the wall.   2.4.2 Ceiling Mounting
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 16 1. Remove a ceiling tile, determine locations of mounting holes based on the distance between two installation holes on the mounting bracket, use a hammer drill to drill hole on the ceiling tile, and fix the mounting bracket to the ceiling tile.   2. Hang the AP on the mounting holes by aligning the mounting screws at the rear of the AP with the mounting screws on the bracket and push the AP horizontally to secure the AP.    The screws provided for ceiling-mounting of APs are 30 mm long and can be used to fix an AP on a ceiling not thicker than 15 mm. To install APs on thicker ceilings, you need to purchase longer screws.  Ensure that the AP is correctly installed on the mounting bracket and there must be 200 mm space above and around the AP for maintenance. 2.4.3 T-rail Mounting 1. Remove two ceiling tiles around the T-rail (1), use screws (2) to fix the adjustable buckle (3) to the mounting bracket (4), hook the adjustable buckle to the T-rail, and secure the screw on the adjustable buckle to fasten the mounting bracket and T-rail. Remove two ceiling tiles around the T-rail, use screws to fix the adjustable buckle to the mounting
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 17 bracket, hook the adjustable buckle to the T-rail, and secure the screw on the adjustable buckle to fasten the mounting bracket and T-rail.  2. Hang the AP on the mounting holes by aligning the mounting screws at the rear of the AP with the mounting screws on the bracket and push the AP horizontally to secure the AP.    1. Before fixing the adjustable buckle with a screw, you need to adjust the buckle to a proper position based on the T-rail width. 2. Ensure that the AP is correctly installed on the mounting bracket and there must be 200 mm space above and around the AP for maintenance. 2.5 Installing the Security Lock There is a security slot on the AP. You can lock the AP to an immovable object to prevent the AP against theft. The detailed procedures are as follows: 1. Fasten the cable of the security lock to an immovable object around. 2. Insert the security lock into the security slot and lock it.
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 18     You need to purchase the security lock separately. 2.6 Connecting Cables Figure 2-3 and Table 2-2 shows interface and cable connection of AP4130DN。 Figure 2-3 Interfaces of the AP4130DN  Table 2-2 Cable Connection No. Cable  Description 1 Ethernet cable   The network cables used are category-5 enhanced or higher twisted pairs.  Ensure that the AP is connected to the Ethernet using the Ethernet cable that works properly. If the Ethernet cable is not working properly, for example, RJ45 connectors are short- circuited, the AP may fail to be powered on or fail to work. Before connecting an Ethernet cable to the AP, use the cable test tool to check whether the cable is qualified. If the cable is unqualified, replace it. 2  DC power adapter     The AP supports the PoE power supply and DC power supply.  To connect the AP to a DC power source, use the power
AP4130DN Quick Start Guide  Contents Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 19 adapter delivered with the AP; otherwise, the AP maybe damaged. Pay attention to the following points when installing network cables  Before connecting an Ethernet cable to the AP, use the cable test tool to check whether the cable is qualified. If the cable is unqualified, replace it.  Do not connect the service network cable to the console port. Otherwise, the AP may be damaged when the PoE power supply is used.  Before removing network cables or power cables, remove the AP from the mounting bracket first to prevent damage to the network cables or power cables.  The cable cannot exceed 100 meters. 2.7 Powering on the AP You can check the power-on status by observing indicators on the AP. For details, see 1.2 Indicator Description  Do not frequently power on and off an AP.
