ICU Medical 20791 Hospira MedNet 802.11a/b/g Wireless Upgrade Module User Manual 430 11541 001

Hospira, Inc. Hospira MedNet 802.11a/b/g Wireless Upgrade Module 430 11541 001

Contents

User Manual

Download: ICU Medical 20791 Hospira MedNet 802.11a/b/g Wireless Upgrade Module User Manual 430 11541 001
Mirror Download [FCC.gov]ICU Medical 20791 Hospira MedNet 802.11a/b/g Wireless Upgrade Module User Manual 430 11541 001
Document ID751382
Application IDY2rw+GCaDTa4J1WTT/ezbw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize27.94kB (349246 bits)
Date Submitted2007-01-26 00:00:00
Date Available2007-01-26 00:00:00
Creation Date2007-01-18 15:32:45
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2007-01-25 18:08:54
Document Title430-11541-001.book
Document CreatorFrameMaker 7.2
Document Author: 10135554

Hospira MedNet 802.11 a/b/g Wireless
Upgrade Module
Connectivity Engine (CE)
Configuration Guide
Includes
*Hospira MedNet® Plug ‘n Play Module (List 20677 & 20791-04-77)
For Use with Plum A+ Infusers (Lists 11971, 12391, 20679 & 20792-04)
*Hospira MedNet® Software (List 16033-04)
430-11541-001
©
Hospira, Inc.
This document and the subject matter disclosed herein are proprietary information.
Hospira retains all the exclusive rights of dissemination, reproduction, manufacture, and sale.
Any party using this document accepts it in confidence, and agrees not to duplicate it in whole
or in part nor disclose it to others without the written consent of Hospira.
430-11541-001
CE Configuration Guide
Change History
Part Number
Description of Change
430-11541-001
(Rev. 01/07)
Original issue
CE Configuration Guide
430-11541-001
CHANGE HISTORY
This page intentionally left blank.
430-11541-001
ii
CE Configuration Guide
Contents
INTRODUCTION TO THE MEDNET WIRELESS MODULE - - - - - - - - - - - - FCC INFORMATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - US FCC (FEDERAL COMMUNICATIONS COMMISSION) STATEMENT - - - - - - FCC INTERFERENCE STATEMENT - - - - - - - - - - - - - - - - - - - - - - RADIO FREQUENCY EXPOSURE STATEMENT - - - - - - - - - - - - - - - - - GUIDANCE ON EMC COMPATIBILITY - - - - - - - - - - - - - - - - - - - - - INSTALLING THE HOSPIRA MEDNET® PLUG ’N PLAY MODULE (LIST 20677-04)
To Replace the Module, proceed as follows: - - - - - - - - - - - - CONFIGURATION GUIDE - - - - - - - - - - - - - - - - - - - - - - - - - - - - GENERAL NOTES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SCOPE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ASSUMPTIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - INTRODUCTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SCREENS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - STATUS PROPERTIES SCREEN - - - - - - - - - - - - - - - - - - - - - - - - ETHERNET PROPERTIES - - - - - - - - - - - - - - - - - - - - - - - - - - - WIRELESS PROPERTIES - WIRELESS ENABLED - - - - - - - - - - - - - - - - WIRELESS ENABLED- DHCP ENABLED - - - - - - - - - - - - - - - - - - - SECURITY - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - WEP - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - WPA PERSONAL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - WPA ENTERPRISE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - WPA ENTERPRISE - AUTHENTICATION TYPE - - - - - - - - - - - - - - - - - CERTIFICATES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HMSS (HOSPIRA MEDNET® SERVER SUITE) - - - - - - - - - - - - - - - - - SERVICE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ADMINISTRATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - FINISH CONFIGURATION - - - - - - - - - - - - - - - - - - - - - - - - - - WIRELESS LAN DEVICE SPECIFICATIONS - - - - - - - - - - - - - - - - - - - -
CE Configuration Guide
- 1
- 1
- 1
- 1
- 1
- 2
- 3
- 3
- 4
- 4
- 4
- 4
- 4
- 5
- 5
- 6
- 6
- 8
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 16
- 17
- 17
- 18
430-11541-001
Introduction to the MedNet Wireless Module
The Hospira MedNet 802.11 a/b/g Wireless Upgrade Module is designed as an upgrade
module for Hospira Plum A+ Infusion Systems (Lists 20792, 20679, 12391 & 11791). The
host units are mobile infusion devices designed to be employed in the medical care environment. The wireless functionality afforded to the host units from the upgrade module
include the ability to download drug library information for simultaneously operating
hosts without requiring a physical connection and the time spent visiting the rooms they
occupy.
