ICP Package Units(both Units Combined) Manual L0611131
User Manual: ICP ICP Package Units(both units combined) Manual ICP Package Units(both units combined) Owner's Manual, ICP Package Units(both units combined) installation guides
Open the PDF directly: View PDF .
Page Count: 12
Download | |
Open PDF In Browser | View PDF |
Installation Instructions PAM3 SERIES PACKAGE AIR CONDITIONERS TABLEOF CONTENTS SAFETYLABELINGAND SIGNALWORDS ....................... 2 FINALELECTRICALCHECK .................................. 6 UNITDIMENSIONS ......................................... 3 CONTROLBOX CONFIGURATIONAND WIRING ................... 7 SAFEINSTALLATIONREQUIREMENTS ......................... 3 WIRING DIAGRAMS ........................................ 8 LOCATINGTHE UNIT ....................................... 3 RAINSHIELDINSTALLATION................................ 10 CLEARANCES ............................................ 4 AIR DISTRIBUTIONSYSTEM................................. 10 INSTALLATION............................................ 4 DUCTWORK............................................. 10 INSTALLINGDUCTCOLLARS................................. 4 FILTERS ................................................ 10 CONDENSATEDRAIN....................................... 5 START-UP PROCEDURES.................................. 1! UNITELECTRICALWIRING .................................. 5 SPEEDTAPS ............................................ 1! LINEVOLTAGE............................................ 5 CHECK BEFORESTARTING................................. 1! CONVERTING230VTO208V ................................. 6 DEFROSTINTERVAL ...................................... 12 LOWVOLTAGEWIRING ..................................... 6 SEQUENCEOF OPERATION................................. 12 THERMOSTATCONNECTIONS ................................ 6 OPERATION ............................................. 12 0 us LISTED Printed in U.S.A. 11/8/05 426 01 1101 0O 1. Safety Labelinq and Siqnal Words Danger, Warning and Caution The signal words DANGER, WARNING and CAUTION are used to identify levels of hazard seriousness. The signal word DANGER is only used on product labels to signify an immediate hazard. The signal words WARNING and CAUTION will be used on product labels and throughout this manual and other manuals that may apply to the product. Danger Label White lettering on a black background except the word DANGER which is white with a red background. Signal Words DANGER - Immediate hazards which WILL result in severe personal injury or death. Warning WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death. White lettering on a black background except the word WARNING which is black with an orange background, Label CAUTION - Hazards or unsafe practices which MAY result in minor personal injury or product or property damage, Signal Words in Manuals The signal word WARNING is used throughout this manual in the following manner: Caution The signal word CAUTION is used throughout this manual in the following manner: Label White lettering on a black background except the word CAUTION which is black with a yellow background, Product Labeling Signal words are used in combination with colors and/or pictures on product labels. Following are examples of product labels with explanations of the colors used, 2 426 01 1101 00 2. Dimensions DIMENSIONS Unit PAM324/ 30 PAM336to 54 IIIIII I I il ADim. All dimensionsin inches (mm) 32-3/8 (821) 40-3/8 (1025) I I Rlllllllil II RIIIIIIIil II BIIIIIIIil II _IIIIIII'I II RIIIIIIII II RIIIIIII,I II _lllllllil II _lllllllil II lllllllllil II ,.,,,,,,. ,, _. ROUNDFLANGEWILL ACCOMMODATE14" DIA. RETURNDUCT COIL ACCESS PANEL 1-3/8" (36) CONNECTION 3O" PRESSURE! PORTS L_ (301) (232) 41-1/8" (763) (lO45) 51" (1295) 7/6"LowVoltage Wiring F (22) 36-1/3" (923) 1-1/4" 1-1/4" (33)* (35)* * ELECTRICALACCESSFOR UNE