PrecisionCell II M and MSH Extended Surface Mini Pleat Filters in "C" Channel Metal Frame Extended Surface Mini Pleat Filters in Metal Frame with Single 13/16" Header Bulletin PB1006-1106 General: PrecisionCell II extended surface minipleat filters now offer the end user high efficiency filtration performance in minimal media pack depths of 4 inches deep in 60-65% (MERV 11), 80-85% (MERV 13), and 90-95% (MERV 14-15), and are available in a corrosion resistant metal frame (M) for box style or optional metal frame with a single 13/16" header (MSH). Due to the rigid minipleat technology in combination with the metal frame design, PrecisionCell II's are the ideal choice for use in existing and new installations where space is limited or where upgrading filter efficiency levels are required in existing units. Variable air volume systems, turbulent airflow, or high humidity applications where conventional filters fail, are good choices for upgrading to PrecisionCell II's in metal frame configurations. PrecisionCell II 4 inch deep in M and MSH designs are designed to be operated at 500 FPM. Both M and MSH Model PrecisionCell II's are offered in all standard sizes. Special sizes are not available. All PrecisionCell II models utilize state of the art minipleat technology which uses media separators made from thermoplastic glue beads to allow precision spacing between the moisture-resistant microfine fiberglass media. The adjacent polymer bead separators cure into durable, hard strips separating the media folds thereby creating a rigid pack assembly which maintains excellent pleat spacing continuity over the life of the filter. Both PrecisionCell II metal-framed models are bonded and sealed into a corrosion-resistant, metal frame with an expanded metal face grille on the downstream side to prevent media pack oscillation or blowout. Both metal framed models are the ideal choice where HVAC Systems pull in 100% humid outside air such as Hospitals. Important Features • High Efficiency Filtration in minimal, space-saving design. • This unique shallow-depth pack compacts up to 2 times the media area found in conventional 12 inch deep filters. • 3-to-1 ratio in shipping, storage, handling and disposal costs over conventional 12" deep cells • Excellent choice for upgrading older systems at a fraction of the cost. Flanders PrecisionAire - Foremost in Air Filtration Toll Free: 1-800-637-2803 1 Construction In the Flanders Precisionaire tradition of state-of-the-art technology, PrecisionCell II filters are built with a minipleat media pack to achieve a rugged, compact lightweight, high efficiency filter. Corrosion resistant metal frame Pack sealed within frame Adhesive beads in place of metal separators allow up to 3 times the media area. Microfine glass media in your choice of filtration efficiencies 13-16” metal header on MSH models Nominal 4” PrecisionCell II Pressure Drop vs. Air Velocity Pressure Drop (in. w.g.) 1.00 90-95% 0.80 80-85% 60-65% 0.60 0.40 0.20 0.00 0 125 250 375 500 625 Air Velocity (fpm) Perfmormance values shown in this publication may be averages or estimates intended to generally represent product styles. Always contact factory for latest actual test data on specific Flanders Precisionaire models. Flanders PrecisionAire - Foremost in Air Filtration 2 Toll Free: 1-800-637-2803 Standard Box Style Nominal Size WxHxD (inches) Nominal Capacity (CFM) 90-95% Pressure Drop 80-85% 60-65% Approx. Media Area (Sq. Ft.) 12x24x4 1000 .75 .70 .55 58 16x20x4 1111 .75 .70 .55 64 16x25x4 1389 .75 .70 .55 80 18x24x4 1500 .75 .70 .55 86 20x20x4 1388 .75 .70 .55 80 20x24x4 1666 .75 .70 .55 96 20x25x4 1736 .75 .70 .55 100 24x24x4 2000 .75 .70 .55 115 Nominal Size WxHxD (inches) Nominal Capacity (CFM) 90-95% Pressure Drop 80-85% 60-65% Approx. Media Area (Sq. Ft.) 12x24x4 1000 .85 .80 .65 48 16x20x4 1111 .85 .80 .65 53 With Header 16x25x4 1389 .75 .70 .55 66 18x24x4 1500 .75 .70 .55 71 20x20x4 1388 .75 .70 .55 66 20x24x4 1666 .75 .70 .55 79 20x25x4 1736 .75 .70 .55 82 24x24x4 2000 .75 .70 .55 95 Notes 1. PD represents clean pressure drop in inches w.g. Recommended final pressure drop for all models is 1.5 inch w.g. 2. Actual filter face size of 24” x 24” and 24” x 12” is 5/8” undercut on height and width. All other sizes are 1/2” undercut on height and width. Actual filter depth is 3-3/4” 3. Efficiency is average and is based on ASHRAE Standard 52.1 and 52.2 test methods. 4. Performance tolerances conform to Section 7.4 of ARI Standard 850. 