HUAWEI Module
USB Interface Descriptor Guide
Issue
03
Date
2018-10-11
Copyright © Huawei Technologies Co., Ltd. 2015. All rights reserved.
No part of this manual may be reproduced or transmitted in any form or by any means without prior written
consent of Huawei Technologies Co., Ltd. and its affiliates ("Huawei").
The product described in this manual may include copyrighted software of Huawei and possible licensors.
Customers shall not in any manner reproduce, distribute, modify, decompile, disassemble, decrypt, extract,
reverse engineer, lease, assign, or sublicense the said software, unless such restrictions are prohibited by
applicable laws or such actions are approved by respective copyright holders.
Trademarks and Permissions
, , and are trademarks or registered trademarks of Huawei Technologies Co., Ltd.
Other trademarks, product, service and company names mentioned may be the property of their respective
owners.
Notice
Some features of the product and its accessories described herein rely on the software installed, capacities
and settings of local network, and therefore may not be activated or may be limited by local network
operators or network service providers.
Thus, the descriptions herein may not exactly match the product or its accessories which you purchase.
Huawei reserves the right to change or modify any information or specifications contained in this manual
without prior notice and without any liability.
DISCLAIMER
ALL CONTENTS OF THIS MANUAL ARE PROVIDED “AS IS”. EXCEPT AS REQUIRED BY APPLICABLE
LAWS, NO WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE MADE IN RELATION TO THE ACCURACY, RELIABILITY OR CONTENTS OF THIS
MANUAL.
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, IN NO EVENT SHALL HUAWEI BE
LIABLE FOR ANY SPECIAL, INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, OR LOSS OF
PROFITS, BUSINESS, REVENUE, DATA, GOODWILL SAVINGS OR ANTICIPATED SAVINGS
REGARDLESS OF WHETHER SUCH LOSSES ARE FORSEEABLE OR NOT.
THE MAXIMUM LIABILITY (THIS LIMITATION SHALL NOT APPLY TO LIABILITY FOR PERSONAL
INJURY TO THE EXTENT APPLICABLE LAW PROHIBITS SUCH A LIMITATION) OF HUAWEI ARISING
FROM THE USE OF THE PRODUCT DESCRIBED IN THIS MANUAL SHALL BE LIMITED TO THE
AMOUNT PAID BY CUSTOMERS FOR THE PURCHASE OF THIS PRODUCT.
Import and Export Regulations
Customers shall comply with all applicable export or import laws and regulations and be responsible to
obtain all necessary governmental permits and licenses in order to export, re-export or import the product
mentioned in this manual including the software and technical data therein.
Privacy Policy
To better understand how we protect your personal information, please see the privacy policy at
http://consumer.huawei.com/privacy-policy.
About This Document
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3
About This Document
Revision History
Document
Version
Date
Chapter
Descriptions
01
2014-12-27
Creation
02
2014-09-09
1
Added the description of MU709s-6,
ME909s-120 and ME909s-821.
3.4
Uppdated USB interface descriptors of
MU709s series module.
3.7
Added USB interface descriptors of
ME909s series module
03
2018-10-11
Scope
1
3.7
Added the description of ME909s- 821a.
Scope
MU509-b
MU509-g
MU509-c
MC509-a
MC509
MU609
MU709s-2
MU709s-6
ME909u-521
ME909u-523
About This Document
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4
ME909s-120
ME909s-821
ME909s-821a
HUAWEI Module
USB Interface Descriptor Guide
Contents
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5
Contents
1 Introduction.................................................................................................................................... 7
2 Interface Overview ....................................................................................................................... 9
2.1 Interface Specifications .................................................................................................................... 9
2.2 USB Descriptors Specifications........................................................................................................ 9
2.2.1 Device Descriptors .................................................................................................................. 9
2.2.2 Configuration Descriptors ...................................................................................................... 10
2.2.3 Interface Descriptors .............................................................................................................. 11
2.2.4 Endpoint Descriptors .............................................................................................................. 11
2.3 VID and PID .................................................................................................................................... 11
2.3.1 Finding out VID and PID on Windows Operating System ..................................................... 12
2.3.2 Finding out VID and PID on Linux or Android Operating System ......................................... 13
3 USB Interface Descriptors Information .................................................................................. 15
3.1 USB Interface Descriptors of MU509 Series Module ..................................................................... 15
3.1.1 On Windows XP/7 ................................................................................................................. 15
3.1.2 On Windows 8.0 or Later ....................................................................................................... 16
3.1.3 On Linux/Android ................................................................................................................... 17
3.1.4 On Other Operating Systems ................................................................................................ 17
3.2 USB Interface Descriptors of MC509 Series Module ..................................................................... 17
3.2.1 On Windows XP/7 ................................................................................................................. 17
3.2.2 On Windows 8.0 or Later ....................................................................................................... 19
3.2.3 On Linux/Android ................................................................................................................... 19
3.2.4 On Other Operating Systems ................................................................................................ 19
3.3 USB Interface Descriptors of MU609 Module ................................................................................ 19
3.3.1 On Windows XP/7 ................................................................................................................. 19
3.3.2 On Windows 8.0 or Later ....................................................................................................... 21
3.3.3 On Linux/Android ................................................................................................................... 21
