Hubbell Euclid Lifting Magnet Controller 4295 Users Manual Euclid™ Controllers
4295 to the manual dceca0d4-7933-479e-acd9-310a66e7d0fd
2015-02-09
: Hubbell Hubbell-Euclid-Lifting-Magnet-Controller-4295-Users-Manual-565625 hubbell-euclid-lifting-magnet-controller-4295-users-manual-565625 hubbell pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
Hubbell Industrial Controls, Inc. Euclid™ Lifting Magnet Controllers 4295 Resistor Type Automatic Discharge Specifications 4295 • March 2004 • Replaces July 1990 Features Front-Wired Front-Removable components. Mechanically interlocked "LIFT" and "DROP" contactors. Permanently connected discharge path completely independent from the line. High-Thermal capacity resistor discharge path. Peak magnet induced voltage limited to under 900 volts. Long electrical contact life. Minimum Maintenance. Dribble feature - Standard. Ventilated NEMA 3R Enclosure. Description The Euclid Type 4295 Magnet Controllers incorporate heavy duty time proven components arranged to provide optimum control of your lifting magnets. A mechanically rugged high thermal capacity discharge resistor assembly is permanently connected in parallel with the magnet and provides a safe discharge path for the stored magnetic energy. With Euclid magnet controllers, induced volts cannot return to the line, permitting rectified power supplies to be used without the added expense of special protective loads or by-pass circuits. Automatic Discharge Type Controllers The Euclid Type 4295 Automatic Discharge Type Lifting Magnet Controller provides a fast and clean release of magnet loads by applying full voltage reverse current to the magnet. The full voltage reverse current feature permits the operator to promptly return for another lift. The drop contactor is under the control of the operator's Master "Switch" and the discharge sensor module (DSM). When the operator's Master "Switch" signals the magnet controller to drop the load, the "LIFT" contactors (1L+2L) open. The stored magnet energy is dissipated in the discharge resistor. When the discharge voltage declines to approximately 300 volts, the discharge sensor module (DSM) energizes the drop relay (DR) which in turn enables the drop contactor (D) to close applying full voltage reverse current to the magnet and begin the adjustable time reverse current cycle. After the completion of the timed reverse cycle the drop relay (DR) and drop contactor (D) are de-energized. Type Controllers The Euclid Type 4295 Lifting Magnet Controllers are suited for many uses from light scrap handling to the handling of heavy billets of plates. It may be used with all types and makes of dc lifting magnets. Page 1 of 2 SYMBOL FUNCTION SYMBOL MOV FUNCTION DR DROP RELAY SURGE SUPRESSOR P1 POTENTIOMETER RES1 DISCHARGE RESISTOR CFU CONTROL FUSE RES2 FORCING RESISTOR (IF USED) RFU DROP FUSES DSM DISCHARGE SENSOR MODULE D2 DIODE D DROP CONTACTOR D1 RECTIFIER, MAGNET DISCHARGE PATH 1L, 2L LIFT CONTACTOR Euclid™ Lifting Magnet Controller :: Resistor Type Automatic Discharge 4295 APPROXIMATE DIMENSIONS & WEIGHTS DO NOT USE FOR CONSTRUCTION PURPOSES CABINET OUTLINE SIZE 1, 2, 3 & 4 J2M4215 Full Voltage Controllers CONTROLLER SIZE W H D M MW MH NET WT. 1C 1 2 3 4 16.37" 16.12" 16.12" 19.12" 19.12" 12.00" 21.90" 21.90" 27.90" 27.90" 11.00" 10.00" 10.00" 14.25" 14.25" 14.00" 24.25" 24.25" 30.25" 30.25" 9.50" 11.50" 11.50" 14.50" 14.50" 12.64" 23.00" 23.00" 29.00" 29.00" Consult Factory FULL VOLTAGE MANUAL DISCHARGE TYPE Size System Voltage Control Voltage Magnet Current Part Number 1C 300 max. 12 7.0 - 13 91911-005 Min Cold Magnet Ohms 19.23 Max Cold Magnet Ohm 32.86 1C 300 max. 24 7.0 - 13 91911-XXX 19.23 32.86 1C 300 max. 12 13 - 25 91911-006 10.00 17.69 1C 300 max. 24 13 - 25 91911-XXX 10.00 17.69 1 230/250 230/250 7.0 - 13 91843-202 19.23 32.86 1 230/250 230/250 13 - 25 91813-202 10.00 17.69 1 300 max. 24 13 - 25 91915-004 10.00 17.69 1 300 max. 12 13 - 25 91915-002 10.00 17.69 2 230/250 230/250 25 - 50 91814-202 5.00 9.20 2 300 max. 24 25 - 50 91877-202 5.00 9.20 PILOT DEVICES & ACCESSORIES ADDITIONS FOR MAGNET CONTROLLER DESCRIPTION PART NUMBER "Lift-Drop" NEMA 1 enclosed Master Switch (Standard for Euclid Lifting Magnet Controllers) J2M4215 "Lift-Drop" NEMA 3R enclosed Master Switch Consult Factory Type 4211, Catalog #4211-125MISXI "Lift-Drop" NEMA 1 Surface Mounting Master Switch 4211-99848-001 Type 4211, Catalog #4211-125MIFXI "Lift-Drop" NEMA 1 Flush Mounting Master Switch 4211-99848-002 Type 4216, Catalog #SWPBC-MXI "Lift-Drop" NEMA 4 Maintained Type Surface Mounting Push Button Station Consult Factory 2 300 max. 12 25 - 50 91877-XXX 5.00 9.20 3A 230/250 230/250 50 - 85 91815-202 2.94 4.60 3A 300 max. 24 50 - 85 91880-202 2.94 4.60 3A 300 max. 12 50 - 85 91880-XXX 2.94 4.60 HOW TO ORDER 3B 230/250 230/250 85 - 130 91816-202 1.92 2.71 Refer to Price List 4295 3B 300 max. 24 85 - 130 91863-202 1.92 2.71 3B 300 max. 12 85 - 130 91863-XXX 1.92 2.71 4 230/250 230/250 130 - 175 91817-202 1.43 1.77 4 300 max. 24 130 - 175 91861-202 1.43 1.77 4 300 max. 12 130 - 175 91861-XXX 1.43 1.77 These Pilot Devices are arranged to permit "Dribbling" when used with Euclid Magnet Controllers. 1. Specify Magnet Operating Circuit, COLD. 2. Size of Controller & Voltage 3. Magnet controller Pilot Devices and Accessories are additions. 4. Order by Part Number * Controller ampacity is based on being used with a 50% duty magnet in a 40° C ambient. Hubbell Industrial Controls, Inc. A subsidiary of Hubbell Incorporated 4301 Cheyenne Dr., Archdale, NC. 27262 Telephone (336) 434-2800 • FAX (336) 434-2803 http://www.hubbell-icd.com Sales@hubbell-icd.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Modify Date : 2004:05:10 15:06:29-03:00 Create Date : 2004:03:12 15:10:57-05:00 Subject : Specifications 4295 Page Count : 2 Creation Date : 2004:03:12 15:10:57-05:00 Mod Date : 2004:05:10 15:06:29-03:00 Producer : Acrobat Distiller 5.0 (Windows) Author : Jonathan King Metadata Date : 2004:05:10 15:06:29-03:00 Creator : Jonathan King Title : Euclid™ Lifting Magnet Controllers Description : Specifications 4295 Page Mode : UseNoneEXIF Metadata provided by EXIF.tools