Hunter Fan TX35 Fan Remote Control User Manual Casa Controls Platform Specification Rev3

Hunter Fan Company Fan Remote Control Casa Controls Platform Specification Rev3

User Manual

Download: Hunter Fan TX35 Fan Remote Control User Manual Casa Controls Platform Specification Rev3
Mirror Download [FCC.gov]Hunter Fan TX35 Fan Remote Control User Manual Casa Controls Platform Specification Rev3
Document ID1784535
Application ID1qTjLgiy1bzLBuDUd9xTQA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize9.72kB (121446 bits)
Date Submitted2012-09-06 00:00:00
Date Available2012-09-06 00:00:00
Creation Date2012-09-06 11:47:55
Producing SoftwareGPL Ghostscript 9.02
Document Lastmod2012-09-06 11:47:55
Document TitleCasa Controls Platform Specification_Rev3
Document CreatorPDFCreator Version 1.2.2
Document Author: rbianco

Confidential
FUNCTIONAL SPECIFICATION
Remote Fan &
Light Control
Page 1
65535
65536
Receiver
Hunter Fan Company Confidential
Hunter Fan Company Confidential
I. General Description
Transmitter
7 buttons (fan speed
OFF, 1, 2, 3, 4, light
Up, Down button) + 1
slide switch for
Reverse.
Blue LED x 1.
9 buttons (fan speed
OFF, 1, 2, 3, 4,
Reverse, light Up,
Down, Power button).
Hunter Fan Company Confidential
Battery
Feature
TBD
TBD
120V/60Hz
Learning code,
Fan speed 1,2,3, off.
Light on, off, dimming.
SCP,
Safe Exit,
Light type autodetection,
190w limiter (optional).
Terminal
5 wires
interface
(L, N, Fan
output,
DownLight
output,
Common)
6 wires
interface
(L, N, Fan
output,
DownLight
output,
Uplight
output,
Common)
3 wires
interface
(Live in,
Live out,
Ground)
TBD
Hu
7 buttons (fan speed
OFF, 1, 2, 3, 4, light
Up, Down button).
Blue LED x 1.
Housing
color
DC 3V CR2032battery
Feature
Receiver
III. Functional Specifications
Receiver :
•
1. Fan Control – A Total of 4 Speed Buttons and one OFF
button on side shall be used to initiate Fan Control functions.
a) OFF Function: A Press/Release of the “Fan OFF” button
on side shall turn the fan OFF.
b) Four Speed Motor Control: 1, 2, 3 & 4 represents fan
speed from low to high.
2.
L i ght i n g C o nt rol – I n or de r t o re d uc e co m pl e xi t y i n
manufacturing and standardize to one version of firmware, an uplight detection routine is included in firmware that is run each time
the power is cycled to the receiver. A very brief flash will be seen
on the up-light during this time. If there IS an up-light detected
then:
a) the button on the transmitter with the up arrow will serve
as the dimmer and the ON/OFF button for the up-light. A
momentary press will change the state of the up-light. A
press and hold will begin to increase lumen output of the
up-light. A release followed by another press and hold will
continue to increase lumen output of the up-light up to
100%. Continuing to hold the button with the up arrow will
cause the lumen output to jump from 100% to 10% and
continue increasing. Full one way cycle will last 8 seconds.
b) the button on the transmitter with the down arrow will
serve as the dimmer and the ON/OFF button for the downlight. A momentary press will change the state of the
down-light. A press and hold will begin to decrease lumen
output of the down-light. A release followed by another
press and hold will decrease lumen output of the down-light
to 10%. Continuing to hold the button with the down arrow
will cause the lumen output of the down-light to jump from
10% to 100% and then back down. Full one way cycle will
last 8 seconds.
c) If there is NOT an up-light detected then a momentary
Hunter Fan Company Confidential
push of either light button will change the state of the downlight. A press and hold of either light button will increase or
decrease lumen level as described above
3. Transmit LED Indicator – A small blue LED shall be
used to visually display Fan, Lighting Control, Safe Exit and
Learning Mode commands initiated by pressing the appropriate
buttons.
4. CFL and Incandescent Control Mode – The unit shall
automatically detect for the presence of CFL or incandescent
bulbs. Once the presence of CFL bulbs is established, the
dimming functions will be disabled and the Down-light buttons
will turn the lights on and off only.
5. Electrical Disturbance Feature – The lights and fan shall
power up in the state they were in before the Power On Reset
including lighting level and fan speed.