3.3.4 On Other Operating Systems ................................................................................................ 24
3.4 USB Interface Descriptors of MU709s Series Module ................................................................... 24
3.4.1 On Windows XP/7 ................................................................................................................. 24
3.4.2 On Windows 8.0 or Later ....................................................................................................... 26
3.4.3 On Linux/Android ................................................................................................................... 26
3.4.4 On Other Operating Systems ................................................................................................ 28
HUAWEI Module
USB Interface Descriptor Guide
Contents
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6
3.5 USB Interface Descriptors of ME909u-521 Module ....................................................................... 28
3.5.1 On Windows XP/7 ................................................................................................................. 28
3.5.2 On Windows 8.0 or Later ....................................................................................................... 30
3.5.3 On Linux/Android ................................................................................................................... 31
3.5.4 On Other Operating Systems ................................................................................................ 33
3.6 USB Interface Descriptors of ME909u-523 Module ....................................................................... 33
3.6.1 On Windows XP/7 ................................................................................................................. 33
3.6.2 On Windows 8.0 or Later ....................................................................................................... 35
3.6.3 On Linux/Android ................................................................................................................... 36
3.6.4 On Other Operating Systems ................................................................................................ 38
3.7 USB Interface Descriptors of ME909s Series Module ................................................................... 39
3.7.1 On Windows XP/7 ................................................................................................................. 39
3.7.2 On Windows 8.0 or Later ....................................................................................................... 41
3.7.3 On Linux/Android ................................................................................................................... 42
3.7.4 On Other Operating Systems ................................................................................................ 44
4 Acronyms and Abbreviations ................................................................................................... 45
HUAWEI Module
USB Interface Descriptor Guide
Introduction
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
7
1 Introduction
This document provides the Huawei module USB interface descriptors, which is
intended to provide references for customers to develop the USB driver. If the
customer wants to integrate the module USB driver in Linux or Android system kernel
codes, we recommend the customer can directly refer to Guide to Kernel Driver
Integration in Linux for Huawei Modules.
Huawei module and the related firmware in the table below support USB interface
descriptors.
Huawei Module
Firmware Version
Remarks
MU509-b
12.815.03.01.00 or later
13.815.07.00.00 or later
-
MU509-g
12.815.03.01.00 or later
13.815.07.00.00 or later
-
MU509-c
11.815.00.78.00 or later
-
MC509-a
11.106.22.00.00 or later
Mini PCIe and LGA module have
the same USB interface
descriptors.
MC509
11.106.19.03.322 or later
Mini PCIe and LGA module have
the same USB interface
descriptors.
MU609
12.105.29.00.00 or later
Mini PCIe and LGA module have
the same USB interface
descriptors.
MU709s-2
11.651.63.00.00 or later
Mini PCIe and LGA module have
the same USB interface
descriptors.
MU709s-6
11.651.63.00.00 or later
Mini PCIe and LGA module have
the same USB interface
descriptors.
HUAWEI Module
USB Interface Descriptor Guide
Introduction
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
8
Huawei Module
Firmware Version
Remarks
ME909u-521
12.631.07.00.00 or later
Mini PCIe and LGA module have
the same USB interface
descriptors.
ME909u-523
11.430.63.00.00 or later
Mini PCIe and LGA module have
the same USB interface
descriptors.
ME909s-120
11.617.01.00.00 or later
Mini PCIe and LGA module have
the same USB interface
descriptors.
ME909s-821
11.617.01.00.00 or later
Mini PCIe and LGA module have
the same USB interface
descriptors.
ME909s-821a
11.617.08.00.00 or later
Mini PCIe and LGA module have
the same USB interface descriptors.
- Customers can send AT command "ATI" or "AT+GMR" to the module and get the firmware
version number.
- bConfigurationValue is the index to configure descriptors, and the value starts from 1.
- The ME909u-521 firmware versions before 12.631.07.00.00 do not support
bConfigurationValue=3, and some firmware versions does not have the GPS port.
- The MU709s-2 and MU709s-6 firmware versions before 11.651.63.00.00 do not support
bConfigurationValue=3.
HUAWEI Module
USB Interface Descriptor Guide
Interface Overview
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
9
2 Interface Overview
This chapter describes the Huawei module interface types and the USB descriptor
specifications.
2.1 Interface Specifications
Interface Name
Type
Value or Descriptions
MODEM
MODEM serial
port
General serial port
NDIS/ECM/NCM
Ethernet port
Modules must have NDIS as Ethernet port on
Windows XP/7, and have ECM or NCM as
Ethernet port in Linux or Android.
PCUI
General serial
port
The host application can use this port do AT
commands communication.
DIAG
General serial
port
Used for debugging.
MBIM
Ethernet port
Modules must support Windows 8.0 or later
and support MBIM port.
GPS
Serial port
Read-only serial port
2.2 USB Descriptors Specifications
2.2.1 Device Descriptors
Field
Size (Byte)
Value or Descriptions
bLength
1
Length of the device descriptor
bDescriptorType
1
Indicates it is a device descriptor type
HUAWEI Module
USB Interface Descriptor Guide
Interface Overview
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
10
Field
Size (Byte)
Value or Descriptions
bcdUSB
2
This field identifies the release of the USB
specification with which the device and its
descriptors are compliant
bDeviceClass
1
-
bDeviceSubClass
1
-
bDeviceProtocol
1
-
bMaxPacketSize0
1
-
idVendor
2
Vendor ID
idProduct
2
Product ID
bcdDevice
2
-
iManufacture
1
-
iProduct
1
-
iSerialNumber
1
-
bNumConfigurations
1
-
2.2.2 Configuration Descriptors
Field
Size (Byte)
Value or Descriptions
bLength
1
Length of the configuration descriptor
bDescriptorType
1
Indicates it is a configuration descriptor type.
