INID BV SmartProx XS mdoc091201

User manual

Download: INID SPXSRDR SmartProx XS User Manual mdoc091201
Mirror Download [FCC.gov]INID SPXSRDR SmartProx XS User Manual mdoc091201
Document ID3093328
Application IDDWaX92XGRbnOUHdkzciBUg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize30.59kB (382316 bits)
Date Submitted2016-08-10 00:00:00
Date Available2016-08-15 00:00:00
Creation Date2016-08-08 10:13:04
Producing SoftwareLibreOffice 5.0
Document Lastmod0000-00-00 00:00:00
Document Titlemdoc091201
Document CreatorWriter
Document Author: Mark Olde

INID XS readers Installation Manual
Certifications
CE, FCC, IC, UL, ULC
FCC ID: YAB-MSXSRDR
YAB-SPXSRDR
YAB-SRXSRDR
IC:
8908A-MSXSRDR
8908A-SPXSRDR
8908A-SRXSRDR
(MultiSmart XS readers)
(SmartProx XS readers)
(SmartReader XS readers)
(MultiSmart XS readers)
(SmartProx XS readers)
(SmartReader XS readers)
Consult your National Authority if any authorization is needed for
these products.
Warning (part 15.21)
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate
the equipment.
Compliance statement
This device complies with part 15 of the FCC Rules and with the
Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including
interference that may cause undesired operation.
Models
number name
5040C
5000C
5045C
5005C
5240C
5200C
article
number
interfaces
INID SmartReader XS PIN
INID SmartReader XS
INID MultiSmart XS PIN
INID MultiSmart XS
INID SmartProx XS PIN
INID SmartProx XS
WG/C&D/TTL + RS485
WG/C&D/TTL + RS485
WG/C&D/TTL + RS485
WG/C&D/TTL + RS485
WG/C&D/TTL + RS485
WG/C&D/TTL + RS485
500-5040C
500-5000C
500-5045C
500-5005C
500-5240C
500-5200C
Classifications
UL 294:
destructive attack level IV, line security level I,
endurance level IV, standby power level I
ULC S319:
class III
Specifications
Dimensions
143 x 50 x 25 mm / 5⅝ x 2 x 1 inch
Operating temperature
-25° to 65° C / -15° to 150° F
Le présent appareil est conforme aux CNR d’Industrie Canada
applicables aux appareils radio exempts de licence. L’exploitation est
autorisée aux deux conditions suivantes :
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.
Information to the User (Part 15.105 (b))
Note: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Complies with: CAN ICES-3 (B)/NMB-3(B)
Protection class
IP54 Complete protection against contact, protection
against dust deposit.
Protection from splashed water.
Operation
When a credential is read successfully, the LED bar lights briefly, the
sounder sounds a short tone and the credential associated code is sent
to the Host system.
Power Supply
All models
7.0 - 24 Volt DC
models
Watts
at Vmin
The LED bar and sounder are also controllable by the Host system.
mA
at 12 VDC
When a PIN is entered the data is sent to the Host system; at each key
press a click sound is produced and the LED bar lights briefly. The
backlight of the PIN code lights up after a successful credential read, or
100
at the first key press.
110
100 Reader output formats are determined by the personalization of the
110 credential and/or configuration of the reader; on SmartReader and
85 MultiSmart readers the behaviour of the LED bar and sounder can be
85 modified through configuration.
When the reader detects a tamper status, the LED bar flashes red and
the tamper output is activated; on SmartReader and MultiSmart
readers this behaviour can be modified through configuration.
at Vmax
avg peak avg peak avg peak avg peak
5000C INID SmartReader XS
1,50 2,35 215 340 125 200
5040C INID SmartReader XS PIN 1,50 2,55 215 365 125 215
5005C INID MultiSmart XS
1,50 2,35 215 340 125 200
5045C INID MultiSmart XS PIN
1,50 2,55 215 365 125 215
5200C INID SmartProx XS
0,85 2,00 125 290 75 170
5240C INID SmartProx XS PIN
0,85 2,00 125 290 75 170
Note: Ohms’ Law may be used to estimate current at other voltages.
Parts included (1 each)
Reader front
Mounting backplate
Enclosure screw (Torx #8)
Installation manual
65
65
65
65
40
40
INID BV
Overweg 5
1713 HX Obdam
The Netherlands
Phone: +31 (0)226 450 009
Web: www.inid-readers.com
Document 100.14.IS.01 v1.30, effective from SN1632-0001
page 1 of 2
printed on Aug 8, 2016
INID XS readers Installation Manual
Cable specifications
 Shielded cable is required for ULC S319 compliance.
 The use of stranded conductors cable is highly recommended.
 Restrict oversizing the cable to a maximum of two sizes.
max. cable length
meters
feet
interface
61
91
152
25
1.5
61
152
1220
Wiegand
Clock / Data
