ILSUNGKOREA ISK Home Security System ( Keypad ) User Manual
ILSUNGKOREA Co. LTD. Home Security System ( Keypad )
User Manual
1. Basis composition Item Product explanation Main Appliance that control all functions of Time24 Keypad External Appliance that input all functions of Time24 by wireless PIR Sensor Appliance that sense object that move shooting permanent domicile outer line and notify wireless to main frame Door Sensor Appliance that sense that get closed with inquiry ten rims and notify wireless to main frame Siren Appliance that inform situation by sound and light Adaptor Appliance that supply entire in Time24 main frame -1- 2. Point to observe when establish 1. 2. 3. Install together main frame and telephone line, power and do not hide main frame front top portion Mike. Install keypad according to user's use position on main entrance inside. Is room that increase at PIR sensor. Establish in position that can sense invader's anticipation transfer path. ¢ ÁCaution(PIR sensor & Door sensor) (1) To see glass window outside for malfunction prevention at PIR Sensor, do not establish.Window establishes as do not look (2) If stove and air conditioner are operated or are windward from outside because window is unclosed, there is malfunction worry. Put out stove and air conditioner and close window and prevent malfunction at TIME24's operation (3) User who breed pet establishes as pet does not enter in perception sphere at PIR sensor. Example • As is not sensed about 50 Cm in the floor, control PIR sensor. • When go out, move pet to place that there is no PIR sensor. 4. 5. 6. Establish, and do to face department of liberal arts do leader switch in fixed place and magnetic switch that visit on window, entrance at door sensor and establish by 20mm within. Siren establishes to conquer invader at the same time information on emergency outside so that outsider may look well from outside by purpose, establish in place that do not take rain. Because Time24 uses radio, area that electromagnetic waves are serious with computer, cordless, under high-tension wire keeps schedule distance -2- 3. Product description 1. T_MAIN Arm Lamp Disarm Lamp input Lamp RESET switch Input switch dipswitch Tel line Adaptor Power Source Telephone Item Description Item Description Power Source DC12V Form Tone / Pulse Stand by Current 40mA Frequency 447.3MHz Operating Current Siren OFF 100mA Siren ON 250mA Sensitivity -120dBm Backup Battery DC6V 700mA Wire output D/C 12V 50mA BELOW Isolation Resistor TEL.LINE 2M§ ÙOVER Wire input NO or NC Point of contact input Storage Temperature -20 ~ 80 degree Power failure stand by 12 hours Operating Temperature 0 ~ 60 degree External (mm) W146 X H210 X D30 Sound power 110dB Weight 433g Internal Siren -3- 2. T_KEYPAD Item Description Item Description Power Source DC6V AA Battery 4ea Operating Temperature 0 ~ 60 degree Frequency 447.3MHz Stand by Current 30§ Ë Operating Current 100mA External (mm) W160 X H110 X D33 Storage Temperature -20 ~ 80 degree Weight 433g -4- 3. T_PIR (1) User mode (2) OFF (3) Test mode Item Description Item Description Power Source DC 4.5V AA Battery 3ea Frequency 447.3MHz Stand by Current 40§ Ë Storage Temperature -20 ~ 80 degree Operating Current 35mA Operating Temperature 0 ~ 60 degree Sensing Range Up and down 45 degree Left and right 110 degree External (mm) W65 X H110 X D40 Sensing Detection 25 ~ 45 degree motion Weight 120 g Sensing Estimated Range 7 – 10 m -5- 4. T_DOOR (1) Magnetic (2) lead switch (3) Door main (3) (1) (2) Item Description Item Description Power Source DC4.5VAA battery 3ea Frequency 447.3MHz Stand by Current 15 § Ë Storage Temperature -20 ~ 80 degree Operating Current 35mA Operating Temperature 0 ~ 60 degree Sensing Method magnetic / lead switch External (mm) W64 X H98 X D20 Sensing Range 20mm below Weight 180g -6- 5. Siren Establish in position that can inform emergency situation on outside. Item Description Item Description Power Source DC12V Sound power 120dB Stand by Current Storage temperature -40 ~ 80 degree Operating Current 250mA Operating temperature -10 ~ 60 degree Lamp Pilot lamp 2ea External (mm) W73 X H122 X D40 Sound Power Piezo Weight 108g 6. Adaptor Connect in household (AC120V) power and insert on main frame backside. Item Description Item Description Power Source AC 120V Maximum Current 500mA Power Supply 12V Storage Temperature -40 ~ 80 degree Input Current 10mA Operating Temperature -10 ~ 70 degree -7- 7. Emergency Button Emergency button is function that inform situation by emergency contact when crisis situation happens with emergency patient occurrence and outsider invasion in Time24 establishment place. Operation confirmation lamp Push Button Item Description Power source DC12V A23 Stand by current Operating current 35mA Frequency 447.3MHz Operating temperature 0 ~ 60 degree External W33 X H45 X D12 Weight 21.5g -8- 4. INPUT METHOD No Keypad MOD + * + 3 + 1 + SET + 1 telephone number input + SET button push inputed MOD + * + 3 + 2 + SET + 2 telephone number input + SET button push inputed MOD + * + 3 + 3 + SET + 3 telephone number input + SET button push inputed MOD + * + 3 + 4 + SET + 4 telephone number input + SET button push inputed MOD + * + 3 + 5 + SET + 5 telephone number input + SET button push inputed MOD + * + 3 + 6 + SET + 1 telephone number input + SET button push inputed MOD + * + 3 + 7 + SET + 2 telephone number input + SET button push inputed MOD + * + 1 + 1 + SET + 1 sensor on inputed MOD + * + 1 + 2 + SET + 2 sensor on inputed MOD + * + 1 + 3 + SET + 3 sensor on inputed MOD + * + 1 + 4 + SET + 4 sensor on inputed MOD + * + 1 + 5 + SET + 5 sensor on inputed MOD + * + 1 + 6 + SET + 6 sensor on inputed MOD + * + 1 + 7 + SET + 7 sensor on inputed MOD + * + 1 + 8 + SET + 8 sensor on inputed MOD + * + 0 + 1 + SET 1 Emergency push inputed MOD + * + 0 + 2 + SET 2 Emergency push inputed MOD + * + 0 + 3 + SET 3 Emergency push inputed Password (keypad) Register MOD + # + 2 + SET +password input + set button push inputed Password (main) Register MOD + * + 2 + SET +password input + set button push inputed Voice record MOD + * + 4 + set button push inputed Voice playback MOD + * + 5 + set button push inputed Delay time appointment MOD + * + 3 + 8 + SET + 01-99 + SET inputed Main register MOD + * + 0 + 0 + Press input button of main frame + set button push inputed Contact input method at invader occurrence input method at emergency situation (At emergency button use) Sensor input (PIR sensor or Door sensor) Emergency button input method -9- ARS ment Remark Arm / Disarm 5. FCC Requirement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interface, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION : Any changes or modifications in construction of this device which are not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. - 10 -
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 10 Creator : Microsoft PowerPoint Create Date : 2003³â 3¿ù 31ÀÏ Monday 4:35:12 ¿ÀÈÄ Title : ¿µ¹®»ç¿ë¼³¸í¼12 Author : ±è¼®Áø Producer : Acrobat PDFWriter 3.0 for Windows Subject :EXIF Metadata provided by EXIF.tools