6. Learning Mode - This feature shall be initiated by cycling the
power to the fan. For 3 minutes after cycling power to the fan the
pairing operation can be implemented on the handheld remote
whereby pressing both HIGH & OFF (4 & 0) Fan Speed Buttons
for at least 3 seconds shall send an encoded binary bit message
to a target receiver-controller. The Transmit LED Indicator shall
flash 3 times and the fan shall turn at the lowest speed signifying
the Learning Process is completed. The lights shall not change
state during this operation.
7.
Safe Exit Mode– This feature shall allow egress from a
room with a time delay –OFF light source. To initiate the Safe
Exit feature, the following steps shall be embedded within the
handheld remote and receiver-controllers microcontrollers’
memory. The Safe Exit Mode operation shall be explained for
Hunter Fan Company Confidential
both Incandescent and CFL based bulbs. This shall not affect
fan operation.
a) Incandescent Lighting: Press of the fan OFF Button on
the handheld remote for at least 3 seconds shall initiate the
Safe Exit Mode.
(1) The Ceiling Fan Down-lights and the LED on the
handheld remote shall flash 2 times for visual
confirmation.
(2) The down-lights shall stay ON 50% brightness for
20 seconds and then begin to dim. After a total of 30
seconds has elapsed, the down-lights shall be OFF
completely.
(3) To cancel the Safe-Exit program while it is
running, either Down-light Control Button shall be
pressed for 3 seconds.
b) CFL Lighting
(1) Press of the fan OFF button on the handheld
remote for at least 3 seconds shall initiate the Safe
Exit Mode. The Ceiling Fan Down-lights and the LED
on the handheld remote shall flash 2 times for visual
confirmation
(2) The Down-lights shall stay ON 100% brightness
for 30 seconds. After 30 seconds has elapsed, the
down-lights shall be completely OFF.
(3) To cancel the Safe-Exit program while it is
running, either Down-light Control Button shall be
pressed for 3 seconds.
Hunter Fan Company Confidential
B. TRANSMITTER
1. Fan Control – A Total of 4 Speed Buttons and one OFF
button on side shall be used to initiate Fan Control functions.
a) OFF Function: A Press/Release of the “Fan OFF” button
on side shall turn the fan OFF.
b) Four Speed Motor Control: 1, 2, 3 & 4 represents fan
speed from low to high.
2. Lighting Control – In order to reduce complexity in
manufacturing and standardize to one version of firmware, an
up-light detection routine is included in firmware that is run
each time the power is cycled to the receiver. A very brief
flash will be seen on the up-light during this time. If there IS
an up-light detected then:
a) the button on the transmitter with the up arrow will serve
as the dimmer and the ON/OFF button for the up-light. A
momentary press will change the state of the up-light. A
press and hold will begin to increase lumen output of the uplight. A release followed by another press and hold will
continue to increase lumen output of the up-light up to 100%.
Continuing to hold the button with the up arrow will cause the
lumen output to jump from 100% to 10% and continue
increasing. Full one way cycle will last 8 seconds.
b) the button on the transmitter with the down arrow will
serve as the dimmer and the ON/OFF button for the downlight. A momentary press will change the state of the downlight. A press and hold will begin to decrease lumen output
of the down-light. A release followed by another press and
hold will decrease lumen output of the down-light to 10%.
Continuing to hold the button with the down arrow will cause
the lumen output of the down-light to jump from 10% to
100% and then back down. Full one way cycle will last 8
seconds.
c) If there is NOT an up-light detected then a momentary
push of either light button will change the state of the down-
light. A press and hold of either light button will increase or
decrease lumen level as described above
Hunter Fan Company Confidential
3. Fan Spinning Direction Reverse A small slide switch
shall be used to activate the fan spinning direction reverse.
–
4. Transmit LED Indicator A small blue LED shall be
used to visually display Fan, Lighting Control, Safe Exit and
Learning Mode commands initiated by pressing the appropriate
buttons.
–
5. CFL and Incandescent Control Mode The unit shall
automatically detect for the presence of CFL or incandescent
bulbs. Once the presence of CFL bulbs is established, the
dimming functions will be disabled and the Up-light & Down-light
buttons will turn the lights on and off only.
–
6. Electrical Disturbance Feature The lights and fan shall
power up in the state they were in before the Power On Reset
including lighting level and fan speed.
