IDT Technology IH600-01 Instant Forecast Hub (433.92MHz Tx) User Manual i600 EN RUNNING UM R2 indd

IDT Technology Limited Instant Forecast Hub (433.92MHz Tx) i600 EN RUNNING UM R2 indd

User Manual

EN1CONTENTSIntroduction ............................................................... 2Packaging contents .................................................. 2Overview .................................................................... 3  Front view ............................................................... 3  Back view ............................................................... 3  USB communications hub ...................................... 4  Outdoor thermo-hygro sensor ................................ 4Getting Started .......................................................... 4  Set up remote sensor ............................................. 4  Set up main unit ..................................................... 5Set up software (first time use) ............................... 6  Windows XP ........................................................... 6  Windows Vista ........................................................ 6Disable sleep mode .................................................. 6  To disable sleep mode on computer   (Windows XP ) ....................................................... 6  To disable sleep mode on computer   (Windows Vista) ..................................................... 7Set up USB communications hub ........................... 7Main unit screen display .......................................... 7  To change display modes ....................................... 7  To view different warning messages ...................... 8  Weather forecast .................................................... 8Clock .......................................................................... 8  To manually set clock ............................................. 8Alarm ......................................................................... 8  To set alarm ........................................................... 8  To activate / deactivate alarm ................................ 8  To silence alarm ..................................................... 8Backlight ................................................................... 8Reset .......................................................................... 8Specifications ........................................................... 9Precautions ............................................................... 9About Oregon Scientific ........................................ 10EU-Declaration of Conformity ............................... 10FCC Statement .........................................................11  Declaration of conformity ..................................... 11Global 5-Day Weather Adviser IIModel: I600USER MANUALi600_EN_RUNNING_UM_R2.indd   1 2008.7.22   5:50:30 PM
EN2INTRODUCTIONThank you for selecting the Oregon Scientific™ Global 5-Day Weather Adviser II (I600).The weather  station is  capable of  connecting to  a PC computer  using the  USB  connection.  By installing  the PC  software, world  cities  can be  user-selectable. The software  can  also  download  and  display  the  latest weather data and time of the selected cities.For full details see software instructions.PC system requirementsThe  minimum  system  requirements  for  use  of  the software is:•  Operating system: Microsoft Windows XP SP2 or Vista•  Processor: Pentium 4 or above•  RAM: Min. 512MB•  Hard disk free space: Min. 512MB•  Screen  Display  Area:  1024  x  768  pixels (recommended)  NOTE   The  USB  is  only  used  for  the  uploading  and downloading  of  weather  data.  It  is  not  to  be  used  for charging battery power.  NOTE    Please  keep  this  manual  handy  as  you  use your  new  product.  It  contains  practical  step-by-step instructions,  as  well  as  technical  specifications  and warnings you should know about.PACKAGING CONTENTS1 x USB Cable1 x Remote Sensor1 x USBCommunications Hub3 x AA UM-3 1.5V Batteries2 x AAAUM-4 1.5V Batteries1 x Main Uniti600_EN_RUNNING_UM_R2.indd   2 2008.7.22   5:50:41 PM