FCC Information
US FCC (Federal Communications Commission)
Statement
• This device complies with part 15C, 15E of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause interference, and (2)
This device must accept any interference, including that may cause undesired
operation of these devices.
FCC Interference Statement
• This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15C, 15E of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency energy.
If not installed and used in accordance with the instructions, it may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try and correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the distance between the equipment and the receiver.
- Connect the equipment to an outlet on a circuit different from that to which the
receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
• Changes or modifications not expressly approved by Hospira could void the user's
authority to operate the equipment.
Radio Frequency Exposure Statement
• The Wireless LAN radio device in the Connectivity Engine peripheral board with this
infusion device has been evaluated and found compliant to the requirements of the
following Radio Frequency exposure standards:
- Federal Communications Commission, OET Bulletin 65 (Edition 97-01),
Supplement C (Edition 01-01), Evaluating Compliance with FCC Guidelines for
Human Exposure to Radio frequency Electromagnetic Fields, July 2001.
CE Configuration Guide
430-11541-001
-
Industry Canada, Evaluation Procedure for Mobile and Portable Radio
Transmitters with respect to Health Canada's Safety Code 6 for Exposure of
Humans to Radio Frequency Fields, Radio Standards Specification RSS-102
Issue 1 (Provisional): September 1999.
• The radiated output power of this Wireless LAN device is far below the FCC radio
frequency exposure limits. The Wireless LAN device has been evaluated with zero
inches separation of human body from the antenna and found to be compliant with
FCC RF exposure limits.
Guidance on EMC Compatibility
• There is a shared responsibility between manufacturers, customers and users to
ensure that Medical Equipment and Systems are designed and operated as intended.
Medical electrical equipment needs special precautions regarding electromagnetic
compatibility and needs to be installed and used according to the electromagnetic
compatibility information provided in this manual.
• The device is suitable for use in all establishments, including domestic
establishments. If extended operation during power mains interruption is needed, use
battery power.
• Always manage the electromagnetic environment.
• The guidance included in this manual provides information needed to:
- Determine the device’s suitability for use in the intended environment.
- Manage the electromagnetic environment to permit the device to perform as
intended without disturbing other equipment.
• Separate the device from all other electronic equipment. If the device must be used
near other electrical equipment, monitor the equipment to ensure there is no
electromagnetic interference.
• Devices should not be used adjacent to or stacked with other equipment. If the device
must be used adjacent to or stacked with other equipment, monitor the devices to
verify normal operation.
• USE ONLY components specifically labeled for use with the Plum A+ Infusion
System to help ensure the device operates as intended.
• If you suspect external RF sources or other equipment are influencing device
operation, contact the biomedical engineering department for additional guidelines
concerning electromagnetic immunity.
• Contact the biomedical engineering department for additional information in the
technical service manual concerning operating devices near RF sources.
• This device has been tested with the Hospira Plum A+ Infusion System and found to
comply with the International Standard IEC 60601-1-2 Edition 2.1 Electromagnetic
Compatibility (EMC) of Medical Electrical Equipment.
430-11541-001
CE Configuration Guide
Installing the Hospira MedNet® Plug ’n Play
Module (List 20677-04)
Note: For use with Hospira Plum A+ Infusers with software version 10.3 and
higher.