wTotalLength
2
Total length of the configuration descriptor
bNumInterfaces
1
Number of interfaces supported by the
configuration
bConfigurationValue
1
The index of the configuration, the host will
use this index in the USB interface
configuration, starting from one.
iConfiguration
1
-
bmAttributes
1
-
MaxPower
1
-
HUAWEI Module
USB Interface Descriptor Guide
Interface Overview
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
11
2.2.3 Interface Descriptors
Field
Size (Byte)
Value or Descriptions
bLength
1
Length of the interface descriptor
bDescriptorType
1
Indicates it is an interface descriptor type.
bInterfaceNumber
1
Index of the interface, accumulated from 0
bAlternateSetting
1
-
bNumEndpoints
1
Endpoint number.
- For MODEM interfaces, the value is 0x03.
That is, three endpoints (Interrupt, Bulk In
and Bulk Out) are required.
- For general serial interfaces, the value is
0x02 or 0x03. That is, the Interrupt endpoint
is optional.
bInterfaceClass
1
-
bInterfaceSubClass
1
-
bInterfaceProtocol
1
-
iInterface
1
-
2.2.4 Endpoint Descriptors
Field
Size(Byte)
Value or Descriptions
bLength
1
Length of the endpoint descriptor
bDescriptorType
1
Indicates it is an endpoint descriptor type.
bEndpointAddress
1
Endpoint address
bmAttributes
1
Endpoint attributes under the configuration
selected by using the bConfigurationValue
wMaxPacketSize
2
Maximum packet size that this endpoint can
send or receive.
bInterval
1
Interval for polling endpoint for data transfers
2.3 VID and PID
This section describes how to find out Huawei module's VID and PID information.
HUAWEI Module
USB Interface Descriptor Guide
Interface Overview
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
12
- If customers take the computer with Windows operating system to do the test, please get
the Huawei module Windows driver from technical support engineers.
- If customers take the computer with Linux or Android operating system to do the test,
please refer to Guide to Kernel Driver Integration in Linux for Huawei Modules to review
and modify the kernel code, so that the module driver can be loaded in normal way.
- This section takes MU509-b module as an example for reference.
2.3.1 Finding out VID and PID on Windows Operating System
The detailed steps are shown as following.
Step 1 Connect the module and the computer with Windows operating system by the USB
cable.
Step 2 Enter Start > Computer. Right click Computer and select Manage. Then Computer
Management window will be displayed. Please refer to the red marks in the image
below. Select Device Manage and expand Ports (COM & LPT) node to find out
Huawei module serial ports.
The ports in the figure are provided only for your reference. The actual module may be
different.
Step 3 Select anyone of the Huawei module USB serial ports. Right click it and select
Properties to open the ports properties menu. This section takes Mobile Connect
3G Application Interface (COM27) port as an example.
HUAWEI Module
USB Interface Descriptor Guide
Interface Overview
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
13
Step 4 Select Details and Properties as Hardware Ids. Then customers will get the
MU509-b module's VID=0x12D1, PID=0x1001 from the Value list.
2.3.2 Finding out VID and PID on Linux or Android Operating
System
The detailed steps are shown as following.
HUAWEI Module
USB Interface Descriptor Guide
Interface Overview
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
14
Step 1 Connect the module and the computer with Linux or Android operating system by the
USB cable.
Step 2 Open the command window and run the command lsusb. Then all the devices
mounted on the USB bus will be listed. Customers can find out the Huawei module's
VID (VID=0x12D1) and PID value
Step 3 Run the command lsusb vd 12D1:PID (this PID should be the value got from the
Step 2 ), and then all the descriptors information of 12D1:PID will be listed.
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
15
3 USB Interface Descriptors Information
This chapter describes the USB interface descriptors information of Huawei module
on different operation systems. Customers can refer to that information for the
module USB driver integration development.
- This document will be updated along with the new module product releasing or the module
USB interface descriptors information updating. Please make sure to get the latest release
version.
- Please get the operation systems supportable information from modules' datasheet or the
modules' specification.
- Customers need to have a certain understanding about how the host operating system
selects the module's USB configuration, which will make it easier and more correct to use
the module USB interface information.
3.1 USB Interface Descriptors of MU509 Series Module
This section introduces the USB interface descriptors information of MU509 series
(MU509-b, MU509-c and MC509-g) module on different operation systems.
3.1.1 On Windows XP/7
The configuration of MU509 series module on Windows XP/7 is
bConfigurationValue=1, and the USB serials sequence is MODEM, DIAG and PCUI.
MU509 series module can be used only for demo test on Windows XP/7.
- MODEM serial port is used for the low-speed PS data service, including three
endpoints.
MODEM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0xFF
-
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
16
MODEM Serial Port
Field
Value
Description
bInterfaceProtocol
0xFF
-
bNumEndpoints
3
0x81: INTERRUPT IN
0x82: BULK IN
0x01: BULK OUT
- DIAG serial port is used to debug and capture trace logs, including two
endpoints.
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
1
The second interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0xFF
-
bInterfaceProtocol
0xFF
-
bNumEndpoints
2
0x83: BULK IN
0x02: BULK OUT
- PCUI serial port is used to do AT command communication with the host
application, including two endpoints.
