Hytera Communications RD98XSIU1 Digital Repeater User Manual RD98XS Owner s Manual 100202
Hytera Communications Corporation Limited Digital Repeater RD98XS Owner s Manual 100202
User manual
Preface Thank you for purchasing Hytera RD98XS series DMR digital repeater. As a product built to the DMR standard, RD98XS is endowed with ergonomic design, reliable performance and comprehensive digital functions to deliver an advanced communication solution. With RD98XS, you can make use of digital advantages to top the competition! To ensure you get maximum benefit from the product, please read this manual carefully before use. Copyright Information Hytera is the trademark or registered trademark of Hytera Communications Corporation Limited (the Company) in the People's Republic of China (PRC) and/or other countries or areas. The Company retains the ownership of its trademarks and product names. All other trademarks and/or product names that may be used in this manual are properties of their respective owners. The product described in this manual may include the Company's computer programs stored in memory or other media. Laws in PRC and/or other countries or areas protect the exclusive rights of the Company with respect to its computer programs. The purchase of this product shall not be deemed to grant, either directly or by implication, any rights to the purchaser regarding the Company's computer programs. The Company's computer programs may not be copied, modified, distributed, decompiled, or reverse-engineered in any manner without the prior written consent of the Company. Disclaimer The Company endeavors to achieve the accuracy and completeness of this manual, but no warranty of accuracy or reliability is given. All the specifications and designs are subject to change without notice due to continuous technological development. No part of this manual may be copied, modified, translated, or distributed in any manner without the prior written consent of the Company. We do not guarantee, for any particular purpose, the accuracy, validity, timeliness, legitimacy or completeness of the third-party products and contents involved in this manual. If you have any suggestions or would like to receive more information, please visit our website at: http://www.hytera.com. FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Verification of harmful interference by this equipment to radio or television reception can be determined by turning it off and then on. The user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a different circuit to that of the receiver's outlet. Consult the dealer or an experienced radio/TV technician for help. Operation is subject to the following two conditions: This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. Note: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Compliance with RF Exposure Standards Hytera's radio complies with the following RF energy exposure standards and guidelines: United States Federal Communications Commission, Code of Federal Regulations; 47 CFR § 1.1307, 1.1310 and 2.1091. American National Standards Institute (ANSI) / Institute of Electrical and Electronic Engineers (IEEE) C95. 1:2005; Canada RSS102 Issue 5 March 2015 Institute of Electrical and Electronic Engineers (IEEE) C95.1:2005 Edition Operational Instructions and Training Guidelines To ensure optimal performance and compliance with the occupational/controlled environment RF energy exposure limits in the above standards and guidelines, users should always adhere to the followings: Gain of antenna must not exceed 5.5dBi. Antenna Installation: install the antenna at least 80cm away from your body, in accordance with the requirements of the antenna manufacturer/supplier. Checking Items in the Package Please unpack carefully and check that all items listed below are received. If any item is missing or damaged, please contact your dealer. Duplexer Installation Kit Power Cord Repeater Repeater Overview Front Panel No. Part Name No. ○ Accessory Jack ○ Part Name Volume Control Knob / Power Indicator ○ Repeater Mode Indicator ○ Analog Mode Indicator ○ Slot 2 RX Indicator ○ Slot 2 TX Indicator ○ Digital Mode Indicator ○ Slot 1 TX Indicator ○ Slot 1 RX Indicator 10 ○ Alarm Indicator 11 ○ Programmable Keys * 12 ○ LCD Display 13 ○ Channel Up Key * 14 ○ Menu Navigation Knob 15 ○ Channel Down Key * 16 ○ Speaker Rear Panel No. Part Name No. Part Name ○ TX Antenna Connector ○ Optional Connector 1 ○ RX/Duplex Antenna Connector ○ Optional Connector 2 ○ Monitor/Test Jack ○ Accessory Jack ○ DC Power Inlet ○ Ethernet Port * ○ Ground Screw Internal Parts No. Part Name No. Part Name ○ Baseband Module ○ Front Panel ○ RF PA Module ○ Excitor Module ○ RX Module Installation Proper installation can ensure