INSTALLATION INSTRUCTIONS FOR HUNTER
CEILING FAN LIGHT KITS MODELS:

28330, 28331, 28332, 28333, 28334, 28335, 28336, 28337, 28338, 28339, 28340, 28341, 28342
28343, 28344, 28345, 28405, 28406, 28407, 28408, 28982, 28983, 28984, 28985, 28986, 28987
Light K it Lead W ires
and W ire Nuts

C AUTIONS
• Read entire text carefully before beginning installation and save these instructions.
• To reduce the risk of electrical shock, install
this light kit only on listed Hunter ceiling fan
models: C ote D’ Azur , C ustom Home 2 ,
Captiva , 44” Dominion , Designer’s Choice ,
ORBit , 52” Dominion , M arseille , Santa
Barbara , Belle Meade & Etruscan

Bellmouth Nut

Fan Speed
Switch
Capacitor

Capacitor

WARNING
• To avoid possible electrical shock, before installing light fixtures, disconnect power by
turning off the circuit breakers both to the
outlet box and to its associated wall switch
location. If you cannot lock the circuit breakers in the off position, securely f asten a
prominent warning device, such as a tag, to
the service panel.
• C onnect house wiring to the fan before attaching the light fixture to the fan.
• All wiring must be in accordance with national and local electrical codes and A NSI/
NFPA 70. If you are unfamiliar with wiring,
you should use a qualified electrician.

M ulti-wire Plug
Connection

M 3 Housing
A ssembly Screws
Reverse Switch

FIGURE 1

4. Locate and carefully remove the two capacitors
from the switch housing.
5. You have now disconnected the wiring harness
and its components from the switch housing and
are ready to install them into the modular accessory light kit.

STEP 2: INSTALLING WIRING HARNESS

STEP 1: REMOVING WIRING HARNESS

NOTE: Refer to Figure 1 for steps listed below.

Before you can install the modular accessory light
kit, you must remove the wiring harness and its components from the modular switch housing on the
fans listed above. You must then install the wiring
harness into the modular accessory light kit.

1. Locate the two wires in the lower switch housing
labeled “ Connect Light Here” or “ For Light Use” .
One will be white, the other black/white. Unscrew
the wire nuts counterclockwise to expose the bare
metal leads.

NOTE: Refer to Figure 1 for the steps listed below.

2. Locate the white wire and the black wire coming
from the light fixture.

1. Locate the reversing switch and carefully remove
the two screws holding the reversing switch to
the switch housing. The reversing switch can now
be removed from the switch housing.

Connect the black wire from the light fixture to
the black/white wire from the lower switch housing.

2. Remove the patented breakaway connector from
the fan pull chain.

Connect the white wire from the light fixture to
the white wire from the lower switch housing.

3. Carefully loosen the bellmouth nut from the fan
pull chain and remove the fan pull chain switch
from the switch housing.

To fasten the wires, twist the two bare leads together. Place a wire nut over the intertwined length
of wire and twist clockwise until tight.
41490-01 12/01/2005

W ires to Light Sockets
Bellmouth Nut

Bellmouth Nut

Fan Speed
Switch

Light Switch

Capacitor

Capacitor

M ulti-wire Plug
Connection

#6-62 Housing
A ssembly Screws
Reverse Switch

FIGURE 2

CAUTION
Be sure no bare wire or wire strands are visible after
making connections.

3. Insert the chain and fan pull chain switch through
the round opening on the side of the modular
accessory light kit. Thread the bellmouth nut over
the pull chain and hand tighten the bellmouth
nut.
4. Reattach the patented breakaway connector to
the end of the pull chain.
5. Insert the reversing switch into the square hole
on the side of the modular accessory light kit.
Install and tighten the two screws you removed
in Step 1, substep 1.
6. Carefully place the capacitors in the modular accessory light kit.
You have completed the assembly of the modular
accessory light kit and are ready for installing the
modular accessory light kit to the fan.

UPPER SW ITCH
HO USING
UPPER PLUG
CO NNECTO R

LO W ER PLUG
CO NNECTO R

LIGHT K IT

HOUSING A SSEM BLY
SCREW

FIGURE 3
2. Place the modular accessory light kit over the upper switch housing. Align the side screw holes in
the upper switch housing and the modular accessory light kit. Attach the modular accessory light
kit to the upper switch housing with the three
#6-32 X 3/8" housing assembly screws.

STEP 4: INSTALLING THE BULBS AND
GLOBES
NOTE: Refer to Figure 4 for the steps listed below.
1. Insert a globe into the cup.
2. Tighten the thumbscrews manually. Do Not
overtighten.
3. Repeat substeps 1 and 2 for the remaining three
globes.
4. Install a 60W medium base incandescent bulb into
each socket.
You have completed the installation of the modular
accessory light kit. Refer back to the “ Operating
Your Hunter Fan” section in the Installation/Owner’s
Manual provided with your Hunter fan for proper
operation instructions.

STEP 3: INSTALLING THE ACCESSORY
LIGHT KIT
NOTE: Refer to Figure 3 for the steps listed below.
1. C onnect the lower (mutli-wire) plug connector
from the modular accessory light kit to the upper plug connector from the motor.
NOTE: Both plug connectors are polarized and will
only fit together one way. Make sure that both
connectors are properly aligned before connecting them together. Incorrect connection could
cause improper operation and damage to the
product.

THUM BSCREW S
CUP

GLOBE

FIGURE 4
Hunter Fan C ompany
2500 Frisco Avenue
Memphis, TN 38114
U SA

© 2005 Hunter Fan Co.

41490-01 12/01/2005



Source Exif Data:
File Type                       : AI
File Type Extension             : ai
MIME Type                       : application/vnd.adobe.illustrator
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 2
For                             : Hunter Employee, Hunter Fan Company
Create Date                     : 12/1/2005 5:23 PM
Bounding Box                    : 34 19 578 775
Creator Version                 : 10
Container Version               : 9
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:eee44086-7d93-4946-8c2c-d7fa4f2b411a
Producer                        : Acrobat Distiller 5.0.5 (Windows)
Keywords                        : 
Modify Date                     : 2005:12:01 17:26:32-06:00
Metadata Date                   : 2005:12:01 17:26:32-06:00
Creator Tool                    : Adobe PageMaker 7.0
Document ID                     : uuid:8aebe885-a2fc-45d2-b8ae-096543ece99e
Format                          : application/pdf
Creator                         : rperkins
Title                           : 41490-01
Description                     : 41490-01
Author                          : rperkins
Subject                         : 41490-01
Image Height                    : 756
Image Width                     : 544
Image Size                      : 544x756
Megapixels                      : 0.411
EXIF Metadata provided by EXIF.tools

Navigation menu