–
7. Learning Mode - This feature shall be initiated by cycling the
power to the fan. For 3 minutes after cycling power to the fan the
pairing operation can be implemented on the handheld remote
whereby pressing both HIGH & OFF (4 & 0) Fan Speed Buttons
for at least 3 seconds shall send an encoded binary bit message
to a target receiver-controller. The Transmit LED Indicator shall
flash 3 times and the fan shall turn at the lowest speed signifying
the Learning Process is completed. The lights shall not change
state during this operation.
Hunter Fan Company Confidential
8.
Safe Exit Mode– This feature shall allow egress from a
room with a time delay –OFF light source. To initiate the Safe
Exit feature, the following steps shall be embedded within the
handheld remote and receiver-controllers microcontrollers’
memory. The Safe Exit Mode operation shall be explained for
both Incandescent and CFL based bulbs. This shall not affect
fan operation.
a) Incandescent Lighting: Press of the fan OFF Button on
the handheld remote for at least 3 seconds shall initiate the
Safe Exit Mode.
(1) The Ceiling Fan Down-lights and the LED on the
handheld remote shall flash 2 times for visual
confirmation.
(2) The down-lights shall stay ON 50% brightness for
20 seconds and then begin to dim. After a total of 30
seconds has elapsed, the lights shall be OFF
completely.
(3) To cancel the Safe-Exit program while it is
running, either Down-light Control Button shall be
pressed for 3 seconds.
b) CFL Lighting
(1) Press of the fan OFF button on the handheld
remote for at least 3 seconds shall initiate the Safe
Exit Mode. The Ceiling Fan Down-lights and the LED
on the handheld remote shall flash 2 times for visual
confirmation
(2) The Down-lights shall stay ON 100% brightness
for 30 seconds. After 30 seconds has elapsed, the
lights shall be completely OFF.
(3) To cancel the Safe-Exit program while it is
running, either Down-light Control Button shall be
pressed for 3 seconds.
Hunter Fan Company Confidential
C. Wall Control
1. Fan Control – A Total of 4 Speed Buttons and one OFF
button shall be used to initiate Fan Control functions.
a) OFF Function: A Press/Release of the “Fan OFF” button
shall turn the fan OFF.
b) Four Speed Motor Control: 1, 2, 3 & 4 represents fan
speed from low to high.
2. Lighting Control – In order to reduce complexity in
manufacturing and standardize to one version of firmware, an
up-light detection routine is included in firmware that is run each
time the power is cycled to the receiver. A very brief flash will
be seen on the up-light during this time. If there IS an up-light
detected then:
a) the button on the transmitter with the up arrow will serve
as the dimmer and the ON/OFF button for the up-light. A
momentary press will change the state of the up-light. A
press and hold will begin to increase lumen output of the
up-light. A release followed by another press and hold will
continue to increase lumen output of the up-light up to
100%. Continuing to hold the button with the up arrow will
cause the lumen output to jump from 100% to 10% and
continue increasing. Full one way cycle will last 8 seconds.
b) the button on the transmitter with the down arrow will
serve as the dimmer and the ON/OFF button for the downlight. A momentary press will change the state of the
down-light. A press and hold will begin to decrease lumen
output of the down-light. A release followed by another
press and hold will decrease lumen output of the down-light
to 10%. Continuing to hold the button with the down arrow
will cause the lumen output of the down-light to jump from
10% to 100% and then back down. Full one way cycle will
last 8 seconds.
c) If there is NOT an up-light detected then a momentary
push of either light button will change the state of the down-
light. A press and hold of either light button will increase or
decrease lumen level as described above
Hunter Fan Company Confidential
10
3. Fan Spinning Direction Reverse – A small slide switch shall
be used to activate the fan spinning direction reverse.
4. CFL and Incandescent Control Mode – The unit shall
automatically detect for the presence of CFL or incandescent
bulbs. Once the presence of CFL bulbs is established, the
dimming functions will be disabled and the Up-light & Down-light
buttons will turn the lights on and off only.
5. Electrical Disturbance Feature – The lights and fan shall
power up in the state they were in before the Power On Reset
including lighting level and fan speed.
6. Learning Mode - This feature shall be initiated by cycling the
power to the fan. For 3 minutes after cycling power to the fan the
pairing operation can be implemented on the wall control
whereby pressing both HIGH & OFF (4 & 0) Fan Speed Buttons
for at least 3 seconds shall send an encoded binary bit message
to a target receiver-controller. The Transmit LED Indicator shall
flash 3 times and the fan shall turn at the lowest speed signifying
the Learning Process is completed. The lights shall not change
state during this operation.