Note:
The recommended tool for this procedure is a No. 2 Phillips screwdriver.
CAUTION: CAUTION: Use proper ESD grounding techniques when handling
components. Wear an antistatic wrist strap and use an ESD-protected workstation.
Store the PWA in an antistatic bag before placing it on any surface.
To Replace the Module, proceed as follows:
1. Press [ON/OFF] to power the infuser
OFF.
2. Disconnect the infuser from AC
power.
CAUTION: Infuser must be
powered off for at least 2 minutes
prior to removing the module.
3. Carefully place the infuser face down.
4. Using a No. 2 Phillips screwdriver,
remove the two screws from the
module (one in the upper left corner
and one in the lower left corner). Refer
to Figure 1.
Figure 1. Remove Screws
5. Carefully pull the module away from the infuser.
Note: Note: When removing the module, note the placement guides the peripheral
PWA rests between.
6. Install the replacement module in the
exact reverse order of removal using
the screws and lock washers included
with the replacement module. Refer
to Figure 2.
Note: Note: Verify the module is
placed properly between the guides
and fits correctly into the CPU PWA.
7. Connect the infuser to AC power.
8. To
verify
successful
module
replacement, power ON the infuser
and let the system perform its
self-tests. The screen will display an
E453 Malfunction.
Figure 2. Insert Module
9. Power the infuser OFF, and then ON
again.
10. If upgrading from version 12.x, The infuser is ready for operation.
11. If upgrading from version 10.x or 11.x:
a) Enter the serial number.
b) Power the infuser OFF, and then ON again. The infuser is ready for operation.
CE Configuration Guide
430-11541-001
Configuration Guide
General Notes
This document is a general guide for using the CE Configuration Tool.
Note: Please refer to the Installation and Configuration Guide and the User Guide for
proper use, warnings and cautions associated with the Hospira MedNet®
Software.
The application software is a web page server that resides in the CE. From the server on
which HMSS resides, access the infuser Status screen by entering:
https://infuserIPaddress:8443
Note: The default IP address for the infuser is 192.168.0.100 and the Netmask is
255.255.0.0
Scope
The scope of this document is to outline the functionality of the CE Configuration web
page that displays in the Microsoft® Internet Explorer Version 6 browser window.
This document does not address the functionality of the browser in which the web page
displays, nor does it address specific topics related to Ethernet, TCP/IP, Internet, or wireless security and authentication.
Assumptions
The user has a working knowledge of the following terms, features, concepts and facilities:
• Operation of Microsoft® Windows
• Operation of Microsoft® Internet Explorer Version 6 browser
• Basic understanding of Ethernet, IP addresses, MAC Addresses,
Subnet Masks, Gateways, DHCP, DNS, Domains
• Basic understanding of HTTP including Basic Authentication, SSL,
user IDs, and passwords
• Basic understanding of other Ethernet protocols including Telnet, FTP,
TCP, UDP
• URL formats including protocol and port specifications
• Security configuration including WEP, SSID, Access Points,
Authentication Types
Introduction
The following is information provided for general use:
• A navigation menu is displayed on the left side of the page
• The Tab key has no effect on the navigation menu items (i.e., it will not
select or highlight them)
• Unless otherwise specified, “alphanumeric characters” include all
upper- and lower-case letters and numbers
430-11541-001
CE Configuration Guide
•
In this document, “character” refers to all upper- and lower-case letters,
numbers, punctuation marks, symbols (i.e., 8-bit character codes
between 32 and 126 inclusive)
Screens
Screen
Function
Status
Current status of the CE
Ethernet Properties
Ethernet properties settings
Wireless Properties
Wireless properties settings
Wireless Security
Properties
Wireless security properties settings
Certificates
Wireless certificates properties settings
HMSS Properties
Hospira MedNet® Server Suite properties
Service Properties
Service settings
Administration
Administration settings
Finish Configuration
Confirmation and results
Configuration Results
Configuration results
Note: Hovering your mouse over such fields as Identity or Password will activate a
tooltip with admissible characters.
