IDT Technology PSR01-01 Wireless Outdoor Thermo and Humidity Sensor User Manual PSr01 spc

IDT Technology Limited Wireless Outdoor Thermo and Humidity Sensor PSr01 spc

User Manual

Wireless Outdoor Temperature and Humidity Sensor(Model #: PS-R01)User ManualENPS R01A English Cover r7 10/17/03, 6:29 PM1
1ENTABLE OF CONTENTSAbout Oregon Scientific ............................................ 1About this guide .......................................................  2Product overview ....................................................... 3Getting started .......................................................... 4Set up ................................................................. 4Change channel .................................................. 5Comfort zone ...................................................... 6Trends ................................................................. 6Low battery warning ............................................ 7Reset system ............................................................. 7Safety and care ........................................................  7Warnings ................................................................... 7Troubleshooting ........................................................  8Specifications ............................................................ 9FCC Notice ............................................................. 10ABOUT OREGON SCIENTIFICVisit our website (www.oregonscientific.com) to learnmore about other Oregon ScientificTM products such asdigital cameras, projection clocks, health and fitnessgear, and weather stations. The website also includescontact information for our customer servicedepartment, in case you need to reach us.PS R01A English r7 10/17/03, 6:29 PM1
2ENABOUT THIS GUIDECongratulations on your selection of the Philippe Starckwith Oregon Scientific Wireless Outdoor Temperatureand Humidity Sensor (PS-R01).This sensor is compatible with a wide variety of weathermonitoring tools, and can be used with any STARCK /Oregon Scientific Weather Stations.Keep this manual handy as you use your new product. Itcontains practical step-by-step instructions, as well astechnical specifications and warnings you should know.In this box, you will find:• Remote unit• BatteriesPS R01A English r7 10/17/03, 6:29 PM2
3ENPRODUCT OVERVIEW DESCRIPTIONS1. Temperature / Trend display2. Low battery icon3. Humidity / Trend / Comfort Level display4. °F/°C switch5. Channel switch6. Reset button7. Battery compartment8. Wall mount hole9. Battery compartment lid546789123PS R01A English r7 10/17/03, 6:29 PM3
4ENSET UP1. Place remote unit as close as possible to themain unit.2. Remove the battery compartment lid.(You will need a small Phillips screwdriver.)3. Assign a Channel Number.If you are using more thanone remote unit, select adifferent channel numberfor each unit.4. Set the measurement unit.5. Insert the batteries. Matchthe polarity, as shown inthe battery compartment.6. Press RESET with the point of a blunt object(such as a ball point pen).GETTING STARTEDThis product can be used with up to 2 remote units totransmit outdoor temperature and humidity data to amain (indoor) unit. The measurement unit (°F or °C) andchannel number (1, 2, or 3) switches are located in thebattery compartment, and should be set prior toinstallation.Additional remote units sold separately.NOTEPS R01A English r7 10/17/03, 6:29 PM4
5EN7. Replace the battery compartment lid. Secure.8. Mount the remote unit on a flat surface usingthe recess hole on the back of the unit. Forbest results:• Place the unit out ofdirect sunlight andmoisture.• Do not place theremote unit morethan 60 - 90 feet(20 - 30 meters) fromthe main (indoor) unit.• Position the unit so that it faces the main(indoor) unit. Minimize obstructions suchas doors, walls, and furniture.You may need to experiment with variouslocations to get the best reception.9. Once the batteries are in place, the sensor willtransmit signals approximately every 40 seconds.The readings shown on the main unit depend onwhich remote sensor (1, 2, or 3) is selected.Refer to the main unit User Manual for moreinformation.CHANGE CHANNELRepeat the Set Up procedure (   pg.4). In Step 3,select a different Channel Number.PS R01A English r7 10/17/03, 6:29 PM5
6ENComfort68 - 77 °F(20 - 25 °C) 40 - 70%WetAny >70%AnyDry<40%COMFORT ZONEThe outdoor comfort zones are shown under thefollowing conditions.TRENDSThe trend arrow for the last 30 minutes always displays.Outdoor temperature and humidity trends are shownseparately.Zone Temperature Relative Humidity+0.9 °F> +3%SteadySteady-0.9 °F< -3%Temperature Relative HumidityTrendPS R01A English r7 10/17/03, 6:29 PM6
