IMEDIPLUS DS3011A Electronic Stethoscope User Manual testreport DS301

IMEDIPLUS INC. Electronic Stethoscope testreport DS301

Users Manual

IMEDIPLUS INC. 510(k) Submission Electronic Stethoscope DS3011A Section 13 Document Title: Electronic Stethoscope DS3011A User Manual File Name: 002_Electronic Stethoscope DS3011A User Manual       DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 2 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23      Feature Auscultation for heart, Anterior/Posterior chest, neck, bowel, limbs arteries, veins and internal organs. Heart rate detection. Built-in barcode reader for 1D (One dimensional) barcode scanning. Real time recording and playing of auscultation sounds. Recording multiple sounds in one patient and up to 600 10-second auscultation sound tracks. Micro SD memory card for file transmission of auscultation sound tracks. Friendly design for operation with organ mapping oriented interface Clear acoustic performance With 24X auscultation sound amplify ability and 10 volume level adjustable. Ergonomic Design  Easy to use.  DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 3 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   Content 1. Introduction .................................................................................................................. 4 2. Safety Information ...................................................................................................... 4 2.1 Symbol Definitions ................................................................................................. 4 2.2 Important Safety Information .............................................................................. 6 3. Product Description ................................................................................................... 8 4. Intended Use ................................................................................................................. 9 5. Operator Profile ........................................................................................................... 9 6. Patient Privacy ............................................................................................................. 9 7. Instructions for Use ................................................................................................. 10 7.2 Insert Battery .......................................................................................................... 11 7.3 Position Headset ................................................................................................... 12 7.4 Adjust Headset for Comfort .............................................................................. 12 7.5 Function Buttons .................................................................................................. 13 7.6 OLED display shows information ................................................................... 15 7.7 Schematic of Menu Page.................................................................................... 16 7.8 Operation Description ......................................................................................... 16 8. PhonoMagics Use ..................................................................................................... 31 8.1 Main Recording Screen ...................................................................................... 33 8.2 Profile Screen ......................................................................................................... 34 8.3 Review Screen ....................................................................................................... 34 9. Assembly Parts List ................................................................................................. 36 10. Accessory Information ....................................................................................... 37 11. Mechanical Dimension ........................................................................................ 38 12. Cleaning ................................................................................................................... 39 13. Warranty ................................................................................................................... 39 14. Troubleshooting .................................................................................................... 40 15. Maintenance and Repair ..................................................................................... 41 16. Transportation, Storage, and Disposal ......................................................... 42 17. Organ Positions Correspond to Recorded File Name ............................. 43 18. Appendix: Guidance and Manufacturer’s Declaration ............................. 45 19. EMC Compliance ................................................................................................... 48      DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 4 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   1.  Introduction Thank you for choosing the IMEDIPLUS Electronic Stethoscope DS3011A.  This useful stethoscope will be a great aid in your auscultation.  It has several smart and friendly design, which makes it easy to use and properly fit the needs for users. The design included an easy-to-use interface that enable the users to approach the patient with one hand. Rapid identification of recording number and user’s identities and 2-step operation for marking the source of the sound make the valid label while you capture the sound signals.  The ear-tips are comfortable to wear with the soft texture. As well, it could provide a good tightness for reduction of environmental noise to offer a good sound quality for users.  IMEIDIPLUS  Electronic  Stethoscope  DS3011A  was innovated from a group of healthcare professionals. Therefore, the user experience is an important factor of designing  the  stethoscope.  We  appreciate  for  your  adoption  of  IMEDIPLUS DS3011A and look forward to your valuable feedback. 2.  Safety Information Please  read,  understand,  and  follow  all  safety  information  contained  in  these instructions prior to using this electronic stethoscope. Retain these instructions for future reference.  2.1 Symbol Definitions Explanation of Safety Markings and Symbols  Warning  Consult instructions for use. DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 5 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    Indicates Type BF Equipment: The equipment provides protection against electrical shock and electrical current leakage. Applied parts are considered to be the complete chest-piece with diaphragm.  For ESD sensitivity connector the testing exemption.  This  product  and  packing  does  not  contain  natural  rubber latex.  Temperature Limit  This product  contains electrical and  electronic components and must not be disposed of using standard refuse collection. Please consult local directives for disposal of electrical and electronic equipment.  This product uses wireless Bluetooth communication.  Explanation of Signal Word Consequences NOTICE Indicates  a hazardous situation, which,  if not  avoided,  may result in property damage. WARNING Indicates a hazardous situation, which, if not avoided, could result in minor injury and/or property damage.     DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 6 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   2.2 Important Safety Information NOTICE   To  reduce  the  risks  associated  with  environmental  contamination  follow applicable regulations in local when disposing of this stethoscope. Properly dispose of, or recycle, spent batteries.  