Hubbell Industrial Controls, Inc.

Euclid™ Lifting Magnet Controllers

4295

Resistor Type Automatic Discharge
Specifications 4295 • March 2004 • Replaces July 1990

Features
ƒ Front-Wired Front-Removable components.
ƒ Mechanically interlocked "LIFT" and "DROP"
contactors.
ƒ Permanently connected discharge path completely independent from the line.
ƒ High-Thermal capacity resistor discharge path.
ƒ Peak magnet induced voltage limited to under
900 volts.
ƒ Long electrical contact life.
ƒ Minimum Maintenance.
ƒ Dribble feature - Standard.
ƒ Ventilated NEMA 3R Enclosure.

Description
The Euclid Type 4295 Magnet Controllers incorporate heavy duty time proven components arranged
to provide optimum control of your lifting magnets.
A mechanically rugged high thermal capacity discharge resistor assembly is permanently connected
in parallel with the magnet and provides a safe
discharge path for the stored magnetic energy.
With Euclid magnet controllers, induced volts cannot return to the line, permitting rectified power
supplies to be used without the added expense of
special protective loads or by-pass circuits.

Automatic Discharge
Type Controllers
The Euclid Type 4295 Automatic Discharge Type
Lifting Magnet Controller provides a fast and clean
release of magnet loads by applying full voltage
reverse current to the magnet. The full voltage
reverse current feature permits the operator to
promptly return for another lift.
The drop contactor is under the control of the operator's Master "Switch" and the discharge sensor
module (DSM).
When the operator's Master
"Switch" signals the magnet controller to drop the
load, the "LIFT" contactors (1L+2L) open. The
stored magnet energy is dissipated in the discharge
resistor. When the discharge voltage declines to
approximately 300 volts, the discharge sensor
module (DSM) energizes the drop relay (DR) which
in turn enables the drop contactor (D) to close applying full voltage reverse current to the magnet and
begin the adjustable time reverse current cycle.
After the completion of the timed reverse cycle the
drop relay (DR) and drop contactor (D) are de-energized.

Type Controllers
The Euclid Type 4295 Lifting Magnet Controllers
are suited for many uses from light scrap handling
to the handling of heavy billets of plates. It may be
used with all types and makes of dc lifting magnets.

Page 1 of 2

SYMBOL

FUNCTION

SYMBOL
MOV

FUNCTION

DR

DROP RELAY

SURGE SUPRESSOR

P1

POTENTIOMETER

RES1

DISCHARGE RESISTOR

CFU

CONTROL FUSE

RES2

FORCING RESISTOR (IF USED)

RFU

DROP FUSES

DSM

DISCHARGE SENSOR MODULE

D2

DIODE

D

DROP CONTACTOR

D1

RECTIFIER, MAGNET DISCHARGE
PATH

1L, 2L

LIFT CONTACTOR

Euclid™ Lifting Magnet Controller :: Resistor Type Automatic Discharge

4295

APPROXIMATE DIMENSIONS & WEIGHTS
DO NOT USE FOR CONSTRUCTION PURPOSES

CABINET OUTLINE SIZE 1, 2, 3 & 4

J2M4215

Full Voltage Controllers
CONTROLLER
SIZE

W

H

D

M

MW

MH

NET WT.

1C
1
2
3
4

16.37"
16.12"
16.12"
19.12"
19.12"

12.00"
21.90"
21.90"
27.90"
27.90"

11.00"
10.00"
10.00"
14.25"
14.25"

14.00"
24.25"
24.25"
30.25"
30.25"

9.50"
11.50"
11.50"
14.50"
14.50"

12.64"
23.00"
23.00"
29.00"
29.00"

Consult
Factory

FULL VOLTAGE MANUAL DISCHARGE TYPE
Size

System
Voltage

Control
Voltage

Magnet
Current

Part
Number

1C

300 max.

12

7.0 - 13

91911-005

Min
Cold
Magnet
Ohms
19.23

Max
Cold
Magnet
Ohm
32.86

1C

300 max.

24

7.0 - 13

91911-XXX

19.23

32.86

1C

300 max.

12

13 - 25

91911-006

10.00

17.69

1C

300 max.

24

13 - 25

91911-XXX

10.00

17.69

1

230/250

230/250

7.0 - 13

91843-202

19.23

32.86

1

230/250

230/250

13 - 25

91813-202

10.00

17.69

1

300 max.

24

13 - 25

91915-004

10.00

17.69

1

300 max.

12

13 - 25

91915-002

10.00

17.69

2

230/250

230/250

25 - 50

91814-202

5.00

9.20

2

300 max.

24

25 - 50

91877-202

5.00

9.20

PILOT DEVICES & ACCESSORIES ADDITIONS
FOR MAGNET CONTROLLER
DESCRIPTION

PART
NUMBER

"Lift-Drop" NEMA 1 enclosed Master Switch
(Standard for Euclid Lifting Magnet Controllers)

J2M4215

"Lift-Drop" NEMA 3R enclosed Master Switch

Consult Factory

Type 4211, Catalog #4211-125MISXI "Lift-Drop"
NEMA 1 Surface Mounting Master Switch

4211-99848-001

Type 4211, Catalog #4211-125MIFXI "Lift-Drop"
NEMA 1 Flush Mounting Master Switch

4211-99848-002

Type 4216, Catalog #SWPBC-MXI "Lift-Drop"
NEMA 4 Maintained Type Surface Mounting
Push Button Station

Consult Factory

2

300 max.

12

25 - 50

91877-XXX

5.00

9.20

3A

230/250

230/250

50 - 85

91815-202

2.94

4.60

3A

300 max.

24

50 - 85

91880-202

2.94

4.60

3A

300 max.

12

50 - 85

91880-XXX

2.94

4.60

HOW TO ORDER

3B

230/250

230/250

85 - 130

91816-202

1.92

2.71

Refer to Price List 4295

3B

300 max.

24

85 - 130

91863-202

1.92

2.71

3B

300 max.

12

85 - 130

91863-XXX

1.92

2.71

4

230/250

230/250

130 - 175

91817-202

1.43

1.77

4

300 max.

24

130 - 175

91861-202

1.43

1.77

4

300 max.

12

130 - 175

91861-XXX

1.43

1.77

These Pilot Devices are arranged to permit "Dribbling" when
used with Euclid Magnet Controllers.

1. Specify Magnet
Operating Circuit,
COLD.
2. Size of Controller &
Voltage

3. Magnet controller Pilot
Devices and
Accessories are
additions.
4. Order by Part Number

* Controller ampacity is based on being used with a 50% duty magnet in a 40° C ambient.

Hubbell Industrial Controls, Inc.
A subsidiary of Hubbell Incorporated

4301 Cheyenne Dr., Archdale, NC. 27262
Telephone (336) 434-2800 • FAX (336) 434-2803
http://www.hubbell-icd.com
Sales@hubbell-icd.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Encryption                      : Standard V1.2 (40-bit)
User Access                     : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res
Modify Date                     : 2004:05:10 15:06:29-03:00
Create Date                     : 2004:03:12 15:10:57-05:00
Subject                         : Specifications 4295
Page Count                      : 2
Creation Date                   : 2004:03:12 15:10:57-05:00
Mod Date                        : 2004:05:10 15:06:29-03:00
Producer                        : Acrobat Distiller 5.0 (Windows)
Author                          : Jonathan King
Metadata Date                   : 2004:05:10 15:06:29-03:00
Creator                         : Jonathan King
Title                           : Euclid™ Lifting Magnet Controllers
Description                     : Specifications 4295
Page Mode                       : UseNone
EXIF Metadata provided by EXIF.tools

Navigation menu