7ENLOW BATTERY WARNINGReplace the batteries whenever the low battery signal(   ) shows on the remote unit, or on the remote unitarea of the main unit.Do not use rechargeable batteries. Properlydispose used batteries by taking them to an authorizeddisposal station.RESET SYSTEMThe RESET button is located in the batterycompartment. Press it with the point of a bluntobject (such as a ball point pen) whenever youchange the batteries, or whenever performance isnot behaving as expected (e.g., unable to establishradio frequency link with main unit). Refer to theUser Manual for the main unit for more information.SAFETY AND CAREWash the unit with a slightly damp cloth and milddetergent. Avoid dropping the unit or placing it indirect sunlight or in damp or high-traffic locations.WARNINGSThis product is designed to give you years of serviceif handled properly. Observe the following guidelines:• Never immerse the unit in water. This cancause electrical shock and damage the unit.NOTEPS R01A English r7 10/17/03, 6:29 PM7
8ENCheck location(  pg.5)Check batteries(   pg.4, 7)• Do not subject the main unit to extreme force,shock, or fluctuations in temperature or humidity.• Do not tamper with the internal components.• Do not mix new and old batteries or batteries ofdifferent types. Do not use rechargeablebatteries with this product.• Remove the batteries if storing this product fora long period of time.• Do not scratch the LCD display.• Do not make any changes or modifications tothis product. Unauthorized changes may voidyour right to use the product.• The contents of this user manual are subject tochange without notice.• Images not drawn to scale.TROUBLESHOOTINGCheck here before contacting our customer servicedepartment.Problem RemedySymptomMain unit shows“LLL” or “HHH”Temperature isout-of-range.TempRemoteunitCannot locatemain unitPS R01A English r7 10/17/03, 6:29 PM8
9ENSPECIFICATIONSDimensionsL x W x H 3 x 1.4 x 3.1 in(75 x 35 x 78.3 mm)Weight 0.3 lbs / 136 grams with batteryTemperatureUnit °F or °CRange -4 °F to 140 °F (20 °C to 60 °C)Resolution 0.2 °F (0.1 °C)Relative humidityRange 25% to 95%Resolution 1%FrequencyRF frequency 433 MHzRange 30 meters (98 feet) with noobstructionsTransmission approximately every 40 secondsChannel No. 1, 2, or 3Unit °F or °CPower 2 x UM-4 (AAA) 1.5V alkalinebatteriesPS R01A English r7 10/17/03, 6:29 PM9
10ENFCC NOTICEThis equipment has been tested and found to complywith the limits for a Class B digital device, pursuant toPart 15 of the FCC Rules. These limits are designed toprovide reasonable protection against harmfulinterference in a residential installation. This equipmentgenerates, uses and can radiate radio frequencyenergy and, if not installed and used in accordance withthe instructions, may cause harmful interference to radiocommunications.However, there is no guarantee that interference will notoccur in a particular installation. If this equipment doescause harmful interference to radio or televisionreception, which can be determined by turning theequipment off and on, the user is encouraged to try tocorrect the interference by one or more of the followingmeasures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipmentand receiver.• Connect the equipment into an outlet on acircuit different from that to which the receiveris connected.• Consult the dealer of an experienced radio/TVtechnician for help.Warning : Changes or modifications not expresslyapproved by Oregon Scientific for compliance couldvoid the warranty and your authority to use thisequipment.PS R01A English r7 10/17/03, 6:29 PM10
11ENDECLARATION OF CONFORMITYThe following declaration is required for us to fully meetFCC requirements. The information below is not to beused as contact for support or sales. Please call ourcustomer service number (listed on our website atwww.oregonscientific.com, or on the warranty card forthis product) for all inquiries instead.We declare that the product is in conformity withPart 15 of the FCC Rules.Name: Oregon Scientific, Inc.Address: 19861 SW 95th Place, Tualatin,Oregon 97062 USAProduct No.: Remote Thermo HygroPS-R01Manufacturer: IDT Technology LimitedAddress: Block C, 9/F, Kaiser Estate,Phase 1, 41 Man Yue St.,Hung Hom, Kowloon, Hong KongPS R01A English r7 10/17/03, 6:29 PM11
12ENCAUTION— The content of this manual is subject to changewithout further notice.— Due to printing limitation, the displays shown inthis manual may differ from the actual display.— The contents of this manual may not bereproduced without the permission of themanufacturer.© 2003 Oregon Scientific. All rights reserved.Operation is subject to the following two conditions:1) This device may not cause harmful interference.2) This device must accept any interference received,including interference that may cause undesiredoperation.PS R01A English r7 10/17/03, 6:29 PM12