Huawei Technologies HG8045A EchoLife HG8045A User Manual

Huawei Technologies Co.,Ltd EchoLife HG8045A Users Manual

Users Manual

Quick Start
EchoLife HG8045A GPON Terminal
1
Safety Precautions
To use the device properly and safely, read the safety precautions carefully
before using the device and strictly observe these precautions when using
the device.
Do not look directly into the optical port without eye protection.
Keep the device out of the reach of children as the components or accessories
may be swallowed.
Install the device in strict compliance with the requirements of the supplier.
Reserve a space of at least 10 cm above and around the device for heat
dissipation. During the installation, keep the device away from electric appliances
that generate strong magnetic or electric fields, such as microwave ovens,
refrigerators, and mobile phones.
The power supply voltage of the device must meet the requirements on the input
voltage of the device.
Do not use any power adapters that are not in the standard configuration.
Otherwise, the device may be abnormal or unsafe.
Dry your hands before connecting or disconnecting cables. Stop the device and
switch off the power before connecting or disconnecting cables.
Do not place any object on the device, so that the device will not be damaged
due to overheating or deformation.
Prevent objects, such as metal, from entering the device through the heat
dissipation hole.
Switch off the power and disconnect all cables, including the power cable, optical
fiber, and network cable, during periods of lightning activities.
Do not lead the strength member of the optical fiber or other metal parts indoors.
Do not install telephone lines, network cables, power adapters or power adapter
cables outdoors. Adopting these measures will help prevent device damage and
bodily injuries which are especially prone during thunderstorms.
If an abnormality occurs, for example, liquid entering the device, smoke, unusual
sound, and smell, stop the device immediately, switch off the power, disconnect
all cables (such as the power cable, optical cable, and network cable) to the
device, and contact the authorized service center.
Do not disassemble the device without permission. In the case of a device fault,
contact the authorized service center.
Dispose of the packing materials, expired batteries, and old or abandoned
devices in accordance to local laws and regulations (recycling them is strongly
recommended).
Do not change the structure, safety design, or performance design of the device
without prior authorization.
2
Product Overview
Product Function
HG8045A 4 Ethernet ports
Wi-Fi access
Technical Specifications
NOTE
The appearance shown in this document may be different from the actual appearance of the product.
The actual product provided by the carrier prevails.
Installing the GPON Terminal
1. Do not install GPON terminals outdoors or on the outdoor cabinets.
2. GPON terminals can be mounted onto a wall or be placed on a
workbench. Do not install GPON terminals in other modes, such as the
ceiling.
3.The terminal cannot be connected to other devices such as GPON
terminals, switch and router.
The schematic diagram for placing the device on a desk horizontally is as
follows:
Item Specifications
Dimensions (L x W x H) 176 mm x 138 mm x 28 mm
Weight (including the power adapter) About 350 g
Power supply 11 - 14 V DC, 1 A
Power adapter input 100 - 240 V AC, 50 - 60 Hz
Maximum power consumption 8 W
Working temperature 0oC - +40oC
Working humidity 5% - 95% (non-condensing)
System power supply See the nameplate on the device.
3
Mounting a GPON terminal onto the wall
Step 1 Mark the positions of two holes used for mounting a GPON terminal, ensure that
the two holes have the same spacing as the two mounting holes.
Step 2 Select a proper drill according to the outer diameter of the screws. Use a
hammer drill to drill the marked positions on the wall. Then clean the wall and
install two expansion bolts.
Step 3 Use a screwdriver to fasten the screws into the expansion bolts, leaving the heads
of the screws 3 mm over the wall. Then install the GPON terminal to the screws.
4
Connecting Cables
The connections between the HG8045A and other devices are shown as follows.
1Power switch
2Optical port
3Power port
4Ethernet port
5Reset
6WLAN switch
7WPS switch
5
NOTE
1.The optical connector connected to the OPTICAL port is an SC/UPC
connector, and the type of the optical connector connected to the optical port in
the wall is determined by practical conditions.
2.To ensure normal use of fibers, make sure that the fiber bend radius is larger
than 30 mm.
Step 2 Use a network cable to connect the LAN port to a PC or the Ethernet port on
the IP STB.
Step 3 Use a power adapter to connect the POWER port to the power socket.
Step 4 Press the ON/OFF power switch.
Step 5 Press the WLAN switch to enable the Wi-Fi access function. By default, this
function is enabled.
Step 6 Press the WPS switch to enable the WPS encryption function.
The preceding figure connects the power adapter as an example. When
connecting the backup battery unit , please see the usage guide to the
backup battery for details .
NOTE
Before enabling the WPS encryption function of a GPON terminal, ensure that the
function is set in the system software in advance. After successful setting, press
the WPS switch for the settings to take effect.
NOTE
Step 1 Use an optical fiber to connect the optical port on the ONT and the optical port
on the wall. The optical port of the HG8045A is at the back of the device.