No modification of this device is allowed. Use only authorized IMEDIPLUS service personnel to repair this electric stethoscope. If user modify by self, solely responsibility for the consequence.  The  DS3011A  is  MR  unsafe.  Do  not  use  the  DS3011A  in  Magnetic Resonance Imaging (MRI) environment.   WARNING  To reduce the risks associated with an incorrect result, personal injury and  equipment  damage,  stethoscope  shall  be  stored  and  operated  by medical professionals only as instructed in this manual.  To  reduce  the  risks  associated  with  infection  follow  all  cleaning  and disinfecting  instructions  included  in  this  manual.  Establish  and  follow  a cleaning and disinfecting schedule.  To reduce the risks associated with a damage of ear canal, please hold tight the device to avoid sudden falling and make sure that the soft sealing ear-tips are snapped firmly into position.    DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 7 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    WARNING  To reduce the risks associated with very strong electromagnetic fields, avoid using the stethoscope near strong radio frequency signals or portable and/or mobile RF devices. The stethoscope might be damaged. If you hear sudden  or  unexpected  sounds,  move  away  from  any  radio  transmitting antennas.  To reduce the risk associated with an electrical shock, do not use the stethoscope on patients without the stethoscope’s diaphragm cover in place.  DS3011A contains a Bluetooth Class 2 wireless data link. The maximum radio frequency field strength generated by the stethoscope is below three volts per  meter,  a  level that  is  considered safe  to use with other medical devices.  However,  audio,  video,  and  other  similar  equipment  may  cause electromagnetic  interference.  If  such  devices  are  encountered  and  cause interference, immediately move DS3011A away from that device and/or turn the Bluetooth feature OFF.  To  reduce  the  risks associated  with  a  damage of  user’s  eyes, do not looking into the illumination beam of barcode reader.  To reduce the risks associated with a damage of stethoscope, please put the device into the pocket of physician gowns to avoid sudden falling, when you put the device hanging on the neck.  Do not use the unauthorized accessories, which would be caused hazard. The accessories use only from IMEDIPLUS provided.  Do  not  immerse  the  stethoscope  in  a  liquid  or  subject  it  to  any sterilization process. The device might be damaged.  Before first use, battery must be charged continuously for at least 8 hours. Failure to do so may shorten the battery's lifetime.  Do  not  use  the  DS3011A  in  Magnetic  Resonance  Imaging  (MRI) environment.  Because  of  DS3011A  contain  conductive,  metallic  and magnetic materials. Those materials include headset, wire, connectors and inductors, which are assembled in DS3011A.          DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 8 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   3.  Product Description The IMEDIPLUS Electronic Stethoscope DS3011A picks up the sounds from the heart,  lung, anterior/posterior chest, abdomen,  neck,  limbs,  arteries, veins  and other internal organs from a patient’s body. After detection and amplification, the sounds are transferred to the user’s ears via an active speaker and passive sound tubes. It could also identify the recording number by 1-D barcode reader, indicate the sound location by intuitive keypad, and simultaneously record the sounds from different sites. The one-hand user interface includes a full-color OLED display and an intuitive keypad at the anterior part, a barcode reader at the posterior part, a chest-piece at the superior part, a tube connector for output of sounds at the inferior part, and a recording button at the left part. Sound processing is operated with the aid of a digital signal processor. In order to transmit sounds to the “PhonoMagics” APP, the stethoscope and device must be connected via Bluetooth, and in order to fully use certain functions, the mobile device must be connected to the internet via cellular data connection or Wi-Fi. The DS3011A uses a Bluetooth Class 2 wireless data link. The Bluetooth range will  be  reduced  when  objects  (walls,  furniture,  people,  etc)  are  between  the DS3011A and a paired mobile device. To improve Bluetooth connection, reduce the distance and/or allow a line of sight between the DS3011A and mobile device. It  is  highly  recommended  that  users  of  the  (PhonoMagics  Dashboard  and) PhonoMagics use device and networking security features to protect patient data created and stored using this software, in addition to security features embedded in  the  system.  Please  consult  your  institution’s  technical  services  to  implement appropriate security measures. The  DS3011A  could  also  exchange  audio  data  with  an  external  personal computing device using micro SD card. Every single audio file stored in micro SD card was labeled with the user’s ID, recording number and indicated position. And the recorded audio data can only be replayed by DS3011A, but cannot be replayed by personal computing device. The DS3011A does not incorporate any off-the-shelf (OTS) software. The DS3011A operates on one (1) NP-120 lithium battery with an included power management system to prolong the battery life. DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 9 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   4. Intended Use The IMEDIPLUS Electronic stethoscope DS3011A is intended for the detection, amplification and recording of sounds from the heart, lung, anterior and posterior chest, abdomen, neck, limbs, arteries, veins and other internal organs with selective frequency ranges. The stethoscope chest-piece is designed for application to child, adolescent and adult patients. It is used for any subject undergoing a physical examination and intended only for medical diagnostic purpose in clinic or hospital. 5. Operator Profile The IMEDIPLUS Electronic Stethoscope DS3011A is designed to be used by anyone who wishes to listen to sounds as described in the Intended Use section above. The user manual provides complete information on how to operate the DS3011A so that no additional operating training is required. 6. Patient Privacy The privacy of patient health information may be protected by state, federal, or international/foreign laws that regulate how such information can be used, stored, transmitted,  and  disclosed. The  IMEDIPLUS  system  employs  security features that are compliant with HIPAA policies. Third party access may be prohibited to such information without obtaining written authorization from the patient.  The user is fully responsible for understanding and following all laws that regulate storage, transmission, and disclosure of any electronic patient data through the use of software. If the user becomes unable to comply with a law or restriction that applies to use and disclosure of such data, the user should not proceed to collect or save such information. This application may require entry of individually identifiable health information in order to function. Records are stored and recalled through the use of patient name, date of birth, and/or patient ID #. By entering this information, the user assumes any  and  all  risks  of  and  liabilities  incurred  with  using  or  transmitting  such information.   DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 10 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    7. Instructions for Use Please  read  through  the  user  manual  carefully  before  using  the  product  and operate it according to the user manual. It is advised that you should keep this manual for reference anytime. 