Hunter Fan TX70 Remote Control Transmitter User Manual users manual
Hunter Fan Company Remote Control Transmitter users manual
users manual
Just Right Digital Thermostat Installation Mount Wallplate and Thermostat • What You Need Remove the wallplate from your thermostat by pressing the release tab on the bottom of the thermostat. See Figure 2. This thermostat includes two #8 slotted screws and two wall anchors for mounting. To install your thermostat, you should have the following tools and materials. • Slotted Screwdriver(s) • Small Philips screwdriver • Hammer • Electric drill and 3/16” bit • Two 1.5 V (AA) size alkaline batteries Owners Manual Model 42996 Congratulations! Your new Hunter thermostat will provide years of reliable service. Using this digital thermostat will provide more uniform comfort in your home through the seasons. Thank you for buying a Hunter product! Please read this manual for complete instructions on installing and operating your thermostat. If you require further assistance, call Hunter Technical Support at 1-888-830-1326 from 8am to 5pm Central Time. Remove the mylar label from the display window. Important Information 1. This thermostat is designed to work on the following systems: • • • • Gas - Standing Pilot Gas - Electronic Ignition Gas - Fired Boilers Gas - Milivolt Systems • • • • Oil - Fired Boilers Oil - Fired Furnace Electric Furnace Electric Air Conditioning Remove Old Thermostat CAUTION: Do not remove any wiring from existing thermostat before reading the instructions carefully. Wires must be labeled prior to removal. IMPORTANT! Turn off the power to the furnace at the main power panel or at the furnace. Remove existing thermostat cover and thermostat. See Figure 1. Some thermostats will have screws or other locking devices that must first be removed. Once the wall mounting plate is exposed, look for wires. If wires are not visible, they may be connected to the back of the wallplate. Again, look for screws, tabs, etc. Some models have doors that open to expose wires and mounting screws. See Figure 1. Typical Home Thermostats Figure 2 • • • Position wallplate on wall and pull existing wires through large opening. Then level for appearance. Mark holes for plastic anchors provided, if your existing holes do not line up with those on the wallplate. Drill holes with 3/16” bit and gently tap anchors into the holes until flush with wall. Reposition wallplate to wall, pulling wires through large opening. Insert mounting screws provided into wall anchor and tighten. See Figure 3. This thermostat will NOT control single-stage or multi-stage heat pumps or 110/220 V baseboard electric heating systems. 2. Temperature Range This thermostat can be set between 45°F and 95°F (7°C and 35°C). However, it will display room temperatures from 30°F to 99°F (0°C and 37°C). “HI” will be displayed if the temperature is higher than 99°F (37°C), and “LO” will be displayed if the temperature is lower than 30°F (0°C). This thermostat will automatically cutoff in Heat mode if the temperature rises above 95°F (35°C), and automatically cutoff in Cool mode if the temperature drops below 45°F (7°C). 3. Compressor Protection This thermostat provides a 3.5 minute delay after shutting off the cooling system before it can be restarted. This feature will prevent damage to your compressor caused by rapid cycling. It does not prevent a rapid compressor restart due to short power outages. 4. Battery Warning Two fresh AA alkaline batteries should provide well over one year of service. However, when the batteries become drained, the Low Battery Indicator will flash on the display. When this message occurs, install new alkaline batteries. You have approximately 1 minute to change the batteries and keep the thermostat’s settings. Once the batteries have become too low to ensure proper operation, your system will be turned Off, and the display will be cleared except for flashing Low Battery Indicator on the LCD display. CAUTION: When only the battery icon flashes on the display, the thermostat is shut down, and your system will no longer operate. In this condition, there is no temperature control of your dwelling. NOTE: If you plan to be away from the premises over 30 days, we recommend that you replace the old batteries with new alkaline batteries prior to leaving. 