PCUI Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0xFF
-
bInterfaceProtocol
0xFF
-
bNumEndpoints
2
0x84: BULK IN
0x03: BULK OUT
3.1.2 On Windows 8.0 or Later
MU509 series module does not support Windows 8.0 or later.
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
17
3.1.3 On Linux/Android
MU509 series module only supports bConfigurationValue=1 configuration. Please
check the USB interface descriptors details information on the Windows XP/7.
3.1.4 On Other Operating Systems
MU509 series module only supports bConfigurationValue=1 configuration. Please
check the USB interface descriptors details information on the Windows XP/7.
3.2 USB Interface Descriptors of MC509 Series Module
This section introduces the USB interface descriptors information of MC509 series
module (MC509 and MC509-a module) on different operation systems.
3.2.1 On Windows XP/7
The configuration of MC509 series module on Windows XP/7 is
bConfigurationValue=1, and the USB serials sequence is MODEM, DIAG, PCUI and
GPS.
MC509 series module can be used only for demo test on Windows XP/7.
- MODEM serial port is used for the low-speed PS data service, including three
endpoints.
MODEM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0xFF
-
bInterfaceProtocol
0xFF
-
bNumEndpoints
3
0x81: INTERRUPT IN
0x82: BULK IN
0x02: BULK OUT
- DIAG serial port is used to debug and capture trace logs, including two
endpoints.
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
1
The second interface
bInterfaceClass
0xFF
-
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
18
DIAG Serial Port
Field
Value
Description
bInterfaceSubClass
0xFF
-
bInterfaceProtocol
0xFF
-
bNumEndpoints
2
0x84: BULK IN
0x04: BULK OUT
- PCUI serial port is used to do AT command communication with the host
application, including two endpoints.
PCUI Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0xFF
-
bInterfaceProtocol
0xFF
-
bNumEndpoints
2
0x86: BULK IN
0x06: BULK OUT
- GPS serial port is used for GPS service and GPS data transfer, which has two
separate ports, including one data port with two endpoints, and one control port
with two endpoints.
GPS Serial Port
Field
Value
Description
bInterfaceNumber
3
The fourth interface, GPS data interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0xFF
-
bInterfaceProtocol
0xFF
-
bNumEndpoints
2
0x88: BULK IN
0x07: BULK OUT
bInterfaceNumber
4
The fifth interface, GPS control interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0xFF
-
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
19
GPS Serial Port
Field
Value
Description
bInterfaceProtocol
0xFF
-
bNumEndpoints
2
0x89: BULK IN
0x09: BULK OUT
3.2.2 On Windows 8.0 or Later
MC509 series module does not support Windows 8.0 or later.
3.2.3 On Linux/Android
MC509 series module only supports bConfigurationValue=1 configuration. Please
check the USB interface descriptors details information on the Windows XP/7.
3.2.4 On Other Operating Systems
MC509 series module only supports bConfigurationValue=1 configuration. Please
check the USB interface descriptors details information on the Windows XP/7.
3.3 USB Interface Descriptors of MU609 Module
3.3.1 On Windows XP/7
The configuration of MU609 module on Windows XP/7 is bConfigurationValue=1, and
the USB serials sequence is MODEM, DIAG, PCUI, GPS and NDIS.
MU609 module can be used only for demo test on Windows XP/7.
- MODEM serial port is used for the low-speed PS data service, including three
endpoints.
MODEM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x01
-
bNumEndpoints
3
0x81: INTERRUPT IN
0x82: BULK IN
0x01: BULK OUT
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
20
- DIAG serial port is used to debug and capture trace logs, including two
endpoints.
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
1
The second interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x03
-
bNumEndpoints
2
0x83: BULK IN
0x02: BULK OUT
- PCUI serial port is used to do AT command communication with the host
application, including two endpoints.
PCUI Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x02
-
bNumEndpoints
2
0x84: BULK IN
0x03: BULK OUT
- GPS serial port is used for GPS service and GPS data transfer, which has two
separate ports, including one data port with two endpoints, and one control port
with two endpoints.
GPS Serial Port
Field
Value
Description
bInterfaceNumber
3
The fourth interface, GPS data interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x05
-
bNumEndpoints
2
0x85: BULK IN
0x04: BULK OUT
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
21
GPS Serial Port
Field
Value
Description
bInterfaceNumber
4
The fifth interface, GPS control interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x06
-
bNumEndpoints
2
0x86: BULK IN
0x05: BULK OUT
- NDIS serial port is used for PS data service, including three endpoints.
NDIS Serial Port
Field
Value
Description
bInterfaceNumber
5
The sixth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x07
bNumEndpoints
3
0x87: INTERRUPT IN
0x88: BULK IN
0x06: BULK OUT
3.3.2 On Windows 8.0 or Later
MU609 module does not support Windows 8.0 or later.
3.3.3 On Linux/Android
The configuration of MU609 module on Linux/Android is bConfigurationValue=2, and
the USB serials sequence is ECM, MODEM, DIAG, PCUI and GPS.
- ECM serial port is used for PS data service, which has one control interface
including one endpoint, and one data interface including two endpoints.
ECM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface, control interface
bInterfaceClass
0x02
Communication interface class
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
22
ECM Serial Port
Field
Value
Description
bInterfaceSubClass
0x06
Ethernet control model
bInterfaceProtocol
0x00
-
bNumEndpoints
1
0x81: INTERRUPT IN
bInterfaceNumber
1
The second interface, data interface
bInterfaceClass
0x0A
Data interface class
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x00
-
bNumEndpoints
2
0x82: BULK IN
0x01: BULK OUT
- MODEM serial port is used for the low-speed PS data service, including three
endpoints.
