INID SRXSRDR SmartReader XS User Manual mdoc091201

INID BV SmartReader XS mdoc091201

Users Manual

INID XS readers Installation ManualModelsnumber name interfaces articlenumber5040C INID SmartReader XS PIN WG/C&D/TTL + RS485 500-5040C5000C INID SmartReader XS WG/C&D/TTL + RS485 500-5000C5045C INID MultiSmart XS PIN WG/C&D/TTL + RS485 500-5045C5005C INID MultiSmart XS WG/C&D/TTL + RS485 500-5005C5240C INID SmartProx XS PIN WG/C&D/TTL + RS485 500-5240C5200C INID SmartProx XS WG/C&D/TTL + RS485 500-5200CClassificationsUL 294: destructive attack level IV, line security level I,endurance level IV, standby power level IULC S319: class IIISpecificationsDimensions143 x 50 x 25 mm / 5⅝ x 2 x 1 inchOperating temperature-25° to 65° C / -15° to 150° FProtection classIP54 Complete protection against contact, protection against dust deposit.Protection from splashed water.Power Supply All models 7.0 - 24 Volt DCmodels Watts mAat Vmin at 12 VDC at Vmaxavg peak avg peak avg peak avg peak5000C INID SmartReader XS 1,50 2,35 215 340 125 200 65 1005040C INID SmartReader XS PIN 1,50 2,55 215 365 125 215 65 1105005C INID MultiSmart XS 1,50 2,35 215 340 125 200 65 1005045C INID MultiSmart XS PIN 1,50 2,55 215 365 125 215 65 1105200C INID SmartProx XS 0,85 2,00 125 290 75 170 40 855240C INID SmartProx XS PIN 0,85 2,00 125 290 75 170 40 85Note: Ohms’ Law may be used to estimate current at other voltages.Parts included (1 each)Reader frontMounting backplateEnclosure screw (Torx #8)Installation manualCertificationsCE, FCC, IC, UL, ULCFCC ID: YAB-MSXSRDR (MultiSmart XS readers)YAB-SPXSRDR (SmartProx XS readers)YAB-SRXSRDR (SmartReader XS readers)IC: 8908A-MSXSRDR (MultiSmart XS readers)8908A-SPXSRDR (SmartProx XS readers)8908A-SRXSRDR (SmartReader XS readers)Consult your National Authority if any authorization is needed for these products.Warning (part 15.21)Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.Compliance statementThis device complies with part 15 of the FCC Rules and with the Industry Canada license-exempt RSS standard(s).Operation is subject to the following two conditions:(1) this device may not cause harmful interference, and(2) this device must accept any interference received, including interference that may cause undesired operation.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes :(1) l’appareil ne doit pas produire de brouillage, et(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.Information to the User (Part 15.105 (b))Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:—Reorient or relocate the receiving antenna.—Increase the separation between the equipment and receiver.—Connect the equipment into an outlet on a circuit different from thatto which the receiver is connected.—Consult the dealer or an experienced radio/TV technician for help.Complies with:  CAN ICES-3 (B)/NMB-3(B)OperationWhen a credential is read successfully, the LED bar lights briefly, the sounder sounds a short tone and the credential associated code is sent to the Host system.The LED bar and sounder are also controllable by the Host system.When a PIN is entered the data is sent to the Host system; at each keypress a click sound is produced and the LED bar lights briefly. The backlight of the PIN code lights up after a successful credential read, orat the first key press.Reader output formats are determined by the personalization of the credential and/or configuration of the reader; on SmartReader and MultiSmart readers the behaviour of the LED bar and sounder can be modified through configuration.When the reader detects a tamper status, the LED bar flashes red and the tamper output is activated; on SmartReader and MultiSmart readers this behaviour can be modified through configuration.Document 100.14.IS.01 v1.30, effective from SN1632-0001 page 1 of 2 printed on Aug 8, 2016INID BVOverweg 51713 HX  ObdamThe NetherlandsPhone: +31 (0)226 450 009Web: www.inid-readers.com
