Hunter SSW Wireless Solar Sync Transmitter User Manual

Hunter Industries Inc Wireless Solar Sync Transmitter Users Manual

Users Manual

Wireless ET Sensor for Compatible Hunter ControllersWireless®Owner’s Manual and Programming Instructions for:•  WSS: Wireless Solar Sync kit Pro-C, PCC, ICC, and I-Core controllers•  WSSSEN: Wireless Solar Sync kit for ACC and X-Core controllers
TABLE OF CONTENTSINTRODUCTION................................................................................2SYSTEM OVERVIEW AND OPERATION ...........................................2SENSOR DETAILS ..............................................................................4Installing the Sensor ......................................................................4Clik Operation ...............................................................................5Bypassing the Sensor ....................................................................5Maintaining the Sensor..................................................................5CONNECTING TO THE CONTROLLER .............................................6Installing and Wiring the Module ..................................................6Pro-C Conventional Controller (PCC Series) .................................7Pro-C Controller (PC Series)  .........................................................9ICC Controller  ............................................................................10I-Core Controller .........................................................................11X-Core Controller ........................................................................12ACC Controller ............................................................................12ADDRESSING WIRELESS RECEIVER/SENSOR ...............................13PROGRAMMING CONTROLLER RUN TIMES .................................14PROGRAMMING THE SOLAR SYNC MODULE ..............................15CALIBRATION / SETUP PERIOD .....................................................18TROUBLESHOOTING GUIDE ..........................................................19SPECIFICATIONS / DIMENSIONS / FCC NOTICE...........................20Controller Compatibility ..............................................................20Specifications ..............................................................................20Dimensions ..................................................................................20FCC Notice ..................................................................................21Industry of Canada Notice ..........................................................22CE and Australia Notice ..............................................................22
2SYSTEM OVERVIEW AND OPERATIONThe Wireless Solar Sync System is simply and easily installed on any compatible Hunter Irrigation controller (see Owner’s Manual to verify compatibility). The Wireless Solar Sync Sensor measures solar radiation and temperature and calculates the daily evapotranspiration (ET) factor for irrigation. This represents the amount of water lost by the plants due to local climate conditions, which needs to be replaced by irrigation. The Wireless Solar Sync also includes Hunter Rain-Clik™ and Freeze-Clik® sensors that will automatically shut down the irrigation system during rain events or freezing conditions.Enter a mid summer watering program in your controller per the programming instructions in the Owner’s Manual provided with your controller. The Wireless Solar Sync Sensor sends weather data and applies it daily to the controller’s water schedule by adjusting the controller through the seasonal adjust feature.This Owner’s Manual applies to the following kits:•   WSS: Wireless Solar Sync kit for Hunter Pro-C, PCC, ICC, and I-Core controllers   •   WSSSEN*: Wireless Solar Sync kit for Hunter ACC and X-Core controllers * Note that WSSSEN does not include the Solar Sync Module. The ACC and X-Core controllers have the Solar Sync software built in and do not require the Solar Sync Module. Therefore, the WSSSEN should be used with the ACC and X-Core Controllers.The Solar Sync is a sensor system that, when connected to a compatible Hunter controller, will automatically adjust your controller watering based upon changes in local climate conditions. The Solar Sync utilizes a solar and temperature sensor to measure on-site weather conditions used to determine evapotranspiration (ET), or the rate at which plants and turf use water. In addition, Solar Sync includes a Hunter Rain-Clik™ and Freeze-Clik™ sensor that will shut down your irrigation system when it rains and/or during freezing conditions. INTRODUCTIONA small module connects the sensor to the controller and will automatically increase or decrease watering run times based on changes in weather. The result is a new water-efficient irrigation product that promotes water conservation and healthier plants.  You simply program your controller like you normally would, and  the Solar Sync takes over from there, eliminating the need to manually adjust your watering schedule.