MODEM Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x01
-
bNumEndpoints
3
0x83: INTERRUPT IN
0x84: BULK IN
0x02: BULK OUT
- DIAG serial port is used to debug and capture trace logs, including two
endpoints.
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
3
The fourth interface-
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x03
-
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
23
DIAG Serial Port
Field
Value
Description
bNumEndpoints
2
0x85: BULK IN
0x03: BULK OUT
- PCUI serial port is used to do AT command communication with the host
application, including two endpoints.
PCUI Serial Port
Field
Value
Description
bInterfaceNumber
4
The fifth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x02
-
bNumEndpoints
2
0x86: BULK IN
0x04: BULK OUT
- GPS serial port is used for GPS service and GPS data transfer, which has two
separate ports, including one data port with two endpoints, and one control port
with two endpoints.
GPS Port
Field
Value
Description
bInterfaceNumber
5
The sixth interface, GPS data interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x05
-
bNumEndpoints
2
0x87: BULK IN
0x05: BULK OUT
bInterfaceNumber
6
The seventh interface, GPS control
interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x06
-
bNumEndpoints
2
0x88: BULK IN
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
24
GPS Port
Field
Value
Description
0x06: BULK OUT
3.3.4 On Other Operating Systems
Customers need to select the correct module USB interface configuration referring to
that configuration model supported by the host system. If the host system does not
select one configuration of MU609 module actively, then the MU609 module will
enumerate the serials ports as that on Windows XP/7, which means the
bConfigurationValue=1.
3.4 USB Interface Descriptors of MU709s Series Module
This section introduces the USB interface descriptors information of MU709s series
(MU709s-2 and MU709s-6) module on different operation systems.
3.4.1 On Windows XP/7
The configuration of MU709s series module on Windows XP/7 is
bConfigurationValue=1, and the USB serials sequence is MODEM, DIAG, PCUI and
NDIS.
MU709s series module can be used only for demo test on Windows XP/7.
- MODEM serial port is used for the low-speed PS data service, including three
endpoints.
MODEM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x03
-
bInterfaceProtocol
0x01
-
bNumEndpoints
3
0x82: INTERRUPT IN
0x81: BULK IN
0x01: BULK OUT
- DIAG serial port is used to debug and capture trace logs, including two
endpoints.
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
25
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
1
The second interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x03
-
bInterfaceProtocol
0x03
-
bNumEndpoints
2
0x83: BULK IN
0x02: BULK OUT
- PCUI serial port is used to do AT command communication with the host
application, including two endpoints.
PCUI Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x03
-
bInterfaceProtocol
0x02
-
bNumEndpoints
2
0x84: BULK IN
0x03: BULK OUT
- NDIS serial port is used for PS data service, including three endpoints.
NDIS Serial Port
Field
Value
Description
bInterfaceNumber
3
The fourth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x03
-
bInterfaceProtocol
0x16
-
bNumEndpoints
3
0x86: INTERRUPT IN
0x85: BULK IN
0x04: BULK OUT
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
26
3.4.2 On Windows 8.0 or Later
The configuration of MU709s series module on Windows 8.0 or later is
bConfigurationValue=3, and the USB serial configuration is MBIM.
MU709s series module can be used only for demo test on Windows 8.0 or later.
MBIM serial port is used for PS data service on Windows 8.0 or later, which has one
control interface including one endpoint, and one data interface including two
endpoints.
MBIM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface, control interface
bInterfaceClass
0x02
Communication interface class
bInterfaceSubClass
0x0E
MBIM Port
bInterfaceProtocol
0x00
-
bNumEndpoints
1
0x82: INTERRUPT IN
bInterfaceNumber
1
The second interface, data interface
bInterfaceClass
0x0A
Data interface class
bInterfaceSubClass
0x00
-
bInterfaceProtocol
0x02
-
bNumEndpoints
2
0x81: BULK IN
0x01: BULK OUT
3.4.3 On Linux/Android
The configuration of MU709s series module on Linux/Android is
bConfigurationValue=2, and the USB serials sequence is ECM, MODEM, DIAG and
PCUI.
- ECM serial port is used for PS data service, which has one control interface
including one endpoint, and one data interface including two endpoints.
ECM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface, control interface
bInterfaceClass
0x02
Communication interface class
bInterfaceSubClass
0x06
Ethernet control model
bInterfaceProtocol
0x00
-
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
27
ECM Serial Port
Field
Value
Description
bNumEndpoints
1
0x82: INTERRUPT IN
bInterfaceNumber
1
The second interface, data interface
bInterfaceClass
0x0A
Data interface class
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x00
-
bNumEndpoints
2
0x81: BULK IN
0x01: BULK OUT
- MODEM serial port is used for the low-speed PS data service, including three
endpoints.
MODEM Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x03
-
bInterfaceProtocol
0x01
-
bNumEndpoints
3
0x84: INTERRUPT IN
0x83: BULK IN
0x02: BULK OUT
- DIAG serial port is used to debug and capture trace logs, including two
endpoints.
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
3
The fourth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x03
-
bInterfaceProtocol
0x03
-
bNumEndpoints
2
0x85: BULK IN
0x03: BULK OUT
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
28
- PCUI serial port is used to do AT command communication with the host
application, including two endpoints.