7.1 Stethoscope Interface    Chest-piece (Microphone) OLED Screen Keypad Audio Output eartube Connector Barcode Reader Micro SD Card Slot Recording Button DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 11 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    7.2 Insert Battery Insert one NP-120 lithium battery (provided in package) into the IMEDIPLUS Electronic Stethoscope DS3011A.  Unlock of the battery cap, and then remove the battery cap, as follows.     Insert the battery with correct direction, as follows.    Remount the battery cap, as follows.        DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 12 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    7.3 Position Headset The ear-tips should point in the forward direction as you insert them into your ear canals. When ear-tips are properly positioned, diaphragm will face towards your body, as follows.  The user can pull ear-tips away from the eartube to remove the ear-tips, as follows.  The user can push ear-tip firmly onto eartube to apply new ear-tips, as follows.  7.4 Adjust Headset for Comfort To reduce the spring tension in the headset, hold each eartube at the bend part near the ear-tips and gradually pull apart until fully extended (180 degrees), as follows. To increase  spring tension,  grasp  the headset with one hand  where the metal eartube  enter  the  plastic  tubing,  and  squeeze  until  the  plastic  tubing  on  one eartube touches the other. Repeat as necessary, as follows. Eartube Ear-tip Ear-tip Eartube Remove Ear-tip Apply Ear-tip DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 13 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23     Reduce Tension Increase Tension 7.5 Function Buttons    Power Button To turn on the device or enter the sleep mode.  Recording Button During  auscultation  (in  the  HOME  page),  press  recording  button  to  record auscultation sounds of 10 seconds.  Filter Modes Switch Number Keys Lock Button Filter Modes Switch (B/D/W) Power Button Four-way and OK Button Barcode Reader Button Organ Position Switch Anterior Chest / Posterior Chest Switch  Audio Output & Tube Connector Recording Button  DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 14 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   During auscultation (in the HOME page) and playback the recorded sound track, this  button  can  select  one  of  the  auscultation  filter  mode,  including “Bell”, “Diaphragm”, and “Wide” modes.  Number Keys During  auscultation  (in  the  HOME  page),  the  “Number”  keys  on  the  intuitive keypad illustrated with heart and lung are used to choose the auscultation position. For “DATE SET” page, Number keys are used to set the date and time.  Lock Button (Lock/Unlock Switch) During auscultation (in the HOME page), the “Lock” button is used to “lock” most of the function keys, besides Recording Button. When pressing the button again, you will “unlock” the locked status.  Four-way Button and OK Button (Red key)  The “Four-way” button is used for selection.  The “Right” and “Left” keys are used to enter or exit the pages.  The “Up” and “Down” keys are used to adjust the sound amplification level. Using the “Up” and “Down” can move the indicator upward and downward.  The “OK” button(Red key) is to set and confirm the selection item  Barcode Reader Button For one-dimensional barcode scanning.  Organ Position Switch The “Organ Position Switch” is used to change the organ positions among “Heart and Lung”, “Neck”, and “Bowel”.  A/P CHEST Image Switch (Anterior and Posterior Chest) A/P CHEST Image Switch is used to change the organ images between “Anterior Chest” and “Posterior Chest”.     DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 15 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   7.6 OLED display shows information     Volume Level Date and Time User’s ID Organ Position Auscultation Position (Red Point is Under Auscultation and Recording) Recording Tips  Heart Rate Auscultation Modes B/D/W Battery Status Key Lock Icon  Unlock Lock Micro SD Card Tip No micro SD Card Micro SD Card Full Blinking Recording Number Bluetooth DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 16 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   7.7 Schematic of Menu Page  7.8  Operation Description  Power Button (Switch On / Sleep Mode)   Press the “Power Button” continuously for 3 seconds to turn on the device or enter the sleep mode.   The device will automatically enter sleep mode after idling for 5 minutes.  The idle time can be defined by the user on the “Setup Page”. (Reference to the functions of this user manual.)  Password Setting   When  turn  on  the  device,  enter  the  password  to  log  in  to  the  device application. The default password for use is “000000”.   Create a personal secure 6-digit password by selecting “SETUP” option. DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 17 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   Navigate to the UPDATE PWD screen after selecting the “SETUP” option.  Next,  select  “UPDATE  PWD”  >  INPUT  PASSWORD.  Follow  the instructions on the screen to create and save a 6 -digit password. You will need to enter your PIN twice for verification purposes.                                 Detection of The Patient’s Heart Rate  Place the stethoscope close to the patient’s heart sound positions. Within 10 seconds, the screen will display the patient’s heart rate and the data will be updated every two seconds. The heart rate ranges from 30 bpm (beat  per  minute)  to  180  bpm  (beat  per  minute).  When  taking  the stethoscope away from the patient, the heart rate will display 000 within 5 seconds. IMPORTANT!  If  the  ambient  sound  is  too  noisy  or  the  measuring  position  is  incorrect, inaccurate heart rate may happen. WARNING: To avoid the damage of ears, do not tap hard or scratch the  chest-piece  with  diaphragm  while  wearing  the  eartips  with  the stethoscope powered on.  Organ Position   Using function keys to select the organ position.   Using number keys to select the auscultation position under auscultation and recoding.   Red point is the auscultation position under auscultation and recording (Indicated position)   Every  single  audio  file  stored  in  micro  SD  card  was  labeled  with  the indicated position.  Organ position switch among “Heart/Lung”, “Neck”, and “Bowel” DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 18 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23     Using  the  “Heart  /Lung”  organ position, it could be  quickly switched between “Heart” and “Anterior Chest” for the selection of organ position.     Organ Position Switch       is used to change the organ position among “Heart and Lung”, “Neck”, and “Bowel”. Press the key with image of “Heart” or “Anterior Chest” on the keypad to switch and select organ position DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 19 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    Organ position switch between “Anterior Chest” and “Posterior Chest”    Filter Mode Selection (B/D/W Modes) The stethoscope allows the users to select these three different filter modes (B/D/W modes) for diverse application to different clinical scenario. Which can emphasize the specific patient sounds of interest.  Using the “Bell” mode, the sound frequency below 390 Hz is amplified, and the sound frequency from 20 to 200 Hz is emphasized.  Using  the  “Diaphragm”  mode,  the  sound  frequency  below  630  Hz  is amplified, and the sound frequency from 100 to 500 Hz is emphasized.  Using the “Wide” mode, the sound frequency below 1000 Hz is amplified.    