Logging in to the Web Configuration Window
Step 1 Set the IP address of the PC in the same subnet as the management
IP address of the GPON terminal. For example,
-IP address: 192.168.100.100
-Subnet mask: 255.255.255.0
Step 2 Enter the management IP address of the GPON terminal in the
address bar of Internet Explorer and press Enter.
The login window is displayed.
NOTE
The default management IP address and subnet mask of the GPON terminal
are as follows:
-IP address: 192.168.100.1
-Subnet mask: 255.255.255.0
6
NOTE
-If you do not perform any operations after logging in to the system for five
minutes, you will exit the system and the system automatically returns to the
login interface.
-The system will be locked if you input incorrect user name and password three
consecutive times. One minute later, it will be unlocked.
-Change the initial password after logging in to the web page.
Configuring Wi-Fi Parameters
Step 1 Choose the WLAN tab and choose WLAN Basic Configuration.
Step 2 In the pane, select the Enable WLAN option box. In the dialog box
that is displayed, set the basic Wi-Fi parameters, including the SSID,
authentication mode, and encryption mode. For example,
Step 3 Click Apply.
-SSID: See the nameplate on the device.
-WPA PreSharedKey: See the nameplate on the device.
SSID indicates the name of a wireless network searched by the Wi-Fi
terminal; WPA PreSharedKey indicates the authentication password for the
Wi-Fi terminal to access a wireless network.
Step 3 In the login window, select your preferred language, enter the user
name and password (default user name is root and default password
is admin), and click Login. After the password is authenticated, the
Web configuration window is displayed.
HG8045A supporting Wi-Fi, a wireless network coverage is subject to the number,
thickness, and positions of walls, materials, ceilings, or other objects that radio
signals traverse. Besides, metarial type and background radio frenquency (RF) noise
also affect the coverage of a wireless network. You can maximize the coverage of a
wireless network using the following methods:
1. Decrease the number of walls and ceilings between HG8045A and other
network devices.
Each wall or ceiling reduces the coverage of a wireless network by one to 30
meters. Install HG8045A at a proper place to avoid walls or ceilings whenever
possible.
2. Observe the straight line rule when installing network devices.
NOTE
7
Indicator Description
Table 1 Indicator status description 1
Indicator Status Description
WPS
Steady on The WPS function is enabled.
Blinking A Wi-Fi terminal is accessing the system.
Off The WPS function is disabled.
WLAN
Steady on The WLAN function is enabled.
Blinking Data is being transmitted.
Off The WLAN function is disabled.
LAN1–
LAN4
Steady on The Ethernet connection is in the normal state.
Blinking Data is being transmitted on the Ethernet port.
Off The Ethernet connection is not set up.
LOS/PON See Table 2.
POWER
Steady green The terminal is powered on.
Steady yellow The backup battery is supplying power.
Off The power supply is cut off.
The distance for which signals have to traverse at a 45° corner of two 0.5 meter-
thick walls reaches approximately one meter. To better receive signals, devices
should be installed at places where signals can directly traverse walls or ceilings.
3. Note the impact of building materials on the wireless network coverage.
A metal door or aluminum wall may limit the coverage of a wireless network.
Install access points, wireless routers, and computers, so signals can traverse
walls or open passageways. Materials and objects such as FRP products, metal
products, insulative walls, filing cabinets, bricks, and concrete weaken radio
signals.
4. When connecting ONT (such as HG8045A) to a wireless network, keep it far
from the following devices:
-Electronic devices or components that produce RF noises (keep a distance of
more than 2 meters between such a device and HG8045A.)
-2.4 GHz wireless mobile phones or X-10 devices (such as microwave ovens,
home security systems, blue-tooth devices, and refrigerators) that greatly weaken
or even eliminate radio signals. Even if a 2.4 GHz wireless mobile phone is not
connected to a wireless network, the phone base still sends signals that interfere
the wireless network.
8
The LOS indicator blinks.
If the LOS indicator blinks once two seconds, check whether the pigtail fiber
is properly connected and the connector is clean.
If the GPON terminal blinks twice a second, contact the service provider for
help.
The PON indicator is off.
Check whether the OPTICAL port and optical fiber is properly connected.
The GPON terminal fails to register with the upper-layer device. Contact the
service provider for help.
The phone does not ring upon an incoming call but communication is in
normal state when the phone is in off-hook state.
The GPON terminal provides a maximum of 60 V AC ringing current
voltage. Check whether the ringing current voltage of the phone is higher
than 60 V AC. If it is higher than 60 V AC, replace it with another phone.
How to reset the GPON terminal?
Press Reset by using a needle-type object.
How can I restore factory defaults?
Press Reset by using a needle-type object for longer than 10s to restore
factory defaults and reset the GPON terminal. If the indicator is off and then
is lit, the system restarts successfully.