EN3OVERVIEWFRONT VIEW1 2 3 4 56789101112131.   : Information signal reception indicator2.   : Indicate AM / PM3.   : Indicate daily alarm is On4.   : Indicate alarm time is displayed5.   : Main unit batteries low6.  City  name  /  Clock  /  Calendar  /  Scrolling  warning message7.  Today’s weather forecast (home environment)8.  Today’s regional weather forecast (user selected city)9.   : Indicate outdoor sensor reception status10.   : Sensor batteries low11.  Current  indoor  /  outdoor  temperature  /  humidity (home environment)12. Today’s regional HI / LO temperature (user selected city)13. Next  4 day  regional weather forecast with  HI /  LO temperature (user selected city)BACK VIEW123457681.  SNOOZE · MESSAGE: Activate snooze alarm; turn on backlight; toggle between city / weather warning / advisory message2.  ALARM: Change settings / display; activate/deactivate alarm; set alarm3.  MODE:  Toggle  between  calendar  display  and currently selected city; set clock4.  UP: Initiate sensor search; increase value of the setting;  display next city’s data5.  DOWN: Decrease value of the setting; display previous city’s data6.  Wall mount holes7.  RESET: Reset unit to default settings8.  ºC / ºF: Select temperature uniti600_EN_RUNNING_UM_R2.indd   3 2008.7.22   5:51:00 PM
EN4USB COMMUNICATIONS HUBFRONT VIEW BACK VIEW   Front View:1.  LED status indicator: Blink during registration with main unit or during sensor search; indicate a successful USB connectionBack View:1.  SEARCH: Initiate search for remote sensors2.  RESET: Reset USB Communications Hub to default settings3.  USB port: Upload / download records to / from PCOUTDOOR THERMO-HYGRO SENSORFRONT VIEW BACK VIEW1132Front View:1.  LED status indicator:  Blink when transmitting a readingBack View:1.  RESET: Reset unit to default settings2.  Channel switch3.  Battery compartmentGETTING STARTEDSET UP REMOTE SENSOR1.  Slide open the battery door.2.  Select channel.3.  Insert  the  batteries,  matching the  polarities  (+  /  -) and press RESET.4.  Close the battery door.i600_EN_RUNNING_UM_R2.indd   4 2008.7.22   5:51:04 PM
EN5 NOTE •  Install batteries in the remote sensor before installing the USB Communications Hub and main unit.•  Press RESET after each battery change.5.  Secure the sensor in the desired location using the wall mount bracket.6.  Press  SEARCH  on  USB  Communications  Hub  to initiate  search  and  start  receiving  data  from  the sensor. NOTE  USB Communications Hub will search only for already  registered  sensor  or  new  sensor  reset  within last 30 minutes. To register a new sensor, reset sensor prior to search.7.  Press and hold UP and DOWN on the main unit to initiate sensor search.For best results:•  Place the sensor within 100 m (300 ft) of the USB Communications Hub and main unit.•  Position  the  sensor  so  that  it  faces  the  USB Communications  Hub  and  main  unit,  minimizing obstructions such as doors, walls and furniture.•  Place the sensor out of direct sunlight and moisture.•  Place the sensor in a location with a  clear view to the sky, away from metallic / electronic objects.•  Position the sensor close to the USB Communications Hub  and  main  unit  during  cold  winter  months  as below-freezing  temperatures  may  affect  battery performance and signal transmission. TIP   The transmission  range may  vary depending  on many factors. You may need to experiment with various locations to get the best results.  NOTE   Use  alkaline  batteries  for  longer  usage  and consumer grade lithium batteries in temperatures below freezing.SET UP MAIN UNIT1.  Remove the battery compartment cover.2.  Insert the batteries, matching the polarities.3.  Press RESET after each battery change. NOTE  Batteries should not be exposed to excessive heat such as sunshine or fire.i600_EN_RUNNING_UM_R2.indd   5 2008.7.22   5:51:09 PM
EN6SET UP SOFTWARE (FIRST TIME USE)WINDOWS XPTo install software:1.   Run CD software provided.2.   Setup  wizard dialogue  box will  appear and  guide you through the installation process.3.   After  successful  installation,  double  click  on     desktop shortcut.4.   Click  DISPLAY  in  Oregon  Weather  Station dialogue box.Select Cities:5.   Click   next to 5 day weather forecast.6.   On the new page that appears, there will be cities set as default.  To change, click CHANGE.7.   In  the  Settings…  dialogue  box,  City  tab,  select cities  in the  drop  down menus (Region;  Country  / Area; City / US Zip).8.   Click OK.WINDOWS VISTATo Disable User Access Control (UAC):1.   From the desktop, My Computer > Control Panel >  User  Accounts  and  Family  Safety  >  Change your  Windows  password > Turn  User  Account Control On or Off.2.   Deselect the UAC option by un-ticking.3.   Follow steps 1-8 from above section.DISABLE SLEEP MODETo  allow  for  continuous  update  of  data,  ensure  Sleep Mode on computer is disabled.TO DISABLE SLEEP MODE ON COMPUTER (WINDOWS XP)1.  Right click on Desktop.2.  Choose “Properties”.3.  Click on “Screen Saver” Tab in the Display Properties window.4.  Click on “Power” located at the bottom half of window.5.  A new window “Power Options Properties” will open.6.  Under “System standby” option, choose “Never” in drop down menu.7.  Click “Apply” and then click “OK”.8.  Previous window will return.  Click “OK” to confirm and exit.i600_EN_RUNNING_UM_R2.indd   6 2008.7.22   5:51:19 PM