Press the function button           to switch the position to “Anterior Chest” or “Posterior Chest”.  When you pick up the sound of right upper lung filed at the front, you shall select the “Anterior Chest” area and then press the number key “4” which stands for “RUL(Right Upper Lobe) illustrated on the intuitive keypad.  When you pick up the sound of left upper lung filed at the back, you shall select the “Posterior Chest” area and then press the number key “4”  which stands for “LUL(Left Upper Lobe) illustrated on the intuitive keypad. Press function button          to select the filter mode. The “B” mode, “D” mode, and “W” mode will cycle in turn when you press this button. Bell Mode Diaphragm Mode Wide Mode DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 20 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    Real-time monitoring sound wave The stethoscope can show the sound wave on screen during hearing the sound in different mode.    Recording the Auscultation Sound  While recording the auscultation sound, every single audio file of the sound track  stored  in  the  micro  SD  card  will  be  labelled  with  recording  number (Identity),  user’s  ID  (Identity),  and  indicated  position.  The  user  could  also exchange audio data with an external personal computing device using the micro SD card (Maximum to 600, 10-second sound tracks)   Press  the  Recording  Button  to  record  the  auscultation  sound  for  10 seconds after selecting the auscultation position with recording number and user’s ID.   The recorded auscultation sound track will be saved in the micro SD card which can store up to 600 sound tracks. Don’t remove the micro SD card during recording.   To switch the mode to show the sound wave, press the “OK” button while listening the sound. 10 sec Recording Count  Press function button              to record the auscultation sounds. DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 21 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23     Playing Back a Sound Track When you enter the “MENU” page, selecting “PLAY” will help you enter the “PLAY LIST” page.    Press the Right Button to enter the “MENU” page and then press “OK” Button to enter the “PLAY LIST” page.  “PLAY LIST” provides the latest 50 sound tracks with auscultation position.   Press the “Up” or “Down” button to select the sound track which you want to play back. Then press the “OK” button to play the one you select.   The sound track you select could be transferred to the user’s ears via an active  speaker  and  passive  sound  tubes.  The  sound  track  will  loop continuously and demonstrate on the screen.   While listening the sound track, the sound can be listened in different filter mode by pressing the        button.    Press the “Left” button to stop playing the sound track and return to the “PLAY LIST” page.   Adjust Sound Amplification Level The  IMEDIPLUS  Electronic  Stethoscope  DS3011A  sound  level  could  be amplified  in  10  increments  up  to  24X  amplification  of  a  non-electronic (Cardiology-level) stethoscope. Level 0 is equal to silent mode. Level 10 is equal to 24X amplification of a non-electronic stethoscope. The greater the amplification, the more bars you will see on the screen.  Press the “Right” button to enter the “MENU” page. Press the “OK” button to enter the “PLAYLIST” page. The sound track you select will loop continuously and demonstrate on the screen when you enter the “PLAYBACK” page. MENU Page Playback Page PLAY LIST page DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 22 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23     Press the “UP” button to increase the volume level until the desired level is achieved.   Press the “Down” button to decrease volume level until the desired level is achieved.     Press the “UP” and “DOWN” button to adjust sound amplification level. The greater the amplification, the more bars you will see on the screen. Volume + Volume - DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 23 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    Lock /Unlock   Press the “Lock” Button to lock or unlock keypad to avoid inadvertently touching other keys during auscultation.   When the keypad is locked, only the “Recording Button” can be used.   Press  the  “Barcode  Reader”  button  to  set  the  user’s  ID (Identity) and recording number (Identity) Setting the user’s ID and recording number before you select the auscultation position and pick up the sound for clinical auscultation. Every single audio file of  sound  track  will  be  labelled  with  the  recording  number,  user’s  ID,  and auscultation position for digital sound track database storage and build-up. It will be helpful to follow up your patient with valid auscultation records with lots of correlated clinical evidence for advanced study and personalized care. After your successful setting, both of the user’s ID and recording number will show on the “Home” page as following illustration.  Setting the recording number  On the “HOME” page, press the “Barcode Reader” button could identify the recording number. After your setting, the recording number will show in the screen as follows. Unlocked Locked Press function button       to lock or unlock keypad. DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 24 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    WARNING: Looking at the beam light of barcode reader is prohibited to avoid damage to your eyes. IMPORTANT! •  The recording number is the series number of clinic or hospital, it did not include any patient’s personal information.  Setting the user’s ID We could set the user’s ID after going to the “MENU” page and please select “USER  ID SET”  to  go  to the “USER  ID  SET” Page.  You  can  use Barcode reader to set the user’s ID. After your setting, the user’s ID will show in the screen as follows.       Recording number Press the “Barcode Reader” button         to identify the recording number. User’s ID Press the “Barcode Reader” button        to read and set the “User’s ID” for the following auscultation.  Select USER ID SET  DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 25 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   WARNING: Looking at the beam light of barcode reader is prohibited to avoid damage to the eyes. IMPORTANT! •  The 1D (one dimensional) barcode reader can only read the 1D (one dimensional) barcode. •  The barcode of the subject should be placed within the effective range of the red light emitted from the barcode reader.  •  Continuously reading the barcode of the subject may lead to failure. An interval of two seconds between one scan to the next scan is recommended. •  Symbologies: 1D (one dimensional) barcode types, such as Code128, UCC/EAN 128, Code 39, UPCA, UPCE, EAN8, EAN13, Codabar, Plessey, Code 93 and ISSN etc. can be support.    DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 26 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    Setting Date and Time  On the “DATE SET” page, using the number keys to set the current date and time is very significant. We will label the audio file with the date and time for storage and database build-up.   Set The Idle Time-Out before DS3011A Goes To Sleep Under the SLEEPING MODE In the SETUP Page. Set The Filter Option Group for the “BDW Switch” or the “BD Switch”. SLEEPING MODE: To avoid the possibility of the user forgetting to turn off the DS3011A or leaving it exposed to unauthorized personnel, the user can set an idle time-out that will automatically make the DS3011A go to sleep if the DS3011A is not used for a specified amount of time, including “2 MIN (2 minutes)”. “5 MIN (5 minutes)”, and “15 MIN (15 minutes)”.  