IDT Technology 80149200T-01 Remote Thermo Sensor (433.92MHz Tx) User Manual RAR801 THN801

IDT Technology Limited Remote Thermo Sensor (433.92MHz Tx) RAR801 THN801

User Manual

  Wireless In/Out Thermometer with Remote Thermo Sensor Item : 801.942.00 / 801.942.00T   USER MANUAL  INTRODUCTION Thank you for selecting this IKEA In/Out Thermometer. Please keep this manual handy as you use your new product. It contains practical instructions, technical specifications and warnings you should know about.  THERMOMETER OVERVIEW FRONT VIEW (FIG 1) 1.  Indoor temperature 2.  Outdoor temperature 3.   Sensor reception icon BACK VIEW (FIG 2) 1.  Battery compartment  2.   Wall mount hole 3.  RESET: Reset unit to default settings  4.  °C / °F: Select temperature unit REMOTE SENSOR (FIG 3) 1.  LED status indicator 2.  Wall mount hole 3.  Battery compartment   4.  RESET hole to reset the unit 5.  CHANNEL button: Change channels  FIG. 1     FIG. 2    FIG. 3         FIG. 4     GETTING STARTED INSERT BATTERIES 1.  Slide battery compartment open and insert batteries, matching polarities (see FIG. 2). 2.  Press RESET after each battery change. 3.  Place main unit using a table or wall stand (see FIG 4) within 30m (98 ft) of the sensor.  REMOTE SENSOR (  To set up the sensor: Slide battery compartment open and insert batteries, matching polarities (see FIG. 3). Place the sensor within 30 m (98 ft) of the main unit using the table stand or wall mount (see FIG 4).   The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results.  NOTE We recommend that you use alkaline batteries with this product for longer usage and consumer grade lithium batteries in temperatures below freezing.  SENSOR DATA TRANSMISSION To search for a sensor:  The main unit will automatically search for a signal from the remote sensor.  The sensor reception icon in the remote sensor area shows the status: ICON  DESCRIPTION  Main unit is searching for sensor(s)  A sensor has been found  Sensor 1 data received  and “--.- “ The sensor cannot be found   NOTE If the sensor is not found, check the batteries, obstructions, and remote unit location.  For best results: •  Place the sensor out of direct sunlight and moisture.  •  Position the sensor facing the main unit, minimizing obstructions. •  Place the sensor in a location with a clear view to the sky, away from metallic or electronic objects. •  Position the sensor close to the main unit during cold winter months.  TEMPERATURE UNIT Press °C / °F to change the temperature unit.  RESET Press RESET to return to the default settings.  PRECAUTIONS •  Do not subject the unit to excessive force, shock, dust, temperature or humidity. •  Do not cover the ventilation holes with any items such as newspapers, curtains etc. •  Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth. •  Do not clean the unit with abrasive or corrosive materials.  •  Do not tamper with the unit ’s internal components. This invalidates the warranty •  Only use fresh batteries. Do not mix new and old batteries. •  Images shown in this manual may differ from the actual display. •  When disposing of this product, ensure it is collected separately for special treatment. •  The contents of this manual may not be reproduced without the permission of the manufacturer. •  Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. •  Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use.  NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice.  SPECIFICATIONS TYPE  DESCRIPTION MAIN UNIT (801.942.00) L x W x H  70 x 59 x 23 mm  (3.11 x 2.33 x 0.91 in) Weight  241 g (8.5 oz)  without battery Operating Temperature range -5°C to 50°C  (23°F to 122°F) Temperature range   Resolution  0.1°C (0.2°F) Signal frequency   433 MHz Power  2 x UM-4 (AAA) 1.5 V batteries REMOTE UNIT (801.942.00T) L x W x H  96 x 50 x 22 mm  (3.8 x 2.0 x 0.9 in) Weight  62 g (2.22 ounces) Transmission range  30 m (98 ft) unobstructed Operating Temperature range -30°C to 60°C  (-22.0°F to 140°F) Power  1 x UM-3 (AA) 1.5 V batteries  EU-DECLARATION OF CONFORMITY Hereby, we declares that this model: 801.942.00 and 801.942.00T are in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Customer Service.   COUNTRIES RTT&E APPROVED COMPLIED  All EU countries, Switzerland and Norway  FCC STATEMENT This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.  WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  NOTE This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •  Reorient or relocate the receiving antenna. •  Increase the separation between the equipment and receiver. •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •  Consult the dealer or an experienced radio / TV technician for help.  DECLARATION OF CONFORMITY The following information is not to be used as contact for support or sales. Please call our customer service number for all inquiries instead.  We Name:  Oregon Scientific, Inc. Address:  19861 SW 95th Ave.,Tualatin,   Oregon 97062 USA Telephone No.:  1-800-853-8883  declare that the product  Product No.:  801.942.00 / 801.942.00T Product Name:  Wireless In/Out Thermometer Manufacturer:  IDT Technology Limited Address:  Block C, 9/F, Kaiser Estate,        Phase 1,41 Man Yue St.,    Hung Hom, Kowloon,      Hong Kong  is in conformity with Part 15 of the FCC Rules.  Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.

Navigation menu