VOLTAGEPOWERSUPPLY-ONEFORUNIT, ONE FORHEATER 3. Safe Installation Requirements • Check to see that filters proper type and size. NOTE: FIRE, EXPLOSION, ELECTRICAL personal responsibility correctly and and are the obligation of the customer to contact a qualified installer to ensure that the installation is adequate and conforms to governing codes and ordinances. SHOCK HAZARD Installation or repairs made by unqualified persons can result in hazards to you and others. Installation MUST conform with local building codes or, in the absence of local codes, with the ANSI Z223.1 and the National Electrical Code NFPAT0-current edition or in Canada the National Standard CAN/CGA B149-1 and CSA C.22.1 Canadian Electrical Code Part 1. REDUCED UNIT LIFE HAZARD Failure to follow property damage this caution may result in Do NOT operate unit in a corrosive atmosphere containing chlorine, fluorine, or any other corrosive chemicals. Failure to carefully read and follow all instructions in this manual could result in furnace malfunction, property damage, personal injury and/or death. The information contained in this manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments. • Seal supply and return air ducts. 42601 1101 oo It is the are installed 4. Locating The Unit The unit is designed a platform at ground for outdoor installation only. Place the unit on level. The unit may be installed on a concrete slab of 48" (1219mm) x 48" (1219mm) dimensions. blocks on a 3" sand footing will also work. The slab 3 Concrete or blocks SHOULD NOT be in contact with any part of the structure. Check local codes covering zoning, noise, platforms, etc.. Avoid locating Noise next to fresh air intakes, may carry into the openings vent or bedroom and disturb people NOTE: windows. inside. Avoid installations under roof overhangs without guttering. Water draining from the roof onto the unit could produce excessive noise, and may cause ice to build up on coil or fan. Placement MUST of the unit should be supported be in a well drained high enough Installation The unit must be installed with a slope no greater than 1/8" per foot (10mm per meter). For side to side leveling, the condensate drain side side MUST always be lower. area or the unit so runoff will not enter the unit. Do not locate unit where heat, lint or exhaust discharged on unit (as from dryer vents.) fumes The unit MUST be situated access for servicing. wil! be Minimum clearances, as specified in FIGURE 1, MUST be maintained from adjacent structures to provide adequate air circulation and room for service personnel. Position platform separate from the building's foundation. While minimum clearances are acceptable for safety reasons, they may not allow adequate air circulation around the unit for proper operation. Whenever possible, it is desirable to allow Do NOT clearance, openings. install especially air from ACCESS Access or confined the condenser to Combustible Panel Side area that to recirculate (Wood 1.Remove the collars from under the blower motor. 30" (762mm) Side ....... 30" (762mm) between Clearance and Top of Unit around Condenser 2.Position flange holes with existing screw holes on side wrapper. 3.Install screw in each collar so it goes through both of the holes in the collar and wrapper. ..................... 0" ............................ 0" FIGURE2 ........................................ Clearance Duct Collars Duct collars are supplied with the unit but are not factory installed The collars are shipped under the blower motor. See Figure 2. or Class A, B or C material) to allow for proper to the Construction .................... Supply and Return Air Ducts Duct Connection Side FIGURE Platform MUST be high enough condensate drainage. will Base roof covering of the winter inlet and CLEARANCES Evaporator/Electrical Access Panel OPERATIONAL CLEARANCES Combustible the condenser install in a well-drained area, with the top surface platform above grade level and above the average snow levels to prevent coil blockage. Installing Minimum Clearances Blower around the unit in a recessed permit discharged condenser inlet. SERVICE safe The platform may be made of either concrete or pressure treated wood and MUST be level and strong enough to support the unit's weight. Clearances additional discharge in such a way as to provide 0 sl I Duct Collar Installation Control Box Overhang i ................ 48" (1219mm) Coil area to wall or shrubs . 10" Minimum Clearances and Access Panels Overhang Evaporator AccessPanel 48" MinimumOverhangClearance f 10" around condenser coilarea BlowedElectrical AccessPanel Collars Installed CoverPlate 4 Indoor Fan Assy. Collars Shipped with Unit 426 01 1101 00 Condensate Drain The condensate PVC connection evaporator access The circulating 5. Unit Electrical Wiring drain outlet is a 3/4" (19.1 mm) threaded female located at the bottom of the unit to the left of the panel. blower and the condenser fan create ELECTRICAL a negative pressure on the condensate drain line that wil! prevent the condensate from draining properly without a trap. To combat this negative pressure, a field supplied condensate trap that will allow Failure to follow this warning could result in personal injury, and/or death. a standing column of water of at least 2" (50.8mm) MUST be installed. The outlet of the trap must be at least 1" below the unit drain connection. Install the trap as near to the unit as possible for proper Turn off electric power supply at disconnect switch or service panel before removing any access or service panel from unit. drainage. A 3/4" (19.1 mm) drain line MUST be installed if required by local codes or if location of unit requires it. Run the drain line to an open drain or other suitable disposal point as designated by local code. FIGURE 3 Condensate Unit MUST be grounded to electrical service panel. NOTE: All electrical work MUST conform with the requirements of local codes and ordinances and in the United States with National Electrical Code ANSI/NFPA 70-1990 (or current edition). Provide line voltage power supply from a separate fused circuit with a disconnect switch (when required) located within sight of the unit. Supply voltage, amperage, fuse and disconnect switch sizes MUST conform with local codes and ordinances. Drain Information* 3/4" (19,1mm) Threaded Female PVC Fitting 1,, (25.4mm) I SHOCK HAZARD. Wiring MUST be protected from possible mechanical damage and MUST NOT interfere with removal of access panels, filters, etc. 3/4" (19,1mm) Drain Line All exposed line voltage connections MUST be made through liquid tight conduit to prevent water from entering the unit through the electrical access.. Ground * Condensate trap MUST be installed. Connections A ground lug is installed on the control plate (or electric heat mounting plate) for the ground connection. Use a copper conductor of the appropriate size (as designated by local code) from the unit to a grounded connection in the electrical service panel or to a properly driven and electrically grounded ground rod. See warning on this page. Line Voltage Wiring Do NOT complete line voltage connections until unit is permanently grounded. All line voltage connections and the ground connection MUST be made with copper wire. Connections for line voltage are made on the unit electrical control plate. For access, remove the Blower/Electrical access pane!. Refer to applicable wiring diagram in this Manual. Complete the line service connections to the contactor 'L' terminals on the electrical control plate. Check all screw terminals to ensure they are tight. NOTE: All openings must be sealed to prevent moisture from entering the control box. Electric Heat A variety of accessory electric heaters ranging from 