Status Properties Screen
Field/Button
Device Status
Content/Action
Device Name: value entered on HMSS Screen
Device Type: Device Type connected to
CE App Version: CE version string
CE System Version: CE system string
Ethernet
If Ethernet interface is active: IP Address, Subnet Mask, MAC
Address
If WLAN interface is active: (Interface is down)
Wireless LAN
WLAN Interface is Active: IP Address, Subnet Mask, MAC
Address, WEP Enabled, Access Point, SSID, Current Channel,
Signal Quality Level, Noise Level, Frequency Band, Transmit
Power, Power Save
WLAN Interface is not active: (Interface is down)
HMSS
HMSS Host/ URL or IP Address
Status: Connected, "Not responding", "(Status is not available)”
Pump
Status: Connected, "Not responding", "(Status is not available)"
Refresh
Updates all Status sections with current values
Next
Displays the Ethernet Properties screen
CE Configuration Guide
430-11541-001
Ethernet Properties
Field/Button
MAC Address
Content/Action
(Not configurable, READ ONLY)
Device MAC address
Default: factory default MAC address
Use DHCP
Unchecked: Displays IP Address, Subnet Mask, Gateway fields,
DNS1, DNS2, and Domain
Checked: Hides IP Address, Subnet Mask, Gateway fields,
DNS1, DNS2, and Domain
Default: unchecked
IP Address (available when
DHCP is unchecked)
IP Address of the device
Subnet Mask (available
when DHCP is unchecked)
Subnet Mask of the device
Gateway (available when
DHCP is unchecked)
Gateway Host Name or IP Address
DNS1 (available when
DHCP is unchecked)
Primary DNS IP Address
DNS2 (available when
DHCP is unchecked) Optional field
Secondary DNS IP Address
Domain (available when
DHCP is unchecked)
Domain name
Alphanumeric 1-255 characters and the following 3 characters:
Period (.), hyphen (-), underscore (_)
Default: 192.168.0.100
Default: 255.255.0.0
Default: Blank
Default: Blank
Default: Blank
Default: Blank
Previous
Displays the previous screen
Reset
Allows you to reconfigure the current page only
Finish
Displays the Finish Configuration screen and should only be
clicked when all the variables have been entered
Next
Displays the following screen
Wireless Properties - Wireless Enabled
Field/Button
Wireless Enabled
Content/Action
Checked: Enables Wireless Capability and displays the rest of the
fields and checkboxes on the screen
Unchecked: Disables Wireless Capability and hides the rest of
the fields and checkboxes on the screen
Default: Checked
430-11541-001
CE Configuration Guide
Field/Button
Use DHCP
Content/Action
Unchecked: Displays IP Address, Subnet Mask, Gateway fields,
DNS1, DNS2 and Domain
Checked: Hides IP Address, Subnet Mask, Gateway fields,
DNS1, DNS2 and Domain
Default: unchecked
IP Address (DHCP is
unchecked)
IP Address of the device
Subnet Mask (DHCP is
unchecked)
Subnet Mask of the device
Gateway (DHCP is
unchecked)
Gateway Host Name or IP Address
DNS1 (DHCP is
unchecked)- Optional field
Primary DNS IP Address
DNS2 (DHCP is
unchecked)- Optional field
Secondary DNS IP Address
Domain (DHCP is
unchecked)
Domain name
Alphanumeric 1-255 characters and the following 3 characters:
Period (.), hyphen (-), underscore (_)
Default: 192.168.0.100
Default: 255.255.0.0
Default: Blank
Default: Blank
Default: Blank
Default: Blank
SSID
Alphanumeric, space, and the following characters:
~!@#%^&*()_{}|:<>`-=;',./
2-32characters
Additionally, the following three characters cannot be the first
character: ! # ;
Frequency
802.11b (2.4GHz)
802.11b/802.11g (2.4GHz)
802.11g (2.4GHz)
802.11a (5GHz)
Auto
Default: Auto (The "Auto" option is comprised of 802.11a, 802.11b
and 802.11g.)