3SYSTEM OVERVIEW AND OPERATION®Solar Sync ModuleWall Mount BracketWireless Solar Sync Receiver Wireless Solar Sync Sensor
4SENSOR DETAILSInstalling the SensorUsing the screws provided, mount the Solar Sync sensor on any surface where it will be exposed to unobstructed sun and rainfall, but not in the path of sprinkler spray. The sensor needs to be oriented upright and the swivel bracket can be moved for mounting on angled surfaces. Loosen the locknut and screw before swiveling the bracket and then retighten. Note: The Wireless Solar Sync Sensor is designed to operate to a maximum distance of 800 feet  (228 m) from the Wireless Receiver.  Note: Place Solar Sync where it can receive full sun.The Sensor Gutter Mount can also be used as an optional mounting method. The Sensor Gutter Mount (SGM) allows the Sensor to be mounted directly to the edge of a gutter. Install the SGM on the Sensor by removing the extension arm supplied with your Sensor and reinstalling SGM in its place. Position the SGM on the edge of the gutter and secure by twisting the thumb screw.Re-use screw and nut from original extension armSunSolar Sync
5SENSOR DETAILSClik OperationThe Rain-Clik™ will keep the irrigation from starting or continuing during rainfall. No adjustment or calibration is required for the Rain-Clik™ sensor. The Rain-Clik™ uses patented Quick Response™ technology that will shut the system off during the first few minutes of rain. The only adjustment that is necessary is the vent ring that will either slow down or speed up the time at which the sensor dries out and the system is turned back on. Opening the vent will speed up the dry out time and closing the vents will slow down dry out time.In addition, the Solar Sync’s built-in temperature sensor provides system shutdown when freezing conditions occur. At approximately 37˚ F/3˚ C and below the Solar Sync module will command the controller to shut down. A “sensor off” indication will be displayed on your controller when the sensor is active. When temperatures rise above 37˚ F/3˚ C, automatic irrigation will be activated at the next scheduled start time.  Bypassing the SensorIf the Rain Sensor or Freeze Sensor is preventing system operation, SENSOR OFF will be displayed on the controller’s display. Simply move the Bypass switch on the controller to BYPASS and the Solar Sync’s Rain and Freeze Sensor will be bypassed. This allows you to operate your system. The Solar Sync will continue to make adjustments to your controller’s watering schedule.The controller’s Rain Sensor switch should be in the ACTIVE position for the Rain Sensor and Freeze Sensor to interrupt watering during rainy and/or freezing conditions. Maintaining the SensorThe Solar Sync sensor is designed for outdoor use, but must be kept clean to function correctly. Wiping the clear dome covering the solar radiation sensor every 6 months is recommended. Do not use harsh chemicals or abrasives on the clear dome.DomeVent RingVents
6CONNECTING TO THE CONTROLLERInstalling and Wiring the ModuleBegin by activating the CR2032 backup battery (used for date/time backup in the event of a power outage) by pulling the battery insulator at the bottom of the module. The expected battery life is ten years. If the battery requires replacement, the battery compartment is located on the back of the Solar Sync module. Remove the cover and install the battery with the positive side (+) of the battery visible, facing toward you. Replace the battery cover. Replace battery with CR2032 type battery only. Use of another battery may present a risk of fire or explosion.Note: Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire.The Solar Sync module is designed to be wall-mounted next to the irrigation controller. A rubber cover is provided for outdoor installations to protect the module from the weather. Use two anchors or self-tapping screws to secure the module to the wall. Place the rubber cover mounting tab behind the module before screwing the module to the wall.Note: If you are installing Solar Sync on an ACC or X-Core Controller, the Solar Sync Module is not required. For the ACC or X-Core controllers, the WSSSEN kit should be used, as it does not include the Module. (See the  controller‘s owner‘s manual for more details.)