FILTER Option Group: There are two filter option group. One group is “BDW” Switch, the other one group is “BD” Switch. Under the “BDW” switch group, the “B” mode filter, “D” mode filter, and “W” mode filter will cycle in turn as you press the “B/D/W Mode Switch” button. Under the “BD” switch, the “B” mode filter and the “D” mode filter will cycle in turn as you press the “B/D/W Mode Switch” button.  Set Date Press the “Right” button to enter the “MENU” page. Use the “Down” and “Up” button to control the indicator. When selecting the “Date SET” item, press the “OK” Button to enter DATE SET page. Use the “Four-Way” button to control the indictor with number keys for setting the date and time and then press the “OK” button to save your setting.  Select DATE SET DATE SET page Set Time DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 27 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23     Reset To Factory Setting  The stethoscope can be reset to factory setting by using “FACTORY RESET”. After entrance the “FACTORY RESET” page, you can select to restore the factory setting if you select “YES” and press the “OK” button. This function can help you default the unexpected condition and reset to factory setting.          Select “SETUP” in the “MENU” page to enter the “SETUP” page. Set  up  “SLEEP  MODE” and “FILTER” group in the “SETUP” page. Press  the  “Right”  button  to enter the “MENU” page. Using  the  “Up”  and  “Down” buttons  to  move  the  indicator to  “FACTORY  RESET”  and press  the “OK” button to go to the “FACTORY RESET” page. If you do need to restore to factory  setting,  you  can select “YES” to reset. If not, you can select “NO” and go back to the “HOME” page Press  the  “Right” button to go to the “MENU” page. DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 28 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   Factory Default Setting Table Parameters Default Idle time of “Sleeping Mode” before going to sleep 5MIN (5 minutes) Filter mode group “BDW” group Auscultation organ position HEART Filter Mode B Mode Amplification level Level 5 Recording number Empty  User ID NULL   Product Information The  stethoscope  show  the  software  version  and  product  name  on  the “PRODUCT INFO” page.   Connection  First, enable Bluetooth on the selected mobile device. On the Android device go to Settings > Bluetooth > and tap the slider to turn Bluetooth ON. Then, navigate to the Menu screen by clicking on the top right tab “Connect” in the App. Navigate to Bluetooth menu, select the SSID (Bluetooth Media Access Control Address) and pair with the device. The mobile device is now ready to record sounds from the DS3011A. If Bluetooth pairing is unsuccessful, the Bluetooth mark will flash on the OLED Select  “PRODUCT  INFO” to  go  to  the  “PRODUCT INFO” page Press the “Right” button to go to the “MENU” page. The  “PRODUCT  INFO” page will show the software version,  product  ID  and Bluetooth  Media  Access Control  Address  on  the page. DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 29 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   screen of DS3011A and no sounds will be recorded. If the Bluetooth connection is successful the mark will keep in bright blue of the device.  System requirement The mobile app software can be used on ASUS ZenPad10 with Android™ 6.0 and greater than 30MB of free memory. DS3011A uses Bluetooth Class 2; mobile devices used must be compatible with Bluetooth Class 2. *ZenPad10 are registered trademarks of ASUS, Inc. *Bluetooth is a registered trademark of Bluetooth SIG, Inc.  Using The Micro SD Card To Transfer Audio Files To An External Device Removing the micro SD card from the electronic  stethoscope  can transfer auscultation sound tracks of audio files to an external device. IMPORTANT!  •  Please turn off the system before removing the micro SD card. •  Please do not delete the built-in files in the micro SD card arbitrarily. •  Having a backup of your DS3011A is helpful. When the SD card is full capacity, you need to take a copy of your SD card to an external computing device and then empty the SD card for the coming storage of audio files. •  For the stability of the operation, please backup and empty the micro SD card periodically as regular maintenance. •  In  addition  to audio files, do  not store  any other files  in order  to avoid unnecessary interference.    DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 30 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    Battery Power Indication Battery  life  is  indicated  by  an  icon  in  the  screen.  IMEDIPLUS  Electronic Stethoscope  DS3011A  has  a  rechargeable  2300mAh  NP-120  lithium-ion battery provides approximate 24 hours of continuous use. The battery power loss and the use of barcode reader are highly correlated. As the battery power decreases, the icon will change as follows:  80~100% Battery Power  60~80% Battery Power  40~60% Battery Power  15~40% Battery Power  0~15% Low Battery Power When the battery power is running out, the screen will display the “0~15% Low Battery Power” located on the right lower area of the screen to remind the user about the current state of the battery power. When the “0~15% Low Battery Power” displays in the screen, the user should replace the battery or charge the battery as soon as possible.  IMPORTANT! •  When  the  battery  is  completely  no  battery  power,  the  IMEDIPLUS Electronic  Stethoscope  DS3011A  will  automatically  turn  off.  All  the recorded  sound  tracks  and  the  settings  of  the  DS3011A  will be  saved before it turns off.  Charge the Battery Taking out the Battery from the electronic stethoscope and using the battery charger, which is one of the DS3011A accessories, to charge the battery.   Putting the adaptor plug into the battery charger, the charging indicator will display green.  When the battery is placed in the charger, the charger will begin to charge the battery   The  charging  indicator  will  display  the  charging  states.  Under  charging states, the indicator will display red. When the battery is fully charged, the screen will show a green light.  DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 31 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   WARNING:  Do  not  use  the  unauthorized  battery  and  charger  to prevent unexpected hazards IMPORTANT!  •  Please turn off the system before taking out the battery. •  Make sure the battery is placed correctly on the battery charger before charging the battery.  Other Operating Considerations   Operating  range  is  32ºF  to  104ºF  (0ºC  to  40ºC),  15  to  93%  relative humidity.   Maximum operating altitude is 2000m.   Maximum expected service life is 5 years.   Storage and transport range is -4ºF to 158ºF (-20ºC to 70ºC), 0 to 93% relative humidity.   To keep  the life of your electronic stethoscope, please avoid operating under extremely hot and extremely cold condition.    Don’s use solvents and oils to prevent unexpected hazards.   Remove  the  battery  if  the  electronic  stethoscope  will  not  be  used  for several months.   Failure to follow care and maintenance recommendations could result in damage  to  the  internal  components  of  the  IMEDIPLUS  Electronic Stethoscope DS3011A. Internal damage could cause malfunction of the product, ranging from a slight decrease in auditory response to complete failure of the product. If you experience any problems with the IMEDIPLUS Electronic Stethoscope DS3011A, do not attempt to repair it yourself. Please notify our customer service center for directions on shipping and receiving. 8.  