optimum performance and reliability of the repeater. Be sure to read the following installation requirements and instructions carefully, before you install the repeater. Installation Overview The information below is an overview for installing the repeater and auxiliary equipment. Unpack and inspect the equipment. Perform a pre-installation function check test of the equipment, and configure parameters. Pay particular attention to environmental conditions at the site, ventilation requirements, and grounding and lightning protection. Install the equipment at the site. Make necessary electrical and cabling connections, including the following: - DC power cord - Coaxial cables to TX and RX antennas (if you use two antennas) Perform a post-installation function check test of the equipment, to verify proper installation. Before Installation Before you install the repeater at the site, you are suggested to power on the repeater and check it for proper operation. 1. Applying Power Before applying power to the repeater, make sure the voltage of DC power supply or battery is compliant with the operating voltage range of the repeater. Then connect the DC power supply or battery to supply power to the repeater. 2. Verifying Proper Operation Operation of the repeater can be indicated by the 8 LEDs located on the front panel. After proper operation is verified, you can configure parameters for the repeater. Caution: Some repeater components can become extremely hot during operation. Turn off all power and wait until the repeater is sufficiently cool before touching the repeater. 3. Configuring Parameters You may customize repeater parameters such as TX/RX frequency, TX power and signalling, according to user needs. After configuration of parameters is complete, you may perform site installation. Installation Requirements 1. Environmental Conditions at Intended Installation Site The repeater may be installed in any location suitable for electronic communication equipment, provided that the environmental conditions do not exceed the equipment specifications for temperature, humidity and air quality. Operating Temperature This is the temperature measured in close proximity to the repeater. For example, if the repeater is mounted in a cabinet, the temperature within the cabinet is measured. Humidity Humidity conditions should not exceed 95% relative humidity @ 50°C. Air Quality For equipment operating in an area which is environmentally controlled and with the repeater rack mounted, the airborne particle level must not exceed 25μg/m3. And for equipment operating in an area which is not environmentally controlled and with the repeater cabinet mounted, the airborne particle level must not exceed 90μg/m3. Caution: If the repeater is to be installed in an area which is usually dusty, dirty, or does not meet the air quality requirements, then the air used to cool the repeater modules must be treated using appropriate filtering devices. Dust or dirt accumulated on the internal circuit boards and modules is not easily removed, and can cause malfunctions such as overheating and intermittent electrical connections. 2. Equipment Ventilation The PA heatsink is equipped with a cooling fan used to provide forced convection cooling. When planning the installation, observe the following ventilation guidelines: Customer supplied cabinets must be equipped with ventilation slots or openings for air to enter and exit. If several repeaters are installed in a single cabinet, ensure ventilation openings surrounding each repeater allow for adequate cooling. All cabinets must have at least 10cm of open space between the air vents and any wall or other objects. When multiple cabinets (each equipped with several repeaters) are installed in an enclosed area, ensure appropriate ventilation and consider air conditioning or other climate control equipment, to satisfy the temperature requirements stated above. 3. Equipment Installation Methods The RD98XSi repeater may be mounted in a rack, bracket or cabinet, and may be placed on your desk. 4. Site Grounding and Lightning Protection Caution: Proper site grounding and lightning protection are vitally important considerations. Failure to provide proper lightning protection may result in permanent damage to the repeater. The ground and lightning protection system is one of the most important considerations when designing a communication site. Proper grounding techniques and lightning protection are closely related, and the general category of site grounding may be divided into the following two sections: Electrical Ground Ground wires carrying electrical current from circuitry or equipment at the site are included in the category of electrical ground. Examples include the AC and