ILSUNGKOREA ISR Home Security System ( Emergency Button) User Manual

ILSUNGKOREA Co. LTD. Home Security System ( Emergency Button)

User Manual

1. Basis composition654321Appliance that control all functions of Time24MainExternalProduct explanationItemAppliance that supply entire in Time24 main frameAdaptorAppliance that inform situation by sound and lightSirenAppliance that sense that get closed with inquiry ten rims and notify wireless to main frameDoor SensorAppliance that sense object that move shooting permanent domicile outer line and notify wireless to main framePIR SensorAppliance that input all functions of Time24 by wirelessKeypad1 2  3 4  5 6 -1 -
1. Install together main frame and telephone line, power and do nothide main frame front top portion Mike.2. Install keypad according to user's use position on main entranceinside.3. Is room that increase at PIR sensor. Establish in position that cansense invader's anticipation transfer path.¢Á Caution(PIR sensor & Door sensor)(1)  To see glass window outside for malfunction prevention at PIR Sensor, do not establish.Window establishes as do not look(2)  If stove and air conditioner are operated or are windward from outsidebecause window is unclosed, there is malfunction worry.Put out stove and air conditioner and close window and preventmalfunction at TIME24's operation(3)  User who breed pet establishes as pet does not enter in perceptionsphere at PIR sensor.Example•As is not sensed about 50 Cm in the floor, control PIR sensor.•When go out, move pet to place that there is no PIR sensor.4. Establish, and do to face department of liberal arts do leader switch in  fixed place and magnetic switch  that visit on window, entrance at door sensor and establish by 20mm within.5. Siren establishes to conquer invader at the same time information onemergency outside so that outsider may look well from outside bypurpose, establish in place that do not take rain.6. Because Time24 uses radio, area that electromagnetic waves are serious with computer, cordless, under high-tension wire keeps schedule distance2. Point to observe when establish-2 -
3. 3. Product descriptionProduct description1. T_MAIN433gWeightSound power 110dBInternalSirenW146 X H210 X D30External (mm)0 ~ 60 degreeOperatingTemperature12 hoursPower failure stand by-20 ~ 80 degreeStorageTemperatureNO or NC Point of contact inputWire inputTEL.LINE 2M§Ù OVERIsolationResistorD/C 12V50mA BELOWWire outputDC6V 700mABackupBattery-120dBmSensitivitySiren OFF 100mASiren ON   250mAOperatingCurrent447.3MHzFrequency40mAStand byCurrentTone / PulseFormDC12VPowerSourceDescriptionItemDescriptionItemRESET switchInput switchTel lineTelephoneAdaptorPower SourcedipswitchArm LampDisarm Lampinput Lamp-3 -
433gWeight-20 ~ 80 degreeStorageTemperatureW160 X H110 X D33External (mm)100mAOperating Current447.3MHzFrequency30§ËStand byCurrent0 ~ 60 degreeOperatingTemperatureDC6V AA Battery 4eaPowerSourceDescriptionItemDescriptionItem-4 -2. T_KEYPAD
3. T_PIR7 –10 mSensingEstimated Range120 gWeight25 ~ 45 degree  motionSensingDetectionW65 X H110 X D40External (mm)Up and down 45 degreeLeft and right 110  degreeSensingRange0 ~ 60 degreeOperatingTemperature35mAOperatingCurrent-20 ~ 80 degreeStorageTemperature40§ËStand byCurrent447.3MHzFrequencyDC 4.5V AA Battery 3eaPowerSourceDescriptionItemDescriptionItem-5 -(1) User mode(2)   OFF (3) Test mode