Note: Selecting Auto prompts a sequential search and may be slower
802.11B Preamble
Long
Short
Default: Long
Power Save
Continuous Access Mode
Maximum Power Save
Default: Maximum Power Save
CE Configuration Guide
430-11541-001
Field/Button
Transmit Power
Content/Action
100% (maximum), 75%, 50%, 25%, 12%, 6%, 4%, 2%, 1%
(lowest)
Default: 100%
Note: 100%=50 mW; 50%=25 mW; 25%=12.5 mW; Minimum=1 mW
Country
List of countries
Default: United States
Note: Selecting a country from the drop-down list, adjusts automatically
the frequency and channels.
Previous
Displays the previous screen
Reset
Allows you to reconfigure the current page only
Finish
Displays the Finish Configuration screen and should only be
clicked when all the variables have been entered
Next
Displays the following screen
Wireless Enabled- DHCP Enabled
Field/Button
Wireless Enabled
Content/Action
Checked: Enables Wireless Capability and displays the rest of the
fields and checkboxes on the screen
Unchecked: Disables Wireless Capability and hides the rest of
the fields and checkboxes on the screen
Default: Checked
Use DHCP
Unchecked: Displays IP Address, Subnet Mask, Gateway fields,
DNS1, DNS2 and Domain
Checked: Hides IP Address, Subnet Mask, Gateway fields,
DNS1, DNS2 and Domain
Default: unchecked
Renew Lease on Wireless
AP Association
Unchecked: Disables DHCP lease renewal on wireless AP
change
Checked: Enables DHCP lease renewal on wireless AP change
Default: unchecked
SSID
Alphanumeric, space, and the following characters:
~!@#%^&*()_{}|:<>`-=;',./
2-32 characters
Additionally, the following three characters cannot be the first
character: ! # ;
430-11541-001
CE Configuration Guide
Field/Button
Frequency
Content/Action
802.11b (2.4GHz)
802.11b/802.11g (2.4GHz)
802.11g (2.4GHz)
802.11a (5GHz)
Auto
Default: Auto (The "Auto" option is comprised of 802.11a, 802.11b
and 802.11g)
Note: Selecting Auto prompts a sequential search and may be slower.
Applies if the frequency does not include 802.11b
802.11B Preamble
Long
Short
Default: Long
Power Save
Continuous Access Mode
Maximum Power Save
Default: Maximum Power Save
Transmit Power
100% (maximum), 75%, 50%, 25%, 12%, 6%, 4%, 2%, 1%
(lowest)
Default: 100%
Note: 100%=50 mW; 50%=25 mW; 25%=12.5 mW; Minimum=1 mW
Country
List of countries
Default: United States
Note: Selecting a country from the drop-down list, adjusts automatically
the frequency and channels.
Previous
Displays the previous screen
Reset
Allows you to reconfigure the current page only
Finish
Displays the Finish Configuration screen and should only be
clicked when all the variables have been entered
Next
Displays the following screen
CE Configuration Guide
430-11541-001
Security
Important: Security settings, such as identify, password, etc. should conform
to your infrastructure.