DC power used to source equipment located at the site, and wires or cables connected to alarms or sensors located at the site. Lightning Ground Providing adequate lightning protection is critical to a safe reliable communication site. The repeater is equipped with a ground screw located on the rear panel. This screw is used to connect the repeater to the site grounding. All antenna cables, and AC and DC power cords, should be properly grounded and lightning protected by following the rules and guidelines provided in the above sections. Installation Steps You will need a Philips screwdriver (cross head screwdriver), a Torx (T10) screwdriver and a spanner, to install the repeater. Caution: Be sure to observe proper electrostatic discharge precautions if any part must be removed from the repeater. The installation steps are as follows: 1. Mount the repeater in a rack, bracket or cabinet. 2. Connect accessories such as antenna cables and power cords to the repeater. If a duplexer needs to be mounted If the repeater needs to work with a duplexer, your will need to implement the following installation steps prior to the above steps 1 and 2. 1. Loosen the three screws on the bracket with a Philips screwdriver. 2. Install the optional duplexer and the bracket. Be sure to observe the specifications of the two antenna connectors on the duplexer, to determine which connector should be connected to the transmitter. Ensure the antenna connector connected to the transmitter is beside the rear panel of the repeater. Take Hytera supplied duplexer as an example. If the transmitter is connected to the low cavity connector, the duplexer should be mounted with the front side facing upwards (see the following figure on the left); and if it is connected to the high cavity connector, the duplexer should be mounted with the front side facing downwards (see the following figure on the right). 10 3. Loosen the screw at the back of the top cover, and then pull the top cover to remove it. 4. Loosen the 6 screws locking the PA heatsink, remove all power, data and RF cables from the PA, and finally remove the PA heatsink. 5. Mount the duplexer, and fasten the 2 screws inside the housing and on the side panel respectively. Then mount the PA heatsink, and connect all the lines and cables. 11 Ensure RF cables are properly connected between the duplexer and RF connectors. TX signal: Excitor module -> PA module -> Duplexer TX connector -> Duplexer antenna connector -> RX/duplex antenna connector (rear panel) RX signal: RX/duplex antenna connector (rear panel) -> Duplexer antenna connector -> Duplexer RX connector -> RX module Diagrams of Assembled Unit Duplexer Mounted with Front Side Facing Upwards 12 Screws RF cables Screws Duplexer Mounted with Front Side Facing Downwards Electrical Connections After the repeater has been mechanically installed, electrical connections must be made. This involves making the following connections: DC power cord Antenna cables See the rear panel view for the positions of connectors. Power Supply Connections 1. Ground Connection The repeater is equipped with a ground screw located on the rear panel. Connect ground wires to the screw. 2. DC Power Supply or Battery Backup Connection 13 The repeater may be connected to a regulated DC power supply or a backup battery. The DC source or battery backup system is connected to the repeater through the DC power inlet at the rear of the repeater (see rear panel view). Caution: Before you make the connection, ensure the DC power supply or battery backup system is capable of supplying a minimum of 200W, and check if the DC power supply has current limit. Since high current consumption is required for transmitting, improper setting of the current limit may cause transmission failure. Caution: The repeater is to be connected to a battery that is in accordance with applicable electrical regulations for the end use country. If battery power is exhausted, you are recommended to charge the battery with an external charger. Remove the battery from the repeater when charging. RF Antenna Connections TX and RX antennas are connected to two separate connectors (shown in the rear panel view), and there must be adequate isolation of 75 dB UHF or 85 dB VHF between them. If only one antenna through a duplexer is connected, at least 75 dB UHF or 85 dB VHF isolation between the TX and RX antenna ports is required. Caution: Please ensure that all power is switched off before disconnecting the TX antenna. 