User manual
INID XS readers Installation Manual Certifications CE, FCC, IC, UL, ULC FCC ID: YAB-MSXSRDR YAB-SPXSRDR YAB-SRXSRDR IC: 8908A-MSXSRDR 8908A-SPXSRDR 8908A-SRXSRDR (MultiSmart XS readers) (SmartProx XS readers) (SmartReader XS readers) (MultiSmart XS readers) (SmartProx XS readers) (SmartReader XS readers) Consult your National Authority if any authorization is needed for these products. Warning (part 15.21) Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Compliance statement This device complies with part 15 of the FCC Rules and with the Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Models number name 5040C 5000C 5045C 5005C 5240C 5200C article number interfaces INID SmartReader XS PIN INID SmartReader XS INID MultiSmart XS PIN INID MultiSmart XS INID SmartProx XS PIN INID SmartProx XS WG/C&D/TTL + RS485 WG/C&D/TTL + RS485 WG/C&D/TTL + RS485 WG/C&D/TTL + RS485 WG/C&D/TTL + RS485 WG/C&D/TTL + RS485 500-5040C 500-5000C 500-5045C 500-5005C 500-5240C 500-5200C Classifications UL 294: destructive attack level IV, line security level I, endurance level IV, standby power level I ULC S319: class III Specifications Dimensions 143 x 50 x 25 mm / 5⅝ x 2 x 1 inch Operating temperature -25° to 65° C / -15° to 150° F Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement. Information to the User (Part 15.105 (b)) Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: — Reorient or relocate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. — Consult the dealer or an experienced radio/TV technician for help. Complies with: CAN ICES-3 (B)/NMB-3(B) Protection class IP54 Complete protection against contact, protection against dust deposit. Protection from splashed water. Operation When a credential is read successfully, the LED bar lights briefly, the sounder sounds a short tone and the credential associated code is sent to the Host system. Power Supply All models 7.0 - 24 Volt DC models Watts at Vmin The LED bar and sounder are also controllable by the Host system. mA at 12 VDC When a PIN is entered the data is sent to the Host system; at each key press a click sound is produced and the LED bar lights briefly. The backlight of the PIN code lights up after a successful credential read, or 100 at the first key press. 110 100 Reader output formats are determined by the personalization of the 110 credential and/or configuration of the reader; on SmartReader and 85 MultiSmart readers the behaviour of the LED bar and sounder can be 85 modified through configuration. When the reader detects a tamper status, the LED bar flashes red and the tamper output is activated; on SmartReader and MultiSmart readers this behaviour can be modified through configuration. at Vmax avg peak avg peak avg peak avg peak 5000C INID SmartReader XS 1,50 2,35 215 340 125 200 5040C INID SmartReader XS PIN 1,50 2,55 215 365 125 215 5005C INID MultiSmart XS 1,50 2,35 215 340 125 200 5045C INID MultiSmart XS PIN 1,50 2,55 215 365 125 215 5200C INID SmartProx XS 0,85 2,00 125 290 75 170 5240C INID SmartProx XS PIN 0,85 2,00 125 290 75 170 Note: Ohms’ Law may be used to estimate current at other voltages. Parts included (1 each) Reader front Mounting backplate Enclosure screw (Torx #8) Installation manual 65 65 65 65 40 40 INID BV Overweg 5 1713 HX Obdam The Netherlands Phone: +31 (0)226 450 009 Web: www.inid-readers.com Document 100.14.IS.01 v1.30, effective from SN1632-0001 page 1 of 2 printed on Aug 8, 2016 INID XS readers Installation Manual Cable specifications Shielded cable is required for ULC S319 compliance. The use of stranded conductors cable is highly recommended. Restrict oversizing the cable to a maximum of two sizes. max. cable length meters feet interface 61 91 152 25 1.5 61 152 1220 Wiegand Clock / Data TTL serial RS485 (cable power) RS485 (local power) 1) 200 300 500 80 200 500 4000 min. conductor size1) mm 2 AWG 0.25 24 0.34 22 0.25 24 0.25 0.34 0,16 24 22 25 With a 12 V supply. With a 24 V supply, minimum conductor size is AWG 24 (0.25mm2) for all interfaces and lengths. For locally powered readers the minimum conductor size is AWG 25 (0.16mm2) for all interfaces and lengths. Connector Assignments connector position Wiegand LED1-green LED2-red D1 D0 BUZZER TAMPER GND POWER Clock/Data LED1-green LED2-red DATA CLOCK BUZZER TAMPER GND POWER TTL serial LED1-green LED2-red TXD TXE RXD TAMPER GND POWER standard LED1-green LED2-red N.C. RS485 TRX+ TRXTAMPER GND POWER OSDP INPUT 1 INPUT 2 INPUT 3 Caution Floating communication lines may cause spurious emissions, invalidating certification. Ensure all communication lines are properly biased and terminated. interface 3. Pull the cable trough the hole in the backplate; protect the cable against sharp edges and any damage from chafing. 4. Mount the backplate using flat head screws with a shank size of 4mm (5/32”, #7) or smaller; other screw types or sizes may cause irrepairable damage to the reader. 5. Prepare the end of the cable and wires, eliminating any loose or frayed strands; for stranded conductors, the use of ferrules is highly recommended. Keep the wire ends as short as practical. 6. Connect the wires to the connector according to the interface type. Wire ends, termination resistor leads and optional permanent links shall be kept as short as possible. Use an appropriate sized screwdriver and do not over-tighten the connector screws. 7. Place the reader front section over the hinge of the backplate (see drawing) and close the reader, keeping the wiring in the lower part of the reader housing. DO NOT use excessive force, retract the cable if necessary. 8. Test the reader: apply power and present a valid credential. The LED bar should flash and the sounder should produce a short tone indicating a successful read. If the Host system is connected to the LED bar and sounder inputs these should follow the functionality of the Host system. Note: The reader must be fully closed or the tamper circuit will activate, indicated by a flashing LED bar. 9. The reader front can now be secured to the backplate using the supplied enclosure screw. SmartProx XS DIP switch settings card type off off off on on off on on output format off off off off on on on on off off on on off off on on factory default: all switches off. PIN format1) off on off on off on off on off off on on off on off on H-PX & A-PX EM4102 PX light QKEY AUTO (H-PX & A-PX only) WG 26 WG 32 WG 34 WG 37 WG 40 WG 42 ABA 10 WG 4 WG 8 WG 4+4 CLK/DTA trk2 ABA Note Selecting AUTO format for cards EM4102, PX light or QKEY will cause unpredictable behaviour. 1) Not functional in readers without PIN pad. Installation instructions All wiring shall be in accordance with appliccable codes and regulations (USA: ANSI/NFPA70; Canada: CSA C22.1) use ONLY flat head screws, maximum shank size 4mm (5/32”, #7) 1. Determine an appropriate position for the reader; a height of 140 cm (55 inches) above floor level on the doorjamb at the lock side of the door is recommended. Observe applicable building codes and safety regulations in determining the reader position. Notes: ╺ Mounting readers in close proximity of each other wil reduce performance. The minimum recommended mounting distance side-by-side or back-to-back is 125mm (5”). Closer mounting will reduce performance, or cause unintentional reads on the other reader; magnetic shielding may be necessary in that case. ╺ Mounting the reader on a metal surface will reduce performance, a plastic separator of at least 6mm (¼”) is recommened. ╺ See Application Note AN100.14001 on the INID website for more details. 2. Drill two pilot holes for mounting the backplate and one hole for the cable, see drawing for measurements. Document 100.14.IS.01 v1.30, effective from SN1632-0001 page 2 of 2 printed on Aug 8, 2016
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 2 Language : en-US Title : mdoc091201 Author : Mark Olde Creator : Writer Producer : LibreOffice 5.0 Create Date : 2016:08:08 10:13:04+02:00EXIF Metadata provided by EXIF.tools