EN7TO DISABLE SLEEP MODE ON COMPUTER (WINDOWS VISTA)1.  Right click on Desktop.2.  Choose “Personalize”.3.  Click  on  “Screen  Saver”  Tab  in  the  Display Properties window.4.  Click  on  “Change  Power  Settings”  located  at  the bottom half of window.5.  Select “High Performance” and click “Change plan settings”.6.  Click “Change advanced power settings”.7.  Click “Sleep” and click “Hibernate after”.8.  Click “Setting” and set “0” minutes.9.  Click “Apply” and then “OK”.SET UP USB COMMUNICATIONS HUB NOTE  Set up the remote sensor before installing the USB Communications Hub.Approximately  30  minutes  daily  connection  to computer  is  sufficient  to  receive  current  weather data.  For  continuous  use,  always  connect  the  USB Communications  Hub  to  the computer  using  the  USB cable provided.  There is a registration mode with the main unit when the USB Communications Hub is turned on the first time, or after each installation. IMPORTANT  Registration can take half an hour.  Do not turn off computer / disconnect USB from computer during this time.Continuous  display  of    indicates  data  transfer  is successful.MAIN UNIT SCREEN DISPLAYTO CHANGE DISPLAY MODESTo toggle between 5 cities:Press UP or DOWN.To view alarm time and status:Press ALARM.To  toggle  between  calendar  display  and  currently selected city:Press MODE.i600_EN_RUNNING_UM_R2.indd   7 2008.7.22   5:51:21 PM
EN8TO VIEW DIFFERENT WARNING MESSAGESPress SNOOZE · MESSAGE.WEATHER FORECASTFor  your  convenience  there  is  an  enclosed  sheet listing  individual  weather  icons  and  their  respective meanings.The number of days with weather forecast available is dependent on data provided by local observatories.CLOCKTO MANUALLY SET CLOCK NOTE  This product is designed to synchronise its calendar clock automatically with the information downloaded from the PC. 1.  Press and hold MODE to enter settings.2.  Press UP / DOWN to change settings.3.  Press MODE to confirm settings.The  settings  order  is:  12/24  hour  format,  hour, minute, year, month-day  / day-month,  month, day and language.  NOTE    The  language  options  are  English  (ENG), German  (GER),  French  (FRE),  Italian  (ITA),  Spanish (SPA) and Russian (RUS).ALARMTO SET ALARM1.  Press ALARM to enter Alarm mode.2.  Press and hold ALARM to enter settings.3.  Press UP / DOWN to set hour / minute.4.  Press ALARM to confirm settings.TO ACTIVATE / DEACTIVATE ALARM1.  Press ALARM to enter Alarm mode.2.  Press  ALARM  repeatedly  until  desired  option  is displayed (   / “OFF”).3.  Press MODE to confirm and return to clock display.TO SILENCE ALARM•  Press SNOOZE · MESSAGE to silence it for 8 minutes.OR•  Press any key  to turn the  alarm off and  activate it again after 24 hours. BACKLIGHTPress SNOOZE · MESSAGE to activate LED backlight for 8 seconds.RESETPress RESET to return to the default settings.i600_EN_RUNNING_UM_R2.indd   8 2008.7.22   5:51:21 PM
EN9SPECIFICATIONSMAIN UNITDimensions (L x W x H)  189 x 42 x 119 mm   (7.4 x 1.7 x 4.7 in)Weight  350 g (12.35 oz) without batteryPower  3 x UM-3 (AA) 1.5V batteriesINDOOR TEMPERATURETemperature unit  °C / °FDisplayed range  0°C to 50°C (32°F to 122°F)Operating range  -5°C to 50°C (23°F to 122°F)Resolution  0.1°C (0.2°F)INDOOR RELATIVE HUMIDITYDisplayed range  2% to 98%Operating range  25% to 90%Resolution  1%USB COMMUNICATIONS HUBDimensions (L x W x H)  68 x 46 x 136 mm   (2.7 x 1.8 x 5.4 in)Weight  92 g (3.2 oz) without batterySignal frequency  433 MHzTransmission range  100 m (300 ft) unobstructedInformation update  Approximately every 10 minutesRegistration period  Approximately 20 minutesPower  Via PC through USB cableOUTDOOR REMOTE THERMO-HYGRO SENSORL x W x H  62 x 20 x 90 mm   (2.4 x 0.8 x 3.5 in)Weight  50 g (1.76 oz) without batteryTemperature range  -20°C to 60°C  (-4°F to 140°F)Temperature resolution  0.1°C (0.2°F)Humidity range  5% to 95%Humidity resolution  1%Signal frequency   433 MHzTransmission range  100 m (300 ft) unobstructedTransmission period  Approximately every 60 secondsNumber of channels  3Power  2 x UM-4 (AAA) 1.5V batteriesCLOCK / CALENDARClock display  HH:MMHour format  12hr AM/PM or 24hrCalendar  DD/MM or MM/DDPRECAUTIONS•  Do  not subject  the unit  to  excessive force,  shock, dust, temperature or humidity.•  Do  not  cover  the  ventilation  holes  with  any  items such as newspapers, curtains etc.•  Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.•  Do not clean the unit with abrasive or corrosive materials. •  Do not tamper with the unit’s internal components. This invalidates the warranty.i600_EN_RUNNING_UM_R2.indd   9 2008.7.22   5:51:22 PM