5.0 to 20.0 KW provide heat in the unit when required. Each package has a heater module that mounts on the blower inlet; mounting this module requires removal of the blower assembly and attachment of the module to the blower standoffs provided. Each package also includes an associated remote mounted heater control package. Integral harnesses provided with both the heater module and control package allow connection of the two components via in-line plugs. Heaters are available both with and without circuit breakers. See installation specific 426 01 1101 00 5 instructions installation provided and application with the electric details. heater for Converting To convert 230V 230V Units to 208V GuRE4 units to 208V: Narness Connection D agram Therm°stat L°w V°ltage wiring I Electr°nic PAM324-42 1 .Turn electric 2.Remove 3.Locate power © @ OFE the blower/electrical the 24V control access panel. transformer. 4.Remove wire from the terminal labeled "240V" on the 24V control transformer and reconnect it to the 208V terminal of the 24V control transformer. &Replace Low the electrical/compressor access remove the electrical panel. Refer to the connection and to the instructions access wiring diagram for the applicable included with the thermostat. Route low voltage wires through and up to the control box. Thermostat control/blower the port located panel. model Thermostat and subbase t Unit Control PAM348-54 Connections See FIGURE 4 for BRN on the rear panel Low Voltage Wire Power Units C>@ The location of the thermostat has an important effect on the operation of the unit. See the thermostat instructions for proper connection. Connections ._ G Voltage Wiring For access, Units Harness Field Installed Equipment @- Wiring to be done in the field between the unit and other devices, or between separate devices which are field installed and located, MUST NOT exceed the temperature limitations for type T wire and MUST be installed in accordance with manufacturer's instruction and applicable ®- local codes. Final Electrical Check Make a final wiring check to be sure system is correctly wired. Thermostat and subbase Inspect field installed wiring and the routing to ensure that rubbing or chafing due to vibration will not occur. NOTE: Wiring MUST be installed so it is protected from possible mechanical damage. Unit Control 6 Power 426 01 1101 O0 FIGURE 5 I Control BoxConfiguration Indoor Motor Board Capacitor Strap / / Transforme Condenser Fan/ Compressor Capacitor / Control Box \ Contactor Low Voltage Shield Control Box Wiring for PAM024-42 _2b_K [ II ...... ® __o_ POWER PIGIAItS o _II_ o _ _I_ jo_ :_ oI, Wl)_LK_ 2 ................. _f(T) HIt IIi 2_V PIGTAI£$ _IF] _EI_IL _rROST'A" TIWERTO BE SE_ AT_o wiwuT_s SINGLECAPACITYCONTROLBOX - 208/230/1 Control Box Wiring for PAM048-54 _olo_ b_JI II ....... POWZR PIGIAILS 0 IIIIIIH Z4v PIGIAILS DUAL CAPACITY CONTROL BOX (D_}_llpOSTION_ 42601 1101 O0 7 208/23D11 2-31/2 Ton Models SCHEMATIC 2081230-1-60 CCH FIELD _,ITO,L, Z_IT " '_:_B_ L-- t . _i"-X_ [ _BL_ -- [ EOUIP.GHDT | [ ]I] C ACCESSORY -- _l ELECTRIC w/o ce's 5"I0 kw HEAT _I /_ I_ -- EL_--___-7% HTR[I I " / BLH-- -- I _/ F _oe _eo [ III [lI I IlI ' w_lYEL SEE e_)T_ V_9 BRH CIRCUIT 8REA_ERS SHOWN WIT_@ SINGL_ PO]N; KIT _3_ BLO_ _S_ ORH R----_REO-Y_YEL-- W2"---------_'_r-WHT-ACC[SSSORY ELECTRIC BEAT_ HRI (5 KW)_ HR1,2.3 BR#-- & 4 1_0 XW}_ rio GRY HRI,? & 3 (15 KW}_ W3-_VIO-PNK CTO {tl,T_l C----_BRN LEGEND UNIT COHPOHZNT ARRANGEMENT ffflO SPliCE O I_RWI_AL Iwk_ltg RGIZ[O o l{_Z._t lu_mA_e_ CAP $£¢TION FAN O_TOC_R OSPtlC{ COMPRESSOR S[CIIOII INDOOR S[CTIOW _A# IWAR_{[O) - - fIEtO ¢_IgC_ WIRING --" fIILO _eOe_R_[_I_ --.. ACC{SSO_IC_ OPIIONAL IlRI_ --TO IWI)ICAIE CC¢_0_ _](NtlkL O_LY: _I IO R{PR{S{_I II_{_ BOARO c C_IPRES$OR O£LA¥ | , , I 0 .5 SIC ! T'_ WI_. C1 ¢1 CLOSES OPENS TSA1 /EOOIP, G#O ¢AeA¢ltO_ _H A _ AT R CtO COWPRISSO_ IIW_ OELAI 0tt 09 {C8 GNO WR lrw LP$ e_w RVS TR_ oEt_t I_R_IAI O[iK_)ST_(LAT ik# C_TROt EOARO G_,O_0 g{klIR RELAI IWOOOR FANWOTOR L_ _RI$S@R]{Sl[I{# o_ioooe_A_ woi_ R{V£_SI_ VALVESOLEWOIO T_A_SrOR_ {kw SEOUE_[ I 6 ¢ G CO_T_T_ O{.