IDT Technology EMR211-01 BLE connected IN/out thermometer User Manual

IDT Technology Limited BLE connected IN/out thermometer

User Manual

 Model: EMR211User Manual  EN  INTRODUCTIONThank you for selecting our Oregon ScientificTM  Weather@Home Bluetooth-enabled Thermometer. which has changeable display on indoor and outdoor temperature.  Please keep this manual handy as you use your new product. It contains practical step-by-step instructions,  as  well  as  technical  specications  and warnings you should know about.OVERVIEWFRONT VIEW123456781.  Outdoor temperature reading (°C/°F)2.  Sensor channel indicator3.  : Sensor reception indicator4.  : outdoor remote sensor battery low5.  Indoor temperature reading (°C/°F)6.  : indoor remote sensor / main unit battery low7.   : BLE connection indicator8.  Ice alert LED indicatorREAR VIEWRESETSET1. 2. 3. 451.  SET: select temperature unit (°C/°F); pair up Bluetooth function2.  : select outdoor channels (1-5); search remote sensor3.  : select outdoor channels (1-5); auto-scan among sensors 4.  RESET: reset the unit to default settings5.  Battery compartmentREMOTE SENSOR (THN132N)         1                                                  23451.  LED status indicator2.  Wall mount hole3.  Battery compartment4.  RESET hole5.  CHANNEL switchREFERENCE  Other supported sensors include models: THN132N, THGN328N, THGR328N, BTH sensor, THN318N.GETTING STARTEDINSERT BATTERIES1.  Remove the battery compartment.2.  Insert the batteries, matching the polarities (+/-).3. Press RESET after each battery change. LOCATION MEANINGOutdoor temperature area Outdoor sensor batteries lowIndoor temperature areaIndoor sensor batteries low / main unit batteries lowREMOTE SENSORThe main unit can collect data from up to 5 sensors.To set up the sensor:1.  Open the battery compartment.2.  Select a channel then press RESET.3.  Close the battery door.4.  Place the sensor within 98 ft (30 m) of the main unit using the table stand or wall mount.TIP  Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 5 ft (1.5 m); and can shield it from direct sunlight or wet conditions for an accurate reading.1.5 m (5 ft) Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.SENSOR DATA TRANSMISSIONTo search for a sensor:1. Press   or   to select among 5 different outdoor channels of remote sensors.2.  Press and hold   for 2 seconds to enforce researching for the selected sensor.To auto-scan among sensors:•   Press and hold   for 2 seconds to enable auto-scan function for all 5 channels. The temperatures will be displayed automatically in sequential order(Channel 1,2,3,4,5)The sensor reception icon at the front of the main unit shows the status:ICON DESCRIPTIONMain unit is searching for sensor(s).A channel has been found.The sensor cannot be found.TIP  The transmission range may vary depending on many factors. You may need to place the sensor(s) in different locations to get the best result(s). TEMPERATURETo select temperature unit:•   Press SET to select °C or °F for temperature readings. ICE WARNING If the channel 1 sensor falls from  37°F  to  28°F  (3°C  to  -2°C),  LED  indicator                                 in the front of the main unit will flash continuously, and will stop flashing once the temperature is out of this range.•   Press   and   at the same time to deactivate the ice alert warning. •   The ice alert warning will be disable/enabl again when the temperature falls again from 37°F to 28°F (3°C to -2°C). As ice alert is only applicable to channel 1, to prevent ashing of LED, select channel 2-5 on outdoor sensor.RESETPress RESET at the rear of the main unit to return to the default settings.CONNECT WITH YOUR MOBILE DEVICEYou can remotely set the thermometer and read the weather information through Bluetooth 4.0 using your mobile device with the downloaded application from the Apple  Store. To  quickly  nd  the  application,  type ‘Weather@Home’ as keyword in the search engine. Ensure your mobile device is compatible with iOS 5 or Android 4.3 with Bluetooth®v4.0.PAIRING YOUR THERMOMETERFirst of all, you need to pair your thermometer with your mobile device.   will ash on the screen of the weather station while pairing and be on after successful pairing. To pair up a sensor: At the rear of the main unit, press and hold SET for 2 seconds to enable a pair-up for the main unit. 1. Tap   to enter SETTINGS screen.2.  Tap on STATION area. 3. Tap Pair Up. Searching… displays. If you want to cancel the pairing, tap Cancel. 4.  Once the pairing is successful, it will return to STATION screen. 5.  Tap on each channel to rename it. (Up to 20 characters including space are allowed). Tap   if completed. Tap   to exit. To remove sensor:To remove any sensor from the weather station, Tap Remove station on STATION screen, all the sensors will be removed at the same time. To reposition the sensors on screen: 1. On STATION screen, tap  . 2.  Press and hold   at the right side of a sensor. Drag it to your desired position. 3. Tap   to conrm. SETTINGSYou can set your weather station through the application, such as measurement units. The settings are as follows:•   Temperature •   Barometric (not available in EMR211)•   Rainfall (not available in EMR211)•   Wind speed (not available in EMR211)•   Altitude (not available in EMR211)•   Show unavailable sensor•   Automatically sync time•   Show Sea Level Pressure (not available in EMR211)To select the measurement unit:1. Tap   to view the measurement unit options. 