IDT Technology RAR213HGX-01 BLE connected In/Out Thermometer User Manual

IDT Technology Limited BLE connected In/Out Thermometer Users Manual

Users Manual

Weather@Home Thermo Plus Bluetooth-enabled Thermo-Hygro MonitorUSER MANUALRAR213HGXRAR213HGX-Manual-EN-R8.indd   1 2018/6/12   下午2:59
2ENWeather@Home Thermo PlusBluetooth-enabled Thermo-Hygro MonitorModel: RAR213HGXUSER MANUALCONTENTSIntroduction-----------------------------------------------------------------3Overview ---------------------------------------------------------------------3Front View ---------------------------------------------------------------3Rear View ----------------------------------------------------------------4Remote Sensor (THGN132N) --------------------------------------4Getting Started ------------------------------------------------------------4Insert Batteries ---------------------------------------------------------4Remote Sensor ------------------------------------------------------------5Sensor Data Transmission ------------------------------------------5Clock----- ---------------------------------------------------------------------6Manually Set Clock ---------------------------------------------------- 6Temperature And Humidity --------------------------------------------6Ice Warning--------------------------------------------------------------6Backlight---------------------------------------------------------------------7Reset---- ----------------------------------------------------------------------7Connect With Your Mobile Device ----------------------------------7Pairing Your Weather Station ---------------------------------------7Settings -------------------------------------------------------------------8View Current Readings -----------------------------------------------9View History Readings -----------------------------------------------9Optional Sensor For Additional Information --------------------10Precautions -----------------------------------------------------------------10Specications --------------------------------------------------------------11About Oregon Scientic ------------------------------------------------11EU-Declaration of Conformity ----------------------------------------11Disposal Information for Users --------------------------------------12FCC Statement-------------------------------------------------------------12Declaration of Conformity -------------------------------------------- 13RAR213HGX-Manual-EN-R8.indd   2 2018/6/12   下午2:59
EN3INTRODUCTIONThank you for selecting our Oregon ScienticTM Weather@Home Thermo Plus Bluetooth-enabled Thermo-Hygro Monitor, which has changeable display on indoor and outdoor temperatures and humidity. NOTE  Please keep this manual handy as you use your new product. It contains practical step-by-step instructions, as well as technical specications and warnings you should know about.OVERVIEWFRONT VIEW1.  Outdoor channel selected2.  : remote sensor reception indicator3.  : outdoor remote sensor battery low4.  Outdoor humidity reading (current / MAX / MIN)5.  Indoor temperature reading (current / MAX / MIN)6.  : BLE connection indicator7.  : main unit battery low8.  Ice alert LED indicator9.  MODE: change settings / display; search remote sensor10. MEM: view current, maximum and minimum temperature / humidity11. LIGHT: activate backlight for 5 seconds12.   : decrease value of the settings; select outdoor channels; deactivate pairing mode13.   : increase value of the settings; select outdoor channels; activate pairing mode14. AM/PM : morning/afternoon MD/DM/Yr: calendar / clock with weekday (hour : minute with second display)15. Indoor humidity reading (current / MAX / MIN)16. Outdoor temperature reading (current / MAX / MIN)RAR213HGX-Manual-EN-R8.indd   3 2018/6/12   下午2:59
4ENREAR VIEW RESE TC F    1.  RESET: reset the unit to default settings2.  °C / °F: select temperature unit3.  Battery compartmentREMOTE SENSOR (THGN132N)      1       23451.  LED status indicator2.  Wall mount hole3.  Battery compartment4.  RESET hole5.  CHANNEL switchUSEFUL REFERENCE Visit our website            www.oregonscientic.com to learn more about the compatible sensors.GETTING STARTEDINSERT BATTERIES1.  Remove the battery compartment.2.  Insert the batteries, matching the polarities (+/-).3. Press RESET after each battery change.RAR213HGX-Manual-EN-R8.indd   4 2018/6/12   下午2:59
