INTRODUCTION
Wireless SmartClip
for CoaguChek® XS meter
Thank you for selecting our Wireless SmartClip for your Roche®
Coagulation Meter, which is a transmission Wireless SmartClip
accessory that can help you expand the meter from Infrared (IR) to
Bluetooth Low Energy (BLE) transmission. This means the testing
values can be transferred to a counterpart station, such as 2netTM
Hub or some mobile devices through BLE technology. From now on,
you can systematically monitor and manage your PT values via
wireless technology.
Mobile device with this logo
is compatible with the Wireless
SmartClip to achieve reliable transmission linkage.
IMPORTANT Please thoroughly read this user manual for all the
necessary information to operate your Wireless SmartClip.
OVERVIEW
1. LED light
2. Battery compartment
3. ON/OFF switch
4. Clip
5. Non-slippery pads
User Manual
BATTERY INSTALLATION
INSTALLATION
Battery is pre-installed in your BLE transmission Wireless SmartClip
when you purchase. Please regularly check the battery and replace
battery promptly as it may affect the transmission (refer to LED
indicator table on page. X).
To replace the battery:
•
Align the coagulation meter with the Wireless SmartClip and
insert the meter into the Wireless SmartClip with some
pressure until it clips into place.
UNINSTALLATION
1. Unscrew the battery compartment cover using a coin.
2. Remove the old battery and insert a new CR2032, 3V lithium
battery. Make sure to place the battery in the compartment
following the polarity +/-.
3. Return the compartment cover and screw it tightly.
•
Hold the Wireless SmartClip and pull the meter from the lefthand side with some pressure.
•
OPERATION
After the Wireless SmartClip is installed onto the meter, you need to
turn on the Wireless SmartClip to ensure the transmission works.
Make sure you power up the coagulation meter in priority of turning
on the Wireless SmartClip.
The effective distance between a counterpart station, such
as a hub, and the coagulation meter should be not far from each
other more than 10 meters or 32.8 feet
Turn on the Wireless SmartClip:
•
•
•
•
•
•
Slide the switch to ON. LED indicator lights up briefly in
green (given a normal battery status).
Run a prothrombin time (PT) measurement with the Roche
CoaguChek XS meter, as described in the operating manual
of the meter.
Once the PT measurement result is shown on the display of
the CoaguChek XS meter, please do not turn off the meter,
until the data transmissions will start automatically (within 60
seconds), which will be indicated by a green flashing LED.
Ensure that the blue LED indicates that data transmission
was successful (steady or flashing according to the table
below).
Once you saw the blue LED, your PT data has been
transmitted successfully.
If there is no blue LED, please make sure that the receiving
TM
device (e.g. 2net hub) is turned on and able to receive the
data from the Wireless SmartClip. Please wait until the
connection has been re-established automatically.
Note: If you measured your prothrombin time (PT) without
data transmission, the collected PT values will be
automatically transmitted once a data connection will be
established again.
Turn off the Wireless SmartClip:
•
Slide the switch to OFF after having ensured a successful
data transmission.
The effective distance between a counterpart station, such
TM
as a 2net hub, and the Wireless SmartClip should be not far from
each other more than 10 meters.
LED INDICATOR
Status
Normal
Battery
On in green
for
1 second
Low Battery
Critical Battery
On in green
for
1 second
Start mode
(pinging for the
meter)
OFF
OFF
Communicating
with Meter/Hub
Flashes in
green once
per second
Transmission
completed
Blue is on for
5 seconds
Flashes in
green and red
alternatively
Flashes in
blue and red
alternatively
Transmission
fails
/ Lost
Flashes in
red
Flashes in red
three times per
minute.
Flashes in red
three times per
minute.
Flashes in red
three times per
minute.
Flashes in red
three times per
minute.
Flashes in red
three times per
minute.
Power on
Flashes in red
very quickly
•
•
connection
•
•
SPECIFICATIONS
Dimension
(L x W x H)
84.5 x 131.5 x 36.6 mm
(3.3 x 5.2 x 1.5 inches)
Power
1 x CR2032 3V lithium battery
Weight
52.8 g (1.86 oz)
Operating temperature
10˚C to 40˚C (50˚F to 104˚F)
Storage temperature
-25˚C to 70˚C (-13˚F to 158˚F)
•
•
•
•
•
CARE INSTRUCTIONS
To ensure you use your product correctly and safely, read these
warnings and the entire user manual before using the product:
•
•
•
•
Do not wrap the Wireless SmartClip in a wet towel, nor with other
wet materials. Use a soft, slightly moistened cloth.