7CONNECTING TO THE CONTROLLERPro-C Conventional Controller (PCC Series)The PCC series version of the Pro-C is designed so that the Solar Sync module can be installed inside the controller cabinet.  Use the two screws provided to mount the module as shown in the diagram. 1.   Connect the red wire from the Solar Sync module to the AC1 terminal2.   Connect the white wire from the Solar Sync module to the AC2 terminal 3.   Connect the blue wire from the Solar Sync module to the REM terminal4.  Remove the flat metal jumper from the two SEN terminals5.  Connect the yellow wire to one of the SEN terminals6.   Connect the orange wire to the other SEN terminalNote: For Pro-C PCC Series controllers, there are provisions inside the controller to mount the Solar Sync module.Pro-C PCC Controller Solar Sync Module®PCC SERIESSEN: ORANGESEN: YELLOWREM: BLUEController ConnectionsAC2: WHITEAC1: RED
8Pro-C Conventional Controller (PCC Series)Mount the Wireless Receiver on the controller cabinet using an available knock out and secure with the supplied conduit nut. Or, use the supplied brackets to mount the Wireless Receiver on the wall. Depending on the installation, the supplied 1.5" (3.8 cm) extender may be required (shown below). Route the wires from the Wireless Receiver into the controller cabinet.1.  Make sure power to the controller is turned off2.   Connect the black Receiver wire to the black Module wire3.   Connect the green Receiver wire to the green Module wire 4.  Initialize communication by following steps outlined in “Addressing Wireless Receiver/Sensor” section on page 13CONNECTING TO THE CONTROLLER®PCC SERIESSEN: ORANGESEN: YELLOWREM: BLUEController ConnectionsAC2: WHITEAC1: RED1.5" extender (optional use)GreenBlackWireless Receiver Mounted to ControllerWall Mount Option
9CONNECTING TO THE CONTROLLER®Pro-C Controller (PC Series) For the PC series Pro-C Modular controller, mount the Solar Sync module on the wall next to the controller cabinet. There is an additional knockout on the right side of the controller cabinet to route Solar Sync wires into and out of the cabinet.1.   Connect the red wire from the Solar Sync module to the AC1 terminal2.   Connect the white wire from the Solar Sync module to the AC2 terminal3.   Connect the blue wire from the Solar Sync module to the REM terminal4.  Remove the flat metal jumper from the two SEN terminals5.  Connect the yellow wire to one of the SEN terminals6.   Connect the orange wire to the other SEN terminalMount the Wireless Receiver on the controller cabinet using the options described on page 8. Due to the position of the power module in the Pro-C controller, a more convenient option may be to mount the Wireless Receiver to the wall using the Wall Mount Bracket.1.  Make sure power to the controller is turned off2.   Connect the black Receiver wire to the black Module wire3.   Connect the green Receiver wire to the green Module wire 4.  Initialize communication by following steps outlined in “Addressing Wireless Receiver/Sensor” section on page 13
10CONNECTING TO THE CONTROLLERICC Controller 1.   Connect the red wire from the Solar Sync module to the AC1 terminal2.   Connect the white wire from the Solar Sync module to the AC2 terminal3.   Connect the blue wire from the Solar Sync module to the REM terminal4.  Remove the flat metal jumper from the two SEN terminals 5.  Connect the yellow wire to one of the SEN terminals6.   Connect the orange wire to the other SEN terminalMount the Wireless Receiver on the controller cabinet using an available knock out and secure with the supplied conduit nut, similar to the Pro-C installation shown on page 8. Or, use the supplied brackets to mount the Wireless Receiver on the wall. Depending on the installation, the supplied 1.5" (3.8 cm) extender may be required. Route the wires from the Wireless Receiver in to the controller cabinet.1.  Make sure power to the controller is turned off2.   Connect the black Receiver wire to the black Module wire3.   Connect the green Receiver wire to the green Module wire 4.  Initialize communication by following steps outlined in “Addressing Wireless Receiver/Sensor” section on page 13BlueOrangeYellowWhiteRed®
11CONNECTING TO THE CONTROLLERS1 S1 S2 S2 C CGND AC1 AC2 REM CP/MVRedWhiteBlueYellowOrangeSOLAR SYNC ModuleI-Core Controller 1.   Connect the red wire from the Solar Sync module to the AC1 terminal2.   Connect the white wire from the Solar Sync module to the AC2 terminal 3.   Connect the blue wire from the Solar Sync module to the REM terminal4.  Remove the flat metal jumper from the two SEN terminals5.  Connect the yellow wire to one of the SEN terminals6.   Connect the orange wire to the other SEN terminalMount the Wireless Receiver on the controller cabinet using an available knock out and secure with the supplied conduit nut. Or, use the supplied brackets to mount the Wireless Receiver on the wall. Depending on the installation, the supplied 1.5" (3.8 cm) extender may be required. Route the wires from the Wireless Receiver in to the controller cabinet.1.  Make sure power to the controller is turned off2.   Connect the black Receiver wire to the black Module wire3.   Connect the green Receiver wire to the green Module wire 4.  Initialize communication by following steps outlined in “Addressing Wireless Receiver/Sensor” section on page 13Solar Sync Module