FAQs
Status
No.
Status Description
PON LOS
1 Off Off The PON terminal is prohibited by the upper-layer
device, contact the service provider for help.
2Blinks twice a
second Off The GPON terminal attempts to set up a connection
with its upper-layer device.
3 Steady on Off A connection is set up between the GPON terminal
and its upper-layer device.
4 Off Blinks once
two seconds
The PON terminal is not connected to optical fibers or
does not send optical signals.
5Blinks twice a
second
Blinks twice a
second
The GPON terminal is a rogue terminal, contact the
service provider for help.
6Blinks twice a
second
Blinks once
two seconds
The Rx optical power of the PON terminal does not
within the range (–27 dBm to –8 dBm) of the Rx
sensitivity.
7Blinks once
two seconds
Blinks once
two seconds The hardware is faulty.
Table 2 Indicator status description 2
User Information
Personal or
company's full name:__________________________________________________
Address/Postal Code:_________________________________________________
Telephone:__________________________________________________________
Email:______________________________________________________________
Product Type:________________________________________________________
Product Serial Number:________________________________________________
Purchase Date:______________________________________________________
Invoice Number:______________________________________________________
Dealer's Name:______________________________________________________
Dealer's Address:_____________________________________________________
Dealer's Telephone:___________________________________________________
Warranty Card
Thank you for choosing Huawei Technologies Co., Ltd. To get better services,
please read this warranty card carefully, fill in the required information, and
preserve this card in good condition.
Preserve well. No reissue.
Dealer's Seal
Limited Warranty
Subject to the exclusions contained below, Huawei Technologies Co., Ltd. (Huawei
for short) warrants its access terminals ("Products") to be free from defects in
materials and workmanship under normal consumer usage for one year from
the date of purchase of the product ("Warranty period"). During the warranty
period, a Huawei authorized service partner shall remedy defects in materials and
workmanship free of charge.
Special Notice:
1. The warranty card shall be applicable only after being stamped by the dealer.
2. The warranty card must be preserved in good condition and free of any scratch or
alteration.
3. To claim such service for defects that are not included in the following exclusion
terms, the warranty card and the invoice that records that product serial number
shall be presented to a Huawei authorized service partner.
Special Notice:
1. The warranty card shall be applicable only after being stamped by the dealer.
2. The warranty card must be preserved in good condition and free of any scratch or
alteration.
3. To claim such service for defects that are not included in the following exclusion
terms, the warranty card and the invoice that records that product serial number
shall be presented to a Huawei authorized service partner.
Exclusions:
In any of the following cases, the warranty card becomes unenforceable or
inapplicable without prior notice:
1. The defects are caused by improper handling in transportation and assembly.
2. The defects are caused by the fact that the product is dismantled or altered by
anyone that is not from a Huawei authorized service partner.
3. The defects are caused by the fact that the product is used in a harsh environment
that is not suitable for the operation of the product.
4. The defects are caused by any force majeure including but not limited to fire,
earthquake, lightning, and tsunami.
5. The defects are caused by the fact that the product is used or handled incorrectly,
roughly or not as instructed in the applicable User Guide.
6. The normal wear and tear, including but not limited to the normal wear and tear of
the shell and the power module, shall not be covered by the limited warranty.
7. The warranty card is altered or illegible, or the product serial number recorded on
the warranty card is inconsistent with the actual one imprinted or labeled on the
product.
In any case that is not covered by this limited warranty or should the warranty expire,
Huawei shall charge for the service(s) claimed for the products if the product is still
remediable. Huawei reserves all rights to interpret this limited warranty.
Huawei Technologies Co., Ltd.
Address: Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Issue: 01(2013-12-30)
BOM number: 31506432
Qualification Card
PASS
Copyright © Huawei Technologies Co., Ltd. 2013 All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any
means without prior written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of
their respective holders.
Notice
The information in this document is subject to change without notice. Unless
otherwise stated, this guide serves only as a guide. All statements, information, and
recommendations in this document do not constitute a warranty of any kind, expressed
or implied.
FCC statement
·This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
·This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules.
·These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation.
·If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
RF exposure warning
· This equipment must be installed and operated in accordance with provided
instructions and the antenna(s) used for this transmitter must be installed to
provide a separation distance of at least 20 cm from all persons and must not be
co-located or operating in conjunction with any other antenna or transmitter.
End-users and installers must be provided with antenna installation instructions
and transmitter operating conditions for satisfying RF exposure compliance.
NOTE: THE GRANTEE IS NOT RESPONSIBLE FOR ANY CHANGES OR
MODIFICATIONS NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR
COMPLIANCE. SUCH MODIFICATIONS COULD VOID THE USERS AUTHORITY
TO OPERATE THE EQUIPMENT.
Statement
·This device PA02 doesnt support the function to modify the country code, and
the channel 12 and 13 are closed in the device PA02.

Navigation menu