PCUI Serial Port
Field
Value
Description
bInterfaceNumber
4
The fifth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x03
-
bInterfaceProtocol
0x02
-
bNumEndpoints
2
0x86: BULK IN
0x04: BULK OUT
3.4.4 On Other Operating Systems
Customers need to select the correct module USB interface configuration referring to
that configuration model supported by the host system. If the host system does not
select one configuration of MU709s series module actively, then the MU709s series
module will enumerate the serials ports as that on Windows XP/7, which means the
bConfigurationValue=1.
3.5 USB Interface Descriptors of ME909u-521 Module
3.5.1 On Windows XP/7
The configuration of ME909u-521 module on Windows XP/7 is
bConfigurationValue=1, and the USB serials sequence is MODEM, DIAG, PCUI,
NDIS and GPS.
ME909u-521 module can be used only for demo test on Windows XP/7.
- MODEM serial port includes three endpoints. ME909u-521 module does not
support MODEM serial port to be used for data service.
MODEM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x10
-
bNumEndpoints
3
0x82: INTERRUPT IN
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
29
MODEM Serial Port
Field
Value
Description
0x81: BULK IN
0x01: BULK OUT
- DIAG serial port is used to debug and capture trace logs, including two
endpoints.
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
1
The second interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x13
-
bNumEndpoints
2
0x83: BULK IN
0x02: BULK OUT
- PCUI serial port is used to do AT command communication with the host
application, including two endpoints.
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
1
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x13
-
bNumEndpoints
2
0x83: BULK IN
0x02: BULK OUT
- NDIS serial port is used for PS data service, including three endpoints.
NDIS Serial Port
Field
Value
Description
bInterfaceNumber
3
The fourth interface
bInterfaceClass
0xFF
-
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
30
NDIS Serial Port
Field
Value
Description
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x11
-
bNumEndpoints
3
0x86: INTERRUPT IN
0x85: BULK IN
0x04: BULK OUT
- GPS serial port is used for GPS data service, including two endpoints.
GPS Serial Port
Field
Value
Description
bInterfaceNumber
4
The fifth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x14
-
bNumEndpoints
2
0x87: BULK IN
0x05: BULK OUT
3.5.2 On Windows 8.0 or Later
The configuration of ME909u-521 module on Windows 8.0 or later is
bConfigurationValue=3, and the USB serial configuration is MBIM and GPS.
ME909u-521 module can be used only for demo test on Windows 8.0 or later.
- MBIM serial port is used for PS data service on Windows 8.0 or later, which has
one control interface including one endpoint, and one data interface including
two endpoints.
MBIM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface, control interface
bInterfaceClass
0x02
Communication interface class
bInterfaceSubClass
0x0E
MBIM Port
bInterfaceProtocol
0x00
-
bNumEndpoints
1
0x82: INTERRUPT IN
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
31
MBIM Serial Port
Field
Value
Description
bInterfaceNumber
1
The second interface, data interface
bInterfaceClass
0x0A
Data interface class
bInterfaceSubClass
0x00
-
bInterfaceProtocol
0x02
-
bNumEndpoints
2
0x81: BULK IN
0x01: BULK OUT
- GPS serial port is used for GPS data service, including two endpoints.
GPS Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x14
-
bNumEndpoints
2
0x83: BULK IN
0x02: BULK OUT
3.5.3 On Linux/Android
The configuration of ME909u-521 module on Linux/Android is bConfigurationValue=2,
and the USB serials sequence is ECM, MODEM, DIAG, PCUI and GPS.
- ECM serial port is used for PS data service, which has one control interface
including one endpoint, and one data interface including two endpoints.
ECM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface, control interface
bInterfaceClass
0x02
Communication interface
bInterfaceSubClass
0x06
Ethernet control model
bInterfaceProtocol
0x00
-
bNumEndpoints
1
0x82: INTERRUPT IN
bInterfaceNumber
1
The second interface, data interface
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
32
ECM Serial Port
Field
Value
Description
bInterfaceClass
0x0A
Data interface
bInterfaceSubClass
0x00
-
bInterfaceProtocol
0x00
-
bNumEndpoints
2
0x81: BULK IN
0x01: ULK OUT
- MODEM serial port includes three endpoints. ME909u-521 module does not
support MODEM serial port to be used for data service.
MODEM Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x10
-
bNumEndpoints
3
0x84: INTERRUPT IN
0x83: BULK IN
0x02: BULK OUT
- DIAG serial port is used to debug and capture trace logs, including two
endpoints.
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
3
The fourth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x13
-
bNumEndpoints
2
0x85: BULK IN
0x03: BULK OUT
- PCUI serial port is used to do AT command communication with the host
application, including two endpoints.
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
33
PCUI Serial Port
Field
Value
Description
bInterfaceNumber
4
The fifth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x12
-
bNumEndpoints
2
0x86: BULK IN
0x04: BULK OUT
- GPS serial port is used for GPS data service, including two endpoints.
GPS Serial Port
Field
Value
Description
bInterfaceNumber
5
The sixth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x14
-
bNumEndpoints
2
0x87: BULK IN
0x05: BULK OUT
3.5.4 On Other Operating Systems
Customers need to select the correct module USB interface configuration referring to
that configuration model supported by the host system. If the host system does not
select one configuration of ME909u-521 module actively, then the ME909u-521
module will enumerate the serials ports as that on Windows XP/7, which means the
bConfigurationValue=1.