PhonoMagics Use  Installation for Android system Open the Android App Store using a supported iPad model. Ensure that the device is connected to the internet. Follow the instructions to download the App and wait until it has finished installing.  Logging in DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 32 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   Open the PhonoMagics on the mobile device. When prompted, enter your existing password. The password is “000000” for factory setting.  Bluetooth Pairing Bluetooth must be enabled in the tablet’s Bluetooth settings in order to use Core with the PhonoMagics.  First, enable Bluetooth on the selected mobile device. On the Android device go to Settings > Bluetooth > and tap the slider to turn Bluetooth ON. Then, open the PhonoMagics and navigate to the PhonoMagics menu screen by clicking on  the top right tab “Connect” on the home screen. Navigate to Bluetooth menu, select the SSID (Bluetooth Media Access Control Address) and pair with the device.        The  mobile  device  is  now  ready  to  record  sounds  from  the  DS3011A.  If Bluetooth pairing is unsuccessful, the Bluetooth mark will flash on the OLED screen  of  DS3011A  and  no  sounds  will  be  recorded.  If  the  Bluetooth connection is successful the mark will keep in bright blue of the device.  Setting up a Password Create a secure 6-digit password by logging in to the application. Navigate to the Menu screen by selecting the icon on the top left of the Pad App home screen. DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 33 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   Next, select Change Password. Follow the instructions on the screen to create and save a 6 -digit password. You will need to enter your original password and new password twice for verification purposes.  Capture & Save Recordings using the Android App Open the PhonoMagics and log in. Ensure that the DS3011A Device is paired to the pad device (See Section 8). In  the  home  screen,  use  DS3011A  and  press  Recording  Button  to  being recording. The recording process will last 10 seconds. Once it is finished, the recording  process  will  stop  automatically.  When  recording  is  finished,  the home screen will appear another windows to select to save the recording or not. 8.1  Main Recording Screen The Main Recording Screen allows users to view audio data captured by DS3011A, begin the recording process, retrieve patient specific data, or adjust settings. Audio data is represented in real-time as a phonocardiogram. A period of recording is 10-second intervals.           Settings Connect to Device Search IMA File Change Password Connect Bluetooth connection button  Settings Connect to Device Search IMA File Change Password Connect Status Bluetooth connect or not. Audio waveform Retrieved from the DS3011A Organ Mark Indicate the listening position. DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 34 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   8.2  Profile Screen Selecting the Search IMA File icon on the main screen brings up the recording list and search bar. From this page, users may access previously assigned recordings or add a new recording to the patient’s record history.         8.3  Review Screen More information on a specific recording can be viewed by tapping on a recording listing. This screen displays a waveform of the recording, options to playback the sound, and notes. Notes may be added by any user with access to the patient’s profile.           Delete Delete the recording. Search Bar Search recording numbers  Recording List Recording Data Recording numbers, heart rate, filter mode, date and time. Organ Mark The location of sound. Audio waveform & Modify Recording Playback and stop. DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 35 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   IMPORTANT! The audio quality of the sounds play through the pad speaker or audio jack may not performed actual sounds quality, to hearing the best sounds quality, it is highly recommended that a DS3011A eartube is used to listen to the record sounds.      DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 36 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   9.  Assembly Parts List 1. DS3011A  Device:  It  consists  of  chest-piece  with  diaphragm,  screen,  intuitive keypad  and  eartube  connector  of  audio output.  2. DS3011A  Headset:  Including  eartube  , connector, and ear-tips   3. Micro SD Card 4. Rechargeable  Lithium-ion  Battery:  NP-120 2300mAh   5.  Battery Charger: Including Adaptor and Charger.  DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 37 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   WARNING:  Do  not  use  the  unauthorized  accessories  which  would lead  to  unexpected  hazards.  All  accessories  only  from IMEDIPLUS  provided  could  be  used.  For  more information,  please  refer  to  “Accessory  Information section”.  10. Accessory Information The following items can be purchased as a replacement for your device. Please contact our distributors or authorized service centers for inquiries. Part no  Part Name Q'ty B002011100002 Power adaptor  1 SET B002011101003 Battery Charger 1 SET B002028000002 Adaptor cable 1 EA A014063001026 Sanyo Li-ion Battery UF553450Z 1S2P 3.7V 2300mAh, Model:UF553450Z 1 SET B002032008001 SD Card 1 SET F0002005A1S00 Headset  1 SET B051052301016 DS301-SILICONE- Diaphragm 1 EA    DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 38 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   11. Mechanical Dimension Item Description Outline Dimensions (mm) Net weight L W H 1 Device  191.3 64.3 45.9 304 2 Rechargeable Lithium-ion Battery  53.5 35.5 11.5 55 3 Headset  660 135 25 107 4 Diaphragm   44 5 3 DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 39 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   12. Cleaning Cleaning of stethoscope should be done between each patient use. WARNING: To reduce the risk of infection, cleaning of stethoscope should be done between each patient use.  Cleaning the Chest-piece Under  normal  conditions,  it  is  unnecessary  to  remove  the  diaphragm  for cleaning.  The  diaphragm  can  be  cleaned  by  using  an  alcohol  wipe.  If necessary,  please  remove  the  diaphragm,  carefully  follow  the  instructions mentioned bellow.  Diaphragm Removal: With the diaphragm sided up, using a thumbnail to lift the underside portion of the diaphragm out of its designated groove, and peel off the chest-piece. The groove that holds the diaphragm in place can be cleaned by sliding the edge of an alcohol swab around the groove. All parts of the chest-piece can be wiped down with alcohol.  Diaphragm Reassembly: Once the diaphragm is completely dry, insert the diaphragm into the groove of the rim, starting at one point, and run your finger around the diaphragm until it is seated back in the groove.  Cleaning Other Parts of the Stethoscope Ear-tips, eartube and chest-piece can be wiped clean with alcohol. Ear-tips may be removed for the advanced cleaning and disinfection.  WARNING: Do not immerse the stethoscope in a liquid or subject it to any sterilization process. The device might be damaged.  13. Warranty Your IMEDIPLUS Electronic Stethoscope DS3011A is warranted against any defects in material and manufacture for a period of a year. If a material or manufacturing defect is discovered during the warranty period, repairs will be made without charge upon the return of the instrument to IMEDIPLUS, except in cases of obvious abuse or accidental damage.   DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 40 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   14. Troubleshooting Item Questions Answer 1. No “Powered”, after “Turn ON”. Please  check  battery  whether properly  installed,  and  then  try again after reinstall the battery. 2. No “Powered”, after “Turn ON”. Please  replace  a  new  one battery, and then try again after reinstall battery. 3. No  “auscultation  sound”,  after  “Turn ON”. Please  check  headset  whether properly  installed,  and  then  try again after reassembly headset. 4. No  “auscultation  sound”,  after  “Turn ON”. Please  use  the  “amplification level  control”  button  to  adjust amplification level properly. 5. The  screen  displays  “micro  SD  card read error”  , after “Turn ON” Check  the  micro  SD  card  is properly installed or damaged. If fails  after  you’re  trying,  please call local service for help. 6. The  screen  displays  “micro  SD  card read”   blinkingly. The  micro  SD  card  could  save the  maximum  amount  of  600 auscultation  sound  tracks. Please  remove  the  micro  SD card,  and  empty  the  micro  SD card  after  backup  the  sound tracks.  The  system  will  work normally  after  insert  the  micro SD card into the device again. 7. When  the  stethoscope  is  operating, the  system  will  shut  down automatically if you  remove or insert the micro SD card. In order to protect the data in the micro SD card, the stethoscope will  go  to  sleep  mode automatically  when  you  remove or insert the micro SD card. 8. The screen displays “FILE CHK ERR”, when the system entered PLAYBACK page. The  system  can  check  the integrity of  sound  file. If  the  file format is incorrect, please take-out the micro SD card and format it. 9. The  screen  displays  “DATE WARNING” after “Turn ON” This  stands  for  unsetting of  the date and the time. Please refer to the  section  "Setting  Date” DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 41 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   (setting date  section 6-8)  to  set date.  Item Questions Answer 10. The screen displays “ILLEGAL DATE” when you set the date. Please  make  sure  the  date  is legal. 11. After  the  barcode  reader  scanning, the screen displays empty or “Invalid symbol”. Please  make  sure  that  the subject’s  barcode  is  placed within the range of the red light of the barcode reader. Don’t move the  barcode  when  you  are scanning. Please  make  sure  that  the barcode  messages  don’t  have anyone of the symbols: ", *, /, :, ?, <, >, \ and |. 12. The  screen  displays  “KEY  Scanning Err” when you press the keypad. Please reinsert  the battery, and then  make  sure  the  error message disappears. 13. The  device  has  no  response  when you are operating the device. Please reinsert the battery, and then  make  sure the  device  has response  when  you  are operating. IMPORTANT! •  If you have tried all of the solutions to the questions and that still failed to solve your problem, please call local service branches for assistance. 15. Maintenance and Repair For  maintenance  or  repair  Services,  please  register  your  name,  physical address, e-mail address, and phone number with your IMEDIPLUS Electronic Stethoscope DS3011A. NOTICE:  No modification  of  this  device  is  allowed.  Use  only  IMEDIPLUS service personnel to repair this electric stethoscope. If user modify by  himself,  the  user  will  take  all  of  the  responsibility  for  the consequence. DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 42 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   If  you  have  any  questions  or  comments,  please  feel  free  to  contact IMEDIPLUS Customer Service Center. In the U.S.A: U.S. Agent Contact Name: Mr. JAMES WANG U.S. Agent Full Address: 31 Trillium Lane, San Carlos, California, 94070, UNITED STATES U.S. Agent Email: jwjwang5@gmail.com U.S. Agent Tel: +1-650-8629968 http://www.imediplus.com  In the Taiwan (R.O.C.): IMEDI PLUS Inc. Address: 2F, 12, ShengYi Rd. Sec. 2, Chupei City, Hsinchu County 30261, Taiwan (R.O.C.) Email: service@IMEDIPLUS.com Tel: +886-3-658-7700 Fax +886-3-658-9535 http://www.imediplus.com  16. Transportation, Storage, and Disposal  Transportation and Storage   General  transportation  of  the  unit  should  correspond  to  the  conditions outlined in the 'Other Operating Considerations' section of this manual.   The IMEDIPLUS Electronic Stethoscope DS3011A needs to be sent to an authorized  service  center  for  inspection  and  repair.  The  storage environment  conditions  must  be  follow  the  'Other  Operating Considerations' section of this manual.  Disposal You shall properly dispose of the DS3011A and follow the local regulations. The  Lithium-ion  battery  must  be  disposed  of  separately  or  recycled  from regular waste. NOTICE: To reduce the risks associated with environmental contamination, we need to follow the applicable regulations in local when disposing of this stethoscope. The Lithium-ion battery must be disposed of separately or recycled from regular waste.  DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 43 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   17. Organ Positions Correspond to Recorded File Name Organ Organ and Auscultation Position Indication Corresponding Recorded File Name File Name Descriptions Numeric Key Saved Name HEART   1 ##A HEART ##AAortic; ##PPulmonic; #SASecond Aortic;  ##TTricuspid; ##MMitral 5 ##P 8 #SA 0 ##T * ##M NECK   1 RUN NECK 1. The first character R/L means Right/Left; M means Middle. 2. The second character U/L means Upper/Lower; M means Middle. 3. The third character abbreviation “N” correspond to NECK organ. 4 RMN 7 RLN 3 LUN 6 LMN 9 LLN BOWEL   1 RUB BOWEL 1. The first character R/L means Right/Left; M means Middle. 2. The second character U/L means Upper/Lower; M means Middle. 3. The third character abbreviation “B” correspond to BOWEL organ. 2 MUB 3 LUB 4 RMB 5 MMB 6 LMB 7 RLB 8 MLB 9 LLB     DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 44 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   Organ Organ and Auscultation Position Indication Corresponding Recorded File Name File Name Descriptions Numeric Key Saved Name A-CHEST (Anterior-CHEST)   4 RUA A-CHEST 1. The first character R/L means Right/Left; M means Middle. 2. The second character U/L means Upper/Lower; M means Middle. 3. The third character abbreviation “A” correspond to A-CHEST organ 7 RMA # RLA 3 LUA 6 LMA 9 LLA P-CHEST (Posterior-CHEST)   4 LUP P-CHEST 1. The first character R/L means Right/Left; M means Middle. 2. The second character U/L means Upper/Lower; M means Middle. 3. The third character abbreviation “P” correspond to P-CHEST organ. 7 LMP # LLP 3 RUP 6 RMP 9 RLP     DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 45 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   18. Appendix: Guidance and Manufacturer’s Declaration Declaration – Electromagnetic Emissions The IMEDIPLUS Electronic Stethoscope DS3011A is intended for use in the electromagnetic environment specified below. The customer or the user of the DS3011A should assure that it is used in such an environment. Emissions test Compliance Electromagnetic environment –guidance RF emissions CISPR 11 Group 1 The DS3011A uses RF energy only for its internal  function.  