12CONNECTING TO THE CONTROLLERX-Core ControllerThe X-Core Controller is programmed with Solar Sync technology and, therefore, does not require the use of the Solar Sync module. Simply mount the Wireless Receiver on the controller cabinet using an available knock out and secure with the supplied conduit nut. Or, use the supplied brackets to mount the Wireless Receiver on the wall, similar to the Pro-C installation shown on page 8. Depending on the installation, the supplied 1.5" (3.8 cm) extender may be required. Route the wires from the Wireless Receiver in to the controller cabinet.1.  Make sure power to the controller is turned off2.    Connect the black Receiver wire to the “SEN” Terminal location (it does not matter which “SEN” terminal is used)3.   Connect the green Receiver wire to the other “SEN” terminal location See X-Core owner’s manual for further details.*ACC ControllerThe ACC Controller is programmed with Solar Sync technology and, therefore, does not require the use of the Solar Sync module. Simply mount the Wireless Receiver on the controller cabinet using an available knock out and secure with the supplied conduit nut. Or, use the supplied brackets to mount the Wireless Receiver on the wall, similar to the Pro-C installation shown on page 8. Depending on the installation, the supplied 1.5" (3.8 cm) extender may be required. Route the wires from the Wireless Receiver in to the controller cabinet.1.  Make sure power to the controller is turned off2.   Connect the black Receiver wire to the black “ET” terminal on the master module3.   Connect the green Receiver wire to the green “ET” terminal on the master module See ACC owner’s manual for further details.*Note: *The X-Core and ACC controllers have the Solar Sync software built in. Please see the controllers’ owner’s manuals for Solar Sync programming instructions.
13ADDRESSING WIRELESS RECEIVER/SENSORThe Wireless Solar Sync Receiver and Sensor are already paired with the same frequency for an easy installation. When installed, the wireless Receiver will automatically go into a “search” mode looking for the signal from its paired Sensor. However, it is a good idea to initialize communication manually between the wireless Receiver and Sensor during installation to verify correct signal transmission.To initialize communication manually between wireless Receiver and Sensor:•   After Receiver’s green and black wires have been connected (see “Connecting To The Controller” section), restore power  to the controller•   The red LED in the center of the wireless Receiver will turn on and stay solid for 10 seconds, indicating that it is in search mode, searching for a signal from a wireless sensor•   While the red LED is solid and the wireless Receiver is in search mode, press and hold the spindle on the wireless Sensor. The LED on the wireless Receiver will blink 4 times and then turn  off, indicating that the signal from the wireless Sensor has  been acknowledged. To Validate Receiver/Sensor Communication or Re-address:•  Press and hold the spindle on the wireless Sensor•   The LED on the wireless Receiver will blink 2 times, confirming that the Receiver is addressed to the Sensor properlyNote: In the event of a power outage (or any other reason when the Receiver loses radio contact with  the wireless Sensor) the Receiver will automatically  go into search mode to re-establish communication with the Sensor once power is restored. However, when power is restored the controller will automati-cally go into rain shut off mode until communication with the Sensor is re-established, which may be up  to 60 minutes (maximum). Performing the steps listed above to validate Receiver/Sensor communication will remove the controller from rain shut off mode and will return to its programmed irrigation schedule. LEDspindle
14PROGRAMMING CONTROLLER RUN TIMESProgram your Hunter controller as specified in the Owner’s Manual. When setting station run times, enter the time that would normally be programmed during the peak summer watering season. The Solar Sync is designed to adjust all run times daily based upon on-site weather conditions. This is done through the seasonal adjustment feature on your controller. It is recommended that all programming be conducted with the controller Seasonal Adjustment set at 100%.Note: Set station run times for peak summer watering with seasonal adjustment set at 100%.