1. Duplexer Selection The selection of duplexer is critical to system performance. The use of a notch (band reject) duplexer is possible in some systems that are not located at high RF density sites. If the repeater is used in high RF density sites, the use of a pass-notch duplexer is recommended. The duplexer must be able to handle at least 50W continuously. For the best system performance, the insertion loss should be less than 2dB. 14 2. Antenna Selection The selection of antenna is also critical to system performance. The selected antenna must be 50 Ohm impedance and capable of at least 50W. High gain antennas may be used to increase system coverage. Please take note of licensing restrictions when selecting high gain antennas. Some services or regions may have antenna gain or system radiation limitations. The antenna must be connected to the duplexer with a high grade 50 Ohm transmission line (e.g. Andrew HELIAX cables). The line must have connectors to match the connectors on the duplexer and antenna. Caution: It is important that all antenna cables are grounded at the point they enter the building. All aspects of the antenna design must comply with the relevant local regulations. Post-Installation Checklist After the repeater has been mechanically installed and all electrical connections have been made, power may now be applied and the repeater should be checked for proper operation. 1. Applying Power Before applying power to the repeater, make sure all boards are securely seated in the appropriate connectors on the rear panel and all RF cables are securely connected. Turn on the DC power source to supply power to the repeater. 2. Verifying Proper Operation Operation of the repeater can be indicated by the 8 LEDs located on the front panel and also by LCD prompts. Caution: Some repeater components can become extremely hot during operation. Turn off all power and wait until the repeater is sufficiently cool before touching the repeater. 15 Status Indications LCD Icons The LCD of your repeater displays the repeater status and menu items. The following are the icons that appear on the display. Standby Screen Status Icon (Tx power) Repeater Mode Channel Alias (programmable by dealer) Status Icons Icon Name Transmit Icon Power Icons Repeater Status Low TX power for the current channel High TX power for the current channel LED Indicator LED Indicator Repeater Status Power Indicator glows green Repeater being turned on Repeater giving an alarm due to failure of some component (please observe the LCD prompt, Alarm Indicator glows red and carry out troubleshooting as the “Alarm Information” section instructed.) Repeater Mode Indicator glows green Repeater operating in Repeater Mode (RM) Repeater Mode Indicator is not lit Repeater operating in Repeater Base Mode 16 (RBM) Repeater transmitting (analog) repeater Slot 1 TX Indicator glows red transmitting on slot 1 (digital) Slot 1 TX Indicator flashes red Busy channel lockout * / transmission time-out * Slot 2 TX Indicator glows red Repeater transmitting on slot 2 (digital) Slot 2 TX Indicator flashes red Busy channel lockout * / transmission time-out * Slot 1 RX Indicator glows green Repeater receiving (analog) / repeater receiving on slot 1 (digital) Slot 1 RX Indicator flashes green Monitoring * Slot 2 RX Indicator glows green Repeater receiving on slot 2 (digital) Analog Mode Indicator glows yellow Repeater operating in analog mode Digital Mode Indicator glows blue Repeater operating in digital mode Basic Operations Turning the Repeater On/Off Connect the repeater to a DC source to turn the repeater on. At this time, the Power Indicator glows green and the repeater shows the power-up screen. To turn the repeater off, disconnect it from the DC source. Adjusting the Volume When the repeater operates in analog mode, rotate the Volume Control knob clockwise to increase the volume of speaker output audio, or counter-clockwise to decrease the volume. When the repeater operates in digital mode, the speaker cannot output audio, and no 17 volume adjustment through the knob is available. Adjusting Power Level You may request your dealer to set the TX power to high or low. The LCD displays icon for high power, and icon for low power. High power can optimize coverage of the repeater, to communicate with farther terminals. Backlight In insufficient light conditions, activating the backlight can illuminate the LCD and all the front panel keys, facilitating user operation. You dealer may set the backlight to operate in any of the following modes: Timed: any key or knob operation or receiving/transmitting of signals can illuminate the backlight. If none of the above operations is made within the specified time period, the backlight will go out automatically. Enable: Since the repeater is powered on, the backlight will remain illuminated all the time. Disable: The backlight will always remain disabled. Note: When an alarm indication occurs, the backlight will remain illuminated until the alarm disappears. Then it will recover the initial operation mode. Locking/Unlocking the Front Panel Your dealer may lock all the front panel keys and knobs, to prevent accidental operation. Note: To unlock the front panel, the repeater must be re-programmed by your dealer. 