[_(RGIZ_O s 8 42601 1101 O0 4 & 5 Ton Model FIELD UNIT ONLY CCH _ WI_ OLK EOUIP.GNDT | UN,T,,0I,_ ,1 ACCESSORY ----------m_ 5"10 __ kw °LK-- ?/_ 0 BLE i II I _ EL++-:+___-'+Tn HTe ) I L__ , I111 '- 1111 COMP SOLENOIO -- J i L+o._ [W)_CHTcEBC_ sHEAT V,++, SINGLE POINT KIT G _6_Ni OLK Y_YEL-- B_N W2i-_!_--WHT - ,<<,+,,_,<,_,< +,___ HR1 & _ (I0 w3_VIO R1,2 i Ell) GRY PNX ))_SR# &O)RN(15 EW (( -- t!] +i C_BRN LEGEND UNIT COMPONENT ARRANGEMENT _(DOOR tAN ;[ClIOg )ECl(OII 00 Itm_(l_. l[IMt_aL I_KEDI (U_WlI(O) itkCtOf(t IiRINO - -rffLO CONTROL lll+llm --_IELO FOIE+tIIII_ SECtiON lll+)l_O H I_S; e( e[_(o sff e_lCt e_$ 1101 O0 m+ _t (m _£tROSt BOARD O_rROSTT.[e_OST_ O[teOSTIEL_Y GNO P,_O_D m_vs fe_ CO¢(P 42601 CO_T_TO_ CAPA¢ItOe _O/_l_tlkL ONLY (FM _Ot to _EPRES_N1 IIR_NO LPS CONTROL _EOUIP 80kR) GXO i_v CCAe PO_R ENTRY i)t++ _+e( so _oe[t (_ fN_ NOTO_ _01 PRESS_E SIlkeN N_VERSI_ VN[VE SOUl,OlD 1R_NSrOR_E_ c Ul._ o_ +i R(LOCAt[OI_O( $P(EOTA?S_i_ _,( t(OQIRED w_(_ ilstlI rfflo INSl_O [Lt¢l_i¢ .[_izlls. ¢O_I_T I_Sl_l_lI_ I_STll_il_S To ll[lll_l"[ C_IICT SPII_ l_e S[TII_ 9 €TO (lt+t_l FAN S(O_[NC[ I _oe te_mlo_t_t xkO S_AS_S. G [N[R_IZ[D OE+[IERGI_[O CC¢_PRESSOJ_ DELAY I , , , r 0 +_ SEC T T+5 MIM. ¢1 ¢1 CLOSES OPENS TSAI 6. Rain Shield Installation requirements. If the unit is connected to an existing system, ductwork MUST be checked to make sure it is adequate. runs or larger duct sizes may have to be installed. FIGURE 6 [ Maximum Installing The Rain Shield recommended velocity in trunk ducts the Extra is 1000 feet per minute (5.08m/s). Velocity in branches should not exceed 800 feet per minute (4.06m/s). Refer to the Technical Data Label on the unit for unit air volume requirements and system sizing recommendations. RAIN SHIELD NOTE: Ductwork sizing affects temperature rise and cooling temperature differential. Be sure to properly size ductwork to the capacity and airflow characteristics of your unit. Failure to do so can affect limit controls, compressors, motors, and other components and will lead to premature failure of components. This will also adversely affect day to day unit performance. Flexible Duct Kits are available from your supplier to effect proper sizing and installation to Mobile Homes and other standard construction,. Refer to unit rating plate for proper Electric Heat Accessory sizing and see the Temperature Rise Check section in the Electric Heat Accessory Installation manual. 1. Remove all screws from the cover plate on Blower/Electrical Access Panel. 2.Install adhesive backed gasket on Blower/Electrical Panel. 3.Install lower frame 4.Install rain shield 5.Install slot.) circuit &Re-install Access of rain shield with 4 screws. hinged breaker cover with 4 screws. filler Blower/Electrical plates (2 each per unused Access NOTE: VERIFY ALL APPROPRIATE SEE FIGURE 6. 7. Air Distribution breaker Panel. SEALS Ductwork Insulation It is recommended that ductwork installed outdoors have a minimum of 2" (51 mm) of fiberglass insulation and be covered by a weatherproof vapor barrier that is protected against damage. Caulking and flashings, or other means adequate to provide a permanent weather seal, must be used. It is recommended that ductwork installed in attics or other areas exposed to outdoor temperatures have a minimum of 2" (51mm) fiberglass insulation and have an indoor type vapor barrier. Ductwork Connections ARE IN PLACE. System The use of flexible, non-combustible connectors between main trunk ducts and supply and return air plenums is recommended to minimize vibration transmission. For airflow data (blower performance data, blower speed tap settings, etc.) see the Technical