4. T_DOORDescriptionItemDescriptionItem180gWeight20mm belowSensingRangeW64 X H98 X D20External (mm)magnetic / lead switchSensingMethod0 ~ 60 degreeOperatingTemperature35mAOperatingCurrent-20 ~ 80 degreeStorageTemperature15 §ËStand byCurrent447.3MHzFrequencyDC4.5VAA battery 3eaPowerSource(3)(2)(1)-6 -(1) Magnetic(2) lead switch(3) Door main
5. SirenEstablish in position that can inform emergency situation on outside.108gWeightPiezoSoundPowerW73 X  H122 X D40External (mm)Pilot lamp 2eaLamp-10 ~ 60 degreeOperating temperature250mAOperatingCurrent-40 ~ 80 degreeStorage temperature-Stand byCurrent120dBSound powerDC12VPower SourceDescriptionItemDescriptionItem-7 --10 ~ 70 degreeOperatingTemperature10mAInputCurrent-40 ~ 80 degreeStorageTemperature12VPowerSupply500mAMaximumCurrentAC 120VPowerSourceDescriptionItemDescriptionItemConnect in household (AC120V) power and insert on main frame backside.6. Adaptor
7. 7. Emergency ButtonEmergency ButtonEmergency button is function that inform situation by emergency contact when crisis situation happens with emergency patientoccurrence and outsider invasion in Time24 establishment place.W33 X H45 X D12External21.5gWeight0~60 degreeOperating temperature447.3MHzFrequency35mAOperating current-Stand by currentDC12V A23 Power sourceDescriptionItemPush Button-8 -Operation confirmation lamp
4. INPUT METHOD INPUT METHOD inputedMOD  +  #  + 2  + SET +password input + set button push1Password (keypad)RegisterinputedMOD  +  *  + 2  + SET +password input + set button push2Password (main)RegisterinputedMOD  +  *  + 4 + set button push1Voice recordinputedMOD  +  *  + 5 + set button push1Voice playbackArm /Disarm inputedMOD  +  *  + 3 + 8 + SET + 01-99 + SET1Delay time appointmentinputedMOD  +  *  + 0 + 0 + Press input button of main frame + set button push1Main registerinputedMOD  +  *  + 0 + 3 + SET   3 Emergency push3inputedMOD  +  *  + 0 + 2 + SET   2 Emergency push2inputedMOD  +  *  + 0 + 1 + SET   1 Emergency push1Emergency button input methodinputedMOD  +  *  + 1 + 8 + SET  +  8 sensor on8inputedMOD  +  *  + 1 + 7 + SET  +  7 sensor on7inputedMOD  +  *  + 1 + 6 + SET  +  6 sensor on6inputedMOD  +  *  + 1 + 5 + SET  +  5 sensor on5inputedMOD  +  *  + 1 + 4 + SET  +  4 sensor on4inputedMOD  +  *  + 1 + 3 + SET  +  3 sensor on3inputedMOD  +  *  + 1 + 2 + SET  +  2 sensor on2inputedMOD  +  *  + 1 + 1 + SET  +  1 sensor on1Sensor input(PIR sensor or Door sensor)inputedMOD  +  *  + 3 + 7 + SET  +  2 telephone number input + SET button push2inputedMOD  +  *  + 3 + 6 + SET  +  1 telephone number input + SET button push1input method at emergency situation(At emergency button use)inputedMOD  +  *  + 3 + 5 + SET  +  5 telephone number input + SET button push5inputedMOD  +  *  + 3 + 4 + SET  +  4 telephone number input + SET button push4inputedMOD  +  *  + 3 + 3 + SET  +  3 telephone number input + SET button push3inputedMOD  +  *  + 3 + 2 + SET  +  2 telephone number input + SET button push2inputedMOD  +  *  + 3 + 1 + SET  +  1 telephone number input + SET button push1Contact input method at invader occurrenceRemarkARS mentKeypadNo-9 -
This device complies with Part 15 of the FCC Rules. Operation issubject to the following two conditions: (1) this device may notcause harmful interface, and (2) this device must accept anyinterference received, including interference that may causeundesired operation.5. FCC Requirement-10 -CAUTION : Any changes or modifications in construction of thisdevice which are not expressly approved by the party responsiblefor compliance could void the user's authority to operate theequipment.