3.6 USB Interface Descriptors of ME909u-523 Module
3.6.1 On Windows XP/7
The configuration of ME909u-523 module on Windows XP/7 is
bConfigurationValue=1, and the USB serials sequence is MODEM, DIAG, PCUI,
NDIS and GPS.
ME909u-523 module can be used only for demo test on Windows XP/7.
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
34
- MODEM serial port includes three endpoints. ME909u-523 module does not
support MODEM serial port to be used for data service.
MODEM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x10
-
bNumEndpoints
3
0x82: INTERRUPT IN
0x81: BULK IN
0x01: BULK OUT
- DIAG serial port is used to debug and capture trace logs, including two
endpoints.
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
1
The second interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x13
-
bNumEndpoints
2
0x83: BULK IN
0x02: BULK OUT
- PCUI serial port is used to do AT command communication with the host
application, including two endpoints.
PCUI Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x12
-
bNumEndpoints
2
0x84: BULK IN
0x03: BULK OUT
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
35
- NDIS serial port is used for PS data service, including three endpoints.
NDIS Serial Port
Field
Value
Description
bInterfaceNumber
3
The fourth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x11
-
bNumEndpoints
3
0x86: INTERRUPT IN
0x85: BULK IN
0x04: BULK OUT
- GPS serial port is used for GPS data service, including two endpoints.
GPS Serial Port
Field
Value
Description
bInterfaceNumber
4
The fifth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x14
-
bNumEndpoints
2
0x87: BULK IN
0x05: BULK OUT
3.6.2 On Windows 8.0 or Later
The configuration of ME909u-523 module on Windows 8.0 or later is
bConfigurationValue=3, and the USB serial configuration is MBIM and GPS.
ME909u-523 module can be used only for demo test on Windows 8.0 or later.
- MBIM serial port is used for PS data service on Windows 8.0 or later, which has
one control interface including one endpoint, and one data interface including
two endpoints.
MBIM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface, control interface
bInterfaceClass
0x02
Communication interface class
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
36
MBIM Serial Port
Field
Value
Description
bInterfaceSubClass
0x0E
MBIM Port
bInterfaceProtocol
0x00
-
bNumEndpoints
1
0x82: INTERRUPT IN
bInterfaceNumber
1
The second interface, data interface
bInterfaceClass
0x0A
Data interface class
bInterfaceSubClass
0x00
-
bInterfaceProtocol
0x02
-
bNumEndpoints
2
0x81: BULK IN
0x01: BULK OUT
- GPS serial port is used for GPS data service, including two endpoints.
GPS Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x14
-
bNumEndpoints
2
0x83: BULK IN
0x02: BULK OUT
3.6.3 On Linux/Android
The configuration of ME909u-523 module on Linux/Android is bConfigurationValue=2,
and the USB serials sequence is ECM, MODEM, DIAG, PCUI and GPS.
- ECM serial port is used for PS data service, which has one control interface
including one endpoint, and one data interface including two endpoints.
ECM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface, control interface
bInterfaceClass
0x02
Communication interface class
bInterfaceSubClass
0x06
Ethernet control model
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
37
ECM Serial Port
Field
Value
Description
bInterfaceProtocol
0x00
-
bNumEndpoints
1
0x82: INTERRUPT IN
bInterfaceNumber
1
The second interface, data interface
bInterfaceClass
0x0A
Data interface class
bInterfaceSubClass
0x00
-
bInterfaceProtocol
0x00
-
bNumEndpoints
2
0x81: BULK IN
0x01: BULK OUT
- MODEM serial port includes three endpoints. ME909u-523 module does not
support MODEM serial port to be used for data service.
MODEM Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x10
-
bNumEndpoints
3
0x84: INTERRUPT IN
0x83: BULK IN
0x02: BULK OUT
- DIAG serial port is used to debug and capture trace logs, including two
endpoints.
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
3
The fourth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x13
-
bNumEndpoints
2
0x85: BULK IN
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
38
DIAG Serial Port
Field
Value
Description
0x03: BULK OUT
- PCUI serial port is used to do AT command communication with the host
application, including two endpoints.
PCUI Serial Port
Field
Value
Description
bInterfaceNumber
4
The fifth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x12
-
bNumEndpoints
2
0x86: BULK IN
0x04: BULK OUT
- GPS serial port is used for GPS data service, including two endpoints.
GPS Serial Port
Field
Value
Description
bInterfaceNumber
5
The sixth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x01
-
bInterfaceProtocol
0x14
-
bNumEndpoints
2
0x87: BULK IN
0x05: BULK OUT
3.6.4 On Other Operating Systems
Customers need to select the correct module USB interface configuration referring to
that configuration model supported by the host system. If the host system does not
select one configuration of ME909u-523 module actively, then the ME909u-523
module will enumerate the serials ports as that on Windows XP/7, which means the
bConfigurationValue=1.
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
39
3.7 USB Interface Descriptors of ME909s Series Module
This section introduces the USB interface descriptors information of ME909s series
(ME909s-120 ME909s-821 and ME909s-821a) module on different operation
systems.
3.7.1 On Windows XP/7
The configuration of ME909s series module on Windows XP/7 is
bConfigurationValue=1, and the USB serials sequence is MODEM, DIAG, PCUI,
NDIS Ctrl and Serial B.
- MODEM serial port includes three endpoints.