7.
Safe Exit Mode– This feature shall allow egress from a
room with a time delay –OFF light source. To initiate the Safe
Exit feature, the following steps shall be embedded within the
handheld remote and receiver-controllers microcontrollers’
memory. The Safe Exit Mode operation shall be explained for
both Incandescent and CFL based bulbs. This shall not effect
fan operation.
a) Incandescent Lighting: Press of the fan OFF Button on
the wall control for at least 3 seconds shall initiate the Safe
Exit Mode.
(1) The Ceiling Fan Down-lights shall flash 2 times for
visual confirmation.
Hunter Fan Company Confidential
11
(2) The down-lights shall stay ON 50% brightness for
20 seconds and then begin to dim. After a total of 30
seconds has elapsed, the lights shall be OFF
completely.
(3) To cancel the Safe-Exit program while it is
running, either Down-light Control Button shall be
pressed for 3 seconds.
b) CFL Lighting
(1) Press of the fan OFF button on the handheld
remote for at least 3 seconds shall initiate the Safe
Exit Mode. The Ceiling Fan Down-lights shall flash 2
times for visual confirmation
(2) The Down-lights shall stay ON 100% brightness
for 30 seconds. After 30 seconds has elapsed, the
lights shall be completely OFF.
(3) To cancel the Safe-Exit program while it is
running, either Down-light Control Button shall be
pressed for 3 seconds.
Hunter Fan Company Confidential
12
.
V. RF Specifications
A. The operating RF (Radio Frequency) for the Transmitter shall be 433MHz.
B. The remote controls transmission circuit shall use a SAW (Surface Acoustic
Wave) resonator or an equivalent RF Digital IC.
Hunter Fan Company Confidential
13
Confidential
PRODUCT SPECIFICATION
Casa Platform Remote Fan &
Light Control
Models: 65535, 65536, 65537
Page 19 of 20
Rev. 3
18Jan12
Written by:
Shain Breland
2. Date code: WWYY. The date code is located in a clearly
visible location.
XIV. Engineering Changes
Any changes need to be requested according to the latest revision of
Hunter Fan Company engineering document QA R&D-5 for ECRs.
XV. Critical Components
A. FR4 PCB or higher CTI for transmitter boards, 175 CTI or higher for control
board
B. Tx and Rx Microcontrollers
C. Tactile Switches (Momentary)
D. Blue LED
E. PCB Loop Antenna (X2)
F. Battery: (3VDC CR2032)
–
G. Bypass Capacitors (100nF & 10nF)
H. Tactile Switches Input Diodes
I. Zener Diode (Voltage Regulation)
J. T r i a c
K. Cryst als
L. Slide Style Reverse Switch
Hunter Fan Company Confidential
14
Confidential
Page 20 of 20
PRODUCT SPECIFICATION
Casa Platform Remote Fan &
Light Control
Models: 65535, 65536, 65537
Rev. 3
18Jan12
Written by:
Shain Breland
XVI. Reference Documents
A. Hunter General Control Specification F4049
B. Hunter R&D-22 Electronic Fan Control NPD Procedure Rev 0
C. Hunter R&D-20 test procedure
D. Test Request Form F4086
E. Standard Audit Procedure, QA-FG
F. National Safe Transit Association Drop Test
G. ETL/UL/FCC/IC Certification Reports, to be completed by Hunter
H. Artwork, to be completed by Hunter Fan Company
I. UL and C-UL Std. 1917.
J. Hunter Fan Company PAP R&D-9
K. Hunter Fan Company Aesthetic Requirements document QA-AR
L. Hunter Fan Company QA R&D-5
M. EMC Performance, Latest IEC 61000 Standards
Hunter Fan Company Confidential
15

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 15
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : cafa8c19-fa95-11e1-0000-4865adfa1345
Producer                        : GPL Ghostscript 9.02
Keywords                        : ()
Modify Date                     : 2012:09:06 11:47:55-04:00
Create Date                     : 2012:09:06 11:47:55-04:00
Creator Tool                    : PDFCreator Version 1.2.2
Document ID                     : cafa8c19-fa95-11e1-0000-4865adfa1345
Format                          : application/pdf
Title                           : Casa Controls Platform Specification_Rev3
Creator                         : rbianco
Description                     : ()
Author                          : rbianco
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: IN2TX35

Navigation menu