15PROGRAMMING THE SOLAR SYNC MODULEThe Solar Sync is simple to program. Only a few initial steps are necessary to program the module. When power is initially turned on, the display will show the time of day. Pressing the  button will sequence through the programming functions on the module. An arrow along the bottom of the display will indicate the function being programmed. If using the Solar Sync with the ACC or X-Core Controllers, consult the controller owner’s manual for programming details. (ACC and X-Core controllers do not use the Solar Sync module.)®®®Current Time   Press the  button press until the arrow is displayed over the  icon. The time of day will be flashing. Use the   or   button to set the current time. The arrow to the right of the display indicates AM or PM.Note: 24 hour mode will only be enabled with a 50 Hz power input.Controller Type   Press the  button until the arrow is displayed over the icon. Use the   or   button to select the correct Hunter controller. Region  For accurate measurements, the Solar Sync module needs to be programmed for the typical ET  (average July ET) for your region. Use the table on the next page to determine your region. Press the   button until the arrow is displayed over the icon. Use the   or   button to select your region (regions 1 through 4).
16PROGRAMMING THE SOLAR SYNC MODULEThe table will assist you in identifying the type of region you live in. There are four basic ET regions, each with descriptions of the region, along with typical ET and temperature characteristics. It is recommended that, if possible, the region be chosen based upon average July ET or peak summer ET (inches/mm per day).Use the following table for choosing your region (reference below). You can use A, B or C to help you choose which region is best for your area:A: Based upon the ET of your region using the average July ET or peak summer ET (inches/mm per day). This is the preferred option when selecting your regionB: Based upon the temperature for your region using the average July or the driest month high temperature (not the highest temperature for July)C: Based upon the general description of your region• U.S. Northern States  • Coastal RegionsIf the average July ET is< 0.17" (4.3 mm) per dayIf the average temperature for July is65°– 75° (18°C – 24°C)If the average temperature for July is75° – 85° (24°C – 29°C)• Mountains• U.S. Northern Inland StatesIf the average July ET is 0.18" – 0.23" (4.6 mm – 5.8 mm) per day• U.S. Southern States• Inland/High DesertIf the average July ET is 0.24" – 0.29" (6.1 mm – 7.4 mm) per dayIf the average temperature for July is85° – 95° (29°C – 35°C)• DesertsIf the average July ET is > 0.30" (7.6 mm) per dayIf the average temperature for July is95° – 105° (35°C – 41°C)* For Southern hemisphere locations, use the month of January.Region1Region2Region3Region4IF ANY OF THE CHOICES IN THE ROWS APPLY TO YOUR SITUATION, THEN THAT IS YOUR REGION SETTING CHOICE.A B C
17PROGRAMMING THE SOLAR SYNC MODULE®®Watering Adjustment  If you find that your landscape is “wetter” or “drier” than it should be, a watering adjustment function is provided to adjust watering equally to all stations. Use the  button on the module until the arrow is displayed over the icon. Use the   or   button to increase or decrease the amount of watering scaled 1 to 10 (1 for less water and 10 for more water). Hunter recommends observing performance carefully over the first weeks of operation before adjusting the watering.Note: If an individual zone is “wetter” or “drier” than the rest of the system, simply increase or decrease the amount of run time on the controller.No Water WindowIf required, the Solar Sync offers a no water window capability that prevents any irrigation from occurring during a specific period of the day. The No Water Window is a hidden feature. Press and hold the  button on the module for 5 seconds to program the No Water Window. An  will be flashing at Start along the right side of the display. Use the   or   button to adjust the time you would like the no watering period to start. Pressing the  button again will display an arrow flashing at End. Use the   or  button to adjust the time you would like the no watering period to end.