18 Menu Navigation Under this menu, you can view the basic information of your repeater, including serial number, radio model, frequency range, firmware version and etc. To access this menu: 1. In the home screen, press the Menu Navigation knob to enter the main menu. 2. Rotate the knob to select the "Radio Info” option. 3. Press the knob again to view basic information of the repeater. Then you may rotate the knob to scroll up/down. To exit, just press the knob. 19 Channel Info Under this menu, you can view some information of the current channel, including channel alias, TX/RX frequency, channel spacing (analog only), TX/RX CTCSS/CDCSS (analog only), color code (digital only) and etc. To access this menu: 1. In the home screen, press the Menu Navigation knob to enter the main menu. 2. Rotate the knob to select the "Channel Info” option. 3. Press the knob again to view information of the current channel. Then you may rotate the knob to scroll up/down. To exit, just press the knob. Exit To exit from the main menu, rotate the Menu Navigation knob to select the "Exit” option, and then press the knob. Alarm Information The repeater can automatically detect its operation status in real time, such as PA over-temperature, low forward power, high VSWR, high/low voltage and fan failure. When any of the above occurs, the LCD will give you a prompt, and the Alarm Indicator will glow red. 20 Over Temperature Alarm When temperature of the PA module exceeds the normal range, the Alarm Indicator will glow red and the LCD will display the prompt below: Then the repeater will disallow transmission, and you will need to: 1. Check if the surface temperature of PA heatsink exceeds 80℃. If yes, implement the following steps 2 and 3 to locate the failure. Caution: The PA heatsink can become extremely hot at this moment, so DO NOT touch the repeater. Use a digital thermometer with thermocouple to measure temperature. 2. Check if ambient temperature and equipment ventilation can satisfy the foregoing site installation requirements. If not, please improve environmental conditions at the site as soon as possible, by mounting air conditioning equipment or improving equipment ventilation. 3. Check if connection between the transmitter and RF or antenna cables is loose or lost. If yes, please secure the connection or replace the cables. Poor connection between them could result in very high TX power and thus high temperature of PA heatsink. 4. If you are unable to verify the above conditions, please contact your local dealer for technical support. When temperature of the repeater drops into the normal operating range, the LCD prompt will disappear, and the Alarm Indicator will go out. Fan Failure Alarm When the fan fails to work, the Alarm Indicator will glow red and the LCD will display the 21 prompt below: Then the repeater will automatically switch to low TX power, to protect the transmitter from overheating. You will need to: 1. Check if the fan is blocked by any solid object. If yes, please remove it. 2. If you cannot solve the issue, please contact your local dealer for technical support. When the fan recovers normal operation, the LCD prompt will disappear, and the Alarm Indicator will go out. VSWR Alarm High VSWR (voltage standing wave ratio) at the TX antenna connector will result in damage to the PA, and even failure of the transmitter. When the VSWR exceeds the normal range, the Alarm Indicator will glow red and the LCD will display the prompt below: Then the repeater will automatically switch to low TX power. You will need to: 1. Check if the TX frequency is within the frequency range of the antenna. If not, please contact your local dealer to replace the antenna. Improper antenna selection could 22 result in poor transmitting performance, and even damage to the transmitter. 2. Check if connection between the transmitter and RF or antenna cables is loose or lost. If yes, please secure the connection or replace the cables. 3. If you cannot solve the issue, please contact your local dealer for technical support. When the VSWR falls within the normal range, the LCD prompt will disappear, and the Alarm Indicator will go out. Low Forward Power Alarm When the forward power is below the preset value, the Alarm Indicator will glow red and the LCD will display the prompt below: Then the repeater may continue transmission or may terminate it, subject to repeater status currently detected. You will need to: 1. Check if connection between the transmitter and RF or antenna cables is loose or lost. If yes, please secure the connection or replace the cables. 