EN10•  Only  use fresh  batteries. Do  not mix new  and old batteries.•  Images  shown  in  this  manual  may  differ from  the actual display.•  When disposing of this product, ensure it is collected separately for special treatment and not as normal household waste.•  Placement  of  this  product  on  certain  types  of  wood may  result  in damage  to its  finish  for  which Oregon Scientific will not be responsible. Consult the furniture manufacturer's care instructions for information.•  The contents of this manual may not be reproduced without the permission of the manufacturer.•  Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.•  Please  note  that  some  units  are  equipped  with  a battery  safety  strip.  Remove  the  strip  from  the battery compartment before first use. NOTE  The technical specifications for this product and the contents of the user manual are subject to change without notice. NOTE  Features and accessories will not be available in all  countries.  For more information,  please contact your local retailer.ABOUT OREGON SCIENTIFICVisit our website (www.oregonscientific.com) to learn more about Oregon Scientific products. If you’re in the US and would  like  to  contact  our  Customer  Care  department directly, please visit: www2.oregonscientific.com/service/support For international inquiries, please visit: www2.oregonscientific.com/about/internationalEU-DECLARATION OF CONFORMITYHereby, Oregon Scientific,  declares that  this Global  5-Day Weather Adviser II (Model: I600) is in compliance with  the  essential  requirements  and  other  relevant provisions of Directive 1999/5/EC. A copy of the signed and  dated  Declaration  of  Conformity  is  available  on request via our Oregon Scientific Customer Service.COUNTRIES RTTE APPROVAL COMPLIED                       and Norway    N       All EU countries, Switzerland  CHi600_EN_RUNNING_UM_R2.indd   10 2008.7.22   5:51:22 PM
EN11FCC STATEMENTThis  device  complies  with  Part  15  of  the  FCC  Rules. Operation is subject to the following two conditions: (1) This device may not  cause  harmful interference,  and (2) This device  must  accept  any  interference  received,  including interference that may cause undesired operation.  WARNING    Changes  or  modifications  not  expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  NOTE    This  equipment  has  been  tested  and  found to  comply  with  the  limits  for  a  Class  B  digital  device, pursuant  to  Part  15  of  the  FCC  Rules.  These  limits are designed to  provide reasonable  protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency  energy  and,  if  not  installed  and  used  in accordance  with  the  instructions,  may  cause  harmful interference  to  radio  communications.  However,  there is  no  guarantee  that  interference  will  not  occur  in  a particular  installation.  If  this  equipment  does  cause harmful  interference  to  radio  or  television  reception, which  can  be  determined  by  turning  the  equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:•  Reorient or relocate the receiving antenna.•  Increase  the  separation  between  the  equipment and receiver.•  Connect  the  equipment  into  an  outlet  on  a  circuit different from that to which the receiver is connected.•  Consult  the  dealer  or  an  experienced  radio  /  TV technician for help.DECLARATION OF CONFORMITYThe following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientific.com, or on the warranty card for this product) for all inquiries instead.WeName:  Oregon Scientific, Inc.Address:  19861 SW 95th Ave.,Tualatin,  Oregon 97062 USATelephone No.:  1-800-853-8883declare that the product Product No.:  I600Product Name:  Global 5-Day Weather Adviser IIManufacturer:  IDT Technology LimitedAddress:  Block C, 9/F, Kaiser Estate,  Phase 1,41 Man Yue St.,      Hung Hom, Kowloon,   Hong Kongis in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.i600_EN_RUNNING_UM_R2.indd   11 2008.7.22   5:51:22 PM
EN12Global 5-Day Weather Adviser IIModel: I600USER MANUALi600_EN_RUNNING_UM_R2.indd   12 2008.7.22   5:51:23 PM
EN13© 2008 Oregon Scientific. All rights reserved.086L005367-011Global 5-Day Weather Adviser IIModel: I600USER MANUALi600_EN_RUNNING_UM_R2.indd   13 2008.7.22   5:51:23 PM

Navigation menu