Data Sheet attached to the unit. NOTE: Connect supply and return air plenums to unit in a manner that will allow the top of the unit to be removed without removing plenums. Plenums MUST be individually sealed to unit casing. Ducts MUST be terminated inside structure. Duetwork Filters NOTE: The total heat gain of the structure to be conditioned as expressed in total Btu/hr should be calculated by manufacturer's method or in accordance with "A.S.H.R.A.E. Guide" or "Manual J Load Calculations" published by the Air Conditioning Contractors of America. The total heat gain calculated should be equal to or less than the cooling capacity output based on D.O.E. test procedures, steady state efficiency times input. All return air MUST pass through a field supplied filter before entering the unit. if used, an electronic air cleaner MUST be installed in the return air ductwork. Minimum recommended filter areas are listed in FIGURE 7 and are based on a velocity of 300 ff./min. (1.2m/s) for disposable filters and 500 ft./min. (2.54m/s) for washable high velocity filters. Ductwork, supply registers, and return air grilles MUST be designed and sized to handle the unit's cooling air volume FIGURE 7 NOTE: Recommended NOTE: Do NOT operate the unit without all filters in place. Filter Sizes Some filters are marked with an arrow to indicate the proper direction of air flow through the filter. The air flow direction wilI be towards the blower motor. Make sure filter is installed correctly. Nominal Tons Air Conditioning 2 Recommended Filter Sizes Sq. In. Surface Area/Nominal Size Nominal Air Flow Cubic Feet per Minute Disposable 700-900 Filters Gleanable Filters 400 or 20 x 25 246 or 15 x 20 487 or 20 x 30 301 or 14x25 1050 -1350 576 or 14 x 25 (2Req.) 356 or 16x25 3 1/2 1225 -1575 865 or 16 x 25 (2Req.) 411 or 20 x25 4 1400-1800 753 or 20 x 25 (2 Req.) 486 or 20 x 25 5 1750 - 2000 960 or 20 x 30 (2 Req.) 575 or 24 x 25 2 1/2 875 - 1125 3 10 42601 1101 00 8. Start-up Procedures ELECTRICAL SHOCK HAZARD. 2. From the system pressure registers, design, determine the total external (ESP) for the supply ducts, diffusers, grilles, dampers, 3.To your system ESP determined in Step 2, add 0.05 In. W.C. for a wet coil. Failure to follow this warning could result in personal injury, and/or death. 4.From the system design, determine the desired airflow in cubic feet per minute (CFM). Use extreme care during all of the following checks and procedures. 5.Locate the unit's Blower Performance Data table From the table, determine the speed tap required the desired airflow. Make sure electric power i8 turned OFF as instructed in appropriate steps. in Figure 8. to achieve Speed Taps Blower Speed After determining the required CFM and speed tap data from the Figure 8, follow the steps below to change speeds if necessary. 1.Turn electric power OFF. FIGURE 8 cooling 6.See next section, Speed Taps, to set the blower motor speed terminal block (speed taps) to the cooling speed determined in the previous steps. Circulating Air Blower Determining static return ducts and heaters and filters. Blower Speed Tap Settings and Blower Performance Blower Speed Tap Settings Data See Figure 5 for Blower Speed Tap Pigtail Rated Airflow High Airflow 2 TON 21/2 TON Tap 1 Tap 2 Tap 2 Tap 3 3 TON Tap 1 Tap 2 31/2 TON Tap 3 Tap 4 4 TON Tap 3 (Hi); 1 (Lo) Tap 4 (Hi); 2 (Lo) 5 TON Tap 3 (Hi); 1 (Lo) Tap 4 (Hi); 2 (Lo) BLOWER PERFORMANCE DATA Model Number PHM324K00A1 Speed Tap 0.1 0.2 1 1078 833 2 1170 1102 0.3 0.4 0.5 0.6 (in, 0.7 0.8 783 720 681 615 489 435 1052 1006 964 921 881 838 0.9 1 378 317 789 684 Air Delivery in CFM@Varying External Static Pressure w.c.) Notes: NOTE: attached 3 - PHM330K00A1 4 1 2 3 1170 1266 1102 1221 PHM336K00A1 4 1 1420 1288 2 1497 1433 3 PHM342K00A1 4 2 PHM348K00A1 PHM354K00A1 3 4 1559 1694 1520 1657 1 2 3 1213 1299 1698 1028 1226 1652 4 1 2 3 