Do not place or wash the Wireless SmartClip under running
water instead clean it with a wet cloth.
Do not store the Wireless SmartClip in a hot (about 50°C) and
humid (about 90%) environment.
Do not subject the product to excessive force, shock, dust,
temperature changes, or humidity. Never expose the product to
direct sunlight for extended periods. Such treatment may result
in malfunction. Do not tamper with the internal components.
Doing so will terminate the product warranty and may cause
damage. The main unit contains no user-serviceable parts.
Take precautions when handling the battery.
Remove the battery whenever you are planning to store the
product for a long period of time.
When replacing the battery, use a new battery as specified in
this user manual.
The product is a precision instrument. Never attempt to take this
device apart. Contact the retailer or our customer service
department if the product requires servicing (depends on service
concept).
Do not touch the exposed electronic circuitry, as there is a
danger of electric shock.
Check all major functions following the User Manual if the device
has not been used for a long time.
When disposing of this product, ensure that this is done
according to the local guidelines..
Due to printing limitations, the displays shown in this manual
may differ from the actual display.
The contents of this manual may not be reproduced without the
permission of the manufacturer.
The technical specifications for this product and the contents
of the user manual are subject to change without notice.
CLEANING THE SLEEVE
It is important to follow the procedures below to clean and disinfect
the sleeve. Failure to follow these procedures may cause
malfunction of the sleeve.
Cleaning/Disinfecting the Exterior
Use only the following items for cleaning/disinfecting the Wireless
SmartClip for a contact time of >1 minute:
•
70% isopropyl alcohol
•
10% Sodium hypochlorite solution (1 part bleach to 9 parts
deionized water, made fresh every 24 hours)
Do not use any other disinfectants/cleaning solutions
on the Wireless SmartClip.
and Electronic Equipment). If you have any queries, please
refer to the local authorities responsible for waste disposal.
Used, fully discharged batteries must be disposed of
in a specially labeled collection container, at toxic
waste collection points or through an electrical
retailer. You are under legal obligation to dispose of
batteries correctly.
1. Clean/Disinfect the Exterior
With the SmartClip powered off, wipe the SmartClip’s exterior
clean.
•
Do not let liquid accumulate near any opening. Make sure that
no liquid enters the SmartClip.
2. Dry the Exterior
With a lint-free tissue, dry the SmartClip.
•
Wipe away residual moisture and fluids after cleaning the
SmartClip.
•
Allow wiped areas to dry for at least 10 minutes before
performing a test.
You will find these markings on batteries containing
harmful substances : Pb = battery containing lead, Cd =
battery containing cadmium, Hg = battery containing mercury.
Please dispose of the device in accordance with the directive
2006/66/EC.
EU-DECLARATION OF CONFORMITY
Hereby, we declare that BLE Wireless SmartClipor Roche CoaguChek
XS® Coagulation Meter (model: BG201) is in compliance with the
essential requirements and other relevant provisions of Directive
1999/5/EC. A copy of the signed and dated Declaration of Conformity is
available on request via our Roche Customer Service.
DISPOSAL
If you need to dispose of the Wireless SmartClip, do so in
accordance with the statutory regulations. Contact your town
administration or a disposal company.
Please dispose of the device in accordance with the
directive 2002/96/EC – WEEE( Waste Electrical
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) This device must accept any interference
received, including interference that may cause undesired operation.
WARNING Changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to
operate the equipment.
NOTE This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for support or
sales. Please visit our website at www.oregonscientific.com for all
enquiries. (depends on service concept)
We
Name: IDT Technology Limited
This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more
of the following measures:
declare that the product
Reorient or relocate the receiving antenna.
Manufacturer: IDT Technology Limited
Increase the separation between the equipment and receiver.
Address:
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio / TV technician for help.
Product No.:BG201
Product Name: BLE Wireless SmartClip
for Roche® CoaguChek XS Meter
Block C, 9/F, Kaiser Estate,
Phase 1, 41 Man Yue St., Hung Hom, Kowloon,
Hong Kong

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Create Date                     : 2014:05:20 19:11:02+08:00
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2014:05:20 19:11:48+08:00
Metadata Date                   : 2014:05:20 19:11:48+08:00
Format                          : application/pdf
Title                           : Microsoft Word - User Manual
Creator                         : 0310
Document ID                     : uuid:811f01b5-691c-4944-b67c-8c48db8c4159
Instance ID                     : uuid:26fbaef3-3858-44f6-bb8b-c802a8085e46
Has XFA                         : No
Page Count                      : 6
Author                          : 0310
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NMTBG201

Navigation menu