2. If you cannot solve the issue, please contact your local dealer for technical support. When the forward power is recovered to its normal value, the LCD prompt will disappear, and the Alarm Indicator will go out. Over/Low Voltage Alarm When voltage is over or below the normal operating range (11V-15.6V) of the repeater, the Alarm Indicator will glow red and the LCD will display the prompt below: 23 Low Voltage Alarm Over Voltage Alarm Then the repeater will automatically shut off, but the LCD prompt will remain. You will need to: 1. Use a voltmeter to check if the input voltage of DC power supply is normal, especially if the voltage will run below the normal range while transmitting. If yes, please replace the DC power supply or backup battery. 2. Check if connection between the repeater and the DC power cord is loose or lost. If yes, please secure the connection or replace the cable. 3. If you cannot solve the issue, please contact your local dealer for technical support. Caution: If low voltage is detected when the repeater is powered by backup battery, you need to charge the battery with an external charger. Remove the battery from the repeater when charging. When voltage falls within the normal range, the LCD prompt will disappear, and the Alarm Indicator will go out. 24 Troubleshooting Phenomena Analysis Solution a. Properly connect the power cord a. Power cord is not connected or is and ensure secure connection. The repeater cannot not securely connected to the be powered on. outlet. b. Check if the DC fuse has blown, and if yes, replace it with a new b. Power cord fuse is damaged. one. a. TX/RX frequency of the repeater Group members a. Re-set frequencies. is inconsistent with that of cannot talk to each b. If you cannot remove or bypass portable/mobile terminals. other, or the repeater the interference source, change to b. Failed to repeat useful signal due cannot communicate operate on other frequencies. to strong interference signal. with a subscriber c. Go within the coverage of the c. The group member is out of the radio. repeater. coverage of the repeater. Group members cannot talk to each other, even though RX indication is a. Your ID is inconsistent with that of other group members. a. Set your ID to the same as that of other members. b. Inconsistent CTCSS/CDCSS. b. Re-set CTCSS/CDCSS. a. Leakage of signal energy due to a. Replace the cable with a new one given. damaged connection cable. b. Loose connection between if necessary. b. Secure the connection or replace Short antenna connector and the cable, cable plug with a new one if or loss of connection necessary. communication range or poor audio c. Invisible damage of cable. c. Replace the cable with a new one. d. Duplexer is not properly set (if d. Contact the manufacturer or your duplexer is mounted). dealer to re-set the duplexer. 25 If the above solutions can not fix your problems, or you may have some other queries, please contact us or your local dealer for more technical support. Care and Cleaning To guarantee optimal performance as well as a long service life of your repeater, please follow the tips below. Repeater Care Keep the repeater at a place of good ventilation and heat dissipation to facilitate normal work. Do not place irrelevant articles on top of the repeater to ensure optimal heat dissipation. Do not place the repeater in corrosive agents, solutions or water. Repeater Cleaning Clean up the dust and fine particles on the repeater parts with a clean and dry lint-free cloth or a brush regularly. Use a non-woven cloth with neutral cleanser to clean the keys, control knobs, LCD and jacks after long-time use. Do not use chemical preparations such as stain removers, alcohol, sprays or oil preparations. Make sure the repeater is completely dry before use. Caution: Power off the repeater before cleaning. 26 Optional Accessories Contact your local dealer for the optional accessories used with the product. Caution: Use the accessories specified by Hytera only. If not, Hytera shall not be liable for any losses or damages arising out of use of unauthorized accessories. 27
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract, Print high-res Author : a Create Date : 2013:05:16 16:08:39+08:00 Modify Date : 2018:03:19 17:55:31-07:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2018:03:19 17:55:31-07:00 Format : application/pdf Title : Microsoft Word - RD98XS Owner's Manual 100202.doc Creator : a Producer : Acrobat Distiller 9.0.0 (Windows) Document ID : uuid:a46efedd-d084-428e-9de8-b91f53ead2d3 Instance ID : uuid:5b51fd5d-695a-4688-844a-b32192eebc0e Page Count : 28EXIF Metadata provided by EXIF.tools