Hunter Fan 40135 Users Manual
40135 31d50bed-01af-4d6a-b1a4-0c0c2a2bd184 Hunter Fan Thermostat 40135 User Guide |
2015-01-24
: Hunter-Fan Hunter-Fan-40135-Users-Manual-341253 hunter-fan-40135-users-manual-341253 hunter-fan pdf
Open the PDF directly: View PDF .
Page Count: 30
Download | |
Open PDF In Browser | View PDF |
Electronic/Mechanical Thermostat installation and operation manual 1 Model 40135 44017-01 04-01-2008 Our Technical Support Group is available from 8 am to 5 pm CST. They may be reached toll-free at 1-888-830-1326. 2 Table of Contents Important Information........................................ 5 Tools.................................................................. 6 Uninstalling the Existing Unit............................. 9 Installing the Thermostat................................. 12 Installing the wall plate.................................... 14 connecting the wires............................ 15 attaching the thermostat...................... 17 Operation......................................................... 20 Indicators & Adjustments................................. 22 Troubleshooting............................................... 25 Wiring Diagrams.............................................. 27 3 Electronic/Mechanical Thermostat Model 40135 Congratulations! Thank you for choosing a Hunter thermostat. Your new Hunter thermostat will provide years of reliable service and year-round energy savings. Please read this manual before beginning installation and save this booklet for complete operation instructions. 4 important information This thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – Fired Boilers Gas – Millivolt Systems Oil – Fired Boilers Oil – Fired Furnace Electric Air conditioner Electric Furnace This thermostat is not designed for heat pump systems or 110/220 V baseboard heating systems. If you are unsure what kind of heating and cooling system you have, please contact a qualified HVAC Technician for assistance. 5 Tools This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your new thermostat, you will need the following supplies: Flat-head screwdriver ...................................................................................... Small Phillips-head screwdriver ...................................................................................... Hammer ...................................................................................... Electric drill and 3/16” bit ...................................................................................... Two fresh 1.5 Volt (AA) size alkaline batteries ...................................................................................... 6 NOTICE! Do not disconnect the wires from the existing thermostat before reading these instructions. The wires must be labeled prior to removal to ensure proper reconnection. 7 W RC Y G RC Y G W 8 uninstalling the existing unit 1. Turn the system power OFF from the existing thermostat. Turn the power to the HVAC system OFF at the main power panel or at the furnace. 2. Remove the existing thermostat cover to access the wires from the wall. (Some thermostats may have multiple covers, screws or other locking devices that must be removed or disengaged.) 3. Locate, but do not disconnect the wires. (If wires are not visible, they may be connected to the back of the wall plate. Some models may have doors that open to expose the wires and mounting screws.) 9 label the wire with this sticker: 24 Volt 24 Volt Cool rc / vc RH RC RH / r / vr / 4 RH If your existing thermostat is marked... RC heating g/f fan * See pg 27 for complete wiring diagram. 10 W G w/h Y W air conditioning compressor Y y / c* / m G uninstalling the existing unit, cont. 4. Using the provided stickers, label each wire according to the chart. (If the terminals are not labeled, contact a qualified HVAC technician.) W G W RC Y Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identification. *If a wire marked C is present, C may be a Common wire and should not be used. If you have a wire marked C, do not connect it to any terminal. This wire is used only for non-battery powered thermostats. 5. Do not let the wires slip back into the wall during disconnection. You may want to secure the wires to the wall as you disconnect them. After all wires are labeled, disconnect each wire and remove the existing wall plate. 11 installing the thermostat INSTALLING THE THERMOSTAT 1. Remove the new thermostat from the back plate by pulling the two halves apart. Wall Plate Thermostat 12 W G RC Y 13 installing the thermostat, cont. INSTALLING THE WALL PLATE 2. Position the new wall plate on the wall and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter wall plate, or if there are no existing holes, level the wall plate and mark the wall for two holes. 4. Remove the wall plate and drill two 3/16” holes where marked. 5. Tap the plastic anchors into the holes until they are flush with the wall. 6. Reposition the wall plate on the wall, pulling the wires through the opening. Insert the mounting screws through the mounting holes and into the anchors. Verify that the thermostat is visually level and securely tighten both screws. 14 Y RC G RH W 15 installing the thermostat, cont. CONNECTING THE WIRES 1. Loosen, but do not remove, the terminal screws. Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper. If you do not have both an RH and RC wire, leave the jumper in place. 2. Match and connect the wires from the wall to the terminals as shown. Wires should be inserted behind the black terminal shields. Tighten each screw after the connection has been made. (The ends of any extra wires should be wrapped in electrical tape and carefully pushed back into the wall.) 3. Push any excess wire length back into the wall to prevent interference. 16 HE/HG Switch HG 17 HE installing the thermostat, cont. ATTACHING THE THERMOSTAT 4. Locate the HE/HG switch on the back of the thermostat. Set the switch to HG for a gas furnace or oil burner. Set the switch to HE for electric furnaces. (The switch has no effect when the system is set to cooling mode.) 5. Insert two fresh AA alkaline batteries. 