5. Notes This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Any changes or modifications to this equipment not expressly approved by Hunter Fan Company will void the user's authority to operate the equipment. Wire Labeling • • • • • • • Each wire coming from the wall to the existing thermostat is connected to a terminal point on that thermostat. Each of these terminal points is usually marked with a code letter as shown in Table A below. The number of wires in your system can be as few as two (for heat only systems), as many as eight, or any number in between. If you follow the labeling procedures correctly, you do not have to be concerned about how many wires there are. There is often no terminal marking on the existing thermostat of two wire, heat only systems. Just connect either of the wires to the Rh terminal, then connect the other wire to the W terminal to complete the circuit. IMPORTANT! BEFORE DISCONNECTING ANY WIRES, APPLY THE SELF-ADHESIVE LABELS PROVIDED TO THE WIRE AS SHOWN IN TABLE A BELOW. (For example, attach the label marked W to the wire that goes to the W or H terminal on your existing thermostat.) IGNORE THE COLOR OF THE WIRES since these do not always comply with the standard. After labeling wires, disconnect them from the existing thermostat terminals. Remove existing wallplate. To make sure wires do not fall back into wall opening, you may want to tape them to the wall. If hole in wall is larger than necessary for wires, seal this hole with insulating material so that no hot or cold air can enter the back of the thermostat from the wall. This air could cause a false thermostat reading. If the code letter on your existing thermostat is. . . then mark the wire with label shown. . . Figure 3 NOTE: 5-wire Systems If your thermostat has one wire marked R or Rh (2, 3, or 4-wire system), then leave the jumper wire between the Rh and Rc terminals on the wallplate. Otherwise, if you have separate Rh and Rc wires (5-wire system), then remove the jumper wire between the Rh and Rc terminals. Connect Wires and Mount Thermostat to Wallplate • and connect to thermostat terminal shown RH, R, VR or 4 24 Volt RC, VC 24 Volt Cool G or F Fan Y, C or M Air Conditioning Compressor Figure 4 Features Filter Change Indicator: Flashes when filter needs to be checked. Reset: Press with a paper clip to reset the thermostat and return to power-up settings. LCD Display: Shows Room Temperature, Set Temperature, and other feature information as required. Low Battery Indicator: Flashes when batteries need to be replaced. jdkkkl jnowk ioowk opop kol p jklklkl sdmkk m,dl ksk klw w Front Doors: Covers keys and batteries when not used for neat appearance. Open with one finger from top or bottom. • • • W or H Heating • jdkkkl jnowk ioowk opop kol p jklklkl sdmkk m,dl ksk klw w jdkjsolskj kslsosop skd jmdk klpklmx sksk kdssl djks djkop kdolls jdkjsolskj kslsosop skd jmdk klpklmx sksk kdssl djks djkop kdolls sjkwoiij9 dj jsow jk djik sdji848hjcn dj jdj djoe j sjkwoiij9 dj jsow jk djik sdji848hjcn dj jdj djoe j dskoks mdk mdk dskk jdks jp kdo dk djkk kdk o djkdjkk dskoks mdk mdk dskk jdks jp kdo dk djkk kdk o djkdjkk skd jmdm ksk kslls ks soirjn kel do dk djdm djdj do skd jmdm ksk kslls ks soirjn kel do dk djdm djdj do skmdl jdd jkdikfj jd jdiooe kdoeo jdjjk skdowlek kdkol kosd skmdl jdd jkdikfj jd jdiooe kdoeo jdjjk skdowlek kdkol kosd Match and connect the labeled wires to the appropriate coded terminal screws on the wallplate. (See Figure 4, 5.) Ignore any wires which may be present, but which were not connected to the old thermostat. Table A NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on this thermostat. Tape up the wire and do not use. This wire provides electricity to non-battery powered thermostats. • • Figure 5 Be sure to tighten the terminal screws securely, otherwise a loose wire could cause operational problems with your system or thermostat. Push excess wire back into the hole to prevent interference when installing the thermostat to the wallplate. Make sure the System Switch is set to OFF, and the Fan Switch is set to AUTO. Insert the tabs on top of the thermostat body into the slots at the top of the wallplate. Press the bottom of the thermostat body into the snap on the bottom of the wallplate. Refer to Figure 2. (NOTE: Do not force the thermostat onto the wallplate, as the terminal pins may be damaged. If it does not snap properly, the thermostat may not work.) Insert the two AA size alkaline batteries, observing the polarity marked inside the battery compartment. Switch on the main power at the panel or furnace. w sskdl ekk kdo dhjk jdk djik klk9i mkej kd dko cjkol kdoklk kdoo djk p ckoe o ckop fkpe kfodpp kcod oppp System Switch: Selector switch for Heat, Cool, and Off. Fan Switch: Fan switch for Automatic or Continuous fan operation. Filter Key: Resets the filter change counter to zero. Up and Down Keys: Keys for changing the Temperature setting. Also used for adjusting the