18CALIBRATION / SETUP PERIODAfter Solar Sync has been installed and programmed, it is recommended to allow the system to run for a few days at the initial setting. Because of the variety in site conditions (including sensor location, amount of direct sunlight available to the sensor, reflective heat from surrounding structures, etc), the initial setting may require adjustment in order to arrive at the desired performance. The calibration of the Solar Sync to a particular site can easily be accomplished by adjusting the Region and/or Water Adjustment settings. The instructions below outline this process:1.  Install Solar Sync sensor and program the module (as described in pages 10–12)2.  Allow system to operate at initial settings for a minimum of 3 days3.   Observe the Seasonal Adjust on the controller. If the Seasonal Adjust amount appears to be lower or higher than expected for that time of year, the Solar Sync settings need to be adjusted.     a.   Seasonal Adjust too low: Make sure controller dial is in the “Run” position. Increase the value on the Water Adjustment scale (10 is max). Once the setting is changed, the controller will immediately be updated with the new Seasonal Adjust %. Increase the Water  Adjustment setting until the desired Seasonal Adjust % is shown. If you max out the Water Adjustment scale at 10 and still require more Seasonal Adjust, move down to the next lower Region (from Region 4 to 3, for example).    b.  Seasonal Adjust too high: Make sure controller dial is in the “Run” position. Decrease the value on the Water Adjustment scale (default setting is 5). Once the setting is changed, the controller will immediately be updated with the new Seasonal Adjust %. Decrease the Water Adjustment setting until the desired Seasonal Adjust % is shown. If you minimize the Water Adjustment scale down to 1 and still require a reduction in Seasonal Adjust, move up the next Region (from Region 2 to 3, for example).Station Run Times: It is important to understand that Solar Sync provides a global seasonal adjustment to the controller. This means that all station run times will be modified by the seasonal adjust percentage shown. When programming the controller, the run times should be entered that represent peak season watering schedules. If the Solar Sync is adjusting to the appropriate seasonal adjust value but the run time for a particular station appears to be too long/short, adjust the station run time in the controller program. When adjusting station run times, make sure the seasonal adjust valve is set to 100%.
19TROUBLESHOOTING GUIDEProblem Causes SolutionsController shows “ERR” in display • Module wires not properly connected to controller terminalCheck the connection between module and controller and compare to wiring diagram in System Installation section of Owner’s ManualSolar Sync module shows “ERR” • Connection between module and sensor faultyCheck connection between module and sensor (green and black wires)Seasonal Adjust seems low • Region too high• Water Adjustment Setting too low• Location of Sensor does not allow for full sunMake sure controller dial is in “RUN” position. Increase the value on the Water Adjustment scale (the default setting is 5). If you max out  the Water Adjustment scale at 10 and still require more seasonal  adjustment, move down one Region (from 4 to 3, for example) and start at Water Adjustment setting 5. Solar Sync will immediately update the Seasonal Adjust on the controller. If it is still too low, repeat the adjust-ment until the desired seasonal adjust is showing on the controller. Seasonal Adjust seems high • Region too low• Water Adjustment setting too highMake sure controller dial is in “RUN” position. Decrease value of the Water Adjustment setting. If you minimize the Water Adjustment scale at 1 and still require a reduced seasonal adjustment, move down up one Region (from 2 to 3, for example) and start at Water Adjustment setting 5. Solar Sync will immediately update the Seasonal Adjust on the controller. If it is still too high, repeat the adjustment until the desired seasonal adjust is showing on the controller. Rain or Freeze shutoff not activating • Rain Sensor Bypass Switch on Controller set to “Bypass”• Jumper Clip still on controller wiring terminalSet the Controller Bypass Switch in the “Active” position.Remove jumper clip.Run times for a particular station are too short/too long• Program Run Time too long/too shortSolar Sync provides a global seasonal adjustment to the controller.  If a particular station has run times too long or too short, make the  appropriate adjustment to the program in the controller. Solar Sync still sending Seasonal  Adjust when Controller Bypass switch in the “Bypass” position• Solar Sync’s automated seasonal adjustment cannot be de-activated by the Bypass switch • The Bypass switch only controls the Rain/Freeze shutoff function of the Solar SyncHunter Technical Service: 1-800-733-2823 or www.hunterindustries.com/Support/Ask_Expert/default.htm