EN5 LOCATION MEANINGClock area Main unit batteries lowOutdoor temperature area Sensor batteries lowREMOTE SENSORThe main unit can collect data from up to 5 sensors.To set up the sensor:1.  Open the battery compartment.2.  Select a channel then press RESET.3.  Close the battery door.4.  Place the sensor within 98 ft (30 m) of the main unit using the table stand or wall mount.TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 5 ft (1.5 m) and which can shield it from direct sunlight or wet conditions for an accurate reading.  1.5 m (5 ft)NOTE  Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures       below freezing.SENSOR DATA TRANSMISSIONTo search for a sensor:•  Press and hold   and MODE at the same time for      2 seconds.To auto-scan among sensors:The main unit can search for the sensor(s) automatically. The temperatures will be displayed automatically in sequential order.The sensor reception icon in the remote sensor area shows the status:ICON DESCRIPTIONMain unit is searching for sensor(s).A channel has been found.The sensor cannot be found.TIP The transmission range may vary depending on many factors. You may need to place the sensor(s) in different locations to get the best result(s). RAR213HGX-Manual-EN-R8.indd   5 2018/6/12   下午2:59
6ENCLOCKMANUALLY SET CLOCK1.  Press and hold MODE for 2 seconds to enter the setting mode.2.  The settings order is: 12/24 hour format, hour, minute, year, calendar format (day-month / month-day), month, day and language.3. Press   or   to change the settings.4. Press MODE to conrm.The language options are English (E), German (D), French (F), Italian (I), and Spanish (S).To select display mode:Toggle MODE to choose among clock with seconds / clock with weekday / calendar.TEMPERATURE AND HUMIDITYTo select temperature unit:1.  Open the battery compartment. 2. Select °C or °F for temperature readings by a pin or the top of a pen. 3.  Close the battery door.To select an outdoor sensor’s reading:•  Toggle   or   to select your desired sensor channel.To auto-scan among sensors:1.  Press and hold   and MEM at a time for 2 seconds to enable auto-scan function for all  5 channels. The temperature will be displayed automatically in sequential order for 3 seconds each.2.  To end, press   or   .To display current, minimum and maximum records of the day from a selected sensor:•  Toggle MEM.To clear the records:•  Press and hold MEM for 2 seconds.NOTE  The record will also be cleared once the batteries are removed from the main unit.ICE WARNINGIf the channel 1 sensor falls from 37°F to 28°F (3°C to -2°C), LED indicator   will ash, and will stop ashing once the temperature is out of this range.•  To disable the ice alert warning, press   and   at the same time. •  The ice warning detection will restart once the temperature falls out of 37°F to 28°F (3°C to -2°C), and will then trigger the ash again when the temperature falls into this range.RAR213HGX-Manual-EN-R8.indd   6 2018/6/12   下午2:59
EN7NOTE  As ice alert is only applicable to channel 1, to prevent ashing of LED, select other channels on outdoor sensor.BACKLIGHTPress LIGHT to activate backlight for 5 seconds.RESET•  Open the battery compartment. •  Press RESET to return to the default settings by a pin or the top of a pen.•  Close the battery door.CONNECT WITH YOUR MOBILE DEVICEYou can remotely set the weather station and read the weather information through Bluetooth®v4.0 using your mobile device with the downloaded application from the Apple Store. To quickly nd the application, type ‘Weather@Home’ as keyword in the search engine. Ensure your mobile device is compatible with iOS 5 or Android 4.3 with Bluetooth®v4.0 PAIRING YOUR WEATHER STATIONFirst of all, you need to pair your weather station with your mobile device.   will ash on the screen of the weather station while pairing and be on after successful pairing. •  Press and hold   for 2 seconds to enable a pair-up for the main unit for 30 seconds.•  Press and hold   for 2 seconds to disable a pair-up mode.          1. Tap   to enter SETTINGS screen.2.  Tap on STATION area. 3. Tap Pair Up. Searching… displays. If you want to cancel the pairing, tap Cancel. 4.  Once the pairing is successful, it will return to  STATION screen. RAR213HGX-Manual-EN-R8.indd   7 2018/6/12   下午2:59