2.  Tap on your desired unit. 3. Tap   to go back to the previous screen. VIEW CURRENT READINGS  You can directly view all the                    temperature readings from               different sensors through the               application at a time. The               readings are in the HOME             screen.                    If low battery icon                               displays on the screen, please               replace the batteries for the             corresponding device. To show unavailable sensor: If the sensor is out of range, the readings are interrupted and - - (dash mode) displays on the screen. If you do not want to show the unavailable sensor: •   On SETTINGS screen, touch and slide the button to right to turn on the function, or sliding to left to turn it off. To automatically synchronize time: Time and date on your weather station could be automatically synchronized by your mobile device.•   On SETTINGS screen, touch and slide the button to right to turn on the function, or sliding to left to turn it off. VIEW HISTORY READINGSYou can view history through the application. The history could also be presented in graphs (past 24 hours or past 7 days). To view the history:1.  Tap on your desired sensor area on the screen. 2. Tap   to select your desired data or tap   to sort the data by date.   OPTIONAL SENSOR FOR ADDITIONALINFORMATIONBy applying the sensor (Model: BTH Sensor) at the same time, you can also view the following information using your mobile device.•   Weather Forecast •   Air Pressure•   Outdoor HumidityUSEFUL REFERENCE  The optional sensor (Model: BTH Sensor) can be purchased from Oregon Scientic.PRECAUTIONS•   Do not subject the unit to excessive force, shock, dust, temperature or humidity.•   Do not cover the ventilation holes with any items such as newspapers, curtains etc.•   Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.•   Do not clean the unit with abrasive or corrosive materials. •   Do not tamper with the unit’s internal components. This invalidates the warranty.•   Only use fresh batteries. Do not mix new and old batteries.•   Images shown in this manual may differ from the actual display.•   When disposing of this product, ensure it is collected separately for special treatment and not as household waste.•   Placement of this product on certain types of wood may result in damage to its nish for which Oregon Scientic will not be responsible. Consult the furniture manufacturer’s care instructions for information.•   The contents of this manual may not be reproduced without the permission of the manufacturer.•   Do not dispose old batteries as unsorted municipal waste.Collection of such waste separately for special treatment  is necessary.•   Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before rst use. The technical specications for this product and the contents of the user manual are subject to change without notice. Features and accessories will not be available in all countries. For more information, please contact your local retailer.SPECIFICATIONSTYPE DESCRIPTIONMAIN UNITL x W x H 93 x 68 x 30 mm(3.66 x 2.68 x 1.18 in)Weight 96g (3.39 ounces) include batteryTemperature range -5°C to 50°C (23°F to 122°F)Signal frequency 433 MHzPower 2 x AAA batteriesTemperature range for ice alert 3°C to -2°CREMOTE THERMO SENSOR (THN132N)L x W x H 96 x 50 x 22 mm(3.78 x 1.97 x 0.87 in)Weight 62g (2.22 ounces)Transmission range 30 m (98 ft) unobstructedTemperature range -20°C to 60°C (-4°F to 140°F)Power 1 x UM-3 (AA) 1.5V batteriesABOUT OREGON SCIENTIFICVisit our website www.oregonscientic.com to learn more about Oregon Scientic products. For any enquiry, please contact our Customer Services at info@oregonscientic.com. Oregon  Scientic  Global Distribution  Limited reserves the right to interpret and construe any contents, terms and provisions in this user manual and to amend it, at its sole discretion, at any time without prior notice. To the extent that there is any inconsistency between the English version and any other language versions, the English version shall prevail. EU-DECLARATION OF CONFORMITYHereby, Oregon Scientic, declares  that Weather@Home Thermo Bluetooth-enabled Thermometer (model: EMR211) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientic Customer Service.     COUNTRIES RTTE APPROVAL COMPLIED                       All EU Countries, Switzerland   CH                    and Norway     N FCC STATEMENTThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. WARNING  Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:Reorient or relocate the receiving antenna.Increase the separation between the equipment and receiver.Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.Consult the dealer or an experienced radio / TV technician for help.DECLARATION OF CONFORMITYThe following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientic.com), or on the warranty card for this product) for all inquiries instead.WeName:    Oregon Scientic, Inc.Address:         10778 SW Manhasset Dr.     UNIT B-2 Tualatin, Or 97062 USATelephone No.:  1-800-853-8883Declare that the product Product No.:  Model: EMR211Product Name:    Manufacturer:  IDT Technology LimitedAddress:   Block C, 9/F, Kaiser Estate,    Phase 1, 41 Man Yue St.,             Hung Hom, Kowloon,     Hong KongBLE connected IN/out thermometerBLE connected IN/out thermometer

Navigation menu