4 1974 1389 1461 205C 2179 1924 1292 1417 2003 2132 909 825 762 667 613 1052 1006 964 921 881 838 1184 1152 1121 1089 1047 1017 1209 1170 1153 1106 1065 1011 1387 1334 1294 1292 1247 1203 1480 1438 1401 1359 1318 1268 789 684 985 951 967 910 1171 1117 1218 1389 1181 1620 1583 1550 1514 1474 1437 1157 1094 1037 961 915 841 1601 1542 1494 1442 1390 1324 1859 1228 1364 1963 2093 1813 159 1296 1923 2049 1761 104 1243 1874 2011 1706 1043 1180 1823 1968 1651 988 1129 1783 1921 1602 940 1083 1734 1877 769 719 1265 1201 1538 1485 873 828 1026 168C 1830 978 162,2 1760 Air Delivery @ listed external static pressre are taken at 230Volts with Dry coit, no filter and approved heater For wet coil add .05 in. wc to Static Pressure measurement Note for 208 Votts appIications, reduce airflow by 15% On Heat Pumps Electric heater blower wire must be to the same speed tap required for cooling/heat pump operation. The yellow lead MUST always be connected to the speed tap block at the common quick connect terminal. The terminal is identified as COM. HEATING SPEED, If auxiliary electric heat is installed, the auxiliary electric heat blower speed wire must be connected to the black wire Check Refer to Figures 5 and 8 and the appropriate unit wiring diagram included in this manual. Wire the black wire to the required speed tap terminal to achieve required airflow determined in Step 5. Cooling, Heating (Heat Pump) and Auxiliary Electric Strip Heat NOTE: The cooling, heat pump and strip heat airflows are all on the same speed tap. The refrigerant system requires the same specific CFM for proper operation in the cooling and the heat pump mode. For this reason, cooling and heating airflow must be the same. DO NOT SPLIT OUT INTO A COOLING SPEED AND 42601 1 1101 oo insulated Before quick connect terminal. Starting 1. Check that the blower motor speed terminal block is set to the proper cooling speed. Refer to the unit wiring diagram and the various airflow tables in this manual. 2. Check to see that clean, properly sized field supplied filters are installed in the return air duct. air 3. Inspect the inside of the unit to be sure that all wires place and all tools, etc. are removed. are in 4. Replace Check the instructions. 11 all service access unit's operation If any unusual panels. as outlined in the following sparking, odors or noises are encountered, shut OFF electric power immediately. Recheck for wiring errors, or obstructions in or near blower motors. Circulating Air Blower 1.Be sure electric power is OFE 2.Set thermostat Heat-Cool 3.Set thermostat fan switch selector to OFE Heating Operation (PAM324-42) (1) On a call for heating ......... : With a call for heating (W2), the auxiliary or electric heat energizes along with the Indoor blower. Incase of staged heating, W3 is energized if the demand is not met. The highest airflow selected is run while the electric heat is in operation. to AUTO 4.Turn electric power ON. Nothing should start running. 5.Set thermostat fan switch to ON. The circulating air blower should come ON. (2) When the heating setpoint has been satisfied When heating demand is met, W3 and W2 sequentially de-energize shutting off the indoor fan and the electric heater. Heating Operation (PAM348-54) 6.Reset thermostat fan switch to AUTO. The circulating air blower should go OFF after a 60 second delay for models PAM324-42 and 90 second delay for PAM348-54. Nothing should be running. Cooling (2) When the heating eetpoint has been satisfied When heating demand is satisfied, W3 and W2 sequentially de-energize along with the indoor fan blower. 1. Be sure that electric power is OFF. 2. Set thermostat (1) On a call for heating ......... : With a call for heating (W2), the auxiliary electric heater is energized along with the Indoor blower. If the demand is not met, W3 is energized incase of staged heating. Heat-Cool select to COOL. Continuoue 3. Adjust thermostat setting to below room temperature. 