AP4130DN Quick Start Guide  3 Logging In to the AP Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 20 3 Logging In to the AP About This Chapter 3.1 Logging In to the AP Through the Console Port 3.2 Logging In to the AP Using STelnet 3.3 Logging In to the AP Using a Web Client 3.1 Logging In to the AP Through the Console Port This section describes how to log in to the AP through the console port. After logging in to the AP, you can configure the AP using commands. Step 1 Connect a PC to the AP using a console cable. Connect the RJ45 connector to the console port of the AP and the DB9 connector to the serial port of a PC. Step 2 Run the terminal emulation program on the PC. For example, to open the HyperTerminal of Windows XP on the PC, choose Start > Programs > Accessories >Communications > HyperTerminal. Enter a connection name and click OK. Step 3 Select the serial port used on the PC and click OK. Step 4 Set communication parameters, click Restore Defaults, and then click OK. Step 5 Press Enter until the command line prompt of the user view, such as <Enterprise AP>, is displayed. Then, you enter the user configuration interface. (The following information is only for reference.)    The default user name and password are respectively admin and admin@huawei.com.  The password entered in interactive mode is not displayed on the screen.
AP4130DN Quick Start Guide  3 Logging In to the AP Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 21 You can run commands to configure the AP. Enter a question mark (?) whenever you need help. 3.2 Logging In to the AP Using STelnet This section describes how to log in to the AP using STelnet. After logging in to the AP, you can configure the AP using commands. Before logging in to the device through STelnet, complete the following tasks:  Starting the device properly  Preparing network cables used to connect device interfaces.   Ensuring that the IP address 169.254.1.1 and subnet mask 255.255.0.0 have been configured on VLANIF 1 of the device before the delivery and GE0/0/0 has been added to VLAN 1 by default.  Configuring the PC's IP address and subnet mask. The IP address must be on the network segment 169.254.0.0/16 but cannot be 169.254.1.1. 169.254.1.100 is recommended. The subnet mask is 255.255.0.0.  Before the device is delivered, the STelnet service has been configured on the device. The STelnet interface number is 22, and the default user name and password are respectively admin and admin@huawei.com.  Use the SSH client software to log in to the device through STelnet from a terminal. The third-party software PuTTY is used as an example here. Step 1 After the device is powered on, connect the PC's network interface to GE0/0/0 of the device using network cables  Ping 169.254.1.1 from the PC to check whether the device can be pinged successfully. If the ping operation fails, check whether the PC's IP address is correct or replace the network cable.  Step 2 Use the PuTTY software to log in to the device, enter the device IP address, and select the SSH protocol type.
AP4130DN Quick Start Guide  3 Logging In to the AP Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 22 Figure 3-1 PuTTY Configuration page  Step 3 Click Open. Enter the user name and password at the prompt, and press Enter. You have logged in to the device. (The following information is only for reference.) login as: admin  Sent username "admin"    admin@169.254.1.1's password:    <Huawei>  It is recommended that you change the initial user name and password after login.
AP4130DN Quick Start Guide  3 Logging In to the AP Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 23 3.3 Logging In to the AP Using a Web Client Pre-configuration Tasks Before configuring users to log in to the AP using HTTP, complete the following task: Configure reachable routes between the terminal and the AP.    The web management system is enabled on the AP before delivery. The default IP address of the web management system is 169.254.1.1 and the mask is 255.255.0.0. The web management system provides a default user account, with the user name admin and password admin@huawei.com. You are advised to change the user name and password on your first login. Assign your PC an IP address on the same network segment as the default IP address of the web management system, and connect the PC to the GE interface. Start the web browser on the PC and visit http://169.254.1.1 to log in to the web management system.  You can only log in to the FAT AP using the web platform. Procedure Step 1 Open a web browser on a PC, and enter the management address in the format of http://169.254.1.1 in the address bar. Ensure that the PC and AC can communicate with each other.    Then press Enter.    Set the language, user name, and password.    The HTTPS login URL is displayed in the address box indicating that the system has gone to the HTTPS login page.  You can also enter https://IP address in the address box to log in to the AP using HTTPS. HTTPS ensures security of login information during login and security of data exchanged during subsequent operations. Step 2 Click Login or press Enter. The web system home page is displayed. You can manage and maintain the equipment. For details, see the Huawei Wireless Access Points Web-based Configuration.
AP4130DN Quick Start Guide  4 Caution Issue 01 (2015-02-06)  华为专有和保密信息        版权所有 © 华为技术有限公司 24 4 Caution 4.1 Caution

Navigation menu