20SPECIFICATIONS / DIMENSIONS / FCC NOTICEController CompatibilityThe Solar Sync is designed for use with Hunter controllers that are enabled with a Smart Port connection. WSS: Wireless Solar Sync kit, for use with Hunter Pro-C, PCC, ICC, and I-Core ControllersWSSSEN: Wireless Solar Sync kit (no module included), for use with Hunter ACC and X-Core controllers Specifications•   Power Input: 24 VAC 50/60 HZ (from controller)•   Current draw: 25 mA at 24 VAC•   Non Volatile Memory•   Replaceable 10 year lithium battery: CR2032 (in module)•   10 year battery (wireless)•   Maximum distance module from controller: 6 ft (2 m)•   Maximum distance Receiver to Module: 6 ft (2 m)•   Maximum distance Sensor to Receiver: 800 ft (228 m)•     Wiring: 18 AWG/1 mm or 20 AWG/0.8 mm diameter  minimum from Sensor to Module•   UL Listed•   Direct Burial and UV approvedDimensionsSensor:  3" H x 9" W x 1" D (7.6 cm x 22.9 cm x 2.5 cm)Module:  13⁄4" H x 5" W x 5⁄8" D(4.4 cm x 12.7 cm x 0.6 cm) Receiver:  5.5"H x 1.5" W x 11⁄2" D(14 cm x 3.8 cm x 3.8 cm)Receiver with Wall Mount Bracket: 61⁄8" H x 2¾" W x 31⁄2" D(15.5 cm x 7 cm x 8.9 cm)
21SPECIFICATIONS / DIMENSIONS / FCC NOTICEFCC NoticeTransmitter FCC ID : M 3USSWThis device complies with FCC rules Part 15. Operation is subject to the following two conditions:1.  This device may not cause harmful interference and2.  This device must accept any interference that may be received, including interference that may cause undesired operationThis equipment has been tested and found to comply with the limits for class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the radio equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna•  Increase the separation between the equipment and receiver•  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected•  Consult the dealer or an experienced radio/TV technician for helpThe user is cautioned that changes and modifications made to the equipment without the approval of the manufacturer could void the user’s authority to operate this equipment.Signature:Place: San Marcos, CA Full Name: Peter WoytowitzDate: March 22, 2010 Position: Engineering ManagerTrade Name Wireless Solar SyncModel Number WSSRCompliance Test Report NumberB00217D4Compliance Test Report Date 1/29/2010Responsible Party Hunter Industries IncorporatedAddress 1940 Diamond St, San Marcos, CA 92078Telephone 760-744-5240I, the undersigned, hereby declare that the equipment specified above conforms to the above requirements.
22SPECIFICATIONS / DIMENSIONS / FCC NOTICEIndustry of Canada NoticeSensor - IC: 2772A-SSWReceiver - IC: 2772A-SSWROperation is subject to the following conditions:•  This device may not cause harmful interference and•  This device must accept any interference received, including interference that may cause undesired operationThis class B digital apparatus complies with Canadian ICES-003.The term IC before the certification/registration number only signifies that the Industry of Canada technical specifications were met. Operation is subject to the following conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation in the device. CE and Australia NoticeHunter Industries hereby declares that this remote control device is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/CE.Declaration of Conformity: We, Hunter Industries Incorporated, 1940 Diamond Street, San Marcos, CA 92078, declare under our own responsibility that the Wireless Solar Sync, model numbers WSSTR and WSSR, to which this declaration refers, conforms with the relevant standards:Emissions:      ETSI EN 300 220-1 V2.1.1  Immunity:  ETSI EN 301 489-1 V1.4.1     ETSI EN 300 220-2 V2.1.1    (per IEC61000-4-2 through IEC61000-4-6, and IEC61000-4-11)  ETSI EN 301 489-1 (per EN55022)  EN 61000-3-2  EN 61000-3-3 Signature:Place: San Marcos, CA Full Name: Peter WoytowitzDate: March 22, 2010 Position: Engineering Manager
23NOTES
24NOTES
25NOTES
Hunter Industries Incorporated • The Irrigation Innovators © 2010 Hunter Industries Incorporated1940 Diamond Street • San Marcos, California 92078 USA  LIT-520     3/10www.hunterindustries.com