8EN5.  Tap on each channel to rename it. (Up to 20 characters including space are allowed). Tap   if completed. Tap   to exit. To remove sensor:To remove any sensor from the weather station, Tap Remove station on STATION screen, all the sensors will be removed at the same time. To reposition the sensors on screen: 1. On STATION screen, tap  . 2.  Press and hold   at the right side of a sensor. Drag it to your desired position. 3. Tap   to conrm.SETTINGSYou can set your weather station through the application, such as measurement units. The settings are as follows:•  Temperature •  Barometric (with optional BTH sensor)•  Rainfall (not available in RAR213HGX)•  Wind speed (not available in RAR213HGX)•  Altitude (not available in RAR213HGX)•  Show unavailable sensor•  Automatically sync time•  Show sea level pressure (not available in RAR213HGX)          To select the measurement unit:1. Tap   to view the measurement unit options. 2.  Tap on your desired unit. 3. Tap   to go back to the previous screen.        RAR213HGX-Manual-EN-R8.indd   8 2018/6/12   下午2:59
EN9VIEW CURRENT READINGSYou can directly view all the weather readings from different sensors through the application at a time. The readings are in HOME screen.NOTE   If low battery icon    displays on the screen, please replace the batteries for the corresponding device.         To show unavailable sensor: If the sensor is out of range, the readings are interrupted and -- (dash mode) displays on the screen. If you do not want to show the unavailable sensor: •  On SETTINGS screen, touch and slide the button to right to turn on the function, or sliding to left to turn     it off. To automatically synchronize time: Time and date on your weather station could be automatically synchronized by your mobile device.•  On SETTINGS screen, touch and slide the button to right to turn on the function, or sliding to left to turn  it off. VIEW HISTORY READINGSYou can view history through the application. The history could also be presented in graphs (past 24 hours or past 7 days). To view the history:1.  Tap on your desired sensor area on the screen. 2. Tap       to select your desired data or tap to sort the data by date.      RAR213HGX-Manual-EN-R8.indd   9 2018/6/12   下午2:59
10ENOPTIONAL SENSOR FOR ADDITIONAL INFORMATIONBy applying the optional sensor (Model: BTH Sensor) at a time, you can also view the following information using your mobile device.•  Weather Forecast •  Air PressureUSEFUL REFERENCE The optional sensor (Model: BTH Sensor) can be purchased from Oregon Scientic.PRECAUTIONS•  Do not subject the unit to excessive force, shock, dust, temperature or humidity.•  Do not cover the ventilation holes with any items such as newspapers, curtains etc.•  Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.•  Do not clean the unit with abrasive or corrosive materials. •  Do not tamper with the unit’s internal components. This invalidates the warranty.•  Only use fresh batteries. Do not mix new and old batteries.•  Images shown in this manual may differ from the actual display.•  When  disposing  of  this  product,  ensure  it  is collected separately for special treatment and not as household waste.•  Placement  of this  product  on certain  types  of wood may result in damage  to its nish for which Oregon Scientic will not be responsible. Consult the furniture manufacturer's care instructions for information.•  The contents of this manual may not be reproduced without the permission of the manufacturer.•  Do not dispose old batteries as unsorted municipal waste.  Collection of such waste separately for special treatment is necessary.•  Please  note  that  some  units  are  equipped  with a battery safety strip. Remove the strip from the battery compartment before rst use.NOTE The technical specications for this product and the contents of the user manual are subject to change without notice. To download an electronic version of the user manual, please visit                 http://global.oregonscientic.com/customerSupport.php.NOTE  Features and accessories will not be available in all countries.  For more information, please contact your local retailer.RAR213HGX-Manual-EN-R8.indd   10 2018/6/12   下午2:59