INID XS readers Installation ManualCable specificationsShielded cable is required for ULC S319 compliance.The use of stranded conductors cable is highly recommended.Restrict oversizing the cable to a maximum of two sizes.interface max. cable length min. conductor size1)meters feet mm2AWGWiegand61 200 0.25 2491 300152 500 0.34 22Clock / Data 25 80 0.25 24TTL serial 1.5 5RS485 (cable power) 61 200 0.25 24152 500 0.34 22RS485 (local power) 1220 4000 0,16 251) With a 12 V supply. With a 24 V supply, minimum conductor size is AWG 24 (0.25mm2) for all interfaces and lengths.For locally powered readers the minimum conductor size is AWG 25 (0.16mm2) for all interfaces and lengths.Connector Assignmentsinterface connector position1 2 3 4 5 6 7 8Wiegand LED1-green LED2-red D1 D0 BUZZER TAMPER GND POWERClock/Data LED1-green LED2-red DATA CLOCK BUZZER TAMPER GND POWERTTL serial LED1-green LED2-red TXD TXE RXD TAMPER GND POWERRS485 standard LED1-green LED2-red TRX+ TRX- N.C. TAMPER GND POWEROSDP INPUT 1 INPUT 2 INPUT 3CautionFloating communication lines may cause spurious emissions, invalidating certification.Ensure all communication lines are properly biased and terminated.SmartProx XS DIP switch settings1234567 factory default:all switches off.cardtypeoutputformatPINformat1)off off H-PX & A-PXoff on EM4102on off PX lighton on QKEYoff off off AUTO (H-PX & A-PX only)off off on WG 26off on off WG 32off on on WG 34on off off WG 37on off on WG 40on on off WG 42on on on ABA 10off off WG 4off on WG 8on off WG 4+4on on CLK/DTA trk2 ABANoteSelecting AUTO format for cards EM4102, PX light or QKEY will cause unpredictable behaviour.1) Not functional in readers without PIN pad.Installation instructionsAll wiring shall be in accordance with appliccablecodes and regulations(USA: ANSI/NFPA70; Canada: CSA C22.1)1. Determine an appropriate position for the reader; a height of 140 cm (55 inches) above floor level on the doorjamb at the lock side of the door is recommended.Observe applicable building codes and safety regulations in determining the reader position.Notes:╺Mounting readers in close proximity of each other wil reduce performance. The minimum recommended mounting distance side-by-side or back-to-back is 125mm (5”). Closer mounting willreduce performance, or cause unintentional reads on the other reader; magnetic shielding may be necessary in that case.╺Mounting the reader on a metal surface will reduce performance,a plastic separator of at least 6mm (¼”) is recommened.╺See Application Note AN100.14001 on the INID website for moredetails.2. Drill two pilot holes for mounting the backplate and one hole for thecable, see drawing for measurements.3. Pull the cable trough the hole in the backplate; protect the cable against sharp edges and any damage from chafing.4. Mount the backplate using flat head screws with a shank size of 4mm (5/32”, #7) or smaller; other screw types or sizes may cause irrepairable damage to the reader.5. Prepare the end of the cable and wires, eliminating any loose or frayed strands; for stranded conductors, the use of ferrules is highlyrecommended.Keep the wire ends as short as practical.6. Connect the wires to the connector according to the interface type.Wire ends, termination resistor leads and optional permanent links shall be kept as short as possible.Use an appropriate sized screwdriver and do not over-tighten the connector screws.7. Place the reader front section over the hinge of the backplate (see drawing) and close the reader, keeping the wiring in the lower part of the reader housing. DO NOT use excessive force, retract the cable if necessary.8. Test the reader: apply power and present a valid credential. The LED bar should flash and the sounder should produce a short tone indicating a successful read. If the Host system is connected to the LED bar and sounder inputs these should follow the functionality of the Host system.Note:The reader must be fully closed or the tamper circuit will activate, indicated by a flashing LED bar.9. The reader front can now be secured to the backplate using the supplied enclosure screw.use ONLY flat head screws, maximum shank size 4mm (5/32”, #7)Document 100.14.IS.01 v1.30, effective from SN1632-0001 page 2 of 2 printed on Aug 8, 2016

Navigation menu