ICP DAS ZM31001100-PA Wireless Module User Manual 6 User s Manual V2

ICP DAS Co., Ltd. Wireless Module 6 User s Manual V2

Users Manual

ZM-1100-PA/ZM-3100-PA User’s Manual, Ver. 1.0                                Page 1  ZM-1100-PA/ZM-3100-PA User’s Manual   Warranty All  products  manufactured  by  ICP  DAS  are  warranted  against defective materials for a period of one year from the date of delivery to the original purchaser.  Warning ICP DAS assumes no liability for damages consequent to the use of this product. ICP DAS reserves the right to change this manual at any time without notice.  The information  furnished by ICP DAS is believed to be accurate and reliable. However, no responsibility is assumed by ICP DAS for its use, or for any infringements of patents or other rights of third parties resulting from its use.  Copyright Copyright 2013 by ICP DAS. All rights are reserved.  Trademark The  names  used  for  identification  only  may  be  registered trademarks of their respective companies.
ZM-1100-PA/ZM-3100-PA User’s Manual, Ver. 1.0                                Page 2 1. Introduction The  ZM-1100-PA/ZM-3100-PA  is  a  FCC  certified  design  and  a  small-sized  wireless-UART converter solution consisting of a micro controller unit with RF transceiver and a RF power amplifier front-end,  or  often  called  the  low-noise  amplifier  (LNA),  and  it  offers  excellent  the  sensitivity.  ZM module is based on the 2.4 GHz IEEE 802.15.4 standard, and it contains ZigBee firmware and can be controlled through an external host/system microcontroller or external evaluation software through the  UART interface. We use the  same  hardware but  the  different firmware  to achieve  the  ZigBee Coordinator or Router.    2. Models ZM-1100-PA/ZM-3100-PA module is intended for OEM integrator. The modules includes PA/LNA, Dipole Antenna Connector. It depends on market positioning to install firmware.  3. Features • 48.1 mm x 29 mm PCB   • 7x2 mm spacing pin connector • Utilizes globally available 2.4 GHz ISM band • Control and Configuration with specific commands via UART@115.2Kbps. • Programmable Transmit Power Output, Max 1 dBm. • Typical Receiver Sensitivity -97dBm. • Typical Data Rate 250Kbps. • Complete IEEE 802.15.4 Spec. compliant. • ZigBee 2007 Pro installed. • 65527 unique node addresses. • Typical transmission range 700 meters(Line of Sight). • Required Supply Voltage: 2 to 3.6VDC. • Operating Temperature: -25°C to +75°C • Storage temperature: -40 to +80°C • RoHS.  4. Protocol Overview The  bidirectional  data  exchange  between  an  external  host/system  microcontroller  and  the ZM-1100-PA/ZM-3100-PA  uses  the  hardware  UART and  follows  the  RS232  protocol.  This  RS232 protocol is summarized in Table 1.  Table 1. Host RS232 Serial Interface Communication Parameters PARAMETER PARAMETERS  DESCRIPTION Baud Rate  115.2Kbps Start Bits  1 Data Bits 8  8 Stop Bits 1  1 Parity None  None
ZM-1100-PA/ZM-3100-PA User’s Manual, Ver. 1.0                                Page 3 FCC Statement:  Federal Communication Commission Interference Statement   This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  B  digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against  harmful  interference  in  a  residential  installation.  This  equipment  generates,  uses  and  can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause  harmful  interference  to  radio  communications.  However,  there  is  no  guarantee  that interference  will  not  occur  in  a  particular  installation.  If  this  equipment  does  cause  harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.  FCC Caution: Any changes or modifications not expressly approved by the party   responsible for compliance could void the user’s authority to operate this equipment.  This  device  complies  with  Part  15  of  the  FCC  Rules.  Operation  is  subject  to  the  following  two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  This  device  and  its  antenna(s)  must  not  be  co-located  or  operation  in  conjunction  with  any  other antenna or transmitter.  IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
ZM-1100-PA/ZM-3100-PA User’s Manual, Ver. 1.0                                Page 4 IMPORTANT NOTE: This  module  is  intended  for  OEM  integrator.  The  OEM  integrator  is  still  responsible  for  the  FCC compliance requirement of the end product, which integrates this module.  20cm minimum distance has to be able to be maintained between the antenna and the users for the host this module is integrated into. Under such configuration, the FCC radiation exposure limits set forth for an population/uncontrolled environment can be satisfied.    Any  changes  or  modifications  not  expressly  approved  by  the  manufacturer  could  void  the  user's authority to operate this equipment.  USERS MANUAL OF THE END PRODUCT: In  the  users  manual  of  the  end  product,  the  end  user  has  to  be  informed  to  keep  at  least  20cm separation with the antenna while this end product is installed and operated. The end user has to be informed that the FCC radio-frequency exposure guidelines for an uncontrolled environment can be satisfied.  The  end  user  has  to  also  be  informed  that  any  changes  or  modifications  not  expressly approved by the manufacturer could void the user's authority to operate this equipment. If the size of the end product is smaller than 8x10cm, then additional FCC part 15.19 statement is required to be available in the users manual: This device complies with Part 15 of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.  LABEL OF THE END PRODUCT: The final end  product must  be  labeled  in  a  visible area  with the  following "  Contains TX FCC ID: Q6M-ZM31001100-PA". If the size of the end product is larger than 8x10cm, then the following FCC part 15.19  statement has  to also be  available on  the label:    This device complies with Part 15  of FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference  and  (2)  this  device must  accept  any  interference  received,  including  interference  that may cause undesired operation.

Navigation menu