Span. Battery Compartment: Front access allows easy insertion of two AA 1.5V batteries. Form No. 41970-01 Rev 6/5/2006 Selector Switches (See Figure 6) Use the switches on the back of the thermostat and in the remote control to match the thermostat to your system (either gas or electric), choose between temperature readout (either Fahrenheit or Celsius), and set the remote control address. • • • Heating System Selector (HG - HE switch) The factory position for this switch is in the “HG” position. Leave it in this position if you have a gas furnace or an oil burner. If you have an electric furnace, test to see whether the Heat and Fan come on as expected after installation. If the Fan operation is normal, leave it in the “HG” position. If the Fan does not come on within a minute of the thermostat calling for heat, change the switch position to “HE”. The system selector has no effect in the cooling mode. NOTE: “HG” position is for gas and most other systems. “HE” position is for certain electric systems having a fan relay. F° / C° selector (Fahrenheit / Celsius) Your thermostat is set for F° mode from the factory. In order to change to C° mode, slide the switch to C° and press the reset button on front of the thermostat with a paper clip. NOTE: Unless the reset button is pressed, the thermostat will not change temperature mode. Remote Control Address Use a pin to configure the four Remote Control Address switches. NOTE: Write down the address to which you configure these switches, as you will have to configure the Remote Control to the same address. Setting New Temperature • Press either the up or down key and hold for longer than 1 second. • The display will flash to show that you are in Set Temperature mode, then you can release the key. • Press either up or down again to change to your desired Set Temperature. Hold the key down for over 2 seconds to fast-advance the Set Temperature. Raises Setting Lowers Setting When the total system run time for heat and cool reaches 400 hours, the Filter Change Indicator will flash as a reminder to check your system’s filter. NOTE: Pressing the Filter key at any time for less than 3 seconds will cause the Filter Change Indicator to appear on the LCD. This is only to confirm key operation, and the counter is not affected unless the key is held for greater than 3 seconds. Figure 8 NOTE: You can not change your thermostat’s setting by more than two degrees in either direction by using the remote control. If you change the setting by two degrees, you must wait until the room temperature arrives at the new setting before you adjust the setting again with the remote control. Auto Cut Off DIP 1 2 3 4 A1 A2 A3 ON Remote Control Address (SW5) A0 You can use the remote control (12 volt battery not included) that came with your thermostat to adjust the temperature setting. Press the “+” side of the remote button to raise the setting one degree, and press it twice to raise the setting two degrees. The “+” side of the button will glow red each time you press it. Press the “–” side of the remote button to lower the setting one degree, and press it twice to lower the setting two degrees. The “–” side of the button will glow blue each time you press it. See Figure 8. Filter Monitor The thermostat counts the number of hours your system’s filter has been in use. To maximize your system’s performance and energy efficiency, change or clean your filter regularly. After changing or cleaning the system filter, press and hold the Filter key for 3 seconds. The display will blink, and the counter will be reset to zero. Temperature Display (SW4) Remote Operation Fan Option (SW3) SPAN Setting Your thermostat is set at the factory to cycle at 1°F (0.5°C) above and below the set temperature. (Span = 2) This setting has been designed to provide a comfortable room temperature under most all conditions. However, if you find your system cycling too fast or too slow, then the Span can be adjusted to modify the cycle time. Note that if your system has malfunctioned and no longer responds to thermostat controls, the Auto Cut-Off will have no effect. • Press and hold BOTH for three seconds. The display will flash, and SPAN will be displayed on the LCD. TROUBLESHOOTING • Press to raise the Span to 3. This setting INCREASES the cycle time by allowing your system to run LONGER. No Display. 1. Check battery connections and batteries. 2. Press RESET button with a small pin and hold in for two seconds. • Press to lower the Span to 1. This setting DECREASES the cycle time by causing your system to run SHORTER. Entire Display Dims. 1. Replace Batteries. Auto Fan Does Not Turn On Properly. 