6. Align the thermostat with the the wall plate, and snap the two halves together. 7. Restore power at the electrical panel or furnace. 18 19 Thermometer Set Temperature Slider System Switch SYSTEM COOL OFF HEAT AUTO ON Fan Switch 90 90 80 70 60 50 F 30 60 10 50 C F Battery Indicator 20 80 70 20 Operation 1. Set the Set Temperature slider to the desired temperature. 2. The System Switch determines the operating mode of the thermostat. Select Cool, Off, or Heat. 3. The Fan Switch should normally be located in the Auto position. To run the fan continuously, slide the Fan Switch to the On position. Note: In Auto , The fan will be turned on along with normal operation of your system. In a normal gas or oil furnace, the fan will be turned on by your furnace after its warm-up delay. 21 indicators and adustment 1. The Thermometer indicates the room temperature. 2. The Battery Indicator displays two stages of battery conditions. The first warning is the Weak Battery Warning, indicated by the Battery Indicator flashing once approximately every second. When this warning appears, install two fresh AA alkaline batteries at your earliest convenience. 3. The second warning is the Shut-down Indicator, indicated by the Battery Indicator flashing approximately twice every second. When this warning appears, the thermostat is shut down and will turn your system OFF. Your system will remain shut-off until you install two fresh AA alkaline batteries. 22 Span Adjust 23 SPAN Indicators and Adjustments, cont. Your thermostat is preset to cycle your system off and on at 1oF above and below the Set Temperature. For maximum system efficiency and a sustained comfortable temperature your system should cycle 3 - 5 times per hour. If your system is cycling either too often or not often enough, then use a small Phillips-head screwdriver to turn the Span Adjust left or right to change the cycle time. 1. Remove the top cover from the thermostat. 2. To make your system run LONGER, turn the Span Adjust clockwise. 3. To make your system run SHORTER, turn the Span Adjust counter clockwise. 4. Reattach the top cover to the thermostat. Note: The Span range is 0.6oF - 3oF. The Span setting remains the same in both the Heat and Cool modes and can be changed regardless of what position the System Switch is in. 24 1. My heating or cooling will not turn on or off. 1 a. Check the HE/HG switch to ensure it is set to the correct position. 1 b. Wait. There may be as much as a 4-minute delay before the system turns on or off to protect the compressor. 1 c. Check the circuit breakers and switches to ensure there is enough power to the system. 1 d. Replace the batteries with fresh AA alkaline batteries. 1 e. If applicable, make sure the furnace blower door is closed properly. 1 f. If your system has 4 wires, ensure the jumper wire is installed between the RC and RH terminals. ...................................................................................... 2. My system continues to operate when the thermostat is in the off position. 2 a. Replace unit. 25 troubleshooting Is there help on the web? Yes. Visit http://www.hunterfan.com for more information. .................................................................................... ......... Can’t I just call someone? Sure. Our Technical Support Group is available from 8 am to 5 pm CST. They may be reached toll-free at1-888-8301326. 26 4-wire Heat/Cool System G Rh Fan Relay Heat/Cool 24V Supply Y Cool Contactor W Heat Relay or Valve 5-wire Heat/Cool System G Rc Rh Fan Relay Cool 24V Supply Heat 24V Supply 27 Y Cool Contactor W Heat Relay or Valve wiring diagrams 2-wire Heat Only System Rh Heat 24V or Millivolt Supply W Heat Relay or Valve 3-wire Heat Only System G Fan Relay Rh Heat 24V Supply 28 W Heat Relay or Valve wiring diagrams, cont. 3-wire Cool Only System G Fan Relay Rc Y Cool 24V Supply 29 Cool Contacter 30 © 2007 Hunter Fan Company
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24 Create Date : 2008:05:02 09:24:41-05:00 Modify Date : 2008:05:02 09:25:01-05:00 Metadata Date : 2008:05:02 09:25:01-05:00 Creator Tool : Adobe InDesign CS3 (5.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 11235 bytes, use -b option to extract) Version ID : 1 Instance ID : uuid:287fb216-33b3-45c6-a040-c9da4b53e83c Document ID : adobe:docid:indd:fe85a9e8-0040-11dd-bb0f-d831baa1d531 Rendition Class : proof:pdf Derived From Instance ID : fe85a9e7-0040-11dd-bb0f-d831baa1d531 Derived From Document ID : adobe:docid:indd:fe85a9e6-0040-11dd-bb0f-d831baa1d531 Derived From Version ID : 1 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Y Resolution : 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:1C28FB482E22DB11A91E82F9EDB87DB8, uuid:1C28FB482E22DB11A91E82F9EDB87DB8, uuid:942A4F352900DD11B2108E95FC8ED956, uuid:AE96E48F8B01DD11B449CE5283071B2B, uuid:545D0CB32A00DD11B2108E95FC8ED956, uuid:E4C8FBB85018DD1191D6FC8818FA7514, uuid:942A4F352900DD11B2108E95FC8ED956, uuid:79A9A31E2A00DD11B2108E95FC8ED956, uuid:E4C8FBB85018DD1191D6FC8818FA7514, uuid:FF2E957A7C05DD11AC809D876D07EDDF, uuid:002F957A7C05DD11AC809D876D07EDDF, uuid:D03F270C7D05DD11AC809D876D07EDDF, uuid:CE129B407B05DD118170E383587616FB Manifest Reference Document ID : uuid:1B28FB482E22DB11A91E82F9EDB87DB8, uuid:1B28FB482E22DB11A91E82F9EDB87DB8, uuid:932A4F352900DD11B2108E95FC8ED956, uuid:AD96E48F8B01DD11B449CE5283071B2B, uuid:82A9A31E2A00DD11B2108E95FC8ED956, uuid:E3C8FBB85018DD1191D6FC8818FA7514, uuid:932A4F352900DD11B2108E95FC8ED956, uuid:78A9A31E2A00DD11B2108E95FC8ED956, uuid:E3C8FBB85018DD1191D6FC8818FA7514, uuid:FE2E957A7C05DD11AC809D876D07EDDF, uuid:C6129B407B05DD118170E383587616FB, uuid:C8129B407B05DD118170E383587616FB, uuid:CA129B407B05DD118170E383587616FB Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 30 Creator : Adobe InDesign CS3 (5.0)EXIF Metadata provided by EXIF.tools