Field/Button
Security
Content/Action
Disabled
WEP
WPA Personal
WPA Enterprise
When WEP is selected, displays Authentication Type, Key Length,
WEP Keys 0 - 3, and Default Key fields
When WPA Personal is selected, displays Shared Key field
When WPA Enterprise is selected, displays Authentication Type
and Validate Server Cert objects and fields
Default: Disabled
430-11541-001
10
CE Configuration Guide
WEP
Field/Button
Security
Content/Action
Disabled
WEP (Static only)
WPA Personal
WPA Enterprise
When WEP is selected, displays Authentication Type, Key Length,
WEP Keys 0 - 3, and Default Key fields
When WPA Personal is selected, displays Shared Key field
When WPA Enterprise is selected, displays Authentication Type
and Validate Server Cert objects and fields
Default: Disabled
Authentication Type (WEP
selected)
Open
Shared
Default: Open
Key Length
WEP 40 (40 + 24/10 hex digits)
WEP 104 (104 + 24/26 hex digits)
WEP Key 0
(Required field if this WEP
key number is selected in
the "Default Key" field)
10 or 26 hex digits
WEP Key 1
(Required field if this WEP
key number is selected in
the "Default Key" field)
10 or 26 hex digits
WEP Key 2
(Required field if this WEP
key number is selected in
the "Default Key" field)
10 or 26 hex digits
WEP Key 3
(Required field if this WEP
key number is selected in
the "Default Key" field)
10 or 26 hex digits
Default Key
0, 1, 2, 3
Previous
Displays the previous screen
Reset
Allows you to reconfigure the current page only
Finish
Displays the Finish Configuration screen and should only be
clicked when all the variables have been entered
Next
Displays the following screen
Default: Blank
Default: Blank
Default: Blank
Default: Blank
Note: If the information is entered incorrectly, an error message will pop-up indicating
what fields needs changing and display the parameters.
CE Configuration Guide
11
430-11541-001
WPA Personal
Field/Button
Security
Content/Action
Disabled
WEP
WPA Personal
WPA Enterprise
When WPA Personal is selected, displays Shared Key field
Default: Disabled
Encryption Protocol
WPA2-CCMP/AES (requires appropriate hardware for access
points)
WPA1-TKIP
Default: WPA2-CCMP/AES
Shared Key
64 (hex) character shared key value or an 8 - 63 ASCII character
pass-phrase
Note: An invalid entry will prompt an error message and display the field
requirements
Previous
Displays the previous screen
Reset
Allows you to reconfigure the current page only
Finish
Displays the Finish Configuration screen and should only be
clicked when all the variables have been entered
Next
Displays the following screen
430-11541-001
12
CE Configuration Guide
WPA Enterprise
Note: WPA Enterprise requires an authentication server. We support Free Radius and
Cisco ACS.
Field/Button
Security
Content/Action
Disabled
WEP
WPA Personal
WPA Enterprise
When WPA Enterprise is selected, displays Authentication Type
and Validate Server Cert objects and fields
Default: Disabled
Encryption Protocol
WPA2-CCMP/AES (requires appropriate hardware for access
points)
WPA1-TKIP
Default: WPA2-CCMP/AES
Authentication Type
(see table below for fields
available according to
settings)
EAP-TLS (Default setting)
EAP-TTLS (FreeRadius only)
EAP-PEAP
EAP-FAST (Cisco ACS only)
Previous
Displays the previous screen
Reset
Allows you to reconfigure the current page only
Finish
Displays the Finish Configuration screen and should only be
clicked when all the variables have been entered
Next
Displays the following screen
Note: No format checking is performed at the time a file is uploaded.
CE Configuration Guide
13
430-11541-001
WPA Enterprise - Authentication Type
Authentication Type:
EAP-TLS (Default)
Field/Content
Identity
Validate Server Cert
Note: Placing a checkmark in the box next to Validate Server Cert:
enables the server certificate validation. If checked, a Client Certificate
and an appropriate CA Certificate should be uploaded on the Certificates
page
EAP-TTLS
Protocol:
•
•
•
•
•
•
EAP-MSCHAPv2
EAP-MD5
PAP
CHAP
MSCHAP
MSCHAPv2
Identity
Password
Confirm Password
Anonymous identity (Optional)
Validate Server Cert (Optional)
Note: Placing a checkmark in the box next to Validate Server Cert:
enables the server certificate validation. If checked, an appropriate CA
Certificate should be uploaded on the Certificates page
EAP-PEAP
Peap Inner Protocol:
• EAP-MSCHAPv2
• EAP-MD5
Identity
Password
Confirm Password
Anonymous identity (Optional)
Validate Server Cert (Optional)
Note: Placing a checkmark in the box next to Validate Server Cert:
enables the server certificate validation. If checked, an appropriate CA
Certificate should be uploaded on the Certificates page
EAP-FAST
Identity
Password
Confirm Password
Anonymous identity (Optional)
PAC File (Selecting Upload accesses the pop-up Browse
feature)
Important: Verify the ACS server’s system configuration has the
AP EAP request timeout set at 180 and the AP Activity
Timeout “unknown (non-cisco)” default is set at 220
(seconds)
The software shall support the following file type for WPA Authentication:
• FAST PAC File - FAST Protected Access Credential (PAC) file
430-11541-001
14
CE Configuration Guide
Certificates
This category is optional and will depend upon your network configuration.
Field/Button
Client Certificate
Content/Action
Default Hospira Certificate
User Specified Certificate
Default: Hospira Certificate
Client Certificate (User
Specified Certificate
selected)
Private Key File (upload/browse feature)
Password
Confirm Password
Certificate File (upload/browse feature)
Note: A “Success” message appears once the file is loaded and the file
information displays. If the transfer fails, an error message displays
CA Certificates
Active Certificates
Add Certificate (upload/browse feature)
Note: The software shall allow up to three CA Certificates to be active at
one time
Previous
Displays the previous screen
Reset
Allows you to reconfigure the current page only
Finish
Displays the Finish Configuration screen and should only be
clicked when all the variables have been entered
Next
Displays the following screen
The software shall support the following file types for WPA authentication:
• CA Certificate - PEM, DER
• Client Certificate - PEM, DER
• Private Key File - PEM, DER, PFX
CE Configuration Guide
15
430-11541-001
HMSS (Hospira MedNet® Server Suite)
Field/Button
HMSS HostIP Address
Content/Action
Server IP address or hostname
Format: alphanumeric and the following (3) characters: Period (.),
hyphen (-), underscore (_). The first character must be an
alpha-character and the last character may not be a hyphen (-)
character. A valid IP address is of the form "xxx.xxx.xxx.xxx"
where xxx is a number between 0 and 255.
HMSS SSL Enabled
Checked: Enables SSL mode during HMSS communications
Unchecked: Disables SSL mode during HMSS communications
Default: unchecked
Important: The appropriate port needs to be opened for outbound
traffic. Port 8443 or 8080 for device to HMSS and Port
80 or 443 for HMSS to device
Device Name
Device unique ID
1-255 characters or less
Note: We recommend using 15 characters or less. Using more than 15
characters may affect HMSS report layouts
Default: device00 (must be renamed - cannot be saved)
Device Type (READ ONLY)
Hospira Plum A+ or
Hospira Plum A+(CE) or
Hospira PCA or
Hospira Symbiq
Previous
Displays the previous screen
Reset
Allows you to reconfigure the current page only
Finish
Displays the Finish Configuration screen and should only be
clicked when all the variables have been entered
Next
Displays the following screen
Service
Telnet and FTP are enabled by default in order to generate the configuration.
Note: We recommend turning off both Telnet and FTP before putting the pump into
production and disabling HTTP access to the device (Port 8008).
Field/Button
Telnet Enabled
Content/Action
Checked: The CE Telnet service on port 23 is enabled
Unchecked: The CE Telnet service is disabled
FTP Enabled
Checked: The CE FTP service on port 21 is enabled
Unchecked: The CE FTP service is disabled
Non-Secure Configuration
Access (HTTP) Enabled
Checked: The non-secure HTTP access to the web configuration
pages is enabled on port 8008
Unchecked: HTTP access to the web is disabled
430-11541-001
16
CE Configuration Guide
Field/Button
Content/Action
Previous
Displays the previous screen
Reset
Allows you to reconfigure the current page only
Finish
Displays the Finish Configuration screen and should only be
clicked when all the variables have been entered
Next
Displays the following screen
Note: Web configuration access to the device using HTTPs (SSL) is always enabled.
Administration
Field/Button
Content/Action
Web User
Web log in username. Format: ASCII, 1-31 characters. Colon (:) is
not allowed
Default: admin
Web Password
Web password. Format: ASCII, 1-20 characters
Default: admin
Confirm Password
Confirms the password entered displaying as a dot for each
character
Note: An error message displays if the confirmed password does not
match the web password
Previous
Displays the previous screen
Reset
Allows you to reconfigure the current page only
Finish
Displays the Finish Configuration screen and should only be
clicked when all the variables have been entered
Next
Displays the following screen
Finish Configuration
Note: You may want to verify some or all of the previous screens to ensure the
information is entered correctly. It may take up to 5 minutes to activate the
changes.
Field/Button
Content/Action
Previous
Displays the previous screen
Finish
Commits the configuration changes to the device
The Configuration Successful screen displays. If a configuration error occurred, you will
be prompted to use the menu to return to a page of your choice.
Close the browser and remove the Ethernet cable is you wish to test the infuser on wireless
mode. The computer will reboot in a few seconds.
CE Configuration Guide
17
430-11541-001
Wireless Lan Device Specifications
430-11541-001
Standards:
IEEE802.11a/b/g
Transmit Power:
802.11 b/g: 17.6 dBm
802.11 a: 19 dBm
Antenna:
Integrated surface mount antenna
18
CE Configuration Guide
For technical assistance, product return authorization, and to order parts, accessories, or manuals within
the United States, contact Hospira Technical Support Operations.
1-800-241-4002
For additional services and technical training courses, visit the website at www.hospira.com.
For technical assistance and services outside the United States, contact the local Hospira sales office.
CAUTION: Federal (USA) law restricts this infuser to sale by or on the order of a physician or other
licensed practitioner.
Plum A+, LifeCare PCA and Symbiq are registered trademarks of Hospira, Inc. Microsoft and Windows are
not trademarks or registered trademarks of Hospira, Inc. The Symbiq infusion system uses components and
technologies protected by U.S. Patent Numbers USD500326; USD515205; US5989222; US519175;
US5462256; US5586868; US5816779; US5681285. Other patents pending.
This document and the subject matter disclosed herein are proprietary information. Hospira retains all the
exclusive rights of dissemination, reproduction, manufacture, and sale. Any party using this document
accepts it in confidence, and agrees not to duplicate it in whole or in part nor disclose it to others without
the written consent of Hospira.
FC
Complies with limits for Class B digital device established
by FCC Rules, Part 15
Attention, consult accompanying documents.
DUT INFORMATION
FCC ID: STJ-20791
IC No: 5627A-20791
Certifications: FCC Part 15.247, 15.407
IC RSS-210, RSS-102
Device Name: Hospira MedNet 802.11 a/b/g Wireless Upgrade Module
Note: For use with Hospira PlumA+ Infusion system
Model Nos Covered: 20791-04-77, 20677-04-77
Note: Above two device model numbers are based on the same assembly. Device Model 20791-04-XX is
meant for use in models 20792-04-XX and 20679-04-XX of PlumA+ Infusion System and device model
20677-04-XX is meant for use in models 12391-04-XX and 11971-04-XX Plum A+ Infusion Systems.
© Hospira, Inc.
430-11541-001-END
CE Configuration Guide

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
Page Count                      : 24
Page Mode                       : UseOutlines
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:04ee2da0-2062-450e-ba13-9cee34ecc513
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Creator Tool                    : FrameMaker 7.2
Modify Date                     : 2007:01:25 18:08:54-08:00
Create Date                     : 2007:01:18 15:32:45Z
Metadata Date                   : 2007:01:25 18:08:54-08:00
Document ID                     : uuid:9604a8b6-2623-4c0a-9da7-5c4fd891be31
Format                          : application/pdf
Title                           : 430-11541-001.book
Creator                         : 10135554
Author                          : 10135554
EXIF Metadata provided by EXIF.tools
FCC ID Filing: STJ-20791

Navigation menu