1. Move HG/HE selector to correct position. Heating or Cooling Does Not Go On or Off. 1. Check that the function switch is in the correct position (“HEAT” or “COOL”). 2. There may be as much as 4-minute delay before the system turns On—wait and check. (Compressor protection delay.) 3. Check your circuit breakers and switches to ensure there is power to the system. 4. Replace batteries. 5. Make sure your furnace blower door is closed properly. 6. If your system only uses 4-wires, be sure the jumper wire is installed between the Rc and Rh terminals. Figure 6 Remove the battery compartment Cover from the back of the remote control. See Figure 7. Use a pin to configure the four remote control Address switches to same address you gave to the thermostat. Your thermostat will automatically cutoff in Heat mode if the room temperature rises above 95°F (35°C). It will cutoff in Cool mode if the room temperature drops below 45°F (7°C). The Span settings remain the same for both HEAT and COOL, and can be changed in any System Switch position. When batteries are installed in the thermostat, or the Reset key is pressed, the Span is reset back to setting 2. Low Battery Warning Problem Your thermostat has a two-stage low battery warning system. When the batteries are first detected to be weak, the first stage low battery warning is indicated by battery symbol flashing on the LCD display. At your earliest convenience, you need to replace the batteries with 2 new AA alkaline batteries. Start-up When the batteries become too weak for normal operation, the thermostat enters the second stage low battery warning which shuts down the thermostat. In this condition, “BATT” flashes alone on the display, and the thermostat will turn your system Off. Your system will remain shut-off until the batteries are replaced. The LCD will show the factory default display of 70°F (21°C) when batteries are first installed, or after the Reset button is pressed. The temperature will update after a few seconds. NOTE: The thermostat will still keep the current Set Temperature and Filter run time in memory until new batteries are installed. After confirming that new batteries have been inserted, the thermostat will return to normal operation. System Selector Switch Error Mode Figure 7 Operation The System Selector switch on the front of the thermostat determines the operating mode of the thermostat. You may select COOL, OFF, HEAT. NOTE: Anytime you install or remove the thermostat from the wallplate, slide the System Selector to the OFF position to prevent the possibility of a rapid system On-Off. Fan Switch The Fan switch should normally be located in the AUTO position. The Fan will be turned on along with normal operation of your system. In a normal gas or oil furnace, the Fan will be turned on by your furnace after its warm-up delay. For electric heat and air conditioning operation, the Fan will turn on with the system. Thermostat does not respond to Remote Control 1. Replace the batteries in the remote control. 2. Ensure the Remote Control Address switches in the thermostat and the remote control are set to the same adress. If the thermostat is unable to control your system due to an unexpected battery problem, the thermostat will enter Error Mode. In this condition, the thermostat flashes “Er” on the LCD display, and shuts off your system. To correct this problem, replace the batteries with 2 new AA alkaline batteries, even if you have recently replaced them. Next, use a paper clip to press the RESET button next to the keypad. You will need to reprogram your thermostat and confirm normal operation. Ask Your Local Retailer for Other Quality Products from Hunter. If Error Mode returns, please call Technical Support at 1-888-830-1326 for further information. To run the Fan on continuously, slide the Fan switch to the ON position. Air Purifiers Ceiling Fans Humidifiers ®� Form No. 41970-01 Rev 6/5/2006 Hunter Fan Company 2500 FRISCO AVENUE MEMPHIS, TN 38114 © 2006, Hunter Fan Company
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : 3.1.1-111 Create Date : 2006:06:05 16:28:16-05:00 Modify Date : 2006:06:05 16:28:30-05:00 Metadata Date : 2006:06:05 16:28:30-05:00 Creator Tool : Adobe InDesign CS2 (4.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 12214 bytes, use -b option to extract) Document ID : adobe:docid:indd:44ba1adf-850c-11da-91ec-ba09ebc07c8d Version ID : 1 Instance ID : uuid:a660cf24-2831-49e2-a7fe-aa29e53a5359 Rendition Class : proof:pdf Format : application/pdf Producer : Adobe PDF Library 7.0 Trapped : False Page Count : 2 Creator : Adobe InDesign CS2 (4.0)EXIF Metadata provided by EXIF.tools