EN11SPECIFICATIONSTYPE DESCRIPTIONMAIN UNITL x W x H 135.6 x 73 x 51.2 mm 5.34 x 2.87 x 2.02 inWeight 183g (6.46 ounces) include batteryTemperature range -5°C to 50°C (23°F to 122°F)Humidity range 25% - 95%Power 2 x UM-3 (AA) 1.5V batteriesTemperature range for ice alert 3°C to -2°CREMOTE UNIT (THGN132N)L x W x H 50 x 22 x 96 mm(1.97 x 0.87 x 3.78 in)Weight 62g (2.22 ounces) without batteryTransmission range 98 ft (30 m) unobstructedSignal frequency 433 MHZTemperature range -20°C to 60°C (-4°F to 140°F)Humidity range 25% - 95%Power 1 x UM-3 (AA) 1.5 V batteryABOUT OREGON SCIENTIFICVisit our website www.oregonscientic.com to learn more about Oregon Scientic products.For any inquiry, please contact our Customer Services at info@oregonscientic.com.Oregon Scientic Global Distribution Limited reserves the right to interpret and construe any contents, terms and provisions in this user manual and to amend it, at its sole discretion, at any time without prior notice. To the extent that there is any inconsistency between the English version and any other language versions, the English version shall prevail.EU-DECLARATION OF CONFORMITYHereby  the  manufacturer,  Oregon  Scientic  Global Distribution Limited, declares that  the radio equipment type Weather@Home Thermo Plus Bluetooth-enabled Thermo-Hygro  Monitor  (Model:  RAR213HGX)  is  in compliance with 2014/53/EU Directive. The full text of the EU Declaration of Conformity is available at the following internet address: http://global.oregonscientic.com/customerSupport.phpCOUNTRIES RED APPROVED COMPLIEDAll EU countries, Switzerland   CH                                              and Norway    NRAR213HGX-Manual-EN-R8.indd   11 2018/6/12   下午2:59
12ENDISPOSAL INFORMATION FOR USERSPursuant to and in accordance with Article 14 of the Directive 2012/19/EU of the European Parliament on waste electrical and electronic equipment (WEEE), and pursuant to and in accordance with Article 20 of the Directive 2013/56/EU of the European Parliament on batteries and accumulators and waste batteries.The barred symbol of the rubbish bin shown on the equipment indicates that, at the end of its useful life, the product must be collected separately from other waste.Please note that the batteries/rechargeable batteries must be removed from the equipment before it is given as waste. To remove the batteries/accumulators refer to the specications in the user manual. Therefore, any products that have reached the end of their useful life must be given to waste disposal centers specializing in separate collection of waste electrical and electronic equipment, or given back to the dealer when purchasing a new WEEE, pursuant to and in accordance with Article 14 as implemented in the country.The adequate separate collection for the subsequent start-up of the equipment sent to be recycled, treated and disposal of in an environmentally compatible way contributes to preventing possible negative effects on the environment and health and optimizes the recycling and reuse of components making up the apparatus.Abusive disposal of the product by the user involves application of the administrative sanctions according to the laws in force.FCC STATEMENTThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interferenceWARNING   Changes  or  modications  to  this  unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.NOTE  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the RAR213HGX-Manual-EN-R8.indd   12 2018/6/12   下午2:59
EN13interference by one or more of the following measures:•  Reorient or relocate the receiving antenna.•  Increase  the  separation  between  the  equipment  and receiver.•  Connect  the  equipment  into  an  outlet  on  a circuit different from that to which the receiver is connected.•  Consult  the  dealer  or  an  experienced  radio  /  TV technician for help.DECLARATION OF CONFORMITYThe following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at www.oregonscientic.com), or on the warranty card for this product) for all inquiries instead.WeName:     Oregon Scientic Inc.Address:    Brea Corporate Park    3020 Saturn St. Suite 200    Brea, CA 92821Telephone No.:   1 (888) 950-8889declare that the product Product No.:  RAR213HGXProduct Name:  Weather@Home Thermo     Plus Bluetooth-enabled    Thermo-HygroManufacturer:  Oregon Scientic     Global Distribution LimitedAddress:   Block C, 9/F, Kaiser Estate,         Phase 1, 41 Man Yue St.,        Hung Hom, Kowloon,     Hong Kongis in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.RAR213HGX-Manual-EN-R8.indd   13 2018/6/12   下午2:59