Therefore,  its  RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class A The  DS3011A  is  suitable  for  use  in  all establishments  other  than  domestic  and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Harmonic emissions IEC 61000-3-2  Class A Voltage fluctuations/flicker emissions IEC 61000-3-3 Compliance  Declaration – Electromagnetic Immunity The IMEDIPLUS Electronic Stethoscope DS3011A is intended for use in the electromagnetic environment specified below. The customer or the user of DS3011A should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment–guidance Electrostatic discharge (ESD) IEC 61000-4-2 ± 6 kV contact ± 8 kV air ± 6 kV contact ± 8 kV air Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%. Electrical fast transient/ burst IEC 61000-4-4 ± 2 kV for power supply lines ± 1 kV for input/output lines ± 2 kV for power supply lines Not applicable Mains power quality should be that of a typical commercial or hospital environment. Surge IEC 61000-4-5 ± 1 kV differential mode  ± 2 kV common mode ± 1 kV differential mode Not applicable Mains power quality should be that of a typical commercial or hospital environment. Power frequency (50/60 Hz) magnetic field IEC61000-4-8 3 A/m  3 A/m The DS3011A power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 46 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    Declaration – Electromagnetic Immunity – Continued The IMEDIPLUS Electronic Stethoscope DS3011A is intended for use in the electromagnetic environment specified below. The customer or the user of DS3011A should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment–guidance Voltage dips, short interruptions and voltage variations on power supply lines IEC61000-4-11 < 5% UT (>95% dip in UT) for 0.5 cycle 40% UT (60% dip in UT) for 5 cycle 70% UT (30% dip in UT) for 25 cycle < 5% UT (>95% dip in UT) for 5 sec < 5% UT (>95% dip in UT) for 0.5 cycle 40% UT (60% dip in UT) for 5 cycle 70% UT (30% dip in UT) for 25 cycle < 5% UT (>95% dip in UT) for 5 sec Mains power quality should be that of a typical commercial or hospital environment.  If the user of the DS3011A requires continued operation during power mains interruptions, it is recommended that the DS3011A be powered from an uninterruptible power supply or a battery. NOTE UT is the a.c. mains voltage prior to application of the test level. Conducted RF IEC 61000-4-6   Radiated RF IEC 61000-4-3 3 Vrms 150 kHz to 80 MHz   3 V/m 80 MHz to 2.5 GHz 3 Vrms    3 V/m  Portable and mobile RF communications equipment should be used no closer to any part of the DS3011A, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.  Recommended separation distance: d= 1,2 √𝑃 d = 1,2 √𝑃 80 MHz to 800 MHz d = 2,3 √𝑃 800 MHz to 2,5 GHz  Where P is the maximum output power rating of the DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 47 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   transmitter in watts (W) according to the   Declaration – Electromagnetic Immunity – Continued The IMEDIPLUS Electronic Stethoscope DS3011A is intended for use in the electromagnetic environment specified below. The customer or the user of DS3011A should assure that it is used in such an environment. Immunity test IEC 60601 test level Compliance level Electromagnetic environment–guidance Conducted RF IEC 61000-4-6   Radiated RF IEC 61000-4-3 3 Vrms 150 kHz to 80 MHz   3 V/m 80 MHz to 2.5 GHz 3 Vrms    3 V/m  transmitter manufacturer and d is the recommended separation distance in meters (m).   Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range. b  Interference may occur in the vicinity of equipment marked with the following symbol:   NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a  Field  strengths  from  fixed  transmitters,  such  as  base  stations  for  radio  (cellular/cordless) telephones  and  land  mobile  radios,  amateur  radio,  AM  and  FM  radio  broadcast  and  TV broadcast  cannot  be  predicted  theoretically  with  accuracy.  To  assess  the  electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If  the  measured  field  strength  in  the  location  in  which  the  DS3011A  is  used  exceeds  the applicable  RF  compliance  level  above,  the  DS3011A  should  be  observed  to  verify  normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the DS3011A. b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.       DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 48 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23    Recommended Separation Distances Between Portable and Mobile RF Communications Equipment and the IMEDIPLUS Electronic Stethoscope DS3011A The DS3011A is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the DS3011A can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the DS3011A as recommended below, according to the maximum output of the communications equipment. Rated maximum output power of transmitter, P [W] Separation distance according to frequency of transmitters, d [m] 150 kHz to 80 MHz d = 1,2 √𝑃 80 MHz to 800 MHz d = 1,2 √𝑃 800 MHz to 2,5 GHz d = 2,3 √𝑃 0.01 0.12 0.12 0.23 0.1 0.38 0.38 0.73 1 1.2 1.2 2.3 10 3.8 3.8 7.3 100 12 12 23 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.  WARNING:     To reduce the risks associated with the strong electromagnetic fields, we shall avoid using the electronic stethoscope near the strong radio frequency signals or portable and/or mobile RF devices. The electronic stethoscope might be damaged, if you hear sudden or unexpected sounds. Please immediately move away from any radio transmitting antennas to protect from damage. 19. EMC Compliance FCC Intentional Radiator Certification iMED+ / CaRDIaRT Electronic Stethoscope Model DS3011A FCC ID: 2AM7NDS3011A  This device complies with Part 15 of the FCC rules. Operation is subject to the  following  two  conditions:  (1)  This  device  may  not  cause  harmful DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 49 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   interference,  and  (2)  this  device  must  accept  any  interference  received, including interference that may cause undesirable operation. This equipment has been tested and found to comply with the limits for a Class B  digital  device,  pursuant  to  part  15  of  the  FCC  rules.  These  limits  are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if  not  installed  and  used  in  accordance  with  the  instructions,  may  cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna. -Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. You are cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user’s authority to operate the equipment.   Industry Canada Intentional Radiator Certification IC: 23024-DS3011A Industry Canada Statement This device complies with Industry Canada's licence-exempt RSSs. Operation is  subject  to  the  following  two  conditions:  (1)  this  device  may  not  cause interference,  and  (2)  this  device  must  accept  any  interference,  including interference that may cause undesired operation of the device.  DS3011A Document For SGS Certification
 Document Title:  Electronic Stethoscope DS3011A User Manual Document No.: DS3011A-SDUS001-01302 Page: 50 of 50 Product Name: Electronic Stethoscope DS3011A Ver.: A1 510(k) File Name: 002_Electronic Stethoscope DS3011A User Manual  Date: 2017/6/23   Avis d’industrie Canada Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et, and (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement.  Industry Canada Class B Emission Compliance Statement This Class B digital apparatus complies with Canadian ICES-003. Avis de conformite a la reglementation d'Industrie Canada. Cet appareil numerique de la classe B est conforme a la norme NMB-003 du Canada.  Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies  pour  un  environnement  non  contrôlé.  Cet  équipement  doit  être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. NCC 根據 NCC 低功率電波輻射性電機管理辦法規定: 第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加大功率或變更原設計之特性及功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。低功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾。   DS3011A Document For SGS Certification

Navigation menu