5. Perfmormance values shown in this publication may be averages or estimates intended to generally represent product styles. Always contact factory for latest actual test data on specific Flanders Precisionaire models. Prefilters VAV Systems Prefilters are always a wise choice for the protection of minipleat filters no matter what the efficiency or brand. The closely-spaced pleats are subject to face-loading (bridging) by lint and coarse particles, thus reducing their usual long life. A minimum 2530% ASHRAE efficiency pleated panel filter such as the Flanders Precisionaire Prepleat 40 is recommended. Filter banks should be sized so that the face velocity at maximum design conditions is 625 fpm or less. PrecisionCell II filters may be applied at any capacity between 0 and 625 fpm. Operating a filter bank at reduced flow will greatly increase expected filter life. Save In-Line Space Using the 24” x 24” size as an example, a carton of four PrecisionCell II 4” filters has a volume of 5.3 cubic feet and a weight of 26 lbs. Compare this to four 12” deep rigid separator-type filters packed in four cartons with a total volume of 16 cubic feet and total weight of 80 lbs. Compare the airway lengths of 22” PrecisionPak bag filters and 12” Rigid-Air filter to a 4” PrecisionCell filter when they are installed with 2” prefilters. Save Storage Space and Shipping Costs Flanders PrecisionAire - Foremost in Air Filtration Toll Free: 1-800-637-2803 3 Application Guidelines PrecisionCell II filters should be selected for new installations with 24” H x 24” W and 24” H x 12” W face sizes. These are the most widely used and stocked sizes. This allows for 12” increments in height and width of the filter bank and insures that replacement cartridges will be readily available. PrecisionCell II filters should be installed with the pleats vertical wherever possible. It is permissible to install 24” H x 12” W face size filters with pleats horizontal if necessary to meet the size requirements of the filter bank. HEPA Prefilters PrecisionCell II M and MSH Component Chart 88655. 04 20 24 MSH D Efficiency Series 89655. - 90-95% 88655. - 80-85% 86655. - 60-65% Nominal Depth 04 - 3.75” Deep Nominal Width 20 - (19-3/8”) wide Nominal Height 24 - (23-3/8”) tall Frame Style MSH - Metal w-13/16” Single Header Gasket Location D - Downstream U - Upstream V - One Vertical Side PrecisionCell II filters are ideal as prefilters for Alpha Cell HEPA filters. Their light weight and 4” depth make them an excellent choice for installation in the optional Prefilter Frame Assembly for the Alpha Cell HEPA Filter Holding Frame or in Surelock Side Access HEPA Housings. Specify the Surelock housing with an optional 4” wide prefilter track for the PrecisionCell II filters, in lieu of the 2” wide prefilter track for pleated panel filters. We recommend the selection of 80-85% PrecisionCell II filters as HEPA prefilters. Guide Specifications 1.0 General 1.1 Medium and high efficiency extended surface filters shall be PrecisionCell II (M) (MHS) minipleat panel filters as manufactured by Flanders Precisionaire. 2.3 The filter pack shall be enclosed and sealed within a corrosion-resistant metal frame. 2.4 PrecisionCell II MSH filters shall have a single 13/16” diameter header on the air entering side. 3.0 Performance 1.2 Filter sizes, efficiencies and capacities shall be as scheduled on the drawings. 3.1 Initial and final resistances shall not exceed t h e scheduled values. 1.3 Filters shall be UL 900 Class 2 listed. 3.2 Media area must equal or exceed that of the specified filter 2.0 Filter Construction 2.1 The filter pack shall be constructed of water-laid microfine fiberglass media containing a water repellent binder formed into closely spaced pleats held in position by adhesive bead separators. 3.3 The average efficiency shall be as determined by ASHRAE Standard 52.1 and 52.2 test methods. 3.4 The manufacturer shall guarantee performance as stated in the literature within tolerances as outlined in Section 7.4 of ARI Standard 850. REPRESENTED BY: Flanders PrecisionAire Foremost in Air Filtration Toll Free 1-800-637-2803 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2007:02:14 10:12:41-05:00 Modify Date : 2007:02:28 23:33:18-05:00 Producer : Acrobat Distiller 7.0 for Macintosh Mod Date : 2007:02:28 23:33:18-05:00 Creation Date : 2007:02:14 10:12:41-05:00 Author : glover Creator Tool : Adobe InDesign CS2 (4.0) Metadata Date : 2007:02:28 23:33:18-05:00 Document ID : uuid:d0f7a558-bc3d-11db-af1e-0017f203f166 Instance ID : uuid:e9696bd1-bc3e-11db-b5bb-0017f203f166 Format : application/pdf Creator : glover Title : PB1006 PCell IIM.indd Page Count : 4EXIF Metadata provided by EXIF.tools