4. Turn electric power ON. During power application check the following: a. b. c. d. Contactor - Contacts closing Compressor - ON Condenser fan motor - ON Circulating air blower - ON (after delay) Low/High Contactor contacts opening. Compressor - OFF Condenser fan motor - OFF Circulating blower - OFF (after delay) Cooling Operation Scroll of Operation (PAM324-42) (1)On a call for cooling (Y) The indoor fan energizes immediately whereas the contactor energizes after a 5 minute time delay (in case of an initial start up) starting the compressor and the outdoor fan motor. (2)When the cooling eetpoint has been satisfied When the cooling demand is met, (Y) de-energizes, off the compressor, indoor fan and the outdoor fan. Cooling Operation Preesure Controls 10. Operation 6.Turn electric power OFF 9. Sequence With the continuous Indoor fan option selected on the thermostat, G is continuously energized. Incase of 024 - 042 units, the selected airflow setting is provided. In the case of 048 and 054 units, the system runs low stage (Y1) airflow for continuous fan operation. This unit is equipped with extra low and high pressure ports located inside the unit panel where the external high and low pressure ports are installed. This allows for installation of high and low pressure controls or low ambient controls. 5.Switch the thermostat to OFF, check the following: a. b. c. d. Fan Recycle Delay Timer The defrost board isequipped with a recycle delay timer which will delay the start of the compressor for 5 minutes in the event of a power interruption. This sequences power throughout the system and prevents possible reverse rotation of the scroll compressor. The output of the timer controls the compressor contactor via a normally open contact of K3 (T2). The timer starts the delay cycle when the compressor is turned off by removal of "Y." If application of "Y" occurs before the timer has expired, the compressor contactor wil! not be energized until the timer has expired. shutting (PAM348-54) (1)On a call for cooling These units utilize a 2 stage indoor thermostat. With a first stage call for cooling (Y1), the indoor fan (low stage) energizes immediately whereas the contactor energizes after a 5 minute time delay (incase of an initial start up) starting the compressor (low stage) and the outdoor fan motor. If the low stage operation cannot satisfy the cooling demand, the second stage cooling (Y2) energizes switching the compressor into high stage cooling through energizing an internal solenoid valve inside the scroll compressor and switching the indoor fan into high stage. (2)When the cooling setpoint has been satisfied When second stage cooling is satisfied, Y2 de-energizes switching the compressor and the indoor fan into low stage cooling. When the low stage cooling demand is met, Y1 de-energizes shutting off the compressor, indoor fan and the outdoor fan. REDUCED EQUIPMENT LIFE HAZARD Failure to follow this caution may result in premature component failure. Do NOT operate unit on cooling when the outdoor temperature is below 45°F or PAM324 and 40°F for PAM330-54. This is necessary to prevent possible damage to the compressor. Pressure Switch Loss of Charge Pressure Switch: Units are equipped with a low pressure switch on the liquid line (high side) which has been installed to prevent system damage due to a loss of charge. The switch will open and de-energize the contactor if the high side pressure drops below the set point of the switch. High Pressure Switch: The PAM348-54 are equipped with a high pressure switch to protect the compressor. 12 42601 1101 oo
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 12 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Fri Apr 20 15:33:43 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools