ICU Medical 20791 Hospira MedNet 802.11a/b/g Wireless Upgrade Module User Manual 430 11541 001
Hospira, Inc. Hospira MedNet 802.11a/b/g Wireless Upgrade Module 430 11541 001
Contents
- 1. User manual
- 2. User Manual
User Manual
Hospira MedNet 802.11 a/b/g Wireless Upgrade Module Connectivity Engine (CE) Configuration Guide Includes *Hospira MedNet® Plug ‘n Play Module (List 20677 & 20791-04-77) For Use with Plum A+ Infusers (Lists 11971, 12391, 20679 & 20792-04) *Hospira MedNet® Software (List 16033-04) 430-11541-001 © Hospira, Inc. This document and the subject matter disclosed herein are proprietary information. Hospira retains all the exclusive rights of dissemination, reproduction, manufacture, and sale. Any party using this document accepts it in confidence, and agrees not to duplicate it in whole or in part nor disclose it to others without the written consent of Hospira. 430-11541-001 CE Configuration Guide Change History Part Number Description of Change 430-11541-001 (Rev. 01/07) Original issue CE Configuration Guide 430-11541-001 CHANGE HISTORY This page intentionally left blank. 430-11541-001 ii CE Configuration Guide Contents INTRODUCTION TO THE MEDNET WIRELESS MODULE - - - - - - - - - - - - FCC INFORMATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - US FCC (FEDERAL COMMUNICATIONS COMMISSION) STATEMENT - - - - - - FCC INTERFERENCE STATEMENT - - - - - - - - - - - - - - - - - - - - - - RADIO FREQUENCY EXPOSURE STATEMENT - - - - - - - - - - - - - - - - - GUIDANCE ON EMC COMPATIBILITY - - - - - - - - - - - - - - - - - - - - - INSTALLING THE HOSPIRA MEDNET® PLUG ’N PLAY MODULE (LIST 20677-04) To Replace the Module, proceed as follows: - - - - - - - - - - - - CONFIGURATION GUIDE - - - - - - - - - - - - - - - - - - - - - - - - - - - - GENERAL NOTES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SCOPE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ASSUMPTIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - INTRODUCTION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SCREENS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - STATUS PROPERTIES SCREEN - - - - - - - - - - - - - - - - - - - - - - - - ETHERNET PROPERTIES - - - - - - - - - - - - - - - - - - - - - - - - - - - WIRELESS PROPERTIES - WIRELESS ENABLED - - - - - - - - - - - - - - - - WIRELESS ENABLED- DHCP ENABLED - - - - - - - - - - - - - - - - - - - SECURITY - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - WEP - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - WPA PERSONAL - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - WPA ENTERPRISE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - WPA ENTERPRISE - AUTHENTICATION TYPE - - - - - - - - - - - - - - - - - CERTIFICATES - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - HMSS (HOSPIRA MEDNET® SERVER SUITE) - - - - - - - - - - - - - - - - - SERVICE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ADMINISTRATION - - - - - - - - - - - - - - - - - - - - - - - - - - - - - FINISH CONFIGURATION - - - - - - - - - - - - - - - - - - - - - - - - - - WIRELESS LAN DEVICE SPECIFICATIONS - - - - - - - - - - - - - - - - - - - - CE Configuration Guide - 1 - 1 - 1 - 1 - 1 - 2 - 3 - 3 - 4 - 4 - 4 - 4 - 4 - 5 - 5 - 6 - 6 - 8 - 10 - 11 - 12 - 13 - 14 - 15 - 16 - 16 - 17 - 17 - 18 430-11541-001 Introduction to the MedNet Wireless Module The Hospira MedNet 802.11 a/b/g Wireless Upgrade Module is designed as an upgrade module for Hospira Plum A+ Infusion Systems (Lists 20792, 20679, 12391 & 11791). The host units are mobile infusion devices designed to be employed in the medical care environment. The wireless functionality afforded to the host units from the upgrade module include the ability to download drug library information for simultaneously operating hosts without requiring a physical connection and the time spent visiting the rooms they occupy. FCC Information US FCC (Federal Communications Commission) Statement • This device complies with part 15C, 15E of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including that may cause undesired operation of these devices. FCC Interference Statement • This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15C, 15E of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the distance between the equipment and the receiver. - Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. • Changes or modifications not expressly approved by Hospira could void the user's authority to operate the equipment. Radio Frequency Exposure Statement • The Wireless LAN radio device in the Connectivity Engine peripheral board with this infusion device has been evaluated and found compliant to the requirements of the following Radio Frequency exposure standards: - Federal Communications Commission, OET Bulletin 65 (Edition 97-01), Supplement C (Edition 01-01), Evaluating Compliance with FCC Guidelines for Human Exposure to Radio frequency Electromagnetic Fields, July 2001. CE Configuration Guide 430-11541-001 - Industry Canada, Evaluation Procedure for Mobile and Portable Radio Transmitters with respect to Health Canada's Safety Code 6 for Exposure of Humans to Radio Frequency Fields, Radio Standards Specification RSS-102 Issue 1 (Provisional): September 1999. • The radiated output power of this Wireless LAN device is far below the FCC radio frequency exposure limits. The Wireless LAN device has been evaluated with zero inches separation of human body from the antenna and found to be compliant with FCC RF exposure limits. Guidance on EMC Compatibility • There is a shared responsibility between manufacturers, customers and users to ensure that Medical Equipment and Systems are designed and operated as intended. Medical electrical equipment needs special precautions regarding electromagnetic compatibility and needs to be installed and used according to the electromagnetic compatibility information provided in this manual. • The device is suitable for use in all establishments, including domestic establishments. If extended operation during power mains interruption is needed, use battery power. • Always manage the electromagnetic environment. • The guidance included in this manual provides information needed to: - Determine the device’s suitability for use in the intended environment. - Manage the electromagnetic environment to permit the device to perform as intended without disturbing other equipment. • Separate the device from all other electronic equipment. If the device must be used near other electrical equipment, monitor the equipment to ensure there is no electromagnetic interference. • Devices should not be used adjacent to or stacked with other equipment. If the device must be used adjacent to or stacked with other equipment, monitor the devices to verify normal operation. • USE ONLY components specifically labeled for use with the Plum A+ Infusion System to help ensure the device operates as intended. • If you suspect external RF sources or other equipment are influencing device operation, contact the biomedical engineering department for additional guidelines concerning electromagnetic immunity. • Contact the biomedical engineering department for additional information in the technical service manual concerning operating devices near RF sources. • This device has been tested with the Hospira Plum A+ Infusion System and found to comply with the International Standard IEC 60601-1-2 Edition 2.1 Electromagnetic Compatibility (EMC) of Medical Electrical Equipment. 430-11541-001 CE Configuration Guide Installing the Hospira MedNet® Plug ’n Play Module (List 20677-04) Note: For use with Hospira Plum A+ Infusers with software version 10.3 and higher. Note: The recommended tool for this procedure is a No. 2 Phillips screwdriver. CAUTION: CAUTION: Use proper ESD grounding techniques when handling components. Wear an antistatic wrist strap and use an ESD-protected workstation. Store the PWA in an antistatic bag before placing it on any surface. To Replace the Module, proceed as follows: 1. Press [ON/OFF] to power the infuser OFF. 2. Disconnect the infuser from AC power. CAUTION: Infuser must be powered off for at least 2 minutes prior to removing the module. 3. Carefully place the infuser face down. 4. Using a No. 2 Phillips screwdriver, remove the two screws from the module (one in the upper left corner and one in the lower left corner). Refer to Figure 1. Figure 1. Remove Screws 5. Carefully pull the module away from the infuser. Note: Note: When removing the module, note the placement guides the peripheral PWA rests between. 6. Install the replacement module in the exact reverse order of removal using the screws and lock washers included with the replacement module. Refer to Figure 2. Note: Note: Verify the module is placed properly between the guides and fits correctly into the CPU PWA. 7. Connect the infuser to AC power. 8. To verify successful module replacement, power ON the infuser and let the system perform its self-tests. The screen will display an E453 Malfunction. Figure 2. Insert Module 9. Power the infuser OFF, and then ON again. 10. If upgrading from version 12.x, The infuser is ready for operation. 11. If upgrading from version 10.x or 11.x: a) Enter the serial number. b) Power the infuser OFF, and then ON again. The infuser is ready for operation. CE Configuration Guide 430-11541-001 Configuration Guide General Notes This document is a general guide for using the CE Configuration Tool. Note: Please refer to the Installation and Configuration Guide and the User Guide for proper use, warnings and cautions associated with the Hospira MedNet® Software. The application software is a web page server that resides in the CE. From the server on which HMSS resides, access the infuser Status screen by entering: https://infuserIPaddress:8443 Note: The default IP address for the infuser is 192.168.0.100 and the Netmask is 255.255.0.0 Scope The scope of this document is to outline the functionality of the CE Configuration web page that displays in the Microsoft® Internet Explorer Version 6 browser window. This document does not address the functionality of the browser in which the web page displays, nor does it address specific topics related to Ethernet, TCP/IP, Internet, or wireless security and authentication. Assumptions The user has a working knowledge of the following terms, features, concepts and facilities: • Operation of Microsoft® Windows • Operation of Microsoft® Internet Explorer Version 6 browser • Basic understanding of Ethernet, IP addresses, MAC Addresses, Subnet Masks, Gateways, DHCP, DNS, Domains • Basic understanding of HTTP including Basic Authentication, SSL, user IDs, and passwords • Basic understanding of other Ethernet protocols including Telnet, FTP, TCP, UDP • URL formats including protocol and port specifications • Security configuration including WEP, SSID, Access Points, Authentication Types Introduction The following is information provided for general use: • A navigation menu is displayed on the left side of the page • The Tab key has no effect on the navigation menu items (i.e., it will not select or highlight them) • Unless otherwise specified, “alphanumeric characters” include all upper- and lower-case letters and numbers 430-11541-001 CE Configuration Guide • In this document, “character” refers to all upper- and lower-case letters, numbers, punctuation marks, symbols (i.e., 8-bit character codes between 32 and 126 inclusive) Screens Screen Function Status Current status of the CE Ethernet Properties Ethernet properties settings Wireless Properties Wireless properties settings Wireless Security Properties Wireless security properties settings Certificates Wireless certificates properties settings HMSS Properties Hospira MedNet® Server Suite properties Service Properties Service settings Administration Administration settings Finish Configuration Confirmation and results Configuration Results Configuration results Note: Hovering your mouse over such fields as Identity or Password will activate a tooltip with admissible characters. Status Properties Screen Field/Button Device Status Content/Action Device Name: value entered on HMSS Screen Device Type: Device Type connected to CE App Version: CE version string CE System Version: CE system string Ethernet If Ethernet interface is active: IP Address, Subnet Mask, MAC Address If WLAN interface is active: (Interface is down) Wireless LAN WLAN Interface is Active: IP Address, Subnet Mask, MAC Address, WEP Enabled, Access Point, SSID, Current Channel, Signal Quality Level, Noise Level, Frequency Band, Transmit Power, Power Save WLAN Interface is not active: (Interface is down) HMSS HMSS Host/ URL or IP Address Status: Connected, "Not responding", "(Status is not available)” Pump Status: Connected, "Not responding", "(Status is not available)" Refresh Updates all Status sections with current values Next Displays the Ethernet Properties screen CE Configuration Guide 430-11541-001 Ethernet Properties Field/Button MAC Address Content/Action (Not configurable, READ ONLY) Device MAC address Default: factory default MAC address Use DHCP Unchecked: Displays IP Address, Subnet Mask, Gateway fields, DNS1, DNS2, and Domain Checked: Hides IP Address, Subnet Mask, Gateway fields, DNS1, DNS2, and Domain Default: unchecked IP Address (available when DHCP is unchecked) IP Address of the device Subnet Mask (available when DHCP is unchecked) Subnet Mask of the device Gateway (available when DHCP is unchecked) Gateway Host Name or IP Address DNS1 (available when DHCP is unchecked) Primary DNS IP Address DNS2 (available when DHCP is unchecked) Optional field Secondary DNS IP Address Domain (available when DHCP is unchecked) Domain name Alphanumeric 1-255 characters and the following 3 characters: Period (.), hyphen (-), underscore (_) Default: 192.168.0.100 Default: 255.255.0.0 Default: Blank Default: Blank Default: Blank Default: Blank Previous Displays the previous screen Reset Allows you to reconfigure the current page only Finish Displays the Finish Configuration screen and should only be clicked when all the variables have been entered Next Displays the following screen Wireless Properties - Wireless Enabled Field/Button Wireless Enabled Content/Action Checked: Enables Wireless Capability and displays the rest of the fields and checkboxes on the screen Unchecked: Disables Wireless Capability and hides the rest of the fields and checkboxes on the screen Default: Checked 430-11541-001 CE Configuration Guide Field/Button Use DHCP Content/Action Unchecked: Displays IP Address, Subnet Mask, Gateway fields, DNS1, DNS2 and Domain Checked: Hides IP Address, Subnet Mask, Gateway fields, DNS1, DNS2 and Domain Default: unchecked IP Address (DHCP is unchecked) IP Address of the device Subnet Mask (DHCP is unchecked) Subnet Mask of the device Gateway (DHCP is unchecked) Gateway Host Name or IP Address DNS1 (DHCP is unchecked)- Optional field Primary DNS IP Address DNS2 (DHCP is unchecked)- Optional field Secondary DNS IP Address Domain (DHCP is unchecked) Domain name Alphanumeric 1-255 characters and the following 3 characters: Period (.), hyphen (-), underscore (_) Default: 192.168.0.100 Default: 255.255.0.0 Default: Blank Default: Blank Default: Blank Default: Blank SSID Alphanumeric, space, and the following characters: ~!@#%^&*()_{}|:<>`-=;',./ 2-32characters Additionally, the following three characters cannot be the first character: ! # ; Frequency 802.11b (2.4GHz) 802.11b/802.11g (2.4GHz) 802.11g (2.4GHz) 802.11a (5GHz) Auto Default: Auto (The "Auto" option is comprised of 802.11a, 802.11b and 802.11g.) Note: Selecting Auto prompts a sequential search and may be slower 802.11B Preamble Long Short Default: Long Power Save Continuous Access Mode Maximum Power Save Default: Maximum Power Save CE Configuration Guide 430-11541-001 Field/Button Transmit Power Content/Action 100% (maximum), 75%, 50%, 25%, 12%, 6%, 4%, 2%, 1% (lowest) Default: 100% Note: 100%=50 mW; 50%=25 mW; 25%=12.5 mW; Minimum=1 mW Country List of countries Default: United States Note: Selecting a country from the drop-down list, adjusts automatically the frequency and channels. Previous Displays the previous screen Reset Allows you to reconfigure the current page only Finish Displays the Finish Configuration screen and should only be clicked when all the variables have been entered Next Displays the following screen Wireless Enabled- DHCP Enabled Field/Button Wireless Enabled Content/Action Checked: Enables Wireless Capability and displays the rest of the fields and checkboxes on the screen Unchecked: Disables Wireless Capability and hides the rest of the fields and checkboxes on the screen Default: Checked Use DHCP Unchecked: Displays IP Address, Subnet Mask, Gateway fields, DNS1, DNS2 and Domain Checked: Hides IP Address, Subnet Mask, Gateway fields, DNS1, DNS2 and Domain Default: unchecked Renew Lease on Wireless AP Association Unchecked: Disables DHCP lease renewal on wireless AP change Checked: Enables DHCP lease renewal on wireless AP change Default: unchecked SSID Alphanumeric, space, and the following characters: ~!@#%^&*()_{}|:<>`-=;',./ 2-32 characters Additionally, the following three characters cannot be the first character: ! # ; 430-11541-001 CE Configuration Guide Field/Button Frequency Content/Action 802.11b (2.4GHz) 802.11b/802.11g (2.4GHz) 802.11g (2.4GHz) 802.11a (5GHz) Auto Default: Auto (The "Auto" option is comprised of 802.11a, 802.11b and 802.11g) Note: Selecting Auto prompts a sequential search and may be slower. Applies if the frequency does not include 802.11b 802.11B Preamble Long Short Default: Long Power Save Continuous Access Mode Maximum Power Save Default: Maximum Power Save Transmit Power 100% (maximum), 75%, 50%, 25%, 12%, 6%, 4%, 2%, 1% (lowest) Default: 100% Note: 100%=50 mW; 50%=25 mW; 25%=12.5 mW; Minimum=1 mW Country List of countries Default: United States Note: Selecting a country from the drop-down list, adjusts automatically the frequency and channels. Previous Displays the previous screen Reset Allows you to reconfigure the current page only Finish Displays the Finish Configuration screen and should only be clicked when all the variables have been entered Next Displays the following screen CE Configuration Guide 430-11541-001 Security Important: Security settings, such as identify, password, etc. should conform to your infrastructure. Field/Button Security Content/Action Disabled WEP WPA Personal WPA Enterprise When WEP is selected, displays Authentication Type, Key Length, WEP Keys 0 - 3, and Default Key fields When WPA Personal is selected, displays Shared Key field When WPA Enterprise is selected, displays Authentication Type and Validate Server Cert objects and fields Default: Disabled 430-11541-001 10 CE Configuration Guide WEP Field/Button Security Content/Action Disabled WEP (Static only) WPA Personal WPA Enterprise When WEP is selected, displays Authentication Type, Key Length, WEP Keys 0 - 3, and Default Key fields When WPA Personal is selected, displays Shared Key field When WPA Enterprise is selected, displays Authentication Type and Validate Server Cert objects and fields Default: Disabled Authentication Type (WEP selected) Open Shared Default: Open Key Length WEP 40 (40 + 24/10 hex digits) WEP 104 (104 + 24/26 hex digits) WEP Key 0 (Required field if this WEP key number is selected in the "Default Key" field) 10 or 26 hex digits WEP Key 1 (Required field if this WEP key number is selected in the "Default Key" field) 10 or 26 hex digits WEP Key 2 (Required field if this WEP key number is selected in the "Default Key" field) 10 or 26 hex digits WEP Key 3 (Required field if this WEP key number is selected in the "Default Key" field) 10 or 26 hex digits Default Key 0, 1, 2, 3 Previous Displays the previous screen Reset Allows you to reconfigure the current page only Finish Displays the Finish Configuration screen and should only be clicked when all the variables have been entered Next Displays the following screen Default: Blank Default: Blank Default: Blank Default: Blank Note: If the information is entered incorrectly, an error message will pop-up indicating what fields needs changing and display the parameters. CE Configuration Guide 11 430-11541-001 WPA Personal Field/Button Security Content/Action Disabled WEP WPA Personal WPA Enterprise When WPA Personal is selected, displays Shared Key field Default: Disabled Encryption Protocol WPA2-CCMP/AES (requires appropriate hardware for access points) WPA1-TKIP Default: WPA2-CCMP/AES Shared Key 64 (hex) character shared key value or an 8 - 63 ASCII character pass-phrase Note: An invalid entry will prompt an error message and display the field requirements Previous Displays the previous screen Reset Allows you to reconfigure the current page only Finish Displays the Finish Configuration screen and should only be clicked when all the variables have been entered Next Displays the following screen 430-11541-001 12 CE Configuration Guide WPA Enterprise Note: WPA Enterprise requires an authentication server. We support Free Radius and Cisco ACS. Field/Button Security Content/Action Disabled WEP WPA Personal WPA Enterprise When WPA Enterprise is selected, displays Authentication Type and Validate Server Cert objects and fields Default: Disabled Encryption Protocol WPA2-CCMP/AES (requires appropriate hardware for access points) WPA1-TKIP Default: WPA2-CCMP/AES Authentication Type (see table below for fields available according to settings) EAP-TLS (Default setting) EAP-TTLS (FreeRadius only) EAP-PEAP EAP-FAST (Cisco ACS only) Previous Displays the previous screen Reset Allows you to reconfigure the current page only Finish Displays the Finish Configuration screen and should only be clicked when all the variables have been entered Next Displays the following screen Note: No format checking is performed at the time a file is uploaded. CE Configuration Guide 13 430-11541-001 WPA Enterprise - Authentication Type Authentication Type: EAP-TLS (Default) Field/Content Identity Validate Server Cert Note: Placing a checkmark in the box next to Validate Server Cert: enables the server certificate validation. If checked, a Client Certificate and an appropriate CA Certificate should be uploaded on the Certificates page EAP-TTLS Protocol: • • • • • • EAP-MSCHAPv2 EAP-MD5 PAP CHAP MSCHAP MSCHAPv2 Identity Password Confirm Password Anonymous identity (Optional) Validate Server Cert (Optional) Note: Placing a checkmark in the box next to Validate Server Cert: enables the server certificate validation. If checked, an appropriate CA Certificate should be uploaded on the Certificates page EAP-PEAP Peap Inner Protocol: • EAP-MSCHAPv2 • EAP-MD5 Identity Password Confirm Password Anonymous identity (Optional) Validate Server Cert (Optional) Note: Placing a checkmark in the box next to Validate Server Cert: enables the server certificate validation. If checked, an appropriate CA Certificate should be uploaded on the Certificates page EAP-FAST Identity Password Confirm Password Anonymous identity (Optional) PAC File (Selecting Upload accesses the pop-up Browse feature) Important: Verify the ACS server’s system configuration has the AP EAP request timeout set at 180 and the AP Activity Timeout “unknown (non-cisco)” default is set at 220 (seconds) The software shall support the following file type for WPA Authentication: • FAST PAC File - FAST Protected Access Credential (PAC) file 430-11541-001 14 CE Configuration Guide Certificates This category is optional and will depend upon your network configuration. Field/Button Client Certificate Content/Action Default Hospira Certificate User Specified Certificate Default: Hospira Certificate Client Certificate (User Specified Certificate selected) Private Key File (upload/browse feature) Password Confirm Password Certificate File (upload/browse feature) Note: A “Success” message appears once the file is loaded and the file information displays. If the transfer fails, an error message displays CA Certificates Active Certificates Add Certificate (upload/browse feature) Note: The software shall allow up to three CA Certificates to be active at one time Previous Displays the previous screen Reset Allows you to reconfigure the current page only Finish Displays the Finish Configuration screen and should only be clicked when all the variables have been entered Next Displays the following screen The software shall support the following file types for WPA authentication: • CA Certificate - PEM, DER • Client Certificate - PEM, DER • Private Key File - PEM, DER, PFX CE Configuration Guide 15 430-11541-001 HMSS (Hospira MedNet® Server Suite) Field/Button HMSS HostIP Address Content/Action Server IP address or hostname Format: alphanumeric and the following (3) characters: Period (.), hyphen (-), underscore (_). The first character must be an alpha-character and the last character may not be a hyphen (-) character. A valid IP address is of the form "xxx.xxx.xxx.xxx" where xxx is a number between 0 and 255. HMSS SSL Enabled Checked: Enables SSL mode during HMSS communications Unchecked: Disables SSL mode during HMSS communications Default: unchecked Important: The appropriate port needs to be opened for outbound traffic. Port 8443 or 8080 for device to HMSS and Port 80 or 443 for HMSS to device Device Name Device unique ID 1-255 characters or less Note: We recommend using 15 characters or less. Using more than 15 characters may affect HMSS report layouts Default: device00 (must be renamed - cannot be saved) Device Type (READ ONLY) Hospira Plum A+ or Hospira Plum A+(CE) or Hospira PCA or Hospira Symbiq Previous Displays the previous screen Reset Allows you to reconfigure the current page only Finish Displays the Finish Configuration screen and should only be clicked when all the variables have been entered Next Displays the following screen Service Telnet and FTP are enabled by default in order to generate the configuration. Note: We recommend turning off both Telnet and FTP before putting the pump into production and disabling HTTP access to the device (Port 8008). Field/Button Telnet Enabled Content/Action Checked: The CE Telnet service on port 23 is enabled Unchecked: The CE Telnet service is disabled FTP Enabled Checked: The CE FTP service on port 21 is enabled Unchecked: The CE FTP service is disabled Non-Secure Configuration Access (HTTP) Enabled Checked: The non-secure HTTP access to the web configuration pages is enabled on port 8008 Unchecked: HTTP access to the web is disabled 430-11541-001 16 CE Configuration Guide Field/Button Content/Action Previous Displays the previous screen Reset Allows you to reconfigure the current page only Finish Displays the Finish Configuration screen and should only be clicked when all the variables have been entered Next Displays the following screen Note: Web configuration access to the device using HTTPs (SSL) is always enabled. Administration Field/Button Content/Action Web User Web log in username. Format: ASCII, 1-31 characters. Colon (:) is not allowed Default: admin Web Password Web password. Format: ASCII, 1-20 characters Default: admin Confirm Password Confirms the password entered displaying as a dot for each character Note: An error message displays if the confirmed password does not match the web password Previous Displays the previous screen Reset Allows you to reconfigure the current page only Finish Displays the Finish Configuration screen and should only be clicked when all the variables have been entered Next Displays the following screen Finish Configuration Note: You may want to verify some or all of the previous screens to ensure the information is entered correctly. It may take up to 5 minutes to activate the changes. Field/Button Content/Action Previous Displays the previous screen Finish Commits the configuration changes to the device The Configuration Successful screen displays. If a configuration error occurred, you will be prompted to use the menu to return to a page of your choice. Close the browser and remove the Ethernet cable is you wish to test the infuser on wireless mode. The computer will reboot in a few seconds. CE Configuration Guide 17 430-11541-001 Wireless Lan Device Specifications 430-11541-001 Standards: IEEE802.11a/b/g Transmit Power: 802.11 b/g: 17.6 dBm 802.11 a: 19 dBm Antenna: Integrated surface mount antenna 18 CE Configuration Guide For technical assistance, product return authorization, and to order parts, accessories, or manuals within the United States, contact Hospira Technical Support Operations. 1-800-241-4002 For additional services and technical training courses, visit the website at www.hospira.com. For technical assistance and services outside the United States, contact the local Hospira sales office. CAUTION: Federal (USA) law restricts this infuser to sale by or on the order of a physician or other licensed practitioner. Plum A+, LifeCare PCA and Symbiq are registered trademarks of Hospira, Inc. Microsoft and Windows are not trademarks or registered trademarks of Hospira, Inc. The Symbiq infusion system uses components and technologies protected by U.S. Patent Numbers USD500326; USD515205; US5989222; US519175; US5462256; US5586868; US5816779; US5681285. Other patents pending. This document and the subject matter disclosed herein are proprietary information. Hospira retains all the exclusive rights of dissemination, reproduction, manufacture, and sale. Any party using this document accepts it in confidence, and agrees not to duplicate it in whole or in part nor disclose it to others without the written consent of Hospira. FC Complies with limits for Class B digital device established by FCC Rules, Part 15 Attention, consult accompanying documents. DUT INFORMATION FCC ID: STJ-20791 IC No: 5627A-20791 Certifications: FCC Part 15.247, 15.407 IC RSS-210, RSS-102 Device Name: Hospira MedNet 802.11 a/b/g Wireless Upgrade Module Note: For use with Hospira PlumA+ Infusion system Model Nos Covered: 20791-04-77, 20677-04-77 Note: Above two device model numbers are based on the same assembly. Device Model 20791-04-XX is meant for use in models 20792-04-XX and 20679-04-XX of PlumA+ Infusion System and device model 20677-04-XX is meant for use in models 12391-04-XX and 11971-04-XX Plum A+ Infusion Systems. © Hospira, Inc. 430-11541-001-END CE Configuration Guide
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res Page Count : 24 Page Mode : UseOutlines XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:04ee2da0-2062-450e-ba13-9cee34ecc513 Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : FrameMaker 7.2 Modify Date : 2007:01:25 18:08:54-08:00 Create Date : 2007:01:18 15:32:45Z Metadata Date : 2007:01:25 18:08:54-08:00 Document ID : uuid:9604a8b6-2623-4c0a-9da7-5c4fd891be31 Format : application/pdf Title : 430-11541-001.book Creator : 10135554 Author : 10135554EXIF Metadata provided by EXIF.tools