MODEM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x10
-
bNumEndpoints
3
0x82: INTERRUPT IN
0x81: BULK IN
0x01: BULK OUT
- DIAG serial port is used to debug and capture trace logs, including two
endpoints.
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
1
The second interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x13
-
bNumEndpoints
2
0x83: BULK IN
0x02: BULK OUT
- PCUI serial port is used to do AT command communication with the host
application, including two endpoints.
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
40
PCUI Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x12
-
bNumEndpoints
2
0x84: BULK IN
0x03: BULK OUT
- NDIS serial port is used for PS data service, including three endpoints.
NDIS Serial Port
Field
Value
Description
bInterfaceNumber
3
The fourth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x16
-
bNumEndpoints
3
0x86: INTERRUPT IN
0x85: BULK IN
0x04: BULK OUT
- Ctrl serial port is used for eCall service, including two endpoints.
User should to send eCall AT commands through this Ctrl port, which will let those eCall AT
commands are processed in higher priority.
Ctrl Serial Port
Field
Value
Description
bInterfaceNumber
4
The fifth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x06
-
bNumEndpoints
2
0x87: BULK IN
0x05: BULK OUT
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
41
- Serial B serial port is used to capture module logs and always working together
with Diag port, including two endpoints.
Serial B Port
Field
Value
Description
bInterfaceNumber
5
The sixth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x1B
-
bNumEndpoints
2
0x88: BULK IN
0x06: BULK OUT
3.7.2 On Windows 8.0 or Later
The configuration of ME909s series module on Windows 8.0 or later is
bConfigurationValue=3, and the USB serial configuration is MBIM and GPS.
- MBIM serial port is used for PS data service on Windows 8.0 or later, which has
one control interface including one endpoint, and one data interface including
two endpoints.
MBIM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface, control interface
bInterfaceClass
0x02
Communication interface class
bInterfaceSubClass
0x0E
MBIM Port
bInterfaceProtocol
0x00
-
bNumEndpoints
1
0x82: INTERRUPT IN
bInterfaceNumber
1
The second interface, data interface
bInterfaceClass
0x0A
Data interface class
bInterfaceSubClass
0x00
-
bInterfaceProtocol
0x02
-
bNumEndpoints
2
0x81: BULK IN
0x01: BULK OUT
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
42
3.7.3 On Linux/Android
The configuration of ME909s series module on Linux/Android is
bConfigurationValue=2, and the USB serials sequence is NCM, MODEM, DIAG,
PCUI, Ctrl and Serial B.
- ECM serial port is used for PS data service, which has one control interface
including one endpoint, and one data interface including two endpoints.
NCM Serial Port
Field
Value
Description
bInterfaceNumber
0
The first interface, control interface
bInterfaceClass
0x02
Communication interface class
bInterfaceSubClass
0x06
Ethernet control model
bInterfaceProtocol
0x10
-
bNumEndpoints
1
0x82: INTERRUPT IN
bInterfaceNumber
1
The second interface, data interface
bInterfaceClass
0x0A
Data interface class
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x11
-
bNumEndpoints
2
0x81: BULK IN
0x01: BULK OUT
- MODEM serial port includes three endpoints.
MODEM Serial Port
Field
Value
Description
bInterfaceNumber
2
The third interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x10
-
bNumEndpoints
3
0x84: INTERRUPT IN
0x83: BULK IN
0x02: BULK OUT
- DIAG serial port is used to debug and capture trace logs, including two
endpoints.
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
43
DIAG Serial Port
Field
Value
Description
bInterfaceNumber
3
The fourth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x13
-
bNumEndpoints
2
0x85: BULK IN
0x03: BULK OUT
- PCUI serial port is used to do AT command communication with the host
application, including two endpoints.
PCUI Serial Port
Field
Value
Description
bInterfaceNumber
4
The fifth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x12
-
bNumEndpoints
2
0x86: BULK IN
0x04: BULK OUT
- Ctrl serial port is used for eCall service, including two endpoints.
User should to send eCall AT commands through this Ctrl port, which will let those eCall AT
commands are processed in higher priority.
Ctrl Serial Port
Field
Value
Description
bInterfaceNumber
5
The sixth interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x06
-
bNumEndpoints
2
0x87: BULK IN
0x05: BULK OUT
HUAWEI Module
USB Interface Descriptor Guide
USB Interface Descriptors Information
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
44
- Serial B serial port is used to capture module logs and always working together
with Diag port, including two endpoints.
Serial B Port
Field
Value
Description
bInterfaceNumber
6
The seventh interface
bInterfaceClass
0xFF
-
bInterfaceSubClass
0x06
-
bInterfaceProtocol
0x1B
-
bNumEndpoints
2
0x88: BULK IN
0x06: BULK OUT
3.7.4 On Other Operating Systems
Customers need to select the correct module USB interface configuration referring to
that configuration model supported by the host system. If the host system does not
select one configuration of ME909s series module actively, then the ME909s series
module will enumerate the serials ports as that on Windows XP/7, which means the
bConfigurationValue=1.
HUAWEI Module
USB Interface Descriptor Guide
Acronyms and Abbreviations
Issue 02 (2015-09-09)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
45
4 Acronyms and Abbreviations
Acronym or Abbreviation
Expansion
ECM
Ethernet Control Model
GPS
Global Positioning System
MBIM
Mobile Broadband Interface Model
NDIS
Network Driver Interface Specification
PID
Product ID
PS
Packet Switched
USB
Universal Serial Bus
VID
Vendor ID

Navigation menu