TTL serial
RS485 (cable power)
RS485 (local power)
1)
200
300
500
80
200
500
4000
min. conductor size1)
mm 2
AWG
0.25
24
0.34
22
0.25
24
0.25
0.34
0,16
24
22
25
With a 12 V supply. With a 24 V supply, minimum conductor size is AWG 24 (0.25mm2) for
all interfaces and lengths.
For locally powered readers the minimum conductor size is AWG 25 (0.16mm2) for all
interfaces and lengths.
Connector Assignments
connector position
Wiegand
LED1-green LED2-red D1
D0 BUZZER TAMPER GND POWER
Clock/Data LED1-green LED2-red DATA CLOCK BUZZER TAMPER GND POWER
TTL serial
LED1-green LED2-red TXD
TXE
RXD TAMPER GND POWER
standard LED1-green LED2-red
N.C.
RS485
TRX+ TRXTAMPER GND POWER
OSDP
INPUT 1
INPUT 2
INPUT 3
Caution
Floating communication lines may cause spurious emissions, invalidating certification.
Ensure all communication lines are properly biased and terminated.
interface
3. Pull the cable trough the hole in the backplate; protect the cable
against sharp edges and any damage from chafing.
4. Mount the backplate using flat head screws with a shank size of
4mm (5/32”, #7) or smaller; other screw types or sizes may cause
irrepairable damage to the reader.
5. Prepare the end of the cable and wires, eliminating any loose or
frayed strands; for stranded conductors, the use of ferrules is highly
recommended.
Keep the wire ends as short as practical.
6. Connect the wires to the connector according to the interface type.
Wire ends, termination resistor leads and optional permanent links
shall be kept as short as possible.
Use an appropriate sized screwdriver and do not over-tighten the
connector screws.
7. Place the reader front section over the hinge of the backplate (see
drawing) and close the reader, keeping the wiring in the lower part
of the reader housing. DO NOT use excessive force, retract the
cable if necessary.
8. Test the reader: apply power and present a valid credential. The
LED bar should flash and the sounder should produce a short tone
indicating a successful read. If the Host system is connected to the
LED bar and sounder inputs these should follow the functionality of
the Host system.
Note:
The reader must be fully closed or the tamper circuit will
activate, indicated by a flashing LED bar.
9. The reader front can now be secured to the backplate using the
supplied enclosure screw.
SmartProx XS DIP switch settings
card
type
off off
off on
on off
on on
output
format
off
off
off
off
on
on
on
on
off
off
on
on
off
off
on
on
factory default:
all switches off.
PIN
format1)
off
on
off
on
off
on
off
on
off
off
on
on
off
on
off
on
H-PX & A-PX
EM4102
PX light
QKEY
AUTO (H-PX & A-PX only)
WG 26
WG 32
WG 34
WG 37
WG 40
WG 42
ABA 10
WG 4
WG 8
WG 4+4
CLK/DTA trk2 ABA
Note
Selecting AUTO format for cards EM4102, PX light or QKEY will cause
unpredictable behaviour.
1)
Not functional in readers without PIN pad.
Installation instructions
All wiring shall be in accordance with appliccable
codes and regulations
(USA: ANSI/NFPA70; Canada: CSA C22.1)
use ONLY flat head screws, maximum shank size 4mm (5/32”, #7)
1. Determine an appropriate position for the reader; a height of
140 cm (55 inches) above floor level on the doorjamb at the lock
side of the door is recommended.
Observe applicable building codes and safety regulations in
determining the reader position.
Notes:
╺ Mounting readers in close proximity of each other wil reduce
performance. The minimum recommended mounting distance
side-by-side or back-to-back is 125mm (5”). Closer mounting will
reduce performance, or cause unintentional reads on the other
reader; magnetic shielding may be necessary in that case.
╺ Mounting the reader on a metal surface will reduce performance,
a plastic separator of at least 6mm (¼”) is recommened.
╺ See Application Note AN100.14001 on the INID website for more
details.
2. Drill two pilot holes for mounting the backplate and one hole for the
cable, see drawing for measurements.
Document 100.14.IS.01 v1.30, effective from SN1632-0001
page 2 of 2
printed on Aug 8, 2016

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 2
Language                        : en-US
Title                           : mdoc091201
Author                          : Mark Olde
Creator                         : Writer
Producer                        : LibreOffice 5.0
Create Date                     : 